• Title/Summary/Keyword: supply pressure

Search Result 1,231, Processing Time 0.022 seconds

Pressure restricted water supply method during drought using a computer simulation and daily water supply analysis (시뮬레이션과 1일 급수량 분석을 이용한 갈수기 감압에 의한 제한급수 방법)

  • Nam, Youngwook;Kim, Kyungsu;Hyun, Inhwan;Kim, Dooil
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.34 no.5
    • /
    • pp.335-344
    • /
    • 2020
  • Due to global climate change, mega-droughts have occurred frequently. Since long-term droughts make it difficult to secure the water resources, water supply needs to be restricted in a reasonable manner. In the event of limited water supply, the waterworks need to develop a restricted water supply strategy. This study showed that analyzing daily water supply could be used to respond to the first stage of a drought. According to an analysis of Korea's major water authorities, there was about 7~21% of room for daily minimum water supply in case of a drought. Restricting the water supply by lowering pressure is a good strategy for local water authorities with high water leakage rate since leakage is inversely dependent with pressure. For this method, it is necessary to quantify water deficiency and pressure at each node using a simulation. Since DDA-based software is not possible to predict changes in demand at nodes with pressure reduction, WaterGEMS, a PDA software, was used to quantitatively predict water shortages and pressures at each node. Locations where water is deficient need to install booster pumps or to be dispatched with water tank truck and bottled water. Without these support, lowering pressure could not be an option for water works. This paper suggests a method for waterworks to plan a drought by lowering pressure to restrict water supply using daily water supply analysis and PDA based simulation.

A Study on the Flow rate Analysis of a Sanitary Fixture for Water Supply Piping System (급수배관방식에 따른 욕실 위생기구의 유량분석에 관한 연구)

  • JANG, Y.K.;KIM, D.J.;SUH, B.T.
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.4
    • /
    • pp.9-14
    • /
    • 2011
  • The flow rate analysis for sanitary fixtures has been studied to determine the water supply piping system and size. The study has been carried out to analyze for a various water supply pressure and piping size theoretically. Also, the study has been carried out to analyze for a various water supply piping system experimentally. The water supply pressure is varied from 0.01MPa to 0.07MPa, and the piping size is varied from 6mm to 15mm. The water supply piping systems are one-to-one, all-loop-type, and bathroom-loop-type water supply piping system. The results indicate that the piping size is able to supply water fully in case of smaller than 15mm if the water supply pressure keep an necessary minimum pressure. And the gap of flow rate is very little for the various water supply piping systems.

A Study on Feasibility Analysis and Optimum Range Calculation Model by Conversion of Water Supply System (상수도 급수방식 전환의 타당성 분석 및 최적 범위 산정모델 연구)

  • Park, Junyeol;Shin, Hwisu;Seo, Jeewon;Kim, Kibum;Koo, Jayong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.2
    • /
    • pp.177-186
    • /
    • 2017
  • This study concerned the analysis on the efficiency of the conversion of water tank type supply system to direct water supply system to examine the feasibility of the conversion, as well as the calculation of optimal conversion range that enables the supply of safe, high-quality water at stable pressure in accordance with the standards of water supply facility. The results of this research showed that when converting water supply system from water tank type supply system to direct water supply system, more nodal points could be properly converted and more reduction of electricity usage was expected in case water pressure rather than residence time was fixed. This means that higher efficacy can be obtained by fixing water pressure when converting water supply system. However, since the number of the locations that received on-spot inspection was small and the electricity usage measured was not exclusively by water supply facility, it is difficult to judge that such reduction of electricity usage accurately represents reduced electricity usage by water supply facility alone. therefore, after having secured on-spot information about a larger number of locations in apartment complexes that have converted water supply system, and utilizing information about electricity usage exclusively by water supply facility, the proposed method of this research could be applied to accurately deducing expected reduction of electricity usage by water supply facilities of various other apartment complexes. It is also considered possible to deduce an effective operation method of water supply system by finding out an area that shows low pressure or low residual chlorine concentration in the optimal conversion range of water supply, followed by estimating the proper location of pumping station or the proper chlorine dosage at the power purification plant that supply water to the target area.

Development of Supply System Module for Liquid Rocket Engine (액체로켓엔진 공급시스템 모듈 개발)

  • Kim, Hye-Min;Lee, Sang-Bok;Kim, Wan-Jo;Roh, Tae-Seong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.79-84
    • /
    • 2010
  • The supply system module of the liquid rocket engine has been developed, which consists of the various supply system components such as pipes, orifices, elbows, bellows, valves and flanges. This module can size the components and calculate pressure drops between them. For the assembly of the supply system components, the supply system module can evaluate the number of the components, total pressure drop, outlet pressure and total system weight.

  • PDF

Investigation of Control Theory on Pressure Drop Characteristics of Pneumatic Regulator for Gas Supply (공압 레귤레이터의 공급압력 강하 제어이론에 대한 고찰)

  • Cho, Nam-Kyung;Chung, Yong-Gahp;Cho, In-Hyun
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.15 no.2
    • /
    • pp.74-83
    • /
    • 2011
  • For launcher applications, different from other applications, very high flow rate is required which can lead to supply pressure drop against required setting pressure. The supply pressure decrease is closely related to regulator characteristics. In this paper, supply pressure offset is investigated considering regulators as kinds of control systems. Pressure offset of self-operated regulator is analyzed with sensitive parameter defined as the ratio of valve travel to pressure offset. It is shown that pressure offset of self-operating regulator can be improved by incorporating proportional and integral controls and they can be materialized with pilot regulator systems.

