• 제목/요약/키워드: sub-cooling

검색결과 439건 처리시간 0.03초

축소형 칼로리미터의 냉각성능 해석 (Cooling Performance Analysis of Sub-scale Calorimeter)

  • 조원국;문윤완
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2003년도 제20회 춘계학술대회 논문집
    • /
    • pp.9-12
    • /
    • 2003
  • KSR-III 축소형 엔진을 원형으로 하는 8채널형 칼로리미터의 냉각성능해석을 수행하였다. 축대칭 압축성 해석에 의한 연소실 벽으로의 열유속을 이용하여 3차원 냉각유로 내부의 열전달 해석을 수행하였다. 연소실벽으로의 열유속은 문헌에서 제시하는 수준으로 확인되었으며 열전달 해석을 통하여 칼로리미터 개발과 운용에 필요한 냉각수의 압력강하, 냉각수 온도상승 및 연소실벽의 최고온도를 제시하였다.

  • PDF

Intensive Monitoring Survey of Nearby Galaxies (IMSNG) : Constraints on the progenitor system of a normal Type Ia SN 2019ein from its light curve at the early phase

  • 임구;임명신;김도형;백승학;최창수;김소피아;황성용
    • 천문학회보
    • /
    • 제46권1호
    • /
    • pp.55.2-56
    • /
    • 2021
  • The progenitor of Type Ia supernovae (SNe Ia) is mainly believed to be a close binary system of acarbon-oxygen white dwarf (CO WD) and non-degenerate companion (single degenerate) or another WD (double degenerate). However, it is unclear which system is more prevalent. Here, we present a high cadence optical/Near-IR light curve of normal but slightly faint type Ia SN 2019ein from IMSNG project. We fit the early light curve (t <+8.3 days from the first detection) with various models to find the shock-heated cooling emission from SN ejecta-companion interaction. No significant shock-heated cooling emission is found, from which we constrain the progenitor star size as the following. The upper limit (Rupper,*) of the companion size in R-band is ~0.2R when forcing the first light time (tfl) to have one value and ~0.9R when using the mean value of tfl from the fitting in each band. Assuming the source of the I-band curve is almost powered from the radioactive decay, we obtained Rupper,*~1.2R. The early B-V color curve is in agreement with the model color curve of the 2M main sequence companion. These results allow us to at least rule out large stars like red giants as a companion star of the binary progenitor system of this supernova. B-R and V-R color do not show any significant signs of a red bump, which shows a thin helium shell (MHe<0.1M) for the sub-Mch WD (double detonation model). In addition, we estimated the distance to NGC 5353 as 37.098±0.028Mpc.

  • PDF

20 MeV DTL 냉각계통의 유동 특성에 관한 수치해석 (A Numerical Analysis on the Characteristics of Flow in the 20 MeV DTL Cooling System)

  • 김경렬;박준;권세진;김형균;김희섭;황운하;윤종철
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2907-2912
    • /
    • 2007
  • The cooling water system for the PEFP 20 MeV proton accelerator was established and tested to obtain the precise resonance frequency of DTL through the temperature control of cooling water. The water temperature in the main flow loop was manipulated by adjusting the proportion of hot water returning from the DTL structures through the heat exchanger loop. Due to low duty factor operation and insufficient cooling loop installation of the DTL tanks, the manual mode operation was applied to maintain the DTL temperatures close to their resonance temperatures. The optimized process conditions with flow balancing and pressure drop in the DTL cooling systems are reported.

  • PDF

고온강재의 담금질 전열에 관한 연구 (A Study on the Heat Transfer of the High Temperature Metals in Quenching - The Latent Heat of Phase Transformation and Cooling Curves -)

  • 윤석훈
    • 수산해양기술연구
    • /
    • 제27권4호
    • /
    • pp.321-327
    • /
    • 1991
  • Experiments of quenching were made with cylindrical specimens of carbon steel S45C of diameters from 12 to 30mm were performed. The specimens were heated by electric furnace and quenched by immersion method. In order to analyze the temperature profile(cooling curves) of carbon steel including the latent heat of phase transformation, nonlinear heat conduction problem was calculated by the numerical method of inverse heat conduction problem using the apparent heat capacity method. The difference between the calculated and the experimented cooling curves was caused by the latent heat of phase transformation, and the effects of the latent heat were especially manifest at the cooling curves of center of specimens. The temperature and the quantity of the latent heat of phase transformation depend on the cooling speed at A sub(1) transformation point, and the region for cooling speed to become zero was caused by the latent heat of phase transformation.

