Browse > Article
http://dx.doi.org/10.12989/scs.2019.32.4.549

Bond-slip effect in steel-concrete composite flexural members: Part 2 - Improvement of shear stud spacing in SCP  

Lee, WonHo (Department of Civil and Environmental Engineering, Korea Advanced Institute of Science and Technology)
Kwak, Hyo-Gyoung (Department of Civil and Environmental Engineering, Korea Advanced Institute of Science and Technology)
Kim, Joung Rae (Department of Civil and Environmental Engineering, Korea Advanced Institute of Science and Technology)
Publication Information
Steel and Composite Structures / v.32, no.4, 2019 , pp. 549-557 More about this Journal
Abstract
The use of shear studs usually placed in the form of mechanical shear connectors makes it possible to adopt composite steel-concrete structures in various structures, and steel-concrete plate composite (SCP) is being seriously considered for the installation of storage tanks exposed to harsh environments. However, manufacturing of SCP must be based on the application of existing design guidelines which require very close arrangement of shear studs. This means that the direct application of current design guidelines usually produces very conservative results and close arrangement of shear studs precludes pouring concrete within exterior steel faceplates. In this light, an improved guideline to determine the stud spacing should be introduced, and this paper proposes an improved ratio of the stud spacing to the thickness of steel plate on the basis of numerous parametric studies to evaluate the relative influence of the stud spacing on the stability of the SCP.
Keywords
steel-concrete plate composite; shear stud spacing; local buckling; design guideline;
Citations & Related Records
Times Cited By KSCI : 6  (Citation Analysis)
연도 인용수 순위
1 Yousefi, M. and Ghalehnovi, M. (2018), "Finite element model for interlayer behavior of double skin steel-concrete-steel sandwich structure with corrugated-strip shear connectors", Steel Compos. Struct., Int. J., 27(1), 123-133. https://doi.org/10.12989/scs.2018.27.1.123
2 Zhang, K., Varma, A.H., Malushte, S.R. and Gallocher, S. (2014), "Effect of shear connectors on local buckling and composite action in steel concrete composite walls", Nuclear Eng. Des., 269, 231-239. https://doi.org/10.1016/j.nucengdes.2013.08.035   DOI
3 AASHTO (2012), AASHTO LRFD bridge design specifications, American Association of State Highway and Transportation Officials, Washington, D.C., USA.
4 AISC 360 (2010), Specification for structural steel buildings, American Institute of Steel Construction; Chicago, IL, USA.
5 Akiyama, H., Sekimoto, H., Fukihara, M., Nakanishi, K. and Hara, K. (1991), "A compression and shear loading tests of concrete filled steel bearing wall", Transactions of the 11th Structural Mechanics in Reactor Technology, 323-328.
6 BS5400 (2005), Steel, concrete and composite bridges, Part 5, Code of practice for the design of composite bridges. British Standard Institution, London, UK
7 Cho, S.-G., Lim, J.-S., Jeong, Y.-D., and Yi, S.-T. (2014), "Analytical Study for Design of Shape and Arrangement Spacing of Studs in Steel Plate Concrete(SC) Wall subjected to Shear and Axial Forces", J. Korea Inst. Struct. Mainten. Inspect., 18(4), 67-76. https://doi.org/10.11112/jksmi.2014.18.4.067   DOI
8 Hwang, J.W. and Kwak, H.G. (2013), "Improved FE model to simulate interfacial bond-slip behavior in composite beams under cyclic loadings", Comput. Struct., 125, 164-176. https://doi.org/10.1016/j.compstruc.2013.04.020   DOI
9 Choi, B.J. and Han, H.S. (2009), "An experiment on compressive profile of the unstiffened steel plate-concrete structures under compression loading", Steel Compos. Struct., Int. J., 9(6), 519-534. https://doi.org/10.12989/scs.2009.9.6.519   DOI
10 Eurocode 4 (2004), Design of composite steel and concrete structures Part 1-1 : General rules and rules for buildings. European Committee for Standardization; Brussels, Belgium.
11 Kwak, H.G. and Hwang, J.W. (2010), "FE model to simulate bond-slip behavior in composite concrete beam bridges", Comput. Struct., 88(17-18), 973-984. https://doi.org/10.1016/j.compstruc.2010.05.005   DOI
12 Kanchi, M. (1996), "Experimental study on a concrete filled steel structure Part. 2 Compressive Tests (1)", Summary of Technical Papers of Annual Meeting, Architectural Institute of Japan, Structures, pp. 1071-1072.