Pressure Drop Characteristics and Control Method of Pneumatic Regulator for Gas Supply (공압 레귤레이터의 공급시 압력강하 특성 및 제어방법)

  • Cho, Nam-Kyung;Chung, Yong-Gahp;Nam, Jung-Won;Cho, In-Hyun
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.347-352
    • /
    • 2009
  • Pneumatic system is widely applied to ground facility and launcher on-board system. The main requirements of pneumatic system is to meet pressure and flow requirements of gas consumers. For launcher related applications, different from other applications, very high flow is required which can leads to supply pressure drop against required setting pressure. The supply pressure decrease is closely related to regulator characteristics. In this paper, the characteristics of pneumatic regulator related to supply pressure decrease and the control methods for reducing the pressure offset are reviewed.

  • PDF

Influence of Pressure Reducing Valves on Flow Characteristics of the Water Supply System for an Apartment Complex (공동주택단지 급수계통의 유량특성에 미치는 감압밸브의 영향)

  • Kim, Tae Jin;Cha, Dong Jin
    • KIEAE Journal
    • /
    • v.12 no.6
    • /
    • pp.23-28
    • /
    • 2012
  • Pressure distribution in the water supply system of an apartment complex consisting of 12 buildings and 635 units in total have been investigated numerically. The complex incorporates two zone booster pump system, and around a half of units have pressure reducing valves (PRVs) in them. Calculated hydrostatic pressure without the water flow were compared with their designed and measured counterparts, and they agreed quite well with each other. Then, the pressure and volumetric water flow rate at all units were analyzed, indicating that there are noticeable differences in pressure and flow rate in one unit to another, although the aforementioned minimization technologies of pressure deviation were employed. In order to further reduce the difference in the water flow rate, it is suggested that all the units in the complex have PRVs installed in their water supply system. The effect of setting pressure of the PRVs on the non-uniformity of the flow in each unit and on the reduction of total water supply for the apartment complex have been studied. With the same PRV setting pressure of 3.952 bar (or the gauge pressure of $3.0kg_f/cm^2$), it has been estimated that the suggested system improves the non-uniformity (the coefficient of variation) of the flow rate of apartment complex over the current system, from 8.02% to 6.66%, and reduces the total water supply, from $0.02804m^3/s$ to $0.02766m^3/s$.

A Study on the Cavitation in a Journal Bearing with Pressurized Lubricant Supply. (가압급유상태의 저어널베어링에서의 유막파단에 관한 연구)

  • Kim, Kyung-Woong;Moon, Woo-Sik
    • Tribology and Lubricants
    • /
    • v.2 no.2
    • /
    • pp.44-51
    • /
    • 1986
  • An experimental investigation is carried out to Study the cavitation in a journal bearing with pressurized lubricant supply. Visual observations are performed at various shaft speeds and supply pressure levels. Oil film pressure is measured at various shaft speeds under the submerged condition. Results from visual observations show that the extent of cavitation is reduced as supply pressure increases. The film pressure measurements indicate the occurrence of a negative pressure loop upstream of the cavitation region and a constant cavitation Pressure through the cavitation region.

The Effect of Oil Supply Pressure on the Performance of Vapor Cavitated Short Squeeze Film Dampers (증기 공동현상이 발생하는 무한 소폭 스퀴즈 필름 댐퍼 성능과 오일 공급압력의 영향)

  • Jung, Si-Young
    • Tribology and Lubricants
    • /
    • v.24 no.3
    • /
    • pp.147-153
    • /
    • 2008
  • The effect of oil supply pressure on the performance of vapor cavitated short squeeze film dampers is examined. Vapor cavitation is characterized by film rupture occurring as a result of evaporating oils. The pressure of vapor cavity in the film is almost zero in absolute pressure and nearly constant. Pan's model about the shape of vapor cavity is utilized for studying the effect of vapor cavitation on the damping capability of a short squeeze film damper. As the level of oil supply pressure is increasing, vapor cavitation is suppressed so that the direct damping coefficient increases and the cross coupled damping coefficient decreases. Futhermore, the analysis of the unbalance responses of a rigid rotor supported on cavitated squeeze film dampers shows that a significant reduction in rotor amplitude and force transmissibility is possible by controlling the oil supply pressure into short squeeze film dampers.

Evaluation of Emergency Water Supply Plan for Block System of Water Network using WaterGEMS (WaterGEMS모형을 이용한 상수관망 블록시스템의 비상급수계획 평가)

  • Baek, Chun-Woo;Jun, Hwan-Don;Kim, Joong-Hoon;Yoo, Do-Guen;Lee, Kwang-Choon
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.6
    • /
    • pp.15-20
    • /
    • 2008
  • Hydraulic analysis of water distribution system can be divided into demand-driven analysis and pressure-driven analysis. Demanddriven analysis can give unrealistic results to simulate hydraulic conditions under abnormal operating conditions such as sudden demand increase and pipe failure. In Korea, demand-driven analysis has been used to establish emergency water supply plan in many water projects, but it is necessary to use pressure-driven analysis for establishment of emergency water supply plan. In this study, WaterGEMS model that was developed for pressure-driven analysis is used to evaluation of emergency water supply plan of J city. As the results, it was able to draw up more efficient plan for water supply in small block, and established emergency water supply plan of J city was determined to be appropriate.