• Title/Summary/Keyword: surface contamination

Search Result 935, Processing Time 0.033 seconds

Investigation on DHF Application at Metal CMP Cleaning Process (Metal CMP 세정 공정에서 DHF 적용에 관한 연구)

  • 김남훈;김상용;김인표;장의구
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.7
    • /
    • pp.569-572
    • /
    • 2003
  • In this study, we evaluated the dilute HF cleaning to reduce residual defects made by metal CMP process. The purpose of this test is to observe the existence of barrier metal damage during DHF cleaning on condition that it should not affect metal thin film reliability, so we will get rid of slurry residual particles as a main defect of the metal CMP process for the better yield. In-line defect data showed us that slurry residual particles were removed by DHF application. The HF rinse significantly reduced metal contamination levels and surface roughness. The best effect by additional oxide loss was discovered when Dilute HF condition is 10".

Analyses of Leakage Current of Transmission Insulator as a Function of Environmental Condition (환경에 따른 송전용 애자의 누설전류 분석)

  • Choi, In-Hyuk;Lee, Dong-Il;Kim, Chan-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.1166-1170
    • /
    • 2004
  • The leakage currents of transmission insulator were investigated as a function of environmental conditions, such as temperature, humidity, and rainfall. The insulators were artificially contaminated with insoluble yellow soil and kaolin which helped salt to stick on the surface of insulator. The insulators contaminated with the grade of B, C, and D were installed in the KoChang Testing Center. The leakage currents were measured and compared with non-contaminated insulators. The results indicated that the most important factor affecting leakage current was humidity. After heavy rain, the artificially contaminated salt was dissolved, resulting in similar characteristics between with and without contamination

  • PDF

Fume Particle Dispersion in Laser Micro-Hole Machining with Oblique Stagnation Flow Conditions (경사 정체점 유동이 적용된 미세 홀 레이저 가공 공정의 흄 오염입자 산포특성 연구)

  • Kim, Kyoungjin;Park, Joong-Youn
    • Journal of the Semiconductor & Display Technology
    • /
    • v.20 no.3
    • /
    • pp.77-82
    • /
    • 2021
  • This numerical study focuses on the analysis of fume particle dispersion characteristics over the surface of target workpiece in laser micro-hole machining process. The effects of oblique stagnation flow over fume generating machining point are examined by carrying out a series of three-dimensional random particle simulations along with probabilistic particle generation model and particle drag correlation of low Reynolds number. Present computational model of fume particle dispersion is found to be capable of assessing and quantifying the fume particle contamination in precision hole machining which may influenced by different types of air flow patterns and their flow intensity. The particle size dependence on dispersion distance of fume particles from laser machining point is significant and the effects of increasing flow oblique angle are shown quite differently when slot blowing or slot suction flows are applied in micro-hole machining.

Inhibitory Effect of Dry-Heat Treatment and Chemical Sanitizers against Foodborne Pathogens Contaminated on the Surfaces of Materials (재질 표면에 오염된 여러 병원성 세균에 대한 건열살균 및 살균소독제의 저해효과)

  • Bae, Young-Min;Heu, Sun-Gi;Lee, Sun-Young
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.38 no.9
    • /
    • pp.1265-1270
    • /
    • 2009
  • Pathogens contaminated on the surface of utensils could contribute to the occurrence of outbreaks due to cross-contamination to foods during the food preparation process. Therefore, the efficacy of chemical sanitizers (chlorine-based and alcohol-based commercial sanitizers) and dry-heat ($71^{\circ}C$) on inhibiting biofilms of five foodborne pathogens (Escherichia coli O157:H7, Salmonella Typhimurium, Pseudomonas aeruginosa, Listeria monocytogenes, and Staphylococcus aureus) on the surface of stainless steel and polypropylene were investigated in this study. Initial populations of pathogens were 8.8$\sim$9.3 and 9.4$\sim$10.3 log CFU/coupon on the surface of stainless steel and polypropylene coupon, respectively, and these populations were not significantly reduced when they were treated with water for 5 min at room temperature. Treatments with chlorine sanitizer and dry-heat were not effective on inactivating pathogens on the surfaces of stainless steel and polypropylene. In contrast, treatments with alcohol sanitizer were very effective on inactivating pathogens on the surfaced of stainless steel and polypropylene. Reduction levels ranged from 3.4 to 6.4 log and from 5.5 to 7.4 log CFU/coupon in stainless steel and plastic coupons, respectively. From these results, alcohol-based sanitizer could be used as a potential way for controlling microbial contamination on the surface of utensils, cooking equipment, and other related environments.

