• Title/Summary/Keyword: suppress

Search Result 3,149, Processing Time 0.025 seconds

Design of a Robust TCSC Supplementary Controller to Suppress SSR in FACTS (유연송전시스템(FACTS)에서의 SSR 억제를 위한 강인한 TCSC 보조 제어기의 설계)

  • Seo, Jang-Cheol;Kim, Tae-Hyun;Moon, Seung-Ill;Park, Jong-Keun
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.884-886
    • /
    • 1998
  • This paper presents an LQG based robust TCSC supplementary controller design to suppress the SSR in the FACTS. This controller is designed to have the robust stability against the plant model uncertainty. The robust stability is guaranteed using the $\mu$ analysis. Time domain simulations using a nonlinear system model show that the proposed TCSC supplementary controller can suppress the SSR efficiently against the plant model uncertainty.

  • PDF

Automatic Tuning of Notch Filter to Suppress Oscillations in a PMLSM Drive (선형 영구자석 동기전동기 구동장치의 진동억제를 위한 노치필터 자동조정)

  • Lee, Jin-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.409-411
    • /
    • 2007
  • This paper deals with an automatic tuning method of the notch filter to suppress oscillations in a permanent magnet linear synchronous motor(PMLSM) drive. First, it saves automatically the reference torque-component current when oscillations are detected. Then the oscillation frequency of the saved data is calculated by using the fast Fourier transform(FFT) algorithm. And also the Hanning function is used to reduce the leakage components due to the aperiodic measurement data. Finally, the proposed method tunes the notch filter to suppress oscillations. Experimental results on the test rig show the validity of the proposed method.

  • PDF

Sizing of a tube inlet orifice of a once-through steam generator to suppress the parallel channel instability

  • Yoon, Juhyeon
    • Nuclear Engineering and Technology
    • /
    • v.53 no.11
    • /
    • pp.3643-3652
    • /
    • 2021
  • Sizing the tube inlet orifice of a Once-Through Steam Generator (OTSG) is important to protect the integrity of the tubes from thermal cycling and vibration wear. In this study, a new sizing criterion is proposed for the tube inlet orifice to suppress the parallel channel instability in an OTSG. A perturbation method is used to capture the essential parts of the thermal-hydraulic phenomena of the parallel channel instability. The perturbation model of the heat transfer regime boundaries is identified as a missing part in existing models for sizing the OTSG tube inlet orifice. Limitations and deficiency of the existing models are identified and the reasons for the limitations are explained. The newly proposed model can be utilized to size the tube inlet orifice to suppress the parallel channel instability without excessive engineering margin.

Design and fabrication of a novel multilayer bandpass filter with high-order harmonics suppression using parallel coupled microstrip filter

  • Fathi, Esmaeil;Setoudeh, Farbod;Tavakoli, Mohammad Bagher
    • ETRI Journal
    • /
    • v.44 no.2
    • /
    • pp.260-273
    • /
    • 2022
  • This study presents a novel multilayer structure of parallel coupled-line bandpass filtercentered at 2.42 GHz with a fractional bandwidth value of approximately 19.4%. The designed filter can suppress harmonics with an appropriate frequency response by incorporating different techniques based on the multilayer technique. A combination of different techniques such as radial microstrip stubs and defected ground structure (DGS) and defected microstrip structure techniques are employed to suppress harmonics up to 5f0. These techniques are used in two layers to suppress up to 5f0. In addition, in this study, the effects of different parameters, such as the width of slot-line DGS, the angle of diagonal line slots in the upper layer, and the air gap between the two layers on the filter performance, are investigated. To verify the correct circuit operation, the designed filter is implemented and tested. The measurement results of the proposed filter are compared with the simulation results.

PN Code Acquisition in a DS/CDMA Overlay Environment

  • Kim, Jin-Young
    • Proceedings of the IEEK Conference
    • /
    • 2000.06a
    • /
    • pp.185-188
    • /
    • 2000
  • In this paper, performance of a PN code acquisition scheme is analyzed and simulated for a DS/CDMA overlay system where a CDMA user and a narrowband user coexist in the same frequency band. To suppress the NBI, an interference suppression filter is employed at the receiver front-end. From the simulation results, it is shown that the interference suppression filter is very effective for suppression of the NBI and rapid PN code acquisition in a DS/CDMA overlay environment. It is also shown that the one-sided tap number of 5 fur interference suppression filter is sufficient to suppress the NBI.

  • PDF

Density Fluctuation of Tetranychus urticae and Three Predatory Mite Species(Phytoseiidae) by the Differently Infested Levels (점박이응애와 천적인 3종 이리응애의 접종수준별 밀도 변동)

  • 이영인;권기면;이순원;류하경;류언하
    • Korean journal of applied entomology
    • /
    • v.36 no.3
    • /
    • pp.237-242
    • /
    • 1997
  • Comparative studies on suppression possibility with three phytoseiid mite species (An.thly,seiu,sw omersleyi Schicha. A. ,fidIrrc~i.Gs arman and T\ulcornerphlorlrotiiu.s oc~c~idetitaliNs esbit) to the two-spotted spider mite (Te~trrrt~yc.Iir~l~l\ulcorner.i\c .(re Kwh) on kidney bean leaves in field and greenhouse were carried out. In the field experiments with the initial prey -predator ratio of 4 : 1. I0 : I and 20: I . A. ,firllrrcis suppressed successfully the prey populations at all three ratios 17 days after the initial infestation. A. wornc,r-;leyi \uppressed the prey population only at the ratio of 4 : 1, while T. oc~c~ideritcr1iw.s as unable to suppress the prey population at all tested ratios. In the greenhouse experiments with the initial prey-predator ratio of 10: 1, A. jil1ltrci.s could suppress the prey population continuously during the infestation period. A. ~~otnc~r,slceoyuil d suppress the prey population for 13 days after the initial infestation, while T. occie1mttrli.s could suppress the prey population for 8 - 23 days after the initial infestation.

