• Title/Summary/Keyword: structure-dependent coefficient

Search Result 100, Processing Time 0.026 seconds

Evaluation of Relationship between Strength and Resistance to Chloride in Concrete Containing Fly Ash with Ages (Fly Ash를 혼입한 콘크리트의 재령에 따른 강도와 염화물 저항능력간의 상관관계 평가)

  • Yoon, Yong-Sik;Park, Jae-Sung;Hwang, Chul-Sung;Kwon, Seung-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.4
    • /
    • pp.53-60
    • /
    • 2017
  • Fly ash(FA) which is a byproduct in the coal combustion in thermal power plant contributes to pore structure densification due to pozzolanic reaction, and this leads to long-term strength development and excellent resistance to chloride penetration. In the work, compressive strength and chloride resistance in OPC(Ordinary Portland Cement) and FA-based concrete are evaluated, and the relationships are investigated considering ages. For the work, 3 different W/B (Water to Binder) ratios of 37%, 42%, and 47% are prepared, and 3 substitution ratio of fly ash(0%, 30%, and 50%) are considered as well. At the age of 28 days and 180 days, test results of compressive strength, diffusion coefficients based on Tang's method, and passed charges referred to ASTM C 1202 and KS F 2711 are obtained. With increasing replacement ratio of FA and decreasing W/B, the resistances to chlorides(diffusion coefficient and passed charge) are improved, and the results at the age of 180 days decrease to only 15% level at the age of 28 days due to pozzolanic reaction in FA 50 mixture, which shows that resistance to chloride is much dependent on age effect than strength development. After 180 days, more clear linear relationships are observed between strength and resistance to chloride.

A Study on Relationships Between Environment, Organizational Structure, and Organizational Effectiveness of Public Health Centers in Korea (보건소의 환경, 조직구조와 조직유효성과의 관계)

  • Yun, Soon-Nyoung
    • Research in Community and Public Health Nursing
    • /
    • v.6 no.1
    • /
    • pp.5-33
    • /
    • 1995
  • The objective of the study are two-fold: one is to explore the relationship between environment, organizational structure, and organizational effectiveness of public health centers in Korea, and the other is to examine the validity of contingency theory for improving the organizational structure of public health care agencies, with special emphasis on public health nursing administration. Accordingly, the conceptual model of the study consisted of three different concepts: environment, organizational structure, and organizational effectiveness, which were built up from the contingency theory. Data were collected during the period from 1st of May through 30th of June, 1990. From the total of 249 health centers in the country, one hundred and five centers were sampled non proportionally, according to the geopolitical distribution. Out of 105, 73 health centers responded to mailed questionnaire. The health centers were the unit of the study, and a various statistical analysis techniques were used: Reliability analysis(Cronbach's Alpha) for 4 measurement tools; Shapiro-Wilk statistic for normality test of measured scores of 6 variables: ANOVA, Pearson Correlaion analysis, regressional analysis, and canonical correlation analysis for the test of the relationships and differences between the variables. The results were. as follows : 1. No significant differences between forma lization, decision-making authority and environmental complexity were found(F=1.383, P=.24 ; F=.801, P=.37). 2. Negative relationships between formalization and decision-making authority for both urban and rural health centers were found(r=-.470, P=.002 ; r=-.348, P=.46). 3. No significant relationship between formalization and job satisfaction for both urban and rural health centers were found (r=-.242, P=.132, r=-.060, P=.739). 4. Significant positive relationship between decision - making authority and job satisfaction were found in urban health centers (r=.504, P=.0009), but no such relationship was observed in rural health centers. Regression coefficient between them was statistically significant($\beta=1.535$, P=.0002), and accuracy of regression line was accepted (W=.975, P= .420). 5. No significant relationships among formalization and family planning services, maternal health services, and tuberculosis control services for both urban and rural health centers were found. 6. Among decision-making authority and family planning services, maternal health services, and tuberculosis control services, significant positive relationship was found between de cision-making authority and family planning services(r=.286, P=.73). 7. A significant difference was found in maternal health services by the type of health centers (F=5.13, P=.026) but no difference was found in tuberculosis control services by the type of health centers, formalization, and decision-making authority. 8. A significant positive relationships were found between family planning services and maternal health services and tuberculosis control services, and between maternal health services and tuberculosis control services (r=-.499, P=.001 ; r=.457, P=.004 ; r=.495, P=.002) in case of urban health centers. In case of rural health centers, relationships between family planning services and tuberculosis control services, and between maternal health services and tuberculosis control services were statistically significant (r=.534, P=.002 ; r=.389, P=.027). No significant relationship was found between family planning and maternal health services. 9. A significant positive canonical correlation was found between the group of independent variables consisted of formalization and de cision-making authority and the group of dependent variables consisted of family planning services, maternal health services and tuberculosis control services(Rc=.455, P=.02). In case of urban health centers, no significant canonical correlation was found between them, but significant canoncial correlation was found in rural health centers(Rc=.578, P=.069), 10. Relationships between job satisfaction and health care productivity was not found significant. Through these results, the assumed relationship between environment and organizational structure was not supported in health centers. Therefore, the relationship between the organizational effectiveness and the congruence between environment and organizational structure that contingency theory proposes to exist was not able to be tested. However decision-making authority was found as an important variable of organizational structure affecting family planning services and job satisfaction in urban health centers. Thus it was suggested that decentralized decision making among health professionals would be a valuable strategy for improvement of organizational effectiveness in public health centers. It is also recommended that further studies to test contingency theory would use variability and uncertainty to define environment of public health centers instead of complexity.

