• Title/Summary/Keyword: surface chloride concentration

Search Result 246, Processing Time 0.026 seconds

Corrosion Behavior and Inhibition Studies of AZ31B Magnesium Alloy With and Without Cl- in the Alkaline Electrolytes in Addition with Various Inhibitor Additives

  • Shin, Yoonji;Cho, Kyehyun
    • Corrosion Science and Technology
    • /
    • v.18 no.6
    • /
    • pp.243-252
    • /
    • 2019
  • The pitting corrosion and inhibition studies of AZ31B magnesium alloy were investigated in the alkaline solution (pH12) with chloride and inhibitors. The corrosion behavior of passive film with/without Cl- in the alkaline electrolyte were conducted by polarization curve and immersion tests in the presence of various additives (inhibitors) to clarify the inhibition efficiency of pitting corrosion at higher potential region. Critical concentration of pitting corrosion for Mg alloy was evaluated with 0.005 M NaCl in 0.01 M NaOH on the anodic polarization behavior. Critical pitting of AZ31B Mg alloy in 0.01 M NaOH is a function of chlorides; Epit = - 1.36 - 0.2 log [Cl-]. When the Sodium Benzoate (SB) was only used as an inhibitor, a few metastable pits developed on the Mg surface by an immersion test despite no pitting corrosion on the polarization curve meaning that adsorption of SB on the surface is insufficient protection from pitting corrosion in the presence of chloride. The role of SB and Sodium Dodecylbenzenesulfonate (SDBS) inhibitors for the Mg alloy surface in the presence of chloride was suppressed from pitting corrosion to co-adsorb on the Mg alloy surface with strong formation of passive film preventing pitting corrosion.

Concentration of Sodium Chloride, Sodium Acetate and Sodium Citrate Solutions by using Polyamide Reverse Osmosis Membrane (폴리아미드 역삼투막을 이용한 염화나트륨, 아세트산나트륨, 구연산나트륨 용액의 농축)

  • Lee, Heungil;Kim, In Ho
    • Korean Chemical Engineering Research
    • /
    • v.56 no.5
    • /
    • pp.679-686
    • /
    • 2018
  • Reverse osmosis (RO) concentration of sodium chloride, sodium acetate, and sodium citrate solutions has been performed by polyamide RO membrane. Concentration polarization phenomena was also studied by changing pressure, solute kinds, and initial solution concentration. Pressure effect on permeation flux was that the increase of flux was accompanied by the increase of pressure. Flux increase was observed by the decrease of initial solution concentration. Surface concentration on the RO membrane increases and so flux declines due to the concentration polarization. In the later phase of concentration, concentration polarization effect was decreased by the back diffusion of solute from the polariztion layer. In case of sodium citrate, its large ion size and charge density resulted in the discrepancy between theory and experimental data of concentration polarization. It may be due to electric repulsion on the membrane surface.

Surface Treatment of 304L Stainless Steel for Improving The Pitting Corrosion Resistance by Inhibitor

  • Hue Nguyen Viet;Kwon Sik Chol
    • Journal of Surface Science and Engineering
    • /
    • v.36 no.3
    • /
    • pp.277-283
    • /
    • 2003
  • Electrochemical techniques were used to study the surface treatment for improving the pitting corrosion resistance of 304L stainless steel by inhibitors in chloride medium. Sodium molybdate (in concentration range : 0.005-80 g/l) , sodium nitrite (in concentration range : 0.001-50 g/l) and their mixture were used for this study. It was found that, molybdate and nitrite were good passivators for 304L stainless steel, but molybdate was not able to prohibit the pitting ; nitrite prevented pitting corrosion of 304L stainless steel only at the concentration more than 25 g/l. The relationship between pitting potentials and concentrations of inhibitors in the logarithm expression obeyed the linear function. It was found that the surface treatment by mixture of two inhibitors enables stainless steel to have increased the corrosion resistance , the pitting corrosion of 304L stainless steel was completely prohibited by the mixtures of molybdate and nitrite in ratio min, with $m\;\geq\;3\;and\;n\;\geq\;10$. The interesting cases on electrochemical measurement of threshold of inhibitors concentration combination for optimum surface treatment were described.

