• Title/Summary/Keyword: suction detection

Search Result 22, Processing Time 0.026 seconds

Estimation of Probability Density Functions of Damage Parameter for Valve Leakage Detection in Reciprocating Pump Used in Nuclear Power Plants

  • Lee, Jong Kyeom;Kim, Tae Yun;Kim, Hyun Su;Chai, Jang-Bom;Lee, Jin Woo
    • Nuclear Engineering and Technology
    • /
    • v.48 no.5
    • /
    • pp.1280-1290
    • /
    • 2016
  • This paper presents an advanced estimation method for obtaining the probability density functions of a damage parameter for valve leakage detection in a reciprocating pump. The estimation method is based on a comparison of model data which are simulated by using a mathematical model, and experimental data which are measured on the inside and outside of the reciprocating pump in operation. The mathematical model, which is simplified and extended on the basis of previous models, describes not only the normal state of the pump, but also its abnormal state caused by valve leakage. The pressure in the cylinder is expressed as a function of the crankshaft angle, and an additional volume flow rate due to the valve leakage is quantified by a damage parameter in the mathematical model. The change in the cylinder pressure profiles due to the suction valve leakage is noticeable in the compression and expansion modes of the pump. The damage parameter value over 300 cycles is calculated in two ways, considering advance or delay in the opening and closing angles of the discharge valves. The probability density functions of the damage parameter are compared for diagnosis and prognosis on the basis of the probabilistic features of valve leakage.

Sipping Test Technology for Leak Detection of Fission Products from Spent Nuclear Fuel (사용후핵연료 핵분열생성물 누출탐상 Sipping 검사기술)

  • Shin, Jung Cheol;Yang, Jong Dae;Sung, Un Hak;Ryu, Sung Woo;Park, Young Woo
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.16 no.2
    • /
    • pp.18-24
    • /
    • 2020
  • When a damage occurs in the nuclear fuel burning in the reactor, fission products that should be in the nuclear fuel rod are released into the reactor coolant. In this case, sipping test, a series of non-destructive inspection methods, are used to find leakage in nuclear fuel assemblies during the power plant overhaul period. In addition, the sipping test is also used to check the integrity of the spent fuel for moving to an intermediate dry storage, which is carried out as the first step of nuclear decommissioning, . In this paper, the principle and characteristics of the sipping test are described. The structure of the sipping inspection equipment is largely divided into a suction device that collects fissile material emitted from a damaged assembly and an analysis device that analyzes their nuclides. In order to make good use of the sipping technology, the radioactive level behavior of the primary system coolant and major damage mechanisms in the event of nuclear fuel damage are also introduced. This will be a reference for selecting an appropriate sipping method when dismantling a nuclear power plant in the future.

A Study on Machine Learning Algorithm Suitable for Automatic Crack Detection in Wall-Climbing Robot (벽면 이동로봇의 자동 균열검출에 적합한 기계학습 알고리즘에 관한 연구)

  • Park, Jae-Min;Kim, Hyun-Seop;Shin, Dong-Ho;Park, Myeong-Suk;Kim, Sang-Hoon
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.8 no.11
    • /
    • pp.449-456
    • /
    • 2019
  • This paper is a study on the construction of a wall-climbing mobile robot using vacuum suction and wheel-type movement, and a comparison of the performance of an automatic wall crack detection algorithm based on machine learning that is suitable for such an embedded environment. In the embedded system environment, we compared performance by applying recently developed learning methods such as YOLO for object learning, and compared performance with existing edge detection algorithms. Finally, in this study, we selected the optimal machine learning method suitable for the embedded environment and good for extracting the crack features, and compared performance with the existing methods and presented its superiority. In addition, intelligent problem - solving function that transmits the image and location information of the detected crack to the manager device is constructed.

