• Title/Summary/Keyword: subsidiary

Search Result 596, Processing Time 0.044 seconds

Automatic Data Matching System for CAD Data's Integrity (CAD 데이터의 무결성을 위한 데이터 매칭 자동화 시스템)

  • Byeon, Hae-Gwon;Yoo, Woo-Sik
    • IE interfaces
    • /
    • v.24 no.1
    • /
    • pp.71-77
    • /
    • 2011
  • Design works consist of essential works and subsidiary works. Essential design works means designing creative ideas and productive ideas, while subsidiary design works means helping essential works those are making data tables and specification sheets, checking CAD data's integrity. Subsidiary design works forms the bulk of the whole design process and affects the time limit of delivery. Therefore we propose the automatic data matching system for CAD data's integrity. Proposed system is automatic system supporting subsidiary design works. The data matching system consists of three parts; 1) automatic generation of data tables 2) supporting module for checking CAD data's integrity between Drawings 3) automatic generation of spec. sheets. Developed system was tested in LCD equipment manufacture company and was found to be useful system.

A Study on Layout Characteristics of Subsidiary Welfare Facilities at Apartment Complexes in New Towns - Focused on Apartment Complexes in Second Phase New Towns - (신도시 공동주택 부대복리시설의 배치특성에 관한 연구 - 제 2기 신도시 아파트를 중심으로 -)

  • Moon, Ja-Young;Jung, Yu-Ri;Hwang, Yeon-Sook
    • Korean Institute of Interior Design Journal
    • /
    • v.26 no.3
    • /
    • pp.81-90
    • /
    • 2017
  • Subsidiary welfare facilities in an apartment complex are one of the most important factors for consumers when they buy an apartment due to an increase of consumers' consciousness level, increase of leisure time, and increase of cultural life. This study aims to analyze layout types and characteristics of subsidiary welfare facilities at the apartment complexes in the second phase new towns, investigate the current situation and find out the improvement direction. For this purpose, this author investigated three "second phase new towns" which were designated as a new town at similar time, and selected a total of 15 apartment complexes by selecting 5 complexes in each of the three new towns. Literature survey, case visit, photo shoot, user observation survey were used as study methods. The results of the study are as follows. First, it was found that a mixed type was the most common type of plane layout types in the subsidiary welfare facilities. This type improves accessibility and equity of the residents as the facilities are appropriately placed based on the functions and the user characteristics. Second, it can be considered that a distributed type for senior citizen centers and daycare centers may give independence to specific users, but it may give a sense of alienation to the elderly. Moreover, it does not have enough community so that it is necessary to make proper supplementation. Third, there were two lay out types. The first one is that the subsidiary welfare facilities are placed with step difference and the second one is that they are placed in sunken places using the underground space. Fourth, all layout types of outdoor facilities are distributed types, and it is considered that measurements for a proper balance of accessibility and equity are required.

A Study on the Revision Efficiency of Referenced Specifications/Standards for Raw and Subsidiary Materials in the Field of National Defense (국방분야 인용 원·부자재 규격/표준 개정 효율화 연구)

  • Park, KC;Baek, HM;Kim, TW;Gil, HJ;Kwon, JS;Lee, IL;Song, SB;Won, SH
    • Journal of Korean Society for Quality Management
    • /
    • v.46 no.3
    • /
    • pp.497-508
    • /
    • 2018
  • Purpose: The purpose of this study is to research the revision efficiency of the referenced specifications/standards for raw and subsidiary materials in the field of national defense. Methods: Firstly, it was carried out to investigate the all of the Korean military drawings and establish the database for specifications/standards referenced in the field of national defense. Secondly, it was reviewed the validity of referenced specifications/standards of raw and subsidiary materials. Finally, proposal documents were made for invalid referenced specifications/standards of raw and subsidiary materials in order to suggest alternative specifications/standards. Results: All of the specifications/standards referenced in the Korean military drawings were 11,924 kinds and raw and subsidiary specifications/standards were 2,711 kinds. The proposal documents for revision of invalid referenced specifications/standards were suggested and approved by the military procurement standardization committee of DAPA (Defense Acquisition Program Administration). Therefore, the revision process of 472 kinds of referenced specifications/standards and 160,177 papers of the Korean military drawings were finished. Conclusion: Based on the results of this investigation, it could be significantly reduce to administrative costs and efforts through revision of referenced specifications/standards instead of conventional engineering change.

