• Title/Summary/Keyword: surface contamination

Search Result 926, Processing Time 0.038 seconds

Contamination measurement, Analysis & Control for Satellite (인공위성의 오염 측정, 분석 및 관리)

  • Lee, Sang-Hoon;Hong, Seok-Jong;Cho, Hyok-Jin;Seo, Hee-Jun;Moon, Guee-Won
    • Aerospace Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.116-122
    • /
    • 2010
  • It is necessary to be careful about contamination control to minimize the accumulation of the contamination material on satellite surface during the I&T phase. In the space environment which characterized by high vacuum, high and very low temperature, contamination material causes satellite to lose its own performance. Especially, contamination material can accumulate on critical surfaces such as lenses, mirrors, and sensors. KARI(Korea Aerospace Research Institute) conducts the clean room to control and minimize the contamination effect. This paper introduces the principle of contamination and the method of measure and analysis for the contamination.

TENSILE STRENGTHS OF PRE-LIGATURED BUTTON WITH SEVERAL TYPES OF CONTAMINATION IN DIRECT BONDING PROCEDURE WHICH CAN HAPPEN DURING THE SURGICAL EXPOSURE OF UNERUPTED TEETH (치아의 견인을 위한 버튼 접착시 오염이 인장강동에 미치는 영향)

  • Kim, Seong-Oh;Choi, Byung-Jai;Lee, Jae-Ho;Sohn, Heung-Kyu
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.25 no.2
    • /
    • pp.400-420
    • /
    • 1998
  • We already know that it is very difficult to obtain an "isolated field" for direct bonding during the surgical exposure of unerupted teeth. The aim of this in-vitro study is to simulate the clinical situation of forced eruption and to evaluate the tensile strengths of preligatured button with several types of contamination which can happen during the surgical exposure of unerupted teeth. Four orthodontic direct bonding systems were used. ($Ortho-One^{TM}$, $Rely-a-Bond^{(R)}$, $Ortho-Two^{TM}$, Phase $II^{(R)}$) Each material was divided into four groups(n=20) : Group 1. (Control, no contamination), Group 2. (Rinse etching agent with saline instead of water), Group 3. (Blood contamination of etched surface for 30 seconds), Group 4. (Blood contamination of primed surface for 30 seconds) 320 bovine anterior permanent teeth were divided into the above mentioned 16 groups. Enamel surface was flattened and ground under water coolant. Pre-ligatured buttons were prepared to the same form. (Cut 0.25 ligature wire 10 cm in length. Twist the ligature wire 30 times clockwise. Mark the wire 15mm and 35mm points from button. Make a loop sticking two points together and twist the loop 6 times counterclockwise.) The bonded specimens were stored at $37^{\circ}C$ saline solution for 3 days. Then the tensile strength of each sample was measured with Instron universal testing machine, crosshead speed of 0.5mm/min. The following results were obtained: 1. As compared to control groups (Group 1) of each material, Rely-a-Bond had a significantly lower mean tensile strengths than other material. (p<0.01) 2. In Group 2. of Ortho-One and Rely-a-Bond, the mean tensile strengths decreased about 7.7% and 11.1%, respectively with statistical significances. (p<0.05) 3. In Group 2. of Ortho-Two and Phase II, the mean tensile strengths did not decrease. 4. In Group 3. of Ortho-One, Rely-a-Bond, Ortho-Two, and Phase II, the mean tensile strengths decreased about 60.8%, 56.1%, 60.2%, and 46.0%, respectively with statistical significances. (p<0.01) 5. In Group 4. of Ortho-One and Rely-a-Bond, the mean tensile strengths did not decrease. 6. In Group 4. of Ortho-Two and Phase II, the mean tensile strengths were decreased about 20.95% and 22.28%, respectively with statistical significances. (p<0.01) There were formations of a hump shaped mass from bonding resin under blood contamination which disturbed direct bonding procedure. According to Reynolds, the proper bond strength for clinical manipulation should be at least 45N or about 4.5Kg.F. According to these results, it can be concluded that Ortho-One could be used during surgical exposure of unerupted teeth. In any case, blood contamination of the etched surface should be avoided, but the blood contamination of primed surface of Ortho-One may not decrease bond strength. Just 'blowing-out' is enough to remove blood from primed surface of Ortho-One. You can verify the clean surface of the primer of Ortho-One after blowing out the blood contamination.