13 KEPIC-SNG (2010), Specification for safety-related steel plate concrete structures for nuclear facilities, Korea Electric Association, Seoul, Republic of Korea.
14 Kim, W.B. and Choi, B.J. (2011), "Shear strength of connections between open and closed steel-concrete composite sandwich structures", Steel Compos. Struct., Int. J., 11(2), 169-181. https://doi.org/10.12989/scs.2011.11.2.169   DOI
15 Lee, W.H., Kwak, H.G. and Hwang, J.Y. (2019), "Bond-slip Effect in Steel-Concrete Composite Flexural Members: (1) Simplified Numerical Model", Steel Compos. Struct., Int. J., 32(4), 537-548. https://doi.org/10.12989/scs.2019.32.4.537
16 Liang, Q.Q., Uy, B., Wright, H.D. and Bradford, M.A. (2004), "Local buckling of steel plates in double skin composite panels under biaxial compression and shear", J. Struct. Eng., 130(3), 443-451. https://doi.org/10.1061/(ASCE)0733-9445(2004)130:3(443)   DOI
17 Liew, J.R., Yan, J.B. and Huang, Z.Y. (2017), "Steel-concrete-steel sandwich composite structures-recent innovations", J. Constr. Steel Res., 130, 202-221. https://doi.org/10.1016/j.jcsr.2016.12.007   DOI
18 Oduyemi, T.O.S. and Wright, H.D. (1989), "An experimental investigation into the behaviour of double-skin sandwich beams", J. Constr. Steel Res., 14(3), 197-220. https://doi.org/10.1016/0143-974X(89)90073-4   DOI
19 Oehlers, D.J. and Bradford, M.A. (1999), Elementary behaviour of composite steel and concrete structural members, Butterworth-Heinemann.
20 Qin, Y., Li, Y.-W., Lan, X.-Z., Su, Y.-S., Wang, X.-Y. and Wu, Y.-D. (2019), "Structural behavior of the stiffened double-skin profiled composite walls under compression", Steel Compos. Struct., Int. J., 31(1), 1-12. https://doi.org/10.12989/scs.2019.31.1.001
21 Roberts, T.M., Edwards, D.N. and Narayanan, R. (1996), "Testing and analysis of steel-concrete-steel sandwich beams", J. Constr. Steel Res., 38(3), 257-279. https://doi.org/10.1016/0143-974X(96)00022-3   DOI
22 Shanmugam, N.E., Kumar, G. and Thevendran, V. (2002), "Finite element modelling of double skin composite slabs", Finite Elem. Anal. Des., 38(7), 579-599. https://doi.org/10.1016/S0168-874X(01)00093-2   DOI
23 Simulia, D. (2017), Abaqus 6.17 Documentation, DS SIMULIA Corp., USA.
24 Timoshenko, S.P. and Gere, J.M. (2009), Theory of Elastic Stability, Courier Corporation, MA, USA.
25 Usami, S., Hara, K., Sasaki, N., Akiyama, H., Narikawa, M. and Takeuchi, M. (1995), "Study on a concrete filled steel structure for nuclear power plants (part 2). Compressive loading tests on wall members", Transactions of the 13. International Conference on Structural Mechanics in Reactor Technology. v. 4.
26 Weitzenbock, J.R. and Grafton, T. (2010), "Assessment of the INCA steel-concrete-steel sandwich technology-a public report", DNV, Det Norske Veritas, NO-1322, Hovik, Norway.
27 Yan, J.B., Liew, J.R., Zhang, M.H. and Sohel, K.M.A. (2015), "Experimental and analytical study on ultimate strength behavior of steel-concrete-steel sandwich composite beam structures", Mater. Struct., 48(5), 1523-1544. https://doi.org/10.1617/s11527-014-0252-4   DOI
28 Yan, J.-B., Wang, Z., Wang, T. and Wang, X.-T. (2018), "Shear and tensile behaviors of headed stud connectors in double skin composite shear wall", Steel Compos. Struct., Int. J., 26(6), 759-769. https://doi.org/10.12989/scs.2018.26.6.759
29 Yang, Y., Liu, J. and Fan, J. (2016), "Buckling behavior of double-skin composite walls: An experimental and modeling study", J. Constr. Steel Res., 121, 126-135. https://doi.org/10.1016/j.jcsr.2016.01.019   DOI