• Title/Summary/Keyword: sum of temperature

Search Result 225, Processing Time 0.024 seconds

Prediction of Wind Farm Noise with Atmospheric Stability (대기 안정 상태에 따른 풍력 단지 소음 전파 예측)

  • Son, Eunkuk;Lee, Seunghoon;Jeon, Minu;Lee, Soogab
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.42.2-42.2
    • /
    • 2011
  • Noise generated from wind turbines has been predicted by numerical methods. Sound pressure level(SPL) on the turbines is predicted after aerodynamic analysis is carried out by Wind Turbine Flow, Aeroacoustics and Structure analysis (WINFAS) code. The level of each panel of acoustic sphere is determined by the sum of tonal, turbulence ingestion and airfoil self noise. With the noise source database, the acoustic sphere, SPL on the ground is calculated using the model based on acoustic ray theory. The model has been designed to consider the effects on the condition of terrain and atmosphere. The variations of SPL on the ground occur not only because of the different source level but also because of the nonuniform distributions of the sound speed along the height. Hence, the profile of an effective sound speed which is the sum of the contribution of sound speed to a temperature gradient and a wind speed variation is used by the theory based on atmospheric stability. With the integrated numerical method, the prediction of sound propagation on the wind farm is carried out with the states of the atmospheric stability.

  • PDF

Implementation of Single-Phase Energy Measurement IC (단상 에너지 측정용 IC 구현)

  • Lee, Youn-Sung;Seo, Hae-Moon;Kim, Dong Ku
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.12
    • /
    • pp.2503-2510
    • /
    • 2015
  • This paper presents a single-phase energy measurement IC to measure electric power quantities. The entire IC includes two programmable gain amplifiers (PGAs), two ${\sum}{\Delta}$ modulators, a reference circuit, a low-dropout (LDO) regulator, a temperature sensor, a filter unit, a computation engine, a calibration control unit, registers, and an external interface block. The proposed energy measurement IC is fabricated with $0.18-{\mu}m$ CMOS technology and housed in a 32-pin quad-flat no-leads (QFN) package. It operates at a clock speed of 4,096 kHz and consumes 10 mW in 3.3 V supply.

An Analysis on the Climate Change Exposure of Fisheries and Fish Species in the Southern Sea under the RCP Scenarios: Focused on Sea Temperature Variation (RCP 시나리오에 따른 남해안 어업 및 어종의 기후변화 노출 분석 : 수온 변동을 대상으로)

  • Kim, Bong-Tae;Lee, Joon-Soo;Suh, Young-Sang
    • The Journal of Fisheries Business Administration
    • /
    • v.47 no.4
    • /
    • pp.31-44
    • /
    • 2016
  • The purpose of this study is to analyze the climate change exposure of fisheries and fish species in the southern sea of Korea under the RCP climate change scenarios. The extent of exposure was calculated through weighted sum of the sea temperature forecasted by National Institute of Fisheries Science, and the weight were obtained from the time-space distribution of each fisheries or species, based on the micro-data for the fishing information reported by each fisherman. Results show that all the exposed sea temperature of RCP8.5 is higher than that of RCP4.5 in year 2100 as well as in near 2030, therefore it is thought to be very important to reduce the GHG emission even in the short term. The extent of exposure was analyzed to be comparatively high especially in the fisheries such as anchovy drag nets and species like cod, anchovy and squid. Meanwhile the method of this study is considered to be excellent to obtain the accurate extent of exposure under RCP scenarios, and therefore it is applicable on assessing the vulnerability of climate change in fisheries.

A Study on Thermodynamics for Compositional Separation in Co-Cr magnetic Alloy Films (Co-Cr 자성합금 박막의 조성적 상분리 현상의 열역학적 고찰)

  • Song, O-Seong;Jeon, Jeon-An
    • Korean Journal of Materials Research
    • /
    • v.9 no.4
    • /
    • pp.341-344
    • /
    • 1999
  • We reported compositional separation(CS) into Co-enriched and Cri-enriched components inside the grains of Co-Cr based thin films prepared by rf sputtering. CS strongly depends on the sputtering conditions of substrate temperature and target composition. Tuning the microstructure of the Co-Cr films is important in order to employ the CS for high-density magnetic recording. We investigated the origin of CS from thermodynamic viewpoint. We employ a spinodal decomposition-like model to describe the origin of the CS in Co-Cr films. We consider the total free energy of the Co-Cr films as the sum of several free energies of; 1) thermodynamic mixing entropy of a binary solid solution, 2) magnetic ordering interaction(MOI) energy below the Curie temperature, and 3) excess interaction energy(XS) caused by the sputtering process as a function of temperature and composition. Those energies distorted the total free energy like the spinodal decomposition and caused the compositionally separated fine microstructure inside the grains. If the second derivative of the total free energy with respect to Cr composition becomes negative at a given substrate temperature, we may observe a metastable compositional separation inside the Co-Cr alloy films. We expect to exploit the microstructure of CS for ultra-high density magnetic recording.