  • PDF

The surface kinetic properties of $ZrO_2$ Thin Films in dry etching by Inductively Coupled Plasma

  • Yang-Xue, Yang-Xue;Kim, Hwan-Jun;Kim, Dong-Pyo;Um, Doo-Seung;Woo, Jong-Chang;Kim, Chang-Il
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.105-105
    • /
    • 2009
  • $ZrO_2$ is one of the most attractive high dielectric constant (high-k) materials. As integrated circuit device dimensions continue to be scaled down, high-k materials have been studied more to resolve the problems for replacing the EY31conventional $SiO_2$. $ZrO_2$ has many favorable properties as a high dielectric constant (k= 20~25), wide band gap (5~7 eV) as well as a close thermal expansion coefficient with Si that results in good thermal stability of the $ZrO_2/Si$ structure. In order to get fine-line patterns, plasma etching has been studied more in the fabrication of ultra large-scale integrated circuits. The relation between the etch characteristics of high-k dielectric materials and plasma properties is required to be studied more to match standard processing procedure with low damaged removal process. Due to the easy control of ion energy and flux, low ownership and simple structure of the inductively coupled plasma (ICP), we chose it for high-density plasma in our study. And the $BCl_3$ included in the gas due to the effective extraction of oxygen in the form of $BCl_xO_y$ compound In this study, the surface kinetic properties of $ZrO_2$ thin film was investigated in function of Ch addition to $BCl_3/Ar$ gas mixture ratio, RF power and DC-bias power based on substrate temperature. The figure 1 showed the etch rate of $ZrO_2$ thin film as function of gas mixing ratio of $Cl_2/BCl_3/Ar$ dependent on temperature. The chemical state of film was investigated using x-ray photoelectron spectroscopy (XPS). The characteristics of the plasma were estimated using optical emission spectroscopy (OES). Auger electron spectroscopy (AES) was used for elemental analysis of etched surface.

  • PDF

Microwave Dielectric Properties of (Pb0.4Ca0.6)[(Fe1/2Nb1/2)1-x(Mg1/3Nb2/3)x]O3 Ceramics

