• Title/Summary/Keyword: subway system

Search Result 859, Processing Time 0.029 seconds

Dependability Management System's Application to Subway Corporation (도시철도운영기관의 종합신뢰성 경영시스템 적용방안 연구)

  • Ha Chen-Soo;Hong Soon-Ki;Lee Ho-Yong;Han Seok-Youn
    • Journal of the Korean Society for Railway
    • /
    • v.8 no.3
    • /
    • pp.286-292
    • /
    • 2005
  • In this paper, we introduce IEC 60300(Dependability program management) into urban transit system, and propose effective method to apply IEC 60300 to Subway Corporation. The dependability is the collective term used to describe the availability performance and its influencing factors such as reliability performance, maintainability performance and maintenance support performance. A dependability program covers all phases of a system's life cycle from planning to operation and possibly disposal, and is composed of program elements divided into tasks.

Fault Restoration Algorithm for Subway Power System (지하철 전력계통에서의 사고복구 시스템 알고리즘 개발)

  • Kim, J.U.;Ryu, H.S.;Lee, J.G.;Moon, Y.H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.308-310
    • /
    • 2001
  • This paper is to introduce a more effective and flexible restoration algorithm composed to the fault preventing and restoring system now in use. This was possible by considering the changes that can occur by the proper or the improper run of the Feeder, which the power system restoration method now using didn't consider. The new algorithm uses the method minimizing the loss with respect to the load changes occuring when the power system is restored, rather than just simply following the SOP that is only composed of a single Feeder On/off combination. This can present the more effective power system running method for the safer subway running and passenger transport, by giving the system operator the chance to choose between the SOP and the minimum loss method.

  • PDF

The Construction of Driverless Signaling System based on Communication for the Maglev Control (자기부상열차 제어를 위한 통신기반 무인 신호시스템 구축)

  • Kang, Deok-Won;Lee, Jong-Seong;Kim, Kyoung-Shik;Min, Young-Ki
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.519-534
    • /
    • 2008
  • The Maglev travels at levitated status from the rail in some gab (about $8\sim10mm$). it make difference with the existing subway or the another LRV. The detection method of the train speed and the train position to be used at Maglev's signaling system differ with the existing subway or the another LRV's. so, the signal system construction of the new method is necessary. This paper describes the configuration and characteristic of the total signaling system (TTC/Wayside/Cab/Guide way system etc.) developed for Maglev, and the design concept of the signaling system based on the latest wireless LAN communication for driverless operation.

  • PDF

A Case study of the automatic operation due to the Train to the Wayside to TWC communication(Focused on the Subway ATO/TWC equipment) (열차와 지상간 TWC 통신에 의한 자동운전에 관한 연구(지하철 ATO/TWC 설비를 중심으로))

  • Hwang, In-Kil;Song, Joong-Ho
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.900-905
    • /
    • 2006
  • 5678SMRT (Seoul Metropolitan Rapid Transit Co) by a ATC/ATO system the other side which is operated with an automatic movement with a manual operation, the Seoul subway 1.2 lines ATS and 3.4 lines adopt a ATC method and they are operated. But it is improving progressively in SMRT railway ATO method. The ATO the operation method leads exchange of information of wayside and train system for and it is possible, the TWC system configuration is becoming wayside and train system and the radio antenna. It discussed the equipment for a TWC system and a automatic operation from the dissertation which it sees. It investigated a data exchange, a message format and an interface control method and it joined in and a system maintenance conservative method it discussed.

  • PDF

Investigation of Wireless Communication Technology for the WSN of Subway Station (도시철도 역사 WSN 구현을 위한 무선통신 기술 분석)

  • Kim, Gab-Young;Jeon, Bo-Ik;Ahn, Tae-Ki;Shin, Jeong-Ryol
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.1344-1353
    • /
    • 2008
  • The trend is that the wireless communication system, which has specific characteristics ; low cost & limitation for installation, has been developed more actively than the wire communication system. Therefore, the communication system has been changed from the wire system with an optical cable to the wireless system in the various field of life. In the railroad field, lots of researches on the wireless communication system for the safety of infrastructure and the convenience of passenger have been conducted. The WSN(Wireless Sensor Network), which means same concept with USN(Ubiquitous Sensor Network), pursues the ubiquitous environment which means user can access network at anywhere and anytime. In this paper, the wireless communication technologies which are suitable for the WSN of subway station were investigated and the best solution of WSN was suggested.