  • PDF

The Immuno-Regulatory Effects of Onbi-tang and Dangguijakyak-san in Minimal Change Nephrotic Syndrome (미세변화 현증후군에서 온비탕과 당귀작약산이 면역조절기능에 미치는 영향)

  • 안영민;안세영;두호경
    • The Journal of Korean Medicine
    • /
    • v.21 no.1
    • /
    • pp.20-28
    • /
    • 2000
  • The purpose of this research is to investigate the synergistic effect of herb medicines with hydrocortisone and the regulation effect on the immune system of Onbitang and Dangguijakyaksan at the supernatant of PHA-P stimulated PBMC in the patients with minimal change nephrotic syndrome(MCNS). From the measurement of the concentration rate of IL-4, sCD23 and IL-13, the experiment yielded the following results : The Onbitang group showed a greater tendency to suppress IL-4 and IL-13 levels in MCNS group with no statistical significance. It showed very strong suppression in soluble CD23 compared with control group in MCNS group. The Dangguijakyaksan group, though not statistically significant, was inclined to suppress IL-4 level in MCNS group. It shows stronger suppression in sCD23 and IL-13 levels than these of control group in MCNS group. As for the synergistic effect, the group of hydrocortisone with herb medicines(Onbitang or Danguijakyaksan) produced more suppressive effect to IL-13 level in MCNS group than that of hydrocortisone-only group. They also tended to suppress sCD23 and IL-4 levels, though no statistical significance can be given. As to the suppressive effect of 1L-13 level, the group of Onbitang with hydrocortisone showed an increase of 22.6%, while the group of Dangguijakyaksan with hydrocortisone showed 14.7%. So Onbitang is more effective than Dangguijakyaksan. From the above results, a combinative treatment(herb medicines with hydrocortisone) can be an alternative method to substitute for steroid therapy. It can be a more effective therapy than steroid-only therapy because it is expected to reduce side effects and it shows more special effect to suppress IL-13 level. Based on the present results, further investigation concerning the serum IgE elevation is needed.

  • PDF

Performance Analysis of a Cold Inert Gas Generator (비황성가스제너레이터 성능분석)

  • 김수용
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.3 no.2
    • /
    • pp.75-81
    • /
    • 1999
  • Present study deals with performance analysis of a cold inert gas generator which is to be used as an effective and prompt mean to suppress the fire. Every year, squandering of numerous People and assets by fire have been noticed around us. However, there seemed not enough progresses made to suppress the fire effectively for the past few centuries. Present study introduces CIGG(Cold Inert Gas Generator), basically a new conceptual approach to suppress the fire, through performance analysis of the machine and tried to suggest basic specifications of the heat exchanger which is a vital part of the machine, while at the same time, revealing the basic performance of the CIGG in the form of a design point.

  • PDF

A Double Bi-Quad Filter with Wide-Band Resonance Suppression for Servo Systems

  • Luo, Xin;Shen, Anwen;Mao, Renchao
    • Journal of Power Electronics
    • /
    • v.15 no.5
    • /
    • pp.1409-1420
    • /
    • 2015
  • In this paper, an algorithm using two bi-quad filters to suppress the wide-band resonance for PMSM servo systems is proposed. This algorithm is based on the double bi-quad filters structure, so it is named, "double bi-quad filter." The conventional single bi-quad filter method cannot suppress unexpected mechanical terms, which may lead to oscillations on the load side. A double bi-quad filter structure, which can cancel the effects of compliant coupling and suppress wide-band resonance, is realized by inserting a virtual filter after the motor speed output. In practical implementation, the proposed control structure is composed of two bi-quad filters on both the forward and feedback paths of the speed control loop. Both of them collectively complete the wide-band resonance suppression, and the filter on the feedback path can solve the oscillation on the load side. Meanwhile, with this approach, in certain cases, the servo system can be more robust than with the single bi-quad filter method. A step by step design procedure is provided for the proposed algorithm. Finally, its advantages are verified by theoretical analysis and experimental results.

Effective Power/Ground Network Design Techniques to suppress Resonance Effects in High-Speed/High-Density VLSI Circuits (고속/고밀도 VLSI 회로의 공진현상을 감소시키기 위한 효율적인 파워/그라운드 네트워크 설계)

  • Ryu Soon-Keol;Eo Yung-Seon;Shim Jong-In
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.43 no.7 s.349
    • /
    • pp.29-37
    • /
    • 2006
  • This paper presents a new analytical model to suppress RLC resonance effects which inevitably occur in power/ground lines due to on-chip decoupling capacitor and other interconnect circuit parasitics (i.e., package inductance, on-chip decoupling capacitor, and output drivers, etc.). To characterize the resonance effects, the resonance frequency of the circuit is accurately estimated in an analytical manner. Thereby, a decoupling capacitor size to suppress the resonance for a suitable circuit operation is accurately determined by using the estimated resonance frequency. The developed novel design methodology is verified by using $0.18{\mu}m$ process-based-HSPICE simulation.