Service life prediction of chloride-corrosive concrete under fatigue load

  • Yang, Tao;Guan, Bowen;Liu, Guoqiang;Li, Jing;Pan, Yuanyuan;Jia, Yanshun;Zhao, Yongli
    • Advances in concrete construction
    • /
    • v.8 no.1
    • /
    • pp.55-64
    • /
    • 2019
  • Chloride corrosion has become the main factor of reducing the service life of reinforced concrete structures. The object of this paper is to propose a theoretical model that predicts the service life of chloride-corrosive concrete under fatigue load. In the process of modeling, the concrete is divided into two parts, microcrack and matrix. Taking the variation of mcirocrack area caused by fatigue load into account, an equation of chloride diffusion coefficient under fatigue load is established, and then the predictive model is developed based on Fick's second law. This model has an analytic solution and is reasonable in comparison to previous studies. Finally, some factors (chloride diffusion coefficient, surface chloride concentration and fatigue parameter) are analyzed to further investigate this model. The results indicate: the time to pit-to-crack transition and time to crack growth should not be neglected when predicting service life of concrete in strong corrosive condition; the type of fatigue loads also has a great impact on lifetime of concrete. In generally, this model is convenient to predict service life of chloride-corrosive concrete with different water to cement ratio, under different corrosive condition and under different types of fatigue load.

Correlation between chloride-induced corrosion initiation and time to cover cracking in RC Structures

  • Hosseini, Seyed Abbas;Shabakhty, Naser;Mahini, Seyed Saeed
    • Structural Engineering and Mechanics
    • /
    • v.56 no.2
    • /
    • pp.257-273
    • /
    • 2015
  • Numerical value of correlation between effective parameters in the strength of a structure is as important as its stochastic properties in determining the safety of the structure. In this article investigation is made about the variation of coefficient of correlation between effective parameters in corrosion initiation time of reinforcement and the time of concrete cover cracking in reinforced concrete (RC) structures. Presence of many parameters and also error in measurement of these parameters results in uncertainty in determination of corrosion initiation and the time to crack initiation. In this paper, assuming diffusion process as chloride ingress mechanism in RC structures and considering random properties of effective parameters in this model, correlation between input parameters and predicted time to corrosion is calculated using the Monte Carlo (MC) random sampling. Results show the linear correlation between corrosion initiation time and effective input parameters increases with increasing uncertainty in the input parameters. Diffusion coefficient, concrete cover, surface chloride concentration and threshold chloride concentration have the highest correlation coefficient respectively. Also the uncertainty in the concrete cover has the greatest impact on the coefficient of correlation of corrosion initiation time and the time of crack initiation due to the corrosion phenomenon.

Preparation of Ultrafine Nickel Powders by Wet Reduction Process (습식 환원법에 의한 니켈 미분말의 제조)

  • Lee, Yoon-Bok;Moon, Young-Tae;Shin, Dong-Woo;Kim, Kwang-Ho
    • Korean Journal of Materials Research
    • /
    • v.12 no.10
    • /
    • pp.803-808
    • /
    • 2002
  • Nickel powders were prepared from nickel chloride solution by wet reduction process, and the size control of the particles was investigated with reactant concentration, dispersant agent, and the addition of ethanol as an organic solvent in NiCl$_2$ aqueous solution. The size of the particle decreased with the increase of nickel chloride concentration. Their average particle size were 1.9$\mu\textrm{m}$, 1.6$\mu\textrm{m}$ and $1.5\mu\textrm{m}$ with 0.5M, 0.8M and 1.0M of nickel chloride concentration respectively. The spherical particle was easily controlled by the addition of ethanol as an organic solvent. Especially, in 30 vol% of ethanol, the average particle size and specific surface area were about 0.2$\mu\textrm{m}$ and 8.98m$^2$/g, respectively.

