• 제목/요약/키워드: studs shear connectors

검색결과 58건 처리시간 0.031초

Determination of shear stiffness for headed-stud shear connectors using energy balance approach

  • Ye, Huawen;Huang, Ruosen;Tang, Shiqing;Zhou, Yu;Liu, Jilin
    • Steel and Composite Structures
    • /
    • 제42권4호
    • /
    • pp.477-487
    • /
    • 2022
  • The shear stiffness of headed-stud shear connectors has no unified definition due to the nonlinear characteristics of its load-slip relationship. A unified framework was firstly adopted to develop a general expression of shear load-slip equation for headed-stud shear connectors varying in a large parameter range based on both force and energy balance. The pre- and post-yield shear stiffness were then determined through bilinear idealization of proposed shear load-slip equation. An updated and carefully selected push-out test database of 157 stud shear connectors, conducting on studs 13~30mm in diameter and on concretes 30~180 MPa in cubic compressive strength, was used for model regression and sensitivity analysis of shear stiffness. An empirical calculation model was also established for the stud shear stiffness. Compared with the previous models through statistical analysis, the proposed model demonstrates a better performance to predict the shear load-slip response and stiffness of the stud shear connectors.

Experiments on Shear Connections of PSC Girders with Prefabricated Slabs

  • 심창수;정철헌;현병학;김영진
    • 콘크리트학회논문집
    • /
    • 제16권4호
    • /
    • pp.573-579
    • /
    • 2004
  • For the fast construction and replacement of bridges in urban area, a prefabricated bridge system can be an excellent alternative. Details of prefabricated slabs for PSC girders were developed and static tests on shear connections were conducted to propose design equations of the shear connection. Stirrups and stud connectors were used as shear connectors and non-shrink mortar was used for the filling material in shear pockets for shear connectors. Stirrups and studs were fabricated to insert embedded nut-type devices in PSC girders. Shear strength of the shear connection considering chemical bond, friction and mechanical connectors was evaluated and empirical equations were suggested. Due to the mechanical connectors, ultimate slip capacity of the shear connection was sufficient for shear load redistribution, and suggested details of the shear connection showed good performance in terms of strength and ductility.

CFT 구조에 적용된 스터드 전단연결재의 파괴 거동에 대한 실험 및 해석적 연구 (Experimental and Analytical studies on Failure Behavior of Stud Shear Connectors in CFT Structures)

  • Lee, Sangyoon
    • 한국재난정보학회 논문집
    • /
    • 제9권4호
    • /
    • pp.400-412
    • /
    • 2013
  • CFT 구조는 내부의 콘크리트와 강관의 합성거동을 위한 전단연결재를 필요로 한다. 하지만, 현행 설계기준에서는 통상적으로 무근콘크리트로 채워지는 CFT 구조에 적용할 수 있는 전단연결재에 대한 설계기준을 제시하고 있지 않다. 본 연구는 강-콘크리트 합성구조에 널리 사용되는 스터드 전단연결재를 CFT 구조에 적용하기 위한 설계기준 즉, CFT 구조에 적용된 스터드 전단연결재의 전단강도를 제안하기 위한 연구의 일환으로 수행되었다. 본 연구에서는 CFT 구조에 적용된 스터드의 전단강도를 결정하는 주된 파괴모드를 검토하기 위하여 무근콘크리트를 적용한 직접전단실험체를 이용하여 실험을 수행하고 파괴모드를 분석하기 위한 유한요소해석을 실시하였다. 직접전단실험 및 유한요소해석결과로부터 CFT 구조에 적용된 스터드 전단연결재의 주된 파괴모드는 콘크리트의 쪼갬파괴이며, 이러한 파괴모드로 인하여 철근콘크리트에 적용된 스터드에 비해 전단강도가 감소한다는 사실을 확인할 수 있었다.

Experimental study on steel-concrete composite beams with Uplift-restricted and slip-permitted screw-type (URSP-S) connectors