Automatic Control System on Cardiac Output Regulation for the Moving Actuator Type Total Artificial Heart (MOVING-ACTUATOR TYPE 인공심장의 심박출 조절에 대한 자동 제어방법)

  • 김원곤
    • Journal of Chest Surgery
    • /
    • v.28 no.6
    • /
    • pp.542-548
    • /
    • 1995
  • The goal of this study is to develop an effective control system for cardiac output regulation based upon the preload and afterload conditions without any transducers and compliance chambers in the moving actuator type total artificial heart. Motor current waveforms during the actuator movement are used as an input to the automatic control algorithm. While the current waveform analysis is performed, the stroke length and velocity of the actuator are gradually increased up to the maximum pump output level. If the diastolic filling rate of either right or left pump begins to exceed the venous return, atrial collapse will occur. Since the diastolic suction acts as a load to the motor, this critical condition can be detected by analyzing the motor current waveforms. Every time this detection criterion is met, the control algorithm decreases the stroke velocity and length of the actuator step by step just below the critical detection level. Then, they start to increase. In this way the maximum pump output under given venous return can be achieved. Additionally the control algorithm provides some degree of afterload sensitivity. If the aortic pressure is detected to exceed 120 mmHg, the stroke length and velocity decrease in the same way as the response to the preload. Left-right pump output balance is maintained by proper adjustment of the asymmetry of the stroke angle. In the mock circulatory test, this control system worked well and there was a considerable range of stroke volume difference with adjustment of the asymmetry value. Two ovine experiments were performed. It was confirmed that the required cardiac output regulation according to the venous return could be achieved with adequate detection of diastolic function, at least in the in vivo short-term survival cases[2-3 days . We conclude that this control algorithm is a promising method to regulate cardiac output in the moving actuator type total artificial heart.

  • PDF

Primary Esophageal Repair of Long-gap Esophageal Atresia - Report of One Case - (원간격결손 식도폐쇄증의 일차적 식도복원)

  • Lee, Myung-Duk
    • Advances in pediatric surgery
    • /
    • v.1 no.1
    • /
    • pp.53-58
    • /
    • 1995
  • A delayed primary esophago-esophagostomy of a case of long-gap esophageal atresia without tracheoesophageal fistula was performed in success with three months' intermittent periodic bougienage of the upper pouch via mouth as well as the lower esophagus through Janeway gastrostomy. Meanwhile, an effective continuous sump suction from the upper pouch seemed to be a critical part of the patient management. The extra length of esophagus for primary anastomosis could be achieved by a circular myotomy. Stricture at the myotomy site, found 4 months later, was treated with periodic pneumatic baloon dilations only with temporary symptomatic reliefs. After 4 months' trials, operative esophagoplasty was performed successfully. A careful follow-up schedule for the myotomy site would be required for early detection of stricture. The previous neonatal patient is currently 8 years old, healthy school-boy, and has a normal barium swallow without stricture or gastroesophageal reflux.

  • PDF

Conceptual Design of Mechanical System for Recovery of Seabed-Deposited Hazardous and Noxious Substances Based on Performance Requirements (해저침적 HNS 회수용 기계장치의 성능요건 기반 개념설계)

  • Hwang, Ho-Jin
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.26 no.6
    • /
    • pp.689-697
    • /
    • 2020
  • Hazardous and noxious substances (HNS) may cause maritime incidents during marine transportation, which are liable to lead to a large amount of spillage or discharge into the sea. The damage to the marine environment caused by the HNS spill or discharge is known to be much greater than the damage caused by oil spill. Particularly dangerous is HNS, which is deposited or buried in the seabed, as it can damage the organisms that live on, in, and near the bottom of the sea, the so-called "benthos," forming the benthic ecosystem. Therefore, it is vital that the HNS deposited on the seabed be recovered. In order to do so, procedures and equipment are required for accurate detection, stabilization treatment, and recovery of HNS in subsea sediment. Thus, when developing a mechanical recovery system, the performance requirements should be selected using performance indices, and the conceptual design of the mechanical recovery system should be based on performance requirements decided upon and selected in advance. Therefore, this study was conducted to arrive at a conceptual design for a mechanical recovery system for the recovery of HNS deposited on the seabed. In the design of the system, based on the fundamental scenario, the method of suction foundation with the function of self enclosing was adopted for recovering the HNS sediment in the subsea sediment. The mechanical recovery system comprises the suction foundation, pollution prevention, a pump system, control system, monitoring device, location information device, transfer device, and tanks. This conceptual design is expected to be reflected and used in the basic design of the components and shapes of the mechanical recovery system.