  • PDF

Influence of Plasma Corrosion Resistance of Y2O3 Coated Parts by Cleaning Process (세정공정에 따른 Y2O3 코팅부품의 내플라즈마성 영향)

  • Kim, Minjoong;Shin, Jae-Soo;Yun, Ju-Young
    • Journal of the Korean institute of surface engineering
    • /
    • v.54 no.6
    • /
    • pp.365-370
    • /
    • 2021
  • In this research, we proceeded with research on plasma resistance of the cleaning process of APS(Atmospheric Plasma Spray)-Y2O3 coated parts used for semiconductor and display plasma process equipment. CF4, O2, and Ar mixed gas were used for the plasma environment, and respective alconox, surfactant, and piranha solution was used for the cleaning process. After APS-Y2O3 was exposed to CF4 plasma, the surface changed from Y2O3 to YF3 and a large amount of carbon was deposited. For this reason, the plasma corrosion resistance was lowered and contamination particles were generated. We performed a cleaning process to remove the defect-inducing surface YF3 layer and carbon layer. Among three cleaning solutions, the piranha cleaning process had the highest detergency and the alconox cleaning process had the lowest detergency. Such results could be confirmed through the etching amount, morphology, composition, and accumulated contamination particle analysis results. Piranha cleaning process showed the highest detergency, but due to the very large thickness reduction, the base metal was exposed and a large number of contaminated particles were generated. In contrast, the surfactant cleaning process exhibit excellent properties in terms of surface detergency, etching amount, and accumulated contamination particle analysis.

Contamination Assessment of Surface Sediments in Urban Rivers, Busan (부산지역 도시하천 표층 퇴적물 오염도 평가에 관한 연구)

  • Kwag, Jin-Suk;Son, Jung-Won;Kim, Chu-In;Song, Bok-Joo
    • Journal of Korean Society on Water Environment
    • /
    • v.37 no.4
    • /
    • pp.296-305
    • /
    • 2021
  • This work investigated heavy metal pollution in surface sediments of rivers in Busan, Korea. Surface sediments were analyzed in order to conduct contamination assessment of organic matter, nutrients, and heavy metal concentrations. Contamination assessment of heavy metals was conducted using geoaccumulation index (Igeo), pollution load index (PLI), and potential ecological risk index (RI). Accumulation of organic matter and nutrients were affected by water discharged from sewage treatment plant. The concentrations of organic matter and nutrients were found to be greater in points which were close to the sewage treatment plant more than points furthest. The concentrations of Pb, Zn, Cu, Cd, Hg, As, Cr, and Ni were found to be greater in surface sediment more than in the background. The mean concentrations of heavy metals were in the order of Zn (323.5 mg/kg) > Cu (70.5 mg/kg) > Pb (39.8 mg/kg) > Cr (33.4 mg/kg) > Ni (13.5 mg/kg) > As (9.4 mg/kg) > Cd (0.84 mg/kg) > Hg (0.092 mg/kg). The result of geoaccumulation indices indicated that Hg > Cr > Cu > Ni > Zn > As > Pb > Cd were found in order of severe contamination by heavy metals. From PLI and RI analysis, it was evident that the Suyeonggang 2 was the most contaminated river.

Cleaning and Decontamination Method of Books for Their Sanitary Circulation (책의 위생적 유통관리를 위한 세정 소독 방법)

  • Kim, Nam Yong;An, Duck Soon;Choi, Young Il;Jung, Yong Bae;Kim, Jung Min;Lee, Dong Sun
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.19 no.1
    • /
    • pp.11-15
    • /
    • 2013
  • In order to find a sanitary logistic way to handle library books, papers and environmental sources contacting the books were tested in their microbial contamination load and methods to decontaminate the books were investigated. Generally bacterial load of inner book pages was very low, but increased when contaminated with liquid such as saliva. In contrast, their lateral ends showed much higher bacterial contamination presumably due to dry dust contamination on there. As operations to improve the sanitary book conditions, turbulent air blow was found to be workable for reducing dry dusty contamination and 280 nm ultra-violet (UV) light emitting diode (LED) was so for decontaminating wet surface contamination. Microbial inactivation by the UV LED could be realized with irradiation for more than 5 minutes at 2 cm distance. Air blow of 5.5 m/s for 0.5~1 minute could reduce the dusty contamination on a model book surface.

  • PDF

An Experimental Investigation on the Contamination Sensitivity of an Automotive Fuel Pump

  • Lee Jae-Cheon;Shin Hyun-Myng
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.6 no.3
    • /
    • pp.51-55
    • /
    • 2005
  • This study addresses the contamination sensitivity test of a typical fuel pump for an automotive vehicle. The objective of the study is to find the contamination sensitivity coefficient of a fuel pump on specific contaminant particle sizes so that an optimal fuel filter could be selected. To achieve the objective, the degradation of discharge flow rate of the fuel pump is measured under the experiments of various contaminants size ranges of ISO test dust up to $80\;{\mu}m$. The fundamental theory of contamination sensitivity is introduced and the contamination sensitivity coefficients are estimated using the experimental data. Maximum contamination sensitivity coefficient of $5\chi\;10^{-6}\;L/min{\cdot}Ea$ is found in the contaminant size range of $40\;{\mu}m\~50\;{\mu}m$. The magnified picture of the surface of vane disc reveals that the abrasive wear is the principal cause of discharge flow rate degradation. Hence, this study reveals that a high efficiency filter for contaminant particles especially in the size range of $30\;{\mu}m\~70\;{\mu}m$ especially should be used to maintain the service life of the fuel filter.

