• Title/Summary/Keyword: sun sensor

Search Result 1,249, Processing Time 0.036 seconds

Evaluation of compensator to reduce thermal sensation in oncological hyperthermia (고주파 온열암 치료 시 열감감소를 위해 자체 제작한 보상체의 유효성 평가)

  • Lee, Yeong Cheol;Kim, Sun Myung;Jeong, Deok Yang;Kim, Young Bum
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.27-32
    • /
    • 2017
  • Objectives: Oncological hyperthermia is a treatment to selectively kill cancer cells by directly applying heat to cancer cells or indirectly demage cancer cells. One of the most side effects of treatment is burn that can appear on the skin. In areas with irregularities such as the umbilicus, the patient feels a sense of hot and treatment may be discontinued. Therefore, in order to eliminate the irregularities of these areas, compensators are manufactured and measured to decrease in temperature. Materials and Methods: The temperature of the four sites (umbilicus, near the umbilicus, 5 cm below the umbilicus, back) was measured five times around the umbilicus in patients who were treated at oncological hyperthermia treatment device(EHY-2000, Oncotherm Kft, Hungary). The temperature sensor (TM-100, Oncotherm Kft, Hungary) was attached to four sites and the changes were observed at 5, 15, 25, 35, and 50 minutes after treatment. Compensators of three materials were used(Vaseline, Bolus, Dental resin). The data measured five times were compared for each compensator. Results: The temperature change when the compensator was not used increase from 34.65 degrees to 42.9 degrees on average. The near umbilicus was changed from 32.20 degrees to 37.00 degrees, and the 5 cm below the umbilicus was changed from 31.90 to 34.41 degrees. When the compensator material was inserted into the umbilicus, the temperature change was measured as 5.42 degrees for bolus, 6.55 degrees for vaseline, and 6.83 degrees for resin. Conclusion: Using the compensator in the region where the irregularities such as the umbilicus, the heat sensation could be reduced. the use of a resin that can be customized not only lowers the temperature but also significantly reduces the feeling of the patient. It will be possible to reduce the heat sensation in the treatment and to treat it in a more comfortable condition.

  • PDF

Spatial Distribution of Pigment Concentration Around the East Korean Warm Current Region Derived from Satellite Data - Satellite Observation in May 1980 - (위성원격탐사에 의한 동한난류 주변 해역의 색소농도 공간적 분포 -1980년 5월 관측을 중심으로 -)

  • Kim Sang Woo;Saitoh Sei-ich;Kim Dong Sun
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.35 no.3
    • /
    • pp.265-272
    • /
    • 2002
  • Spatial distribution of Phytoplankton Pigment Concentration (PPC) and Sea Surface Temperature (SST) around the East Korean Warm Current (EKWC) was described, using both Coastal Zone Color Scanner (CZCS) images and Advanced Very High Resolution Radiometer (AVHRR) images in May, 1980. Water mass in this region can be classified into five categories in the horizontal profile of PPC and SST, nLw (normalized water-leaving radiance) images: (1) coastal cold water region associated with concentrations of dissolved organic material or yellow colored substances and suspended sediments, (2) cold water region of thermal frontal occurred by a combination of phytoplankton absorption and suspended materials, (3) warm water overlay region by the phytoplankton absorption than the suspended materials; (4) warm water region occurred by the low phytoplankton absorption, and (5) offshore region occurred by the high phytoplankton absorption. In particular, the highest PPC (>2.0 mg/m^3) area appeared in the CZCS and AVHRR images with a band shaped distribution of the thermal front and ocean color front region, which is located the coastal cold waters alonB western thermal front of the warm streamer of the EKWC. In this region, the highest PPC occurred by a combination of the high absorption of the phytoplankton (443 nm) and highest reflectance of suspended materials (550 nm). Another high PPC ($\simeq$$6\;mg/m^3$) appeared in the warm water overlay region inside warm streamer. High phytoplankton pigment concentration of this region was corresponding to the short wavelength of 443 nm, which represented phytoplankton absorption of the CZCS image.