  • PDF

과냉질소 냉각시스템 가압용 기체의 절연내력특성 분석 (Analysis on the Dielectric Characteristics of Various Insulation Gases for Developing a Sub-cooled Liquid Nitrogen Cooling System)

  • 강형구;고태국
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제13권1호
    • /
    • pp.27-30
    • /
    • 2011
  • A sub-cooled liquid nitrogen cooling system is known as a most promising method to develop large scale superconducting apparatuses such as superconducting fault current limiters and superconducting cables [1]. Gaseous helium (GHe), gaseous nitrogen ($GN_2$) and sulfur hexafluoride ($SF_6$) are commonly used for designing an high voltage applied superconducting device as an injection gaseous medium [2, 3]. In this paper, the analysis on the dielectric characteristics of GHe, $GN_2$ and $SF_6$ are conducted by designing and manufacturing sphere-to-plane electrode systems. The AC withstand voltage experiments on the various gaseous insulation media are carried out and the results are analyzed by using finite element method (FEM) considering field utilization factors (${\xi}$). It is found that the electric field intensity at sparkover ($E_{MAX}$) of insulation media exponentially decreases according to ${\xi}$ increases. Also, the empirical expressions of the functional relations between $E_{MAX}$ and ${\xi}$ of insulation media are deduced by dielectric experiments and computational analyses. It is expected that the electrical insulation design of applied superconducting devices could be performed by using the deduced empirical formulae without dielectric experiments.

<001> 0.7Pb(Mg1/3Nb2/3)O3-0.3PbTiO3 단결정의 상변화 및 유전 특성 (Phase Transformation and Dielectric Properties of <001> 0.7Pb(Mg1/3Nb2/3)O3-0.3PbTiO3 Single Crystals)

  • 이은구;이재갑
    • 한국재료학회지
    • /
    • 제21권7호
    • /
    • pp.391-395
    • /
    • 2011
  • The structure and dielectric properties of poled <001>-oriented 0.7Pb($Mg_{1/3}Nb_{2/3})O_3-0.3PbTiO_3$ (PMN-0.3PT) crystals have been investigated for orientations both parallel and perpendicular to the [001] poling direction. An electric field induced monoclinic phase was observed for the initial poled sample. The phase remained stable after the field was removed. A quite different temperature dependence of dielectric constant has been observed between heating and cooling due to an irreversible phase transformation. The results of mesh scans and temperature dependence of the dielectric constant demonstrate that the initial monoclinic phase changes to a single domain tetragonal phase at 370K and to a paraelectric cubic phase at 405K upon heating. However, upon subsequent cooling from the unpoled state, the cubic phase changes to a poly domain tetragonal phase and to a rhombohedral phase. In the ferroelectric tetragonal phase with a single domain state, the dielectric constant measured perpendicular to the poling direction was dramatically higher than that of the parallel direction. A large dielectric constant implies easier polarization rotation away from the polar axis. This enhancement is believed to be related to dielectric softening close to the morphotropic phase boundary and at the phase transition temperature.

Impact of Ba Substitution on the Magnetocaloric Effect in La1-xBaxMnO3 Manganites

  • Hussain, Imad;Anwar, M.S.;Kim, Eunji;Koo, Bon Heun;Lee, Chan Gyu
    • 한국재료학회지
    • /
    • 제26권11호
    • /
    • pp.623-627
    • /
    • 2016
  • $La_{1-x}Ba_xMnO_3$ (x = 0.30, 0.35 and 0.40) samples have been prepared by solid-state reaction method. The X-ray diffraction (XRD) study showed that all the samples crystallized in a rhombohedral structure with an R-3c space group. Variation of the magnetization as a function of the temperature and applied magnetic field was carried out. All the samples revealed ferromagnetic to paramagnetic (FM-PM) phase transition at the Curie temperature $T_C{\sim}342K$. The magnetic entropy change was also studied through examination of the measured magnetic isotherms M(H, T) near $T_C$. The magnetocaloric effect was calculated in terms of the isothermal magnetic entropy change. The maximum entropy change reaches a value of 1.192 J/kgK under a magnetic field change of 2.5T for the $La_{0.6}Ba_{0.4}MnO_3$ composition. The relative cooling power (RCP) is 79.31 J/kg for the same applied magnetic field.

