• 제목/요약/키워드: superconducting bar

검색결과 22건 처리시간 0.036초

유기금속염을 이용한 전력 전송용 초전도체 합성 (Synthesis of high functional Superconducting Precursor using Organic metal salts method for Electric power transmission)

  • 이상헌
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 추계학술대회 논문집 Vol.18
    • /
    • pp.348-349
    • /
    • 2005
  • An electromagnetic memory effect observed in superconducting YBCO system was studied. From the measurement of differential conductance, it was cleared that the mechanism of electromagnetic memory can not be explained by using conventional flux flow model. By changing the density of external magnetic flux, changes in inductance of a coil in which a superconducting bar is inserted were also measured. It was concluded that the electromagnetic memory effect aries from the interaction between the trapped magnetic flux and the weak link of the filament formed in the superconducting bar.

  • PDF

중성자 조사를 위한 초전도 선재의 특성 (Electric Properties of YBCO Superconductor for Neutron Irradiation)

  • 이상헌
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 추계학술대회 논문집 Vol.19
    • /
    • pp.182-183
    • /
    • 2006
  • An electromagnetic memory effect observed in superconducting YBCO system was studied. From the measurement of differential conductance, it was cleared that the mechanism of electromagnetic memory can not be explained by using conventional flux flow model. By changing the density of external magnetic flux, changes m inductance of a coil in which a superconducting bar is inserted were also measured. It was concluded that the electromagnetic memory effect aries from the interaction between the trapped magnetic flux and the weak link of the filament formed in the superconducting bar.

  • PDF

YBCO 세라믹의 전기적 특성 (Electric Properties of YBCO Superconductor)

  • 이상헌
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.292-293
    • /
    • 2005
  • An electromagnetic memory effect observed in superconducting YBCO system was studied. From the measurement of differential conductance, it was cleared that the mechanism of electromagnetic memory can not be explained by using conventional flux flow model. By changing the density of external magnetic flux, changes in inductance of a coil in which a superconducting bar is inserted were also measured. It was concluded that the electromagnetic memory effect aries from the interaction between the trapped magnetic flux and the weak link of the filament formed in the superconducting bar.

  • PDF

Bi계 고온 초전도 선재 부스바에서의 자기 자장 해석 (Analysis of Self Magnetic Field Effects in a Bi-2223 Stacked Superconducting Bus Bar)

  • 강형구;나완수;주진호;유재무;오상수;류강식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 A
    • /
    • pp.302-304
    • /
    • 1998
  • Self magnetic field in a Bus bar usually degrades the critical current in it. Actually the total critical current of a Bus bar is not the same as the sum of total critical current of each stacked HTS tape. This is due to the self field effects in a bus bar. To reduce the degradations of critical current in a bus bar, we need to analyze the self field distributions in a bus bar. Conceptually, by rearranging the each stacked tapes, the self field effects can be minimized. In this paper, we calculate the self magnetic field distributions across a bus bar analytically, with the variations of the relative angle of the two conductors in a go-and-return pair. As a result, we suggest that the optimum relative angle exist which minimize the self field effect in a bus bar.

  • PDF

Mechanism of the Voltage Occurrence in BSCCO Superconductor for Neutron Irradiation

  • Lee, Sang-Heon
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 2006년도 Extended Abstracts of 2006 POWDER METALLURGY World Congress Part2
    • /
    • pp.1093-1094
    • /
    • 2006
  • Magnetic characteristics observed in BiSrCaCuO superconductor were studied. In the measurement of differential conductance, it was cleared that the mechanism of magnetic memory effect couldn't be explained by using conventional flux flow model. By changing the density of external magnetic flux, changes in inductance of a coil in which a superconducting bar inserted were also measured. The results showed that the filament model was valid to explain the mechanism of the occurrence of a voltage in superconducting sample. It was concluded that the electromagnetic characteristics arose from the interaction between the trapped magnetic flux and weak link of the filament formed in the superconducting bulk.

  • PDF

Brief review of the field test and application of a superconducting fault current limiter

  • Hyun, Ok-Bae
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제19권4호
    • /
    • pp.1-11
    • /
    • 2017
  • This article reviews the recent activities of field testing and application of superconducting fault current limiters (SFCL) based on high-temperature superconductors (HTS). The review particularly focuses on the trends in the field tests in terms of the technical aspects and commercial activities of the SFCLs. Stimulated by the discovery of HTS, numerous research and development activities have been conducted worldwide for SFCLs operating from distribution voltages to transmission voltages. Different types of SFCLs have been developed and field-tested. Consequently, more than 20 field tests and applications have been performed on real grids worldwide while supplying electric power to the customers. These field tests have not only provided the track records of the operation experiences including the problems and maintenance during operation, but also proved their current limiting capabilities against real faults, rendering this new technology highly viable. Through these activities, the following trends in the status of field testing and application are observed. Resistive-type SFCLs with HTS-coated conductors were dominantly used in the most recent field tests. This implies that the resistive type is technically more mature than the other types. Bus-bar coupling and transformer feeders were the major application locations. It is of importance that most of the field applications were conducted as R&D projects. A relevant change from the R&D stage to the application stage is shown as recently deployed SFCLs are expected to be under long-term operation and commercial service. Here, we review the installation of these SFCLs by substation. This review also discusses the recent activities for their commercial applications.