The Analysis of Estrus Behavior and the Evaluation of Conditions Required for Improving Reproductive Efficiency in Holstein Dairy Cows using a Heat Detector (발정탐색기를 이용한 Holstein 젖소의 발정행동 분석 및 번식효율 향상을 위한 조건의 평가)

  • Baek, Kwang-Soo;Lee, Wang-Shik;Son, Jun-Kyu;Lim, Hyun-Joo;Yoon, Ho-Beak;Kim, Tae-Il;Hur, Tai-Young;Choe, Chang-Yong;Jung, Young-Hun;Kwon, Eung-Gi;Jung, Yeon-Sub;Kim, Sun-Kyu;Won, Jeong-Il
    • Journal of Embryo Transfer
    • /
    • v.28 no.3
    • /
    • pp.177-184
    • /
    • 2013
  • The objective of this study was to analyze the accuracy of estrus detection of heat detector and analysis of estrus behavior (mounting and mounted), and the evaluation of conditions required for improving reproductive efficiency in Holstein dairy cows fitted with a estrous detector. The heat detection system consists of estrous detector based on wireless sensor and an electric bulletin board displayed estrus behavior data. When cow mounting other cows, the accuracy of estrus behavior displayed an electric bulletin board were 87.5% (mounting other cows only), 100% (mounting other cows but not standing), 80.0% (mounting other cows with standing for 1~4 seconds), 90.0% (mounting other cows but not standing for 1~4 seconds), 80% (mounting other cows with standing for more than 5 seconds) and 90.0% (mounting other cows but not standing for more than 5 seconds). When cow mounted other cows, the accuracy of estrus behavior displayed an electric bulletin board were 100% (mounted other cows but not standing), 100% (mounted other cows with standing for 1~4 seconds), 100% (mounted other cows but not standing for 1~4 seconds) and 100% (mounted other cows with standing for more than 5 seconds). Circadian distribution of first observed in estrus were 59.1% (am 8~pm 6) and 40.9% (pm 6~am 8). Distribution for the number of estrus behavior were 40.9% (less than 3 times), 36.4% (4~6 times) and 22.7% (more than 4 times). The conception rates relative to interval from first estrus behavior to insemination for estrus periods were 23.1% (less than 11 hours) and 55.6% (12~20 hours).

Characteristics of Growth, Yield, and Physiological Responses of Small-Sized Watermelons to Different Soil Moisture Contents Affected by Irrigation Starting Point in a Plastic Greenhouse (소형 수박 시설 재배 시 관수개시점에 따른 토양수분 함량별 생육, 수량 및 생리적 반응 특성 구명)

  • Huh, Yoon-Sun;Kim, Eun-Jeong;Noh, Sol-Ji;Jeon, Yu-Min;Park, Sung-Won;Yun, Geon-Sig;Kim, Tae-Il;Kim, Young-Ho
    • Journal of Bio-Environment Control
    • /
    • v.29 no.4
    • /
    • pp.388-398
    • /
    • 2020
  • Watermelon yield mainly depends on soil water content controlled by irrigation in a plastic greenhouse. In this study, we investigated the effect of different soil moisture contents affected by irrigation starting point on growth, yield, and physiological responses of small-sized watermelons. Irrigation was initiated at 5 different levels of soil water content as a starting point with soil moisture detecting sensor after 14 days of transplanting, and stopped at 7 ~ 10 days before harvest. These treatments were compared with the conventional periodic irrigation as control. When soil had the lowest moisture content (-50 kPa), the overall shoot growth was retarded, but the root length and root dry weight increased. The photosynthetic parameters (photosynthetic rate, stomatal conductance, and transpiration rate) of watermelon leaves decreased significantly in the lowest soil moisture content (-50 kPa). On the other hand, the photosynthetic rates of watermelon leaves grown with irrigation starting point between -20 and -40 kPa were observed to be higher than those of other treatments. Fruit set rate and marketable fruit yield increased significantly at -30 kPa and -40 kPa. Proline, abscisic acid (ABA), total phenol and citrulline, which are known to contribute to stress tolerance under drought condition, increased as soil water content decreased, particularly, the largest increases were recorded at -50 kPa. From these results, it was found that an appropriate water supply adjusted with an irrigation starting point between -30 and -40 kPa could help to keep favorable soil water content during the cultivation of small-sized watermelons, promoting the marketable fruit production as well as inducing the vigorous plant growth and reproductive development.

Novel Method for Urinary 1-Hydroxypyrene Measurement Using Molecular Imprinting (분자주형을 이용한 요중 1-hydroxypyrene의 측정 방법 개발)