  • Duan, Linli;Chen, Hongbing;Nie, Xin;Han, Sanwei
    • Steel and Composite Structures
    • /
    • 제35권2호
    • /
    • pp.261-278
    • /
    • 2020
  • In steel-concrete composite beams, to improve the cracking resistance of the concrete slab in the hogging moment region, a new type of connector in the interface, named uplift-restricted and slip-permitted screw-type (URSP-S) connector has been proposed. This paper focuses on the behavior of steel-concrete composite beams with URSP-S connectors. A total of three beam specimens including a simply supported beam with URSP-S connectors and two continuous composite beams with different connectors arrangements were designed and tested. More specifically, one continuous composite beam was equipped with URSP-S connectors in negative moment region and traditional shear studs in other regions. For comparison, the other one was designed with only traditional shear studs. The failure modes, crack evolution process, ultimate capacities, strain responses at different locations as well as the interface slip of the three tested specimens were measured and evaluated in-depth. Based on the experimental study, the research findings indicate that the larger slip deformation is allowed while using URSP-S connectors. Meanwhile, the tensile stress reduces and the cracking resistance of the concrete slab improves accordingly. In addition, the overall stiffness and strength of the composite beam become slightly lower than those of the composite beam using traditional shear studs. Moreover, the arrangement suggestion of URSP-S connectors in the composite beam is discussed in this paper for its practical design and application.

Push-Out Test에 의한 스터드와 고장력 볼트의 역학적 거동 (Mechanical Behaviors of Studs and High-Tensile Bolts by Push-Out Test)

  • 김용희;이명동;문태경
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제3권2호
    • /
    • pp.169-175
    • /
    • 1999
  • Shear connectors are completely important to composite each other in steel concrete composite structures. Therefore a strength of shear connectors and relation of a load-slip have been carried out experimentally and analytically by the Push-Out test for this study. In this paper, eleven specimens were tested and the behavior of shear connectors in steel concrete composite structures are investigated.

  • PDF

Fatigue behavior of stud shear connectors in steel and recycled tyre rubber-filled concrete composite beams

  • Han, Qing-Hua;Wang, Yi-Hong;Xu, Jie;Xing, Ying
    • Steel and Composite Structures
    • /
    • 제22권2호
    • /
    • pp.353-368
    • /
    • 2016
  • This paper extends our recent work on the fatigue behavior of stud shear connectors in steel and recycled tyre rubber-filled concrete (RRFC) composite beams. A series of 16 fatigue push-out tests were conducted using a hydraulic servo testing machine. Three different recycled tyre rubber contents of concrete, 0%, 5% and 10%, were adopted as main variable parameters. Stress amplitudes and the diameters of studs were also taken into consideration in the tests. The results show that the fatigue lives of studs in 5% and 10% RRFC were 1.6 and 2.0 times greater of those in normal concrete, respectively. At the same time, the ultimate residual slips' values of stud increased in RRFC to highlight its better ductility. The average ultimate residual slip value of the studs was found to be equal to a quarter of studs' diameter. It had also been proved that stress amplitude was inversely proportional to the fatigue life of studs. Moreover, the fatigue lives of studs with large diameter were slightly shorter than those of smaller ones and using larger ones had the risk of tearing off the base metal. Finally, the comparison between test results and three national codes was discussed.

Vibration behavior of functionally graded sandwich beam with porous core and nanocomposite layers

  • Si, Hua;Shen, Daoming;Xia, Jinhong;Tahouneh, Vahid
    • Steel and Composite Structures
    • /
    • 제36권1호
    • /
    • pp.1-16
    • /
    • 2020
  • In steel-concrete composite beams, to improve the cracking resistance of the concrete slab in the hogging moment region, a new type of connector in the interface, named uplift-restricted and slip-permitted screw-type (URSP-S) connector has been proposed. This paper focuses on the behavior of steel-concrete composite beams with URSP-S connectors. A total of three beam specimens including a simply supported beam with URSP-S connectors and two continuous composite beams with different connectors arrangements were designed and tested. More specifically, one continuous composite beam was equipped with URSP-S connectors in negative moment region and traditional shear studs in other regions. For comparison, the other one was designed with only traditional shear studs. The failure modes, crack evolution process, ultimate capacities, strain responses at different locations as well as the interface slip of the three tested specimens were measured and evaluated in-depth. Based on the experimental study, the research findings indicate that the larger slip deformation is allowed while using URSP-S connectors. Meanwhile, the tensile stress reduces and the cracking resistance of the concrete slab improves accordingly. In addition, the overall stiffness and strength of the composite beam become slightly lower than those of the composite beam using traditional shear studs. Moreover, the arrangement suggestion of URSP-S connectors in the composite beam is discussed in this paper for its practical design and application.