Contamination Assessment of Heavy Metals in River Sediments (For the Surface Sediments from Nakdong River) (하천 퇴적물 내 중금속 오염도 평가에 관한 연구 (낙동강 수계 표층 퇴적물을 대상으로))

  • Kim, Shin;Ahn, Jungmin;Jung, Kangyoung;Lee, Kwonchul;Kwon, Heongak;Shin, Dongseok;Yang, Deukseok
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.4
    • /
    • pp.460-473
    • /
    • 2017
  • In order to certificate the contamination assessment of heavy metals in surface sediments from the Nakdong river. Surface sediments were collected of 24 sampling sites (main 14st., tributary 10st.) and analyzed for grain size heavy metals contents. Study area mainly composed of sand (avg. 94.1%) and mean grain size was $1.46{\Phi}$ on average. Heavy metals contents (avg. Al: 12.5%, Zn; 74.4, Cr: 45.3, Li: 26.0, Pb: 17.1, Ni: 10.5, Cu: 7.8, Cd: 0.22 mg/kg) were relatively high contents in the composed of fine sediments. In addition, the results of pearson's correlation coefficient showed that most heavy metals and grain size (silt and clay) were highly correlated. The contents of Zn (6st.) and Ni (1st.) evaluated as moderately polluted, Zn (6st.) evaluated as LEL when compared with sediment quality standard of USEPA and Ontario sediment quality guidelines. Most heavy metals contents were I levels that dose not affected the benthos when compared with sediment pollution evaluation standard of NIER. The results of EX, EF, Igeo and CF showed the contents of Zn, Pb and Cd exceed the background contents and distributing of anthropogenic pollution and evaluated as moderately polluted level. And Nm-08 were relatively high level of contamination in the study area. However as results of PLI (less than 1), all sampling sites were evaluated unpolluted level.

Evaluation of environmental surface contamination and disinfection effects on multidrug-resistant organism (다제내성균 환경표면 오염도 및 소독 효과 평가)

  • Kim, Jae Yeun;Park, Jung Ae;Lee, Mi Hyang;Kim, Sang Ha;Jeong, Sun Young
    • Journal of Digital Convergence
    • /
    • v.19 no.1
    • /
    • pp.211-216
    • /
    • 2021
  • This study was carried out to evaluate the effects of disinfection using environmental disinfectant after having assessed the extent of contamination through microbial culture testing and the Adenosine Triphosphate Bioluminescence method among the environmental management evaluation methods used for the environment in the hospital ward of patients infected by multidrug-resistant organisms. This study was conducted with the patient wards isolated due to multidrug-resistant organisms as the environmental surface. Specimens were collected from five locations including infusion pumps, IV poles, bedside cabinets, bed railings, keyboards, and blood pressure measurement cuffs. ATP and microbial culture testing were executed prior to, immediately after, and five minutes post-disinfection. According to the result contamination of the infusion pumps was statistically significantly reduced after disinfection. In addition, the bacteria before and after disinfection reduced in IV pole, bed railing, and keyboard. That is, regular environmental surface disinfection can provide safer environments to patients against infection. Therefore, it is necessary to establish guidelines including disinfection methods and intervals for environmental surfaces by evaluating the persistence of disinfectants at various institutions in the future.

Characteristics of Machined Surface Roughness and Surface Layers of WC-Co Tools with Plasma Source Ion Implantation (WC-Co 공구의 이온 주입에 따른 표면층 및 가공된 표면거칠기 특성)

  • Kang, Seong-Ki;Kim, Yung-Kyu;Wang, Duck-Hyun;Chun, Young-Rok;Kim, Won-Il
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.9 no.1
    • /
    • pp.106-113
    • /
    • 2010
  • The most suitable condition for plasma source ion implantation(PSII) was found based on the study of the characteristics of PSIIed tool and machined surfaces. The depth analysis according to the chemical bonding state of elements and surface component elements through the XPS and SIMS, was conducted to find the improved property of the PSIIed surface. Due to the diffusion of PSII, the nitrogen was found up to a depth of about 150nm according to the supplied voltage and ion implanted time. The deep diffusion by nitrogen caused the surface modification, but the formation of oxide component was found due to the residual gas contamination on the surface. Statistical method of ANOVA was conducted to find the effects of spindle speed and feed rate in interaction for machined surface roughness with PSIIed tools. The surface modification was found largely occurred by the nitrogen implanted surface with 2 hours for 27kV, 35kV and 43kV.