냉각용 초음파 웨이브가이드의 진동 특성 (Vibration characteristics of an ultrasonic waveguide for cooling)

  • 김현세;임의수
    • 한국음향학회지
    • /
    • 제39권6호
    • /
    • pp.568-575
    • /
    • 2020
  • 초음파는 다양한 산업 분야에서 널리 사용이 되고 있다. 그 중에 도전적인 분야로 전자부품의 냉각이 있다. 초음파 냉각 기술은 작동 유체로, 기존의 지구온난화를 유발하는 프레온 가스 대신에 Ar(아르곤), N2(질소) 등의 기체로 대체가 가능하다. 또한 움직이는 부품이 없어 높은 내구성을 가질 수 있다. 그러므로 이러한 환경 문제와 내구성 관점에서 초음파 냉각 장치의 개발이 필요하다. 본 논문에서는 설계와 제작 공정에 대하여 설명하고 있다. 이 시스템을 설계할 때, 냉각기 시제품을 이용하여 유효성 테스트를 수행하였다. 이 결과를 바탕으로, ANSYS 프로그램을 사용한 유한요소해석을 수행하였다. 반공진 주파수는 34.8 kHz로 예측이 되었으며, 이는 실험치인 34.6 kHz과 0.6 %의 오차로 잘 일치하였다. 또한 초음파 웨이브가이드의 반공진 주파수는 39.4 kHz로 예측이 되었고, 역시 실험치인 39.8 kHz과 1.0 %의 오차로 잘 일치함을 알 수 있었다. 이러한 결과를 바탕으로 볼 때, 개발된 초음파 웨이브가이드는 마이크로칩의 냉각에 활용 될 수 있을 것으로 보인다.

A Study on CFD Analysis to Investigate the Effects of Different Feed Rate into the High Temperature H2SO4 Transferring Pump at Fixed Frequency

  • Choi, Jung-Sik;Choi, Jae-Hyuk
    • 해양환경안전학회지
    • /
    • 제20권3호
    • /
    • pp.304-311
    • /
    • 2014
  • In this study, to apply hydrogen energy to ship engine and to generate effective hydrogen production, we investigated the effects of high temperature $H_2SO_4$ feed rate and cooling water rate to pump parts with fixed frequency needed to reciprocate motion and a simulation was conducted at each condition. In the fixed frequency and cooling water inlet flow rate of 0.5 Hz and 3.9 kg/s, we changed the high temperature $H_2SO_4$ flow rate to 47.46 kg/s (it is 105 % of 45.2 kg/s), 49.72 kg/s (110 %), and 51.98 kg/s (115 %). Also, at 0.5 Hz and 45.2 kg/s of frequency and high temperature $H_2SO_4$ flow, the thermal hydraulic analysis was performed at the condition of 95 % (3.705 kg/s), 90 % (3.51 kg/s), and 85 % (3.315 kg/s). In overall simulation cases, the physical properties of materials are more influential to the temperature increase in the pump part rather than the changes on the feed rate of high temperature $H_2SO_4$ and cooling water. A continuous operation of pump was also capable even if the excess feed of high temperature $H_2SO_4$ of about 15 % or the less feed of cooling water of about 15 % were performed, respectively. When the increasing feed of high temperature $H_2SO_4$ of up to 5 %, 10 %, and 15 % were compared with base flow (45.2 kg/s), the deviation of time period rose to a certain temperature and ranged from 0 to 4.5 s in the same position (same material). In case of cooling water, the deviation of time period rose to a certain temperature and ranged from 0 to 5.9 s according to the decreasing feed changes of cooling water at 5 %, 10 %, and 15 % compared to a base flow (3.9 kg/s). Finally, the additional researches related to the two different materials (Teflon and STS for Pitch and End-plate), which are concerned about the effects of temperature changes to the parts contacting different materials, are needed, and we have a plan to conduct a follow-up study.

KSR-III 축소형 연소기의 열유속 평가 (Heat Flux Evaluation of KSR-III Sub-scale Chamber)

  • 조원국;문일윤;김종규
    • 한국추진공학회지
    • /
    • 제8권1호
    • /
    • pp.81-84
    • /
    • 2004
  • KSR-III 축소형 연소기를 원형으로 하는 8채널 형태의 물냉각 칼로리미터를 설계/제작하였다. 설계는 1차원 경험식을 이용하였으며 시험전에 3차원 전산유동해석을 수행하여 연소시험을 위한 냉각 조건의 안전성을 확인하였다. 탄소침착물의 단열효과를 고려할 경우 노즐목 부근에서 예측한 열유속이 정확성을 가지는 것으로 확인되었으며 연소실 부근에서는 상대적으로 큰 오차를 보였다.