  • PDF

Evacuation safety analysis depending on the type of subway platform and ticket barrier (지하철 승강장과 개찰구 유형별 대피안전성 분석)

  • Park, Byoung-Jik;Park, Il-Gyu;Yoo, Yong-Ho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.17 no.3
    • /
    • pp.237-242
    • /
    • 2015
  • With the rapid development of modern society, subway has become one of the most typical urban transport systems. Since fire accident occurred at Daegu subway in 2003, importance of life safety and disaster prevention have been widely recognized and many studies have been carried out. As a result of these studies, fire-retardant and non-combustible interior material and platform screen door with passenger guide indication device have been developed, but studies on a subway evacuation criteria have been in a stalemate. Therefore, this study is intended to improve the subway evacuation standard. It is very difficult to take into account whole subway system, so a typological approach to a ticket was carried out referring to previous studies focused on a subway platform. this paper selected the most common subway platforms and estimated evacuation time among 10 platforms from previous studies and 8 from this study. As a result, evacuation time exceeded 6 minutes which is the guideline of existing standard. Therefore, it is necessary to update the standard for evacuation time and add supplementary conditions which can help establishing the measures for safety facilities and prevention measures.

Characterization of Summertime Aerosol Particles Collected at Subway Stations in Seoul, Korea Using Low-Z Particle Electron Probe X-ray Microanalysis

  • Kim, Bo-Wha;Jung, Hae-Jin;Song, Young-Chul;Lee, Mi-Jung;Kim, Hye-Kyeong;Kim, Jo-Chun;Sohn, Jong-Ryeul;Ro, Chul-Un
    • Asian Journal of Atmospheric Environment
    • /
    • v.4 no.2
    • /
    • pp.97-105
    • /
    • 2010
  • A quantitative single particle analytical technique, denoted low-Z particle electron probe X-ray microanalysis (low-Z particle EPMA), was applied to characterize particulate matters collected at two underground subway stations, Jegidong and Yangje stations, in Seoul, Korea. To clearly identify the source of the indoor aerosols in the subway stations, four sets of samples were collected at four different locations within the subway stations: in the tunnel; at the platform; near the ticket office; nearby outdoors. Aerosol samples collected on stages 2 and 3 ($D_p$: $10-2.5\;{\mu}m$ and $2.5-1.0\;{\mu}m$, respectively) in a 3-stage Dekati $PM_{10}$ impactor were investigated. Samples were collected during summertime in 2009. The major chemical species observed in the subway particle samples were Fe-containing, carbonaceous, and soil-derived particles, and secondary aerosols such as nitrates and sulfates. Among them, Fe-containing particles were the most popular. The tunnel samples contained 85-88% of Fe-containing particles, with the abundance of Fe-containing particles decreasing as the distances of sampling locations from the tunnel increased. The Fe-containing subway particles were generated mainly from mechanical wear and friction processes at rail-wheel-brake interfaces. Carbonaceous, soil-derived, and secondary nitrate and/or sulfate particles observed in the underground subway particles likely flowed in from the outdoor environment by human activities and the air-exchange between the subway system and the outdoors. In addition, since the platform screen doors (PSDs) limit air-mixing between the tunnel and the platform, samples collected at the platform at the Yangjae station (with PSDs) showed a marked decrease in the relative abundances of Fe-containing particles compared to the Jegidong station (without PSDs).