A Study on the Activity of Health Management in Small Scale Industries (소규모 사업장 보건관리 지도내용 분석)

  • Kim Myung Soon;Lee Myung Sook;Kim Hyun Li;Cho Yoo Hyang
    • Journal of Korean Public Health Nursing
    • /
    • v.12 no.2
    • /
    • pp.12-26
    • /
    • 1998
  • The occupational health problems are the major issue in the modern industrial society. Especially the small scale industries have many hazardous factors and not any occupational health programs in itself. Fortunately. the government-funded subsidiary program was developed and carried out in the past six years in our country. The purposes of this study were to find out the actual condition of the occupational health personnel's accomplishments for the government-funded subsidiary program for small scale industries and to provide basic data for setting up more developed subsidiary occupational health program. Data were collected through 6 kinds of service records review. These service records were written by 3 occupational health personnels were attached to the one subject center of KIHA. were undertaken during March to December, 1997. at 95 small scale industries which were applied the government-funded subsidiary occupational health program. Results were as follows 1. Concerning 95 small scale industries showed characteristics of a typical small scale industry. 2. A doctor visited in industries total 190 times per year, average 19 industries per month, twice per year and industry. A hygienist visited in industries total 378 times per year, average 38 industries per month, four times per year and industry. A nurse visited in industries total 477 times per year. average 47 industries per month, 5 times per year and industry. 3. 3 occupational health personnels accomplished total 3,869 items. A doctor accomplished total 539 items per year, each time 3 items In an industry. A hygienist accomplished total 1.581 items per year, each time 4 items in an industry. A nurse accomplished total 1.749 items per year, each time 4 items in an industry. 4. The major contents of doctor's accomplishment were 'health consultation for suspicious worker with general & occupational disease', 'a check of the workplace & special health education', 'guidance of special medical examination in the second half of year', etc. The major contents of hygienist's accomplishment were 'pretest & guidance of planning for evaluation of working environment'. 'evaluation for ventilating facilities & suporting self inspection', 'guidance of MSDS recording & chemicals management', etc. The major contents of nurse's accamplishment were 'health counseling of general & special medical examination results'. 'health education of preventing occupational disease & health disorder'. 'guidance of subsidiary program planning', 'selecting & guidance of health monitor', etc. It was concluded that the occupaional health personnels implemented the subsidiary program according to the order of health management guide. The current health management guide of subsidiary occupational health program in which the fixed contents, visiting number & periods is not desirable. That guide is left the characteristics of small scale industries out of consideration. It is suggested that occupational health management guide should be developed according to the general & environmental characteristics of each small scale industry, and on the other hand, the more specific guide for each occupational health personnel should be developed.

  • PDF

Copper Oxide Growing Properties by Series Arc at the Contacts of Wires in 44V AC and DC (44V AC 및 DC 전원에서 직렬아크에 의한 전선 접속부에서의 산화물 성장 특성)

  • Kim, Hyang-Kon;Gil, Hyoung-Jun;Kim, Dong-Ook;Kim, Dong-Woo;Choi, Hyo-Sang
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.2138-2139
    • /
    • 2011
  • 본 논문에서는 44V AC 및 DC전원에서 직렬아크에 의한 전선 접속부에서의 산화물 성장 특성에 대하여 실험, 분석하였다. 실험에 사용된 전선은 동전선과 황동선으로 각각 지름 1.0mm을 사용하였으며, 교류의 경우 3가지 접속조건, 직류의 경우 4가지의 접속 조건으로 하여 전선 접촉면에서 직렬아크가 발생하였을 때 2A, 3A, 4A의 전류에서 산화물의 성장 특성과 접촉면 양단의 전압강하 변화, 산화물의 성장 길이 및 방향, 온도 분포 등에 대하여 분석하였다. 실험, 분석결과, 동전선과 동전선의 접속에서 가장 산화물의 성장이 잘 이루어짐을 볼 수 있었으며, 교류에서는 접촉면을 중심으로 좌우로, 직류에서는 접촉면을 중심으로 +극(양극) 방향으로만 산화물이 성장함을 볼 수 있었다. 본 연구 결과는 AC 및 DC 전원에서의 전기안전을 위한 기술 자료로 활용할 수 있을 것으로 기대된다.

  • PDF

Study on Standard for Ensured Safety of Electric Vehicle Charger (전기자동차 충전전원 공급설비의 안전성 확보를 위한 기준 연구)

  • Lee, Ki-Yeon;Kim, Hyang-Kon;Gil, Hyung-Jun;Kim, Dong-Ook
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.2148-2149
    • /
    • 2011
  • 환경오염에 대한 규제가 강화됨에 따라 친환경자동차의 개발과 보급이 활발하게 이루어지고 있기 때문에 전기에너지를 구동에너지로 사용하는 전기자동차의 보급을 위한 필수 요소인 전기자동차 충전 설비의 보급이 지속적으로 증가하고 있고 있지만, 전기자동차 충전설비의 안전성 확보를 위한 제도가 확립되어 있지 않은 상태에서 시범 보급되고 있는 현실이다. 따라서, 본 연구에서는 국내외 전기자동차 및 전기자동차 충전전원 공급설비관련 기준 및 표준 분석을 통하여 현재 전기설비기술기준 및 판단기준에 명시된 내용 분석을 통하여 전기자동차 충전전원 공급설비에 대한 안전성 확보를 위한 충전기, 충전케이블, 커플러 등의 시설기준에 대하여 나타내었다. 본 연구결과에 대한 활용에 따른 전기자동차 충전설비의 안전성 확보로 전 세계적인 기후변화 대응과 우리나라의 저탄소 녹색성장정책에 대응하기 위한 스마트그리드 산업의 활성화에 기여하고자 한다.