Interaction of Rare Earth Chloride Salts to Alumina and Mullite in LiCl-KCl at 773 K

  • Horvath, David;Warmann, Stephen;King, James;Marsden, Kenneth;Hoover, Robert
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.18 no.3
    • /
    • pp.337-346
    • /
    • 2020
  • Two commonly used ceramics in molten salt research are alumina and mullite. The two ceramics were exposed to a combination of rare earth chlorides (YCl3, SmCl3, NdCl3, PrCl3, and CeCl3; each rare earth chloride of 1.8 weight percent) in LiCl-KCl at 773 K for approximately 13 days. Scanning electron microscopy with wave dispersion spectra was utilized to investigate a formation layer or deposition of rare earths onto the ceramic. Only the major constituents of the ceramics (Al, Si, and O2) were observed during the wave dispersion spectra. X-ray fluorescence was used as well to determine concentration changes in the molten salt as a function of ceramic exposure time. This study shows no evidence of ionic exchange or layer formation between the ceramics and molten chloride salt mixture. There are signs of surface tension effects of molten salt moving out of the tantalum crucible into secondary containment.

Effects of Ultrasonic Waves on Electrodeposition on Nickel-Zinc Alloys(I) (Ni-Zn 합금도금에 미치는 초음파의 영향(I))

  • Yang, Hack-Hui
    • Journal of Surface Science and Engineering
    • /
    • v.20 no.1
    • /
    • pp.4-14
    • /
    • 1987
  • The nickel-zinc alloy depositions have been studied in nickel chloride added chloride baths, to find out the effects of ultrasonic irradiation for the electrodeposition processes. The compositions of deposited alloys, the current efficiencies and the metallographic appearances in various conditions of Electrodeposition were investigated, in the range of ultrasonic irradiation of 50,500 and 1,000 Kc/s respectively. The results obtained are as follows; 1. Generally the nickel deposition process is more preferably activated than that of zinc by the ultrasonic irradiation. 2. The radios of nickel to zinc in the deposit are higher according to increase of nickel ion concentration and bath temperatures in irradiated baths. 3. The current efficiencies are also higher in the irradiated baths, so that the depolarization effect is noticeable. 4. The brightness and leveling effect of the deposits are appreciably better in the irradiated baths than in non-irradiated in 0.3M and 0.6M of nickel chloride and zinc chloride solutions and the current density of 3A/$dm^2$. 5. The mechanism of alloy deposition has been tentatively suggested in the case of ultrasonic irradiation.

  • PDF

Adsorption of Organic Chemical by Coconut Activated Carbon treated with Zinc Salt (아연염으로 표면처리한 활성탄에 의한 수중 유기화합물의 흡착)

  • 김영규;한진수
    • Journal of environmental and Sanitary engineering
    • /
    • v.10 no.1
    • /
    • pp.132-141
    • /
    • 1995
  • The objectives of this study was to find the effect of zinc salt treated with coconut activated carbon and the effect of humic substance. The bottle- Point technique was used in determining the Freundlich isotherm equation. The adsorptive capacity of granular activated carbon was reduced when humic substance are present. Coconut activated carbon was coated with 0.0001 N zinc chloride decreased the BET surface area but increased the adsorptive capacity more than coconut activated carbon not coated with zinc chloride. The adsorptive capacity of TCE in coconut activated carbon coated with higher concentration of zinc chloride was reduced but increased in the solution containing humic substance when the coconut activated carbon was coated with 0.01 N- zinc chloride. The zinc salt coated with coconut activated carbon did not Increase the adsorptive velocity of coconut activated carbon.

  • PDF

Probabilistic time-dependent sensitivity analysis of HPC bridge deck exposed to chlorides

  • Ghosh, Pratanu;Konecny, Petr;Lehner, Petr;Tikalsky, Paul J.
    • Computers and Concrete
    • /
    • v.19 no.3
    • /
    • pp.305-313
    • /
    • 2017
  • A robust finite element based reinforced concrete bridge deck corrosion initiation model is applied for time-dependent probabilistic sensitivity analysis. The model is focused on uncertainties in the governing parameters that include variation of high performance concrete (HPC) diffusion coefficients, concrete cover depth, surface chloride concentration, holidays in reinforcements, coatings and critical chloride threshold level in several steel reinforcements. The corrosion initiation risk is expressed in the form of probability over intended life span of the bridge deck. Conducted study shows the time-dependent sensitivity analysis to evaluate the significance of governing parameters on chloride ingress rate, various steel reinforcement protection and the corrosion initiation likelihood. Results from this probabilistic analysis provide better insight into the effect of input parameters variation on the estimate of the corrosion initiation risk for the design of concrete structures in harsh chloride environments.