  • PDF

The Effect of Winter Temperature on the Survival of Lantern Fly, Lycorma delicatula (Hemiptera: Fulgoridae) Eggs (동절기 온도가 꽃매미 월동 알의 생존율에 미치는 영향)

  • Lee, Young Su;Jang, Myoung Jun;Kim, Jin Young;Kim, Jun Ran
    • Korean journal of applied entomology
    • /
    • v.53 no.3
    • /
    • pp.311-315
    • /
    • 2014
  • Lantern fly(Lycorma delicatula) is a major invasive pest that causes withering symptom of agricultural crops by sucking tree sap and sooty mold symptom by producing honeydew. This study was conducted to investigate the occurrence pattern of lantern fly in grape orchards in Gyeonggi area and the effect of winter temperature on L. delicatula egg survival during 2010 to 2013. In Gyeonggi areas, overwintered L. delicatula eggs began to hatch from early May and nymphs peaked in mid May. Adults emerged from late July and laid eggs until early November. The survival of L. delicatula eggs during overwintering was largely affected by winter temperatures. The relationship between the number of days below a threshold temperature (x) in January and the survival rate of overwintering L. delicatula eggs (y) was using linear regression model. The best model selected by the lowest RSS (residual sum of square) between predicted and actual survival was y = -1.0486 x + 94.496 ($R^2=0.7067$) with $-11^{\circ}C$ of threshold temperature. These results should be helpful to conduct L. delicatula management programs, since the results provided relivable prediction for the winter survival of L. delicatula eggs and the phenology of egg hatch in the spring.

An Analysis of the Optimal Thermal Storage Time of Air-Conditioning System with Slab Thermal Storage : An Analysis by the Gradient Method Algorithm (슬래브축열의 최적축열시간 산정 : 구배법 알고리즘에 의한 해석)

  • Jung, Jae-Hoon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.10
    • /
    • pp.702-709
    • /
    • 2008
  • In this paper, the optimal thermal storage time of an air-conditioning system with slab thermal storage in office building was analyzed on the basis of the gradient method algorithm. The sum of room temperature deviation and heat extraction rate was set to the criterion function. It was calculated that four hours is the optimal thermal storage time under the standard evaluation criterion. Furthermore, some case studies were executed by controlling ratio of weight functions of room temperature deviation and heat extraction rate in criterion function. It is possible to design many kinds of optimal operation of an air-conditioning system with slab thermal storage by controlling ratio of the weight functions in criterion function.

New Approach to Investigate the Dynamic Relaxaton Process of Complex Peak in Mechanical and dielectric Characteristics of Anelastic Solids

  • Kim, Bong-Heup
    • Electrical & Electronic Materials
    • /
    • v.11 no.10
    • /
    • pp.1-5
    • /
    • 1998
  • Complex dynamic relaxation processes of mechanical as well as dielectric character in polymeric anelastic solids are closely related through the movement of molecular chain segment in morphological structure, and the morphology can easily be modified by the treatments such as mechanical drawing or irradiation, those of which result, in turn, the complicated change on the appearance of the observed complex relaxation peak. In order to extract any meaningful understanding from the modified appearance of the peak, the relaxation peak must be resolved into the sum of the dynamic single relaxation peaks, each of which can be characterized respectively by three factors such as activation energy, magnitude of peak height and peak point temperature on the temperature dependent characteristics.

  • PDF

Fuzzy inference based cover thickness estimation of reinforced concrete structure quantitatively considering salty environment impact

  • Do, Jeong-Yun
    • Computers and Concrete
    • /
    • v.3 no.2_3
    • /
    • pp.145-161
    • /
    • 2006
  • This article involves architecting prototype-fuzzy expert system for designing the nominal cover thickness by means of fuzzy inference for quantitatively representing the environment affecting factor to reinforced concrete in chloride-induced corrosion environment. In this work, nominal cover thickness to reinforcement in concrete was determined by the sum of minimum cover thickness and tolerance to that defined from skill level, constructability and the significance of member. Several variables defining the quality of concrete and environment affecting factor (EAF) including relative humidity, temperature, cyclic wet and dry, and the distance from coast were treated as fuzzy variables. To qualify EAF the environment conditions of cycle degree of wet-dry, relative humidity, distance from coast and temperature were used as input variables. To determine the nominal cover thickness a qualified EAF, concrete grade, and watercement ratio were used. The membership functions of each fuzzy variable were generated from the engineering knowledge and intuition based on some references as well as some international codes of practice.

Enhanced performance at an early state of hydrocarbon selective catalyst reduction of NOx by atmospheric pressure plasma

  • Nguyen, Duc Ba;Heo, Il Jeong;Mok, Young Sun
    • Journal of Industrial and Engineering Chemistry
    • /
    • v.68
    • /
    • pp.372-379
    • /
    • 2018
  • The improvement of $NO_x$ reduction by $Ag/{\gamma}-Al_2O_3$ with a hydrocarbon ($n-C_7H_6$) in the early state was investigated in a packed-bed dielectric barrier discharge plasma reactor. The results revealed that the combination of plasma with the catalyst enhanced $NO_x$ reduction efficiency at low operating temperatures, depending on the temperature and specific input energy. To sum up, the poor performance of the catalytic $NO_x$ reduction at low temperatures in the early stage before reaching thermochemical steady state can be greatly compensated for by using the atmospheric-pressure plasma generated in the catalyst bed.

Compressor Control of a Multi-type AIr Conditioning System (멀티형 냉방시스템의 압축기 제어)

  • 한도영;권형진
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.8
    • /
    • pp.780-786
    • /
    • 2001
  • For the compressor speed control of a multi-type air conditioning system, a fuzzy control algorithm was developed. The sum of zone temperature errors and its derivative were used as input variables, and the compressor speed was selected as the output variable. To test the effectiveness of the control algorithm, one outdoor environmental chamber and four indoor environmental chambers were used. In the chambers the zone temperature step change test and the indoor unit change over test were performed. Test results showed that, for the control of compressor speed, the fuzzy control algorithm was more effective than the conventional proportional control algorithm for the energy conservation.

  • PDF