Clinical Significance of Thoracoscopy on Spontaneous Pneumothorax (자연기흉에 대한 Thoracoscopy 의 임상적의의)

  • Kim, Young-Toe;Kim, Kun-Ho
    • Journal of Chest Surgery
    • /
    • v.8 no.1
    • /
    • pp.19-28
    • /
    • 1975
  • The thoracoscopic study was reported on 21 cases of spontaneous pneumothorax requiring surgical management, and clinical values of thoracoscopic examination on spontaneous pneumothorax were also discussed. patients were treated in the Department of .Thoracic Surgery, Hanyang University Hospital for the period of two Years from May 1972 to April 1974. For exact detection of etiologic factors on spontaneous pneumothorax, the thoracoscopic examination in the intrapleural space was performed in parallel with X-ray study. this study, the difference of diagnostic and therapeutic significance between radiological and thoracoscopic findings were observed and compared simultaneously. The results are summerized as follows: Patients age was distributed between 3 and 70 years old with highest incidence in the age group of sixty decade [33. 3%], and sex ratio of male to female was 5:2. The tuberculous processes which developed superficial subpleural layer in the lung parenchyme, on the pulmonary surface could be observed by thoracoscopic examination in a characteristic picture. detection ratio of pulmonary tuberculosis by the radiologic study to that by thoracoscopy was 8:2. The adhesion between the visceral and the parietal pleura which could possibly make a rupture of the alveola and the visceral pleura was found to be localized in a small area of the lung surface. The other part of the lung surface was free of the adhesion and, therefore, the movement of the lung took place completely without any difficulty. The ruptured orifice of the pleura and pathological changes surrounding the orifice can be detected by thoracoscopy, but not by other means such as radiologic examination. A single tuberculous bleb and multiple emphysematous blebs were found on 6 cases out of 21 cases of spontaneous pneumothorax. Among these cases, radiologic Study revealed the bleb only in one patient. On the other hand, the blebs were found in all the six patients by means of thoracoscopic examination. It gives the detection ratio of bleb by radiologic study to that by thoracoscopy was 1:6. By thoracoscopy, the rupture on the lung surface were visualized on the 10 patients out of a total of 21 patients [10 patients of visual rupture]. However, the rupture of the pleura was not observed on the rest of 11 patients even by thoracoscopic examination [11 patients of non visual rupture]. Five patients [50%] out of ten who had the visual rupture on the lung surface was required a surgical operation to remove pneumothorax. For the patients who were detected to have the visual rupture of the pleura by thoracoscopy, be considered in the early stage of closed thoracostomy. of 21 patients, 16 patients [11 patients of non visual rupture of the pleura and 5 patients of visual rupture of the pleura] who received no surgical management, were treated with closed thoracostomy with continuous suction, and the` pneumothorax was healed completely up in each cases. Therapeutic measures for the remaining 5 patients of visual rupture of the pleura who were subjected to surgical approach for radical treatment of spontaneous pneumothorax were accordingly complicated, and the following different procedures were properly indicated case by case, that is, rib resection thoracostomy, simple closure of ruptured visceral pleura, wedged resection of the lung, and lobectomy.

