Browse > Article
http://dx.doi.org/10.12652/Ksce.2022.42.6.0751

An Experimental Study of Demountable Bolted Shear Connectors for the Easy Dismantling and Reconstruction of Concrete Slabs of Steel-Concrete Composite Bridges  

Jung, Dae Sung (KOCED CMI)
Park, Se-Hyun (KOCED CMI)
Kim, Tae Hyeong (KOCED CMI)
Kim, Chul Young (Myongji University)
Publication Information
KSCE Journal of Civil and Environmental Engineering Research / v.42, no.6, 2022 , pp. 751-762 More about this Journal
Abstract
Welded head studs are mainly used as shear connectors to bond steel girders and concrete slabs in steel-concrete composite bridges. For welded shear connectors, environmental problems include noise and scattering dust which are generated during the removal of damaged or aged slabs. Therefore, it is necessary to develop demountable shear connectors that can easily replace aged concrete slabs for efficient maintenance and thus for better management of environmental problems and life cycle costs. The buried nut method is commonly studied in relation to bolted shear connectors, but this method is not used in civil structures such as bridges due to low rigidity, low shear resistance, and increased initial slip. In this study, in order to mitigate these problems, a demountable bolted shear connector is proposed in which the buried nut is integrated into the stud column and has a tapered shape at the bottom of an enlarged column shank. To verify the performance of the proposed demountable stud bolts in terms of static shear strength and slip displacement, a horizontal shear test was conducted, with the performance outcomes compared to those of conventional welded studs. It was confirmed that the proposed demountable bolted shear connector is capable of excellent shear performance and that it satisfies the slip displacement and ductility design criteria, meaning that it is feasible as a replacement for existing welding studs.
Keywords
Steel-concrete composite bridge; Welded head stud; Bolted shear connector; Demountable shear connector; Horizontal shear test;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Ahn, J. H., Choi, K. T., Kim, S. H. and Kim, S. H. (2008). "Shear capacity of corrugated rib shear connector." Journal of the Korean Society of Civil Engineers, KSCE, Vol. 28, No. 3A, pp. 375-381 (in Korean).
2 Cho, S. K., Lee, J. M., Youn, S. G. and Choi, Y. W. (2008). "Behavior of stud shear connectors in precast deck using lightweight concrete." Journal of Korean Society of Steel Construction, Vol. 20, No. 2, pp. 227-236 (in Korean).
3 Chung, C. H. and Lee, H. S. (2005). "Evaluation of shear strength of the ㄱ-type Perfobond rib shear connectors." Journal of the Korean Society of Civil Engineers, KSCE, Vol. 25, No. 5A, pp. 879-888 (in Korean).
4 Chung, C. H., Lee, H. S., You, S. K. and Choi, W. H. (2005a). "Experimental analysis of ㄱ-type Perfobond rib shear connection between steel tubes and concrete deck." Journal of the Korean Society of Civil Engineers, KSCE, Vol. 25, No. 1A, pp. 201-212 (in Korean).
5 Chung, C. H., Kim, J. S., Park, H. S. and Joo, B. C. (2005b). "Strength of bolt type shear connector in precast deck composite bridges." Journal of the Korean Society of Civil Engineers, KSCE, Vol. 25, No. 5A, pp. 787-800 (in Korean).
6 Csillag, F. and Pavlovic, M. S. (2021). "Push-out behaviour of demountable injected vs. blind-bolted connectors in FRP decks." Composite Structures, Vol. 270, 114043.
7 EN 1994-1-1. (2004). Eurocode-4: Design of composite steel and concrete structures, CEN, Brussels, Belgium.
8 Hawkins, N. M. (1987). "Strength in shear and tension of cast-in-place anchor bolts." Anchorage to Concrete SP-103, Vol. 103, pp. 233-256.
9 Jung, D. S., Park, S. H., Kim, T. H., Han, J. W. and Kim, C. Y. (2022). "Demountable bolted shear connector for easy deconstruction and reconstruction of concrete slabs in steel-concrete bridges." Applied Sciences, Vol. 12, No. 3, 1508. DOI: https://doi.org/10.3390/app12031508.   DOI
10 KDS 14 31 10. (2017). Design standard of structural steel members (LRFD), Korea Construction Standards Center, Goyang-si, Korea.
11 Kim, H. Y. and Koo, H. B. (2006). "Composite behavior of Perfobond rib shear connector for steel-concrete decks." Journal of the Korean Society of Civil Engineers, KSCE, Vol. 26, No. 1A, pp. 91-97 (in Korean).
12 Kwon, G. U. (2008). Strengthening existing steel bridge girders by the use of post-installed shear connectors, Ph.D. Thesis, The University of Texas, Austin, TX, USA.
13 Lam, D., Dai, X. and Saveri, E. (2013). "Behaviour of demountable shear connectors in steel-concrete composite beams." International Conference on Composite Construction in Steel and Concrete VII, ASCE, pp. 613-631.
14 Lee, P. G., Shim, C. S. and Yoon, T. Y. (2003). "Static behavior of large stud shear connectors." Journal of Korean Society of Steel Construction, Vol. 15, No. 6, pp. 611-620 (in Korean).
15 Loqman, N., Safiee, N. A., Bakar, N. A. and Nasir, N. A. M. (2018). "Structural behavior of steel-concrete composite beam using bolted shear connectors: A review." MATEC Web of Conferences 203, 06010.
16 Marshall, W. T., Nelson, H. M. and Banarjee, H. K. (1971). "An experimental study of the use of high strength friction-grip bolts as shear connectors in composite beams." Structural Engineer, Vol. 49, pp. 171-178.
17 Nguyen, H. T. and Kim, S. E. (2009). "Finite element modeling of push-out tests for large stud shear connectors." Journal of Constructional Steel Research, Vol. 65, No. 10-11, pp. 1909-1920.   DOI
18 Shim, C. S. (2004). "Experiments on limits state design of large stud shear connectors." KSCE Journal of Civil Engineering, KSCE, Vol. 8, No. 3, pp. 313-318.   DOI
19 Pavlovic, M. S. (2013). Resistance of bolted shear connectors in prefabricated steel-concrete composite decks, Ph.D. Thesis, University of Belgrade, Republic of Serbia.