  • Yim, Dong-Hyuk;Moon, Sun-In;Choi, Young-Sook;Park, Hee-Jin;Kim, Dae-Seon;Yu, Seung-Do;Lee, Chul-Ho;Kim, Yong-Dae;Kim, Heon
    • Journal of Life Science
    • /
    • v.21 no.4
    • /
    • pp.549-553
    • /
    • 2011
  • This study was performed to determine whether or not urinary 1-hydroxypyrene (1-OHP) levels can be accurately detected by our 1-OHP-detecting $TiO_2$-Bead-HPLC assay that we developed based on the molecular imprinting method. Our method showed a variation coefficient of 4.97% and a between-day variation coefficient of 4.43%, suggesting that this may be a very stable method. In addition, the recovery rate of 1-OHP from a mixture of 1-OHP and similar substances using our $TiO_2$-Bead-HPLC method was estimated to be 105.6%. The correlation coefficient between the conventional enzyme-HPLC method and this new method was 0.74 (p<0.01) when the urine samples were tested. Based on this result, it is conceivable that our method could be a useful technique for measuring urinary 1-OHP levels. Moreover, our method has some advantages of being easier and less expensive than the conventional method. The results of this study suggest that our method can facilitate the development of a urine 1-OHP sensor using $TiO_2$-coating beads and that development of beads by molecular imprinting can be applied to analysis of chemicals other than 1-OHP.

EFFECT OF INSTRUMENT COMPLIANCE ON THE POLYMERIZATION SHRINKAGE STRESS MEASUREMENTS OF DENTAL RESIN COMPOSITES (측정장치의 compliance 유무가 복합레진의 중합수축음력의 측정에 미치는 영향)

  • Seo, Deog-Gyu;Min, Sun-Hong;Lee, In-Bog
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.2
    • /
    • pp.145-153
    • /
    • 2009
  • The purpose of this study was to evaluate the effect of instrument compliance on the polymerization shrinkage stress measurements of dental composites. The contraction strain and stress of composites during light curing were measured by a custom made stress-strain analyzer, which consisted of a displacement sensor, a cantilever load cell and a negative feedback mechanism. The instrument can measure the polymerization stress by two modes: with compliance mode in which the instrument compliance is allowed, or without compliance mode in which the instrument compliance is not allowed. A flowable (Filtek Flow: FF) and two universal hybrid (Z100: Z1 and Z250: Z2) composites were studied. A silane treated metal rod with a diameter of 3.0 mm was fixed at free end of the load cell, and other metal rod was fixed on the base plate. Composite of 1.0 mm thickness was placed between the two rods and light cured. The axial shrinkage strain and stress of the composite were recorded for 10 minutes during polymerization. and the tensile modulus of the materials was also determined with the instrument. The statistical analysis was conducted by ANOVA. paired t-test and Tukey's test (${\alpha}<0.05$). There were significant differences between the two measurement modes and among materials. With compliance mode, the contraction stress of FF was the highest: 3.11 (0.13). followed by Z1: 2.91 (0.10) and Z2: 1.94 (0.09) MPa. When the instrument compliance is not allowed, the contraction stress of Z1 was the highest: 17.08 (0.89), followed by FF: 10.11 (0.29) and Z2: 9.46 (1.63) MPa. The tensile modulus for Z1, Z2 and FF was 2.31 (0.18), 2.05 (0.20), 1.41 (0.11) GPa, respectively. With compliance mode. the measured stress correlated with the axial shrinkage strain of composite: while without compliance the elastic modulus of materials played a significant role in the stress measurement.

Monitoring of the Sea Surface Temperature in the Saemangeum Sea Area Using the Thermal Infrared Satellite Data (열적외선 위성자료를 이용한 새만금 해역 해수표면온도 모니터렁)

  • Yoon, Suk;Ryu, Joo-Hyung;Min, Jee-Eun;Ahn, Yu-Hwan;Lee, Seok;Won, Joong-Sun
    • Korean Journal of Remote Sensing
    • /
    • v.25 no.4
    • /
    • pp.339-357
    • /
    • 2009
  • The Saemangeum Reclamation Project was launched as a national project in 1991 to reclaim a large coastal area of 401 km$^2$ by constructing a 33-km long dyke. The final dyke enclosure in April 2006 has transformed the tidal flat into lake and land. The dyke construction has abruptly changed not only the estuarine tidal system inside the dyke, but also the coastal marine environment outside the dyke. In this study, we investigated the spatial change of SST distribution using the Landsat-5/7 and NOAA data before and after the dyke completion in the Saemangeum area. Satellite-induced SST was verified by compared with the various in situ measurements such as tower, buoy, and water sample. The correlation coefficient resulted in above 0.96 and RMSE was about 1$^{\circ}C$ in all data. 38 Landsat satellite images from 1985 to 2007 were analyzed to estimate the temporal and spatial change of SST distribution from the beginning to the completion of the Samangeum dyke's construction. The seasonal change in detailed spatial distribution of SST was measured, however, the estimation of change during the Saemangeum dyke's construction was hard to figure out owing to the various environmental conditions. Monthly averaged SST induced from NOAA data from 1998 to 2007 has been analyzed for a complement of Landsat's temporal resolution. At the inside of the dyke, the change of SST from summer to winter was large due to the relatively high temperature in summer. In this study, multi-sensor thermal remote sensing is an efficient tool for monitoring the temporal and spatial distribution of SST in coastal area.