  • PDF

Study on the Electrical Safety Management Method through the Electrical Characteristic Analysis of LED Lamps (LED 램프의 특성 분석을 통한 전기안전 관리 방안에 관한 연구)

  • Lee, Ki-Yeon;Moon, Hyun-Wook;Kim, Dong-Woo;Lim, Young-Bea;Ryu, In-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.11
    • /
    • pp.1931-1936
    • /
    • 2016
  • In this paper, we analyzed causes of accidents that recently increased in the illegal and defective LED lamps. They were analyzed by the electrical characteristics calculation and reappearance experiments. The causes of the accidents were analyzed from the circuit affected by the variation of voltage, current and power by harmonics. We drew a conclusion for electrical safety in illegal or degraded LED lamps from the analysis result. The management factors for electrical safety in LED lamps were harmonics, reactive power and power factor. It is possible to secure the electrical safety through monitoring of power factor in failure products and available in smart meters or smart distribution boards.

A Study on Field Vibration for Fault Cause Analysis of Glass Insulator on High-speed Railway (고속철도 유리애자 파손원인을 위한 현장 진동 연구)

  • Kim, Young-Seok;Shong, Kil-Mok;Bang, Sun-Bae;Kim, Sun-Gu;Ryu, Young-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2008.05a
    • /
    • pp.189-190
    • /
    • 2008
  • This study was investigated a possibility of fault of glass insulator due to vibration on high-speed railway. The proper vibration of 1-glass insulator have many frequency band and high amplitude showed in high frequency than low frequency. The proper vibration of strut tube insulator was lowest 170Hz, highest 1.5kHz. The field signal amplitude of viaduct and open route were biggest moment pantograph of high-speed rail. The surface vibration(V3) amplitude of strut tube insulator was biggest. From the FFT analysis of viaduct and open route, the strut tube insulator effect by vertical vibration was big, the frequency was 82.5Hz and 105Hz, respectively. However, in comparison with the proper vibration of strut tube insulator, the resonance was not observed. Although the amplitude of insulator is high, the possibility of fault is low because the glass insulator deterioration by the accumulation of vibration do not happen.

  • PDF

Analysis of Fault Possibility and Vibration of Glass Insulator on High-speed Railway (고속철도용 유리애자의 진동 및 파손가능성 분석)

  • Kim, Young-Seok;Shong, Kil-Mok;Jung, Jin-Su;Kim, Sun-Gu;Jeon, Yong-Ju;Ryu, Young-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2044-2045
    • /
    • 2008
  • This paper was studied fault possibility of glass insulator through the proper vibration and field vibration comparison. The proper vibration of 1 cell glass insulator have many frequency band and high amplitude showed in high frequency than low frequency. The field signal amplitude of viaduct and open route were biggest moment pantograph of high-speed rail. From the FFT analysis of viaduct and open route, in the case of positive direction, the strut tube insulator effect by vertical vibration was big, the frequency was 82.5Hz and 105Hz, respectively. However, in the case of negative direction, the vibration did not cause big effect. In comparison with the proper vibration of glass insulator, the resonance was not observed.

  • PDF

An Influence of Electrical facilities Due to the Dust and Analysis about Domestic Regulations (분진에 의한 전기설비의 영향과 국내규정 분석)

  • Shong, Kil-Mok;Kim, Young-Seok;Jung, Jong-Wook;Jung, Jin-Su
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.387-390
    • /
    • 2008
  • This study investigated the influence of electric facilities damaged by dusts and domestic regulations. Its contents included the around circumstance of electric facilities, regulations concerned with the dust, the actual conditions at the scene, the characteristics of dusts and so on. At the set-up the electric facilities, the around circumstances are bad in summer that highly temperature and many moisture. Besides, elements that are judged the corrosive vapours of the large quantity are detected at the sampled dusts. As the results, if dusts covered with electric facilities, It will be a cause for the electric accidents. From the analyzed data of the actual conditions and the sampled dusts, electric facilities maintenance for the viewpoint of the safety can be possible.

  • PDF