Measurement of 18GHz Radio Propagation Characteristics in Subway Tunnel for Train-Wayside Multimedia Transmission (지하철 터널에서의 18GHz 무선영상신호 전파특성 측정)

  • Choi, Kyu-Hyoung;Seo, Myung-Sik
    • Journal of the Korean Society for Railway
    • /
    • v.15 no.4
    • /
    • pp.364-369
    • /
    • 2012
  • This paper presents an experimental study on the radio propagation characteristics in subway tunnel at 18GHz frequency band which has been assigned to video transmission between train and wayside. The radio propagation tests are carried out in the subway tunnel of Seoul Metro using the antenna and communication devices of the prototype video transmission system. The measurement results show that 18GHz radio propagation in subway tunnel has smaller path loss than that of general outdoor radio environment. It is also cleared that the arch-type tunnels have smaller radio propagation losses than rectangular tunnels, and single track tunnels have smaller pass loss than double track tunnels. From the measurements, the radio propagation coverage is worked out as 520 meters. The curved tunnels which cannot have LOS communication between transmitter and receiver have large pass losses and fluctuation profile along distance. The radio propagation coverage along curved tunnels is worked out as 300 meters. These investigation results can be used to design the 18GHz radio transmission system for subway tunnel by providing the optimized wayside transmitter locations and handover algorithm customized to the radio propagation characteristics in subway tunnels.

Characterizing Par ticle Matter on the Main Section of the Seoul Subway Line-2 and Developing Fine Particle Pollution Map (서울시 지하철 2호선 본선구간의 입자상물질 농도 특성 및 미세분진의 오염지도 개발)

  • Lee, Eun-Sun;Park, Min-Bin;Lee, Tae-Jung;Kim, Shin-Do;Park, Duck-Shin;Kim, Dong-Sool
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.32 no.2
    • /
    • pp.216-232
    • /
    • 2016
  • In present, the Seoul City is undergoing traffic congestion problems caused by rapid urbanization and population growth. Thus the City government has reorganized the mass transportation system since 2004 and the subway has become a very important means for public transit. Since the subway system is typically a closed environment, the indoor air quality issues have often raised by the public. Especially since a huge amount of PM (particulate matter) is emitted from ground tunnels passing through the subway train, it is now necessary to assess the characteristics and behaviors of fine PM inside the tunnel. In this study, the concentration patterns of $PM_1$, $PM_{2.5}$, and $PM_{10}$ in the Seoul subway line-2 were analyzed by real-time measurement during winter (Jan 13, 2015) and summer (Aug 7, 2015). The line-2 consisting of 51 stations is the most busy circular line in Seoul having the railway of 60.2 km length. The the one-day average $PM_{10}$ concentrations were $148{\mu}g/m^3$ in winter and $66.3{\mu}g/m^3$ in summer and $PM_{2.5}$ concentrations were $118{\mu}g/m^3$ and $58.5{\mu}g/m^3$, respectively. The $PM_{2.5}/PM_{10}$ ratio in the underground tunnel was lower than the outdoor ratio and also the ratio in summer is higher than in winter. Further the study examined structural types of underground subsections to explain the patterns of elevated PM concentrations in the line-2. The subsections showing high PM concentration have longer track, shorter curvature radius, and farther from the outdoor stations. We also estimated the outdoor PM concentrations near each station by a spatial statistical analysis using the $PM_{10}$ data obtained from the 40 Seoul Monitoring Sites, and further we calculated $PM_{2.5}/PM_{10}$ and $PM_1/PM_{10}$ mass ratios near the outdoor subway stations by using our observed outdoor $PM_1$, $PM_{2.5}$, and $PM_{10}$ data. Finally, we could develop pollution maps for outdoor $PM_1$ and $PM_{2.5}$ near the line-2 by using the kriging method in spatial analysis. This methodology may help to utilize existing $PM_{10}$ database when managing and control fine particle problems in Korea.

Environmental Sensor Monitoring System of Subway Stations Using USN (USN을 이용한 지하철 역사 대기환경 모니터링 시스템)

  • Oh, Joon-Tae;Kim, Gyu-Sik
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.48 no.3
    • /
    • pp.60-66
    • /
    • 2011
  • The$PM_{10}$ concentrations in the underground should be monitored for the health of commuters on the subway system. Seoul Metro and Seoul Metropolitan Rapid Transit Corporation are measuring several air pollutants regularly. In this paper, the reliability of the instruments using light scattering method is improved with the help of a linear regression analysis technique to measure the $PM_{10}$ concentrations continuously in the subway stations. In addition, an USN monitoring system is implemented to display and record the data of $PM_{10}$, CO/$CO_2$, humidity, and temperature. To transmit and receive these measured sensor data, 2.4GHz Zigbee, 424MHz wireless communication, and CDMA M2M method are applied and evaluated.