An Experimental Investigation on The Contamination Sensitivity of An Automotive Fuel Pump (자동차 연료펌프의 오염민감도 실험 연구)

  • 이재천;장지현;신현명
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.6
    • /
    • pp.102-108
    • /
    • 2004
  • This study addresses the contamination sensitivity test of a typical fuel pump for automotive vehicle. The objective of the study is to find the contamination sensitivity coefficient of fuel pump on specific contaminant particle sizes so that optimal fuel filter could be selected. To achieve the objective, the degradation of discharge flow rate of fuel pump was measured under the experiments of various contaminants size ranges of ISO test dust up to 80${\mu}{\textrm}{m}$. The fundamental theory of contamination sensitivity was introduced and the contamination sensitivity coefficients were estimated using the experimental data. Maximum contamination sensitivity coefficient of $5{\times}10^{-6}$ L/minㆍEa was found on the contaminant size range of 40${\mu}{\textrm}{m}$∼50${\mu}{\textrm}{m}$. The magnified picture of the surface of vane disc revealed that the abrasive wear was the principal cause of discharge flow rate degradation. Hence, this study revealed that high efficiency filter on the contaminant particle size range of 30${\mu}{\textrm}{m}$∼70${\mu}{\textrm}{m}$ especially should be used to maintain the service lift of the fuel filter.

Contamination Levels of Pharmaceuticals and Pesticides in the Gotjawal Regions of Jeju Island and Associated Ecotoxicities (곶자왈 지역의 의약물질과 농약의 오염수준과 생태독성영향)

  • Kang, Ha Byeong;Koh, Su Rim;Choi, Yoonsong;Lee, Sangwoo;Kho, YoungLim;Oh, Dalyoung;Choi, Kyungho
    • Journal of Environmental Health Sciences
    • /
    • v.39 no.5
    • /
    • pp.426-437
    • /
    • 2013
  • Objective: Gotjawal refers to a special geographical designation found in Jeju Province, Korea, where vegetation forms over a rocky area. Due to the important ecological value of Gotjawal, international concern about such areas is growing. However, only limited information is available regarding environmental contamination of Gotjawal. This study was conducted in order to investigate the levels of contamination and associated ecotoxicological effects of surface water bodies in Gotjawal. Methods: Surface water samples were collected at three sampling sites in two Gotjawal areas and were analyzed for several pharmaceuticals and pesticides in consideration of the potential sources of contamination. The ecotoxicity of the samples was measured using water fleas (Daphnia magna and Moina macrocopa) and zebrafish (Danio rerio). In addition, effects on the gene transcription of zebrafish were investigated following exposure to the samples. Results: Nine pharmaceuticals were detected in the samples, but none of the target pesticides were detected. Following acute exposure to two surface water samples, the survival of waterfleas was significantly reduced, but reproduction was not affected. In zebrafish, time-to-hatch was delayed and fry survival was decreased in some samples. On the other hand, at the transcriptional level, there were no genes significantly influenced by exposure to the samples. Conclusion: This is the first study investigating environmental contamination in Gotjawal areas and associated ecotoxicities. Further studies are warranted to identify the cause of acute Daphnia toxicity and to determine potential consequences of longer-term exposure in Gotjawal areas.

The characteristic of the elcetrostatic probe surface heated with current (가열식(加熱式) 정전탐침전극(靜電探針電極)의 표면특성(表面特性))

  • Kwak, Y.S.;Cho, J.S.;Park, C.H.;Kim, K.H.;Kim, S.P.;Kim, D.H.
    • Proceedings of the KIEE Conference
    • /
    • 1989.11a
    • /
    • pp.151-154
    • /
    • 1989
  • In the measurement of plasma parameters of the plasma C.V.D with probe method, the most important problem is the contamination of the probe surface. In this paper, we observe the surface contamination of probe surface with microscope and determine the critical current and the critical time to sustain the clean surface of probe in the plasma C.V.D.

  • PDF

Contaminations of MgO Thin Films by Phosphors for the Surface and Vertical Discharge Type AC-PDP

  • Jen, Ko-Ruey;Kim, Sung-O;Chen, Kuang-Lang;Chen, Samuel;Lee, Chien-Pang;Huang, Chih-Ming;Hsu, Chien-Hsing
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.18-20
    • /
    • 2006
  • The panels were fabricated to characterize the contamination of Magnesium Oxide (MgO) thin films by phosphors and ion bombardments in AC-PDPs. Forty-six inch WVGA panels of the surface and vertical discharge type were manufactured. The experiment was designed to investigate the relationship between the MgO thin films and phosphor contamination caused by ion bombardments in a plasma environment to produce a life time test. The contamination of MgO thin films by phosphors was investigated by way of X-ray photoelectron spectroscopy (XPS).

  • PDF