  • Kim, Eung-Soo;Han, Ki-Moon;Kim, Jong-Hee;Yoon, Ki-Hyun
    • Journal of the Korean Ceramic Society
    • /
    • v.40 no.4
    • /
    • pp.323-327
    • /
    • 2003
  • Microwave dielectric properties of (P $b_{0.4}$C $a_{0.6}$)[($Fe_{\frac{1}{2}}$N $b_{\frac{1}{2}}$)$_{1-x}$ (M $g_{1}$ 3/N $b_{2}$ 3/)x] $O_3$ (PCFMN) ceramics were investigated as a function of (M $g_{1}$ 3/N $b_{2}$ 3/)$^{4+}$ content (0.1$\leq$x$\leq$0.8). A single perovskite phase with the cubic structure was obtained through the given composition range. The unit cell volume was increased with (M $g_{1}$ 3/N $b_{2}$ 3/)$^{4+}$, due to the larger average ionic size of (M $g_{1}$ 3/N $b_{2}$ 3/)$^{4+}$ than that of ($Fe_{\frac{1}{2}}$N $b_{\frac{1}{2}}$)$^{4+}$ for B-site ion. Dielectric constant (K) and Temperature Coefficient of Resonant Frequency(TCF) of PCFMN ceramics were dependent on (M $g_{1}$ 3/N $b_{2}$ 3/)$^{4+}$ content due to the decrease of ionic polarizability and B-site bond valence, respectively. Qf value was decreased with (M $g_{1}$ 3/N $b_{2}$ 3/)$^{4+}$ content due to the decrease of grain size. Typically, K of 73.56, Qf of 5,074 GHz and TCF of -6.45 ppm/$^{\circ}C$ were obtained for the specimens with x=0.4 sintered at 125$0^{\circ}C$ for 3 h.125$0^{\circ}C$ for 3 h.

Shear Performance of Board-type Two-way Voided Slab (일체형 중공재의 중공부 내부형상에 따른 이방향 중공슬래브의 전단성능 평가)

  • Choi, Hyeon-Min;Park, Tae-Won;Paik, In-Kwan;Kim, Je-Sub;Han, Ju-Yeon
    • Journal of the Korea Concrete Institute
    • /
    • v.27 no.6
    • /
    • pp.651-659
    • /
    • 2015
  • Currently, social demands for long span building structures are increasing due to architectural planning purposes and economic efficiency. As a result, lighter board-type voiding materials were suggested. With the use of board-type voiding materials, a slab is able to become light weight and convenient. This process efficiently eliminates concrete where it is not required; considerably diminishing dead weight while maintaining the flexural strength of the slab. The reduction in concrete also allows for overall cost reductions and design flexibility. Also it can be ease with fixing the voided material that is composed of one body form. Although board-type voiding materials are ideal, the top and bottom concrete plates lack integrity. Because of this, test results show horizontal cracking towards the tops and bottoms of the concrete columns, or webs, connecting the slabs. The key to correcting this problem is to increase the shear strength. In order to increase the shear strength of the structure, horizontal shear area must increase. R70(100)-D-F has the largest horizontal shear area as it also shows stronger strength. As a result, shear strength ($V_{nh}$) is dependent on the horizontal shear area (N). $V_{nh}={\alpha}{\times}0.16{\sqrt{f_{ck}}}{\frac{{\pi}D^2}{4}}{\times}N({\alpha}=1.8125)$. The web columns have a shear span to depth ratio (a/d) that is less than 2; which classifies it as a deep beam. In this case, however, the shear strength of the deep beams may be as much as 2 to 3 times greater than that predicated conventional equations developed for members of normal proportions. As a result, ${\alpha}$ is suggested as an extra coefficient in the equation for shear strength ($V_{nh}$).

The Pattern of Natural Regeneration by Canopy Gap Size in the Mixed Broadleaved-Korean Pine Forest of Xiaoxing'an Mountains, China