Development of the Filterable Water Sampler System for eDNA Filtering and Performance Evaluation of the System through eDNA Monitoring at Catchment Conduit Intake-Reservoir (eDNA 포집용 채수 필터시스템 개발과 집수매거 취수지 내에서의 성능평가)

  • Kwak, Tae-Soo;Kim, Won-Seok;Lee, Sun Ho;Kwak, Ihn-Sil
    • Korean Journal of Ecology and Environment
    • /
    • v.54 no.4
    • /
    • pp.272-279
    • /
    • 2021
  • A pump-type eDNA filtering system that can control voltage and hydraulic pressure respectively has been developed, and applied a filter case that can filter out without damaging the filter. The filtering performance of the developed system was evaluated by comparing the eDNA concentration with the conventional vacuum-pressured filtering method at the catchment conduit intake reservoir. The developed system was divided into a voltage control (manual pump system) method and a pressure control (automatic pump system) method, and the pressure was measured during filtering and the pressure change of each system was compared. The voltage control method started with 65 [KPa] at the beginning of the filtering, and as the filtering time elapsed, the amount of filtrate accumulated in the filter increased, so the pressure gradually increased. As a result of controlling the pressure control method to maintain a constant pressure according to the designed algorithm, there was a difference in the width of the hydraulic pressure fluctuation during the filtering process according to the feedback time of the hydraulic pressure sensor, and it was confirmed that the pressure was converged to the target pressure. The filtering performance of the developed system was confirmed by measuring the eDNA concentration and comparing the voltage control method and the hydraulic control method with the control group. The voltage control method obtained similar results to the control group, but the hydraulic control method showed lower results than the control group. It is considered that the low eDNA concentration in the hydraulic control method is due to the large pressure deviation during filtering and maintaining a constant pressure during the filtering process. Therefore, rather than maintaining a constant pressure during filtering, it was confirmed that a voltage control method in which the pressure is gradually increased as the filtrate increases with the lapse of filtering time is suitable for collecting eDNA. As a result of comparing the average concentration of eDNA in lentic zone and lotic zone as a control group, it was found to be 96.2 [ng µL-1] and 88.4 [ng µL-1l], respectively. The result of comparing the average concentration of eDNA by the pump method was also high in the lentic zone sample as 90.7 [ng µL-1] and 74.8 [ng µL-1] in the lentic zone and the lotic zone, respectively. The high eDNA concentration in the lentic zone is thought to be due to the influence of microorganisms including the remaining eDNA.

Stress Variation Characteristics of Temporary Fixed Steel Rod in FCM Bridge Construction Method (FCM 교량 가설 공법에서 임시 고정 강봉의 응력 변화 특성 )

  • Hyun-Euk Kang;Wan-Shin Park;Young-Il Jang;Sun-Woo Kim;Hyun-Do Yun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.3
    • /
    • pp.21-29
    • /
    • 2023
  • In this study, the stress characteristics of temporary fixed steel rods were analyzed in the "temporary fixing system using internal prestressing tension", which is mainly applied to the construction of superstructures by FCM. It was difficult to confirm the changes in initial tensile force in this system because the steel rod was internally connected to the pier and the PSC BOX. Therefore, measurement was performed before and after the completion of each segment using an FBG sensor to measure the change in the micro length of the steel rod. The results of the analysis showed that 75% to 90% of the maximum vertical contraction of the steel rod that occurred until the completion of the cantilever segment occurred in the fixing ~ 1segment, and the maximum loss of initial prestressing force was 39%. Such excessive loss of tension force to 1 segment means that tension is needed to improve the precision of construction during the fixation, and re-tension is needed to secure stability for conduction of cantilever segments after the completion of 1segment. In the 2 ~ last segment, the stress of the steel rod decreased gradually, and in the summer, the decrease in stress tended to partially recover due to the increase in the length of the steel rod corresponding to the increase in the vertical volume of PSC BOX. The dominant factor in the stress change in 2~ last segment in this phenomenon is judged to be the change in the length of the steel rod according to the temperature. Unlike the change in length, the relaxation was 1.2-2.7%, which was mostly offset by the opposite stress corresponding to the temperature stress. Therefore, a plan was proposed to improve the internal stress, such as adjusting the fixation time.