4 K GM 극저온냉동기를 이용한 헬륨 재응축형 극저온용기의 성능 평가시험 (Test of evaluating performance of Helium recondensing type cryostat with 4 K GM cryocooler)

  • 김형진;김성래;심기덕;진홍범;권영길;장호명;이봉근
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2002년도 학술대회 논문집
    • /
    • pp.77-81
    • /
    • 2002
  • The helium recondensing type cryostat with 4 K GM cryocooler is fabricated in order to keep cryogenic state of two saddle type superconducting magnet opposite to each other designed maximum 0.3 T magnetic field, and 1270 mm diameter open bore. The current leads which consist of metal current leads made for brass sheet and HTS current leads made in American Superconductor$^{TM}$ intermediate cool down with cryocooler Thus , the cryocooler for helium recondensing is a 1.5W/4.2 K GM SUMITOMO cryocooler. While superconducting magnet is working of 1600 gauss to 200 A, the cryostat keep constantly the level of liquid helium at 0.05 bar gauge pressure.e.

  • PDF

154 kV 초전도 한류기 모선연계 적용 연구 (Investigation of the Feasibility of a Bus-bar coupled SFCL in the 154 kV KEPCO Grid)

  • 윤용범;현옥배;황시돌;김혜림
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 추계학술대회 논문집
    • /
    • pp.291-293
    • /
    • 2003
  • Applicability and economical feasibility of a Superconducting Fault Current Limiter (SFCL) have been investigated using the PSS/E simulation for a bus bar coupling at the real 154 ㎸ KEPCO power grid near Seoul. For the investigated substation, the maximum fault current exceeds the interruption rating of 4 circuit breakers (CB) out of 9 installed in the substation. The simulation showed that a SFCL installed in the bus tie position effectively limits the fault currents to save 4 CBs, which are to be replaced by ones of gloater interruption rating, otherwise. We suggest that the optimum resistance of the SFCL be 10 Ohm for the given grid.

  • PDF

전기화학 프로세스에 의한 Carbon 특성 (Electric Properties of Carbon Using Electrochemical Process)

  • 이상헌
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 추계학술대회 논문집 Vol.19
    • /
    • pp.388-389
    • /
    • 2006
  • Electro-deposition of carbon film on silicon substrate in methanol solution was carried out with various current density, solution temperature and electrode spacing between anode and cathode. The carbon films with smooth surface morphology and high electrical resistance were formed when the distance between electrode was relatively wider. The electrical resistance of the carbon films were independent of both current density and solution temperature.

  • PDF

An Investigation on Surface Flashover Characteristics of FRP in Several Insulation Gases for the Spacer of Cryogenic Bushing

  • Hwang, Jae-Sang;Shin, Woo-Ju;Seong, Jae-Kyu;Lee, Jong-Geon;Lee, Bang-Wook
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제14권4호
    • /
    • pp.20-23
    • /
    • 2012
  • Superconducting equipment has been actively investigated for securing the environment and energy technology (ET) in various parts of the world. Despite these movements, a high voltage cryogenic bushing, which plays an important role of interconnection between the electric power systems and superconducting devices, has not been fully developed due to severe insulation requirements. A gas insulated cryogenic bushing has been investigated as one of our projects since 2010. As a basic step to obtain the design parameters for cryogenic bushing, we focused on the surface flashover characteristics of glass fiber reinforced plastic (FRP) in several insulation gases. For the surface flashover tests, several insulation gases including $SF_6$, $CF_4$ and $N_2$ gas were prepared. Various length of FRP specimens were fabricated in order to obtain the fundamental data for creepage distance of FRP. The first specimen group was from 2 mm to 10 mm with 2 mm intervals and the second specimen group was from 20 mm to 100 mm with 20 mm intervals. And the gas pressure was varied from 1 bar to 4 bar. An AC overvoltage test and a lightning impulse test were performed. Then the experimental results of surface flashover were obtained and analyzed. Based on these results, it would be possible to design the optimum creepage distance of FRP in a cryogenic bushing.