Numerical investigation on seismic performance of reinforced rib-double steel plate concrete combination shear wall

  • Longyun Zhou;Xiaohu Li;Xiaojun Li
    • Nuclear Engineering and Technology
    • /
    • 제56권1호
    • /
    • pp.78-91
    • /
    • 2024
  • Double steel plate concrete composite shear wall (SCSW) has been widely utilized in nuclear power plants and high-rise structures, and its shear connectors have a substantial impact on the seismic performance of SCSW. Therefore, in this study, the mechanical properties of SCSW with angle stiffening ribs as shear connections were parametrically examined for the reactor containment structure of nuclear power plants. The axial compression ratio of the SCSW, the spacing of the angle stiffening rib arrangement and the thickness of the angle stiffening rib steel plate were selected as the study parameters. Four finite element models were constructed by using the finite element program named ABAQUS to verify the experimental results of our team, and 13 finite element models were established to investigate the selected three parameters. Thus, the shear capacity, deformation capacity, ductility and energy dissipation capacity of SCSW were determined. The research results show that: compared with studs, using stiffened ribs as shear connectors can significantly enhance the mechanical properties of SCSW; When the axial compression ratio is 0.3-0.4, the seismic performance of SCSW can be maximized; with the lowering of stiffener gap, the shear bearing capacity is greatly enhanced, and when the gap is lowered to a specific distance, the shear bearing capacity has no major affect; in addition, increasing the thickness of stiffeners can significantly increase the shear capacity, ductility and energy dissipation capacity of SCSW. With the rise in the thickness of angle stiffening ribs, the improvement rate of each mechanical property index slows down. Finally, the shear bearing capacity calculation formula of SCSW with angle stiffening ribs as shear connectors is derived. The average error between the theoretical calculation formula and the finite element calculation results is 8% demonstrating that the theoretical formula is reliable. This study can provide reference for the design of SCSW.

강합성 교량의 콘크리트 바닥판 해체 및 재시공이 용이한 분리식 볼트접합 전단연결재에 관한 실험적 연구 (An Experimental Study of Demountable Bolted Shear Connectors for the Easy Dismantling and Reconstruction of Concrete Slabs of Steel-Concrete Composite Bridges)

  • 정대성;박세현;김태형;김철영
    • 대한토목학회논문집
    • /
    • 제42권6호
    • /
    • pp.751-762
    • /
    • 2022
  • 강합성 교량에서 강 거더와 콘크리트 바닥판의 합성을 위한 전단연결재로는 용접접합 머리붙이 스터드가 주로 사용된다. 용접접합 전단연결재의 경우, 손상 또는 노후화된 바닥판 철거 시에 파쇄에 따른 소음, 비산먼지 등이 발생하여 환경적 문제가 지적되고 있다. 따라서 환경적 문제 및 생애주기비용 관점의 효율적인 유지관리를 위해서는 노후화된 콘크리트 바닥판의 교체가 용이한 분리식 전단연결재 개발이 필요하다. 기존의 볼트접합 전단연결재로는 매립너트 방식이 주로 연구되었으나 낮은 강성과 전단저항강도, 초기슬립 증가 등으로 교량과 같은 토목구조물에는 활용되지 못하고 있는 실정이다. 본 논문에서는 이러한 문제점들을 개선하기 위해 매립너트 부분이 스터드 기둥에 일체화되고 확대 기둥 하단에 테이퍼진 형상을 갖는 분리식 볼트접합 전단연결재를 제안하였다. 제안된 분리식 스터드볼트의 정적 전단강도와 슬립 변위에 대한 성능 검증을 위해 수평전단실험을 수행하였고, 기존 용접접합 스터드와 성능을 비교하였다. 제안된 분리식 볼트접합 전단연결재가 전단성능이 매우 우수하고, 슬립변위 또한 연성설계기준을 만족함으로써 기존 용접 스터드를 충분히 대체하여 적용 가능함을 확인하였다.

Bond-slip effect in steel-concrete composite flexural members: Part 2 - Improvement of shear stud spacing in SCP

  • Lee, WonHo;Kwak, Hyo-Gyoung;Kim, Joung Rae
    • Steel and Composite Structures
    • /
    • 제32권4호
    • /
    • pp.549-557
    • /
    • 2019
  • The use of shear studs usually placed in the form of mechanical shear connectors makes it possible to adopt composite steel-concrete structures in various structures, and steel-concrete plate composite (SCP) is being seriously considered for the installation of storage tanks exposed to harsh environments. However, manufacturing of SCP must be based on the application of existing design guidelines which require very close arrangement of shear studs. This means that the direct application of current design guidelines usually produces very conservative results and close arrangement of shear studs precludes pouring concrete within exterior steel faceplates. In this light, an improved guideline to determine the stud spacing should be introduced, and this paper proposes an improved ratio of the stud spacing to the thickness of steel plate on the basis of numerous parametric studies to evaluate the relative influence of the stud spacing on the stability of the SCP.