  • Jin, Guangze;Tian, Yueying;Zhao, Fengxia;Kim, Ji Hong
    • Journal of Korean Society of Forest Science
    • /
    • v.96 no.2
    • /
    • pp.227-234
    • /
    • 2007
  • The forest canopy gap has been well known as a substantial process of forest cyclic regeneration and important role in stand structure, dynamics, and biodiversity of the forest ecosystem. Based on 3,600 $5m{\times}5m$ square grids in a 9ha permanent experimental plot, the study was conducted to evaluate the regeneration pattern of woody species by developmental stage {seedlings (<1 m of height), saplingI (>1 m of height, <2 cm of DBH), and saplingII (2 cm$<200m^2$), $201-400m^2$, $400-600m^2$, $601-800m^2$, and $>800m^2$) in the mixed broadleaved-Korean pine forest. The results indicated that the regenerating trees of Populus ussuriensis occurred only in the canopy gap area, considered to be a typical gap-dependent species. The regeneration of Ulmus japonica, Ulmus laciniata, and Maackia amurensis could be generally satisfied with the gap size of $201-600m^2$, Betula costata and Prunus padus with gap size of $401-800m^2$, Picea koraiensis with gap size of $201-800m^2$, Fraxinus mandshurica and Syringa reticulata var. mandshurica with smaller than $800m^2$, respectively. Acer ukurunduense and Acer tegmentosum were likely to have no problem with the gap size to make gap regeneration. Acer mono and Tilia amurensis looked more capable of regenerating in the closed canopy disregarding the upper crown condition. The regeneration of Pinus koraiensis and Abies nephrolepis had no trouble under the canopy condition in less than $800m^2$of gap size. The density of regenerating shrubs was rather high, especially under the closed canopy, considered to be associated with great amount of regeneration production in such shade tolerant species as Lonicera maackii, Corylus mandshurica, Euonymus pauciflorus, and Philadelphus schrenkii under the closed canopy. Pearson correlation coefficient was computed to compare the similarity among non-gap area and five gap size classes by developmental stages for trees and shrubs. The similarity coefficients among closed canopy and the gap size classes were mostly significantly correlated to each other with a few exceptions.

A Study on Improving the Efficiency of Facility Safety Inspection Work Using Images (영상을 활용한 시설물 안전점검 작업 효율성 향상 방안 연구)

  • Jeon, Kyungsik;Kim, Jintae;Lee, Byoungkil
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.39 no.3
    • /
    • pp.179-186
    • /
    • 2021
  • In general, the daily safety inspection activities, which investigate damages in structures and measures the size of the damage, have been relied heavily on the visual inspection so far. Since the probe of the condition and performance of facilities by such personnel is often dependent on the subjective judgment of the investigator, the consistency and repeatability of the probing results may reduce. Particularly, damage located in a difficult-to-reach place depends mainly on experience with the naked eye, and an unsafe method using a ladder has mainly applied when necessary. Therefore, in this study, we tried to propose a way of using images that can reduce the deviation between safety inspection investigators, enhance objectivity, and improve the safety of workers. In this study, we have applied homographic transformation as a method of correcting the image. As a result of analyzing the size of the damage in the corrected image of the test subject, it confirms that the accuracy of measuring the magnitude of the damage can satisfy the target levels of 5.0mm and 0.005m2, the target accuracy levels. As a result of the field verification test to which the proposed image correction technique applied, the coefficient of variation of the crack length in the structure decreased from 5.4~7.0% to 0.072~0.12%, and that of the damaged area from 10.9% to 1.6%. It confirms that the measurement accuracy is improved. Therefore, it is expected that this study on the image utilization technique in safety inspection activities can increase the accuracy of damage measurement and improve the reliability of the safety inspection reports and exterior survey drawings.

A Study on the Performance & Job Satisfaction of Visiting Nurses of district health centers in Seoul (서울시 각 구 보건소간호사의 방문간호 업무수행과 직무만족에 관한 연구)