Surface aging and hydrophobicity recovery of silicone rubber by salt fog method (Salt fog 시험법에 의한 실리콘 고무의 표면 열화 및 발수성 회복 특성)

  • 김정호;서광석;문중섭;송우창;이재형;박용관;양계준;유영식
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.7
    • /
    • pp.636-641
    • /
    • 2000
  • The purpose of this study is assessing the characteristics of surface aging and recovery of hydrophobicity for silicone rubber which takes a great interest as outdoor insulation recently subjected to the combined stressed of salt fog and AC power. The methods for assessing are contact angle ATR-FRIR, AFM and XRD. In addition salt fog method is adopted as the artificial contamination experiment and AC power is applied 24 hour on and 24 hour off repeatedly for 5 cycles. The results suggest that degraded surface was more rough than virgin but was restored water repellency through the off cycle. It was due to not only the formation of fractal surface but also maintenance of hydrophobic surface by diffusion of low molecular oil. Although surface recovers initial hydropohbicity there are possibilities of decreasing electrical performance due to irreversable changes such as depolymerization of surface and loss of filler particles. This fact is confirmed by surface conductivity measurement showing that the degradation is significant and the recovery of hydrophobicity is imperfect as the energized cycle increases.

  • PDF

Effects of contamination by either blood or a hemostatic agent on the shear bond strength of orthodontic buttons

  • Gungor, Ahmet Yalcin;Alkis, Huseyin;Turkkahraman, Hakan
    • The korean journal of orthodontics
    • /
    • v.43 no.2
    • /
    • pp.96-100
    • /
    • 2013
  • Objective: To evaluate the effects of contamination by either blood or a hemostatic agent on the shear bond strength (SBS) of orthodontic buttons. Methods: We used 45 freshly extracted, non-carious, impacted third molars that were divided into 3 groups of 15. Each tooth was etched with 37% phosphoric acid gel for 30 s. Human blood or the blood stopper agent was applied to the tooth surface in groups I and II, respectively. Group III teeth were untreated (controls). Orthodontic buttons were bonded to the teeth using light-curing composite resin. After bonding, the SBS of the button was determined using a Universal testing machine. Any adhesive remaining after debonding was assessed and scored according to the modified adhesive remnant index (ARI). ANOVA with post-hoc Tukey's test was used to determine significant differences in SBS and Fisher's exact test, to determine significant differences in ARI scores among groups. Results: ANOVA indicated a significant difference between groups (p < 0.001). The highest SBS values were measured in group III ($10.73{\pm}0.96$ MPa). The SBS values for teeth in groups I and II were significantly lower than that of group III (p < 0.001). The lowest SBS values were observed in group I teeth ($4.17{\pm}1.11$ MPa) (p < 0.001). Conclusions: Contamination of tooth surfaces with either blood or hemostatic agent significantly decreased the SBS of orthodontic buttons. When the contamination risk is high, it is recommended to use the blood stopper agent when bonding orthodontic buttons on impacted teeth.

IMAGING SPECTROMETRY FOR DETECTING FECES AND INGESTA ON POULTRY CARCASSES

  • Park, Bo-Soon;William R.Windham;Kurt C.Lawrence;Smith, Douglas-P
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.3106-3106
    • /
    • 2001
  • Imaging spectrometry or hyperspectral imaging is a recent development that makes possible quantitative and qualitative measurement for food quality and safety. This paper presents the research results that a hyperspectral imaging system can be used effectively for detecting fecal (from duodenum, cecum, and colon) and ingesta contamination on poultry carcasses from the different feed meals (wheat, mile, and corn with soybean) for poultry safety inspection. A hyperspectral imaging system has been developed and tested for the identification of fecal and ingesta surface contamination on poultry carcasses. Hypercube image data including both spectral and spatial domains between 430 and 900 nm were acquired from poultry carcasses with fecal and ingesta contamination. A transportable hyperspectral imaging system including fiber optically fabricated line lights, motorized lens control for line scans, and hypercube image data from contaminated carcasses with different feeds are presented. Calibration method of a hyperspectral imaging system is demonstrated using different lighting sources and reflectance panels. Principal Component and Minimum Noise Fraction transformations will be discussed to characterize hyperspectral images and further image processing algorithms such as image band ratio of dual-wavelength images and its histogram stretching with thresholding process will be demonstrated to identify fecal and ingesta materials on poultry carcasses. This algorithm could be further applied for real-time classification of fecal and ingesta contamination on poultry carcasses in the poultry processing line.

  • PDF