  • PDF

A Study on Health Check Solution using Indoor Air Purifier (실내 내장형 공기순환기를 이용한 헬스 체크 솔루션에 관한 연구)

  • Yang, Hee-Tak;Oh, Ji-Su;Lee, Keun-Ho
    • Journal of Internet of Things and Convergence
    • /
    • v.3 no.1
    • /
    • pp.25-31
    • /
    • 2017
  • In the future a future type new city and the latest apartment will be built, and the IoT technology will be constructed and combined in large numbers indoors of ordinary households. An air cleaner that makes people in it comfortable is built in, and the suction port that sucks in the air of the air purifier and the discharge port that discharges it are set up around the room and come out. However, this is impossible to adjust because there is only a central switch on / off. Also, consuming a lot of electricity so that many electricity charges are caused by huge electricity consumption will eventually be a waste of resources. This would like to be adjusted and driven through the fine dust detection device to the room built-in air purifier and that has provided a solution to save electricity. In addition, since it exists in and around the room, you can grasp the position of the person and connect to the home network to enhance the convenience. Also, through analysis of the air, we provide a health-check solution that checks the user's health and adjusts it appropriately.

Effect of Groove Shape of Blade Tip on Tip Surface Heat Transfer Coefficient Distributions of a Turbine Cascade (블레이드 팁의 Groove 형상이 터빈 캐스케이드 팁 열전달 계수분포에 미치는 영향에 대한 실험적 연구)

  • Nho, Young-Cheol;Jo, Yong-Hwa;Lee, Yong-Jin;Kim, Hark-Bong;Kwak, Jae-Su
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.14 no.6
    • /
    • pp.60-68
    • /
    • 2010
  • In this study, the conventional plane tip, double squealer tip, and various groove tip blades were tested in a linear cascade in order to measure the effect of the tip shapes on tip surface heat transfer coefficient distributions. Detailed heat transfer coefficient distributions were measured using a hue-detection based transient liquid crystals technique. Two tip gap clearances of 1.5% and 2.3% of blade span were investigated and the Reynolds number based on cascade exit velocity and chord length was $2.48{\times}10^5$. Results showed that the overall heat transfer coefficients on the tip surface with various grooved tips were lower than those with plane tip blade. The overall heat transfer coefficient on grooved along suction side tip was lower than that on the squealer tip.

Saving Effects Cost and Time in Nursing through Improving Sterilization Method of Inner Cannula (기관내관 소독 방법 개선에 따른 간호업무 시간단축 및 비용 절감 효과)

  • Yi, Haeng-Seon;Kim, Haerina;Kim, Eun-Suk;Kim, Bo-Ram;Seong, Seon-Suk
    • Quality Improvement in Health Care
    • /
    • v.14 no.1
    • /
    • pp.55-59
    • /
    • 2008
  • Background : The purpose of inner cannula is to protect the upper air way and permit air to pass freely, in addition, to provide endotracheal suction, artificial respiration and to maintain adequate oxygen saturation. The tube needs to be sterilized for maintenance and cleanness of air way and for prevention of bronchospasm. However, it has been reported that there is no guideline for sterilization and many hospitals conduct their own sterilization methods, for example, once a day(13's general hospital), three times a day(The Catholic University of Korea ST Mary's hospital) or even no cleansing. Consequently, the QI team of our hospital suggested the SOP(standard operating procedure) of sterilization and evaluate cost and time effect in nursing. Method : 1) Benchmarking of 13's neurosurgery department of general hospital in Seoul 2) Investigation of test records of sputum culture from patients with intubation for tracheotomy 3) Check of results of O2 Sat. monitoring to confirm of maintaining opened air way Result : 1) Improvement of process: decrease of excess sterilization of inner cannula (from 3 times a day to once a day) 2) Cost effects: saving over 10 million won per one year 3) Providing better nursing: time effects (30 min a day) permit to conduct more nursing activities Conclusion : It can get Cost and time effects in nursing with improved sterilization method of inner cannula. It needs to do research on improvement of the monthly exchange protocol of outer cannula and provide supporting data for the proper exchange schedule. The result of additional microorganism detection from patients with new process needs to be evaluated further more.

  • PDF