  • Yang, Mi-Jin
    • Journal of Korean Academic Society of Home Health Care Nursing
    • /
    • v.4
    • /
    • pp.30-40
    • /
    • 1997
  • The change in health care environment increases the importance of Visiting Nursing Services Program. It has been performed by nurses of district health centers in Seoul since 1991. The Achievement of Visiting Nursing Services Program will be dependent upon their activities. The purpose of this study was to identify the Performance of Visiting Nurses and Job satisfaction of district health centers in Seoul. Therefore, it was to provide the fundamental data development of Visiting Nursing Services Program. The subjects were 214 Visiting Nurses of district health centers in Seoul. The data was collected by self reporting questionnaire from April 15 to April 30, 1997. Their performances and various supportive factors were measured with the instruments developed by the researcher. Job satisfaction were also measured by the instrument developed by Slavitt et al. (1978) was used. The data were, analyzed by Cronbach Alpha, mean, standard deviation, percentage, t -test, ANOVA Duncan test, Correlation Coefficient, and Stepwise Multiple Regression with SAS program. The results of this study were as follows: 1. The average of budget of Visiting Nursing Services Program of district health centers was 0.9% and the average of visiting nursing services personnel of district health centers was 10.1%. 2. With regard to the job satisfaction of Visiting Nurses the mean score was 2.92 out of 5. While the level of Job prestige / status presented as a mean score of 3.48 which was the largest among the 7 components of job satisfaction, the level of administration was the lowest showing 2.57 scores respectively. There were significant differences in the job satisfaction by age, working career of health centers(p<0.01, 0.001). 3. The average of the performance level of Visiting Nurses variables was 2.29; The variable with highest degree of performance was the teaching & consultation, establishment of performance plan, whereas the on with the lowest degree was the directive nursing services. The significant difference was found in performance level according to age, structure type of visiting nursing services, working career of health centers and working career of visiting nursing services(p<0.05). 4. With regard to the perception of the performance expertise by the Visiting Nurses the mean score was 2.37 : The variable with highest degree of performance expertise was the teaching & consultation, establishment of performance plan, whereas the on with the lowest degree was management of home-environment. The significant difference was found in performance expertise according to working career outside of health centers(p<0.05). 5. With regard to the perception of the performance necessity by the Visiting Nurses the mean was 2. 40 : the variable with highest degree of performance necessity was the teaching & consultation, establishment of performance plan, whereas the on with the lowest degree was directive nursing services. The significant difference was found in performance necessity according to working career of visiting nursing services(p<0.05). 6. A positive correlation was found between job satisfaction and performance level(r=.3731, P<0.001). Also, a weak positive correlation was found between the components of job satisfaction and performance level. 7. Stepwise multiple regression analysis revealed that the most powerful predictor was the variance of job satisfaction(R=.3557, $R^2$=.1265). Structure type of visiting nursing services and working career of visiting nursing services accounted for 19.0% of the variance in performance level in nurses. In conclusion, Job satisfaction, Structure type of visiting nursing services and Working career of visiting nursing services variables had influenced on performance level in health centers. Further research is required to confirm these findings.

  • PDF

Predicting the Performance of Recommender Systems through Social Network Analysis and Artificial Neural Network (사회연결망분석과 인공신경망을 이용한 추천시스템 성능 예측)

  • Cho, Yoon-Ho;Kim, In-Hwan
    • Journal of Intelligence and Information Systems
    • /
    • v.16 no.4
    • /
    • pp.159-172
    • /
    • 2010
  • The recommender system is one of the possible solutions to assist customers in finding the items they would like to purchase. To date, a variety of recommendation techniques have been developed. One of the most successful recommendation techniques is Collaborative Filtering (CF) that has been used in a number of different applications such as recommending Web pages, movies, music, articles and products. CF identifies customers whose tastes are similar to those of a given customer, and recommends items those customers have liked in the past. Numerous CF algorithms have been developed to increase the performance of recommender systems. Broadly, there are memory-based CF algorithms, model-based CF algorithms, and hybrid CF algorithms which combine CF with content-based techniques or other recommender systems. While many researchers have focused their efforts in improving CF performance, the theoretical justification of CF algorithms is lacking. That is, we do not know many things about how CF is done. Furthermore, the relative performances of CF algorithms are known to be domain and data dependent. It is very time-consuming and expensive to implement and launce a CF recommender system, and also the system unsuited for the given domain provides customers with poor quality recommendations that make them easily annoyed. Therefore, predicting the performances of CF algorithms in advance is practically important and needed. In this study, we propose an efficient approach to predict the performance of CF. Social Network Analysis (SNA) and Artificial Neural Network (ANN) are applied to develop our prediction model. CF can be modeled as a social network in which customers are nodes and purchase relationships between customers are links. SNA facilitates an exploration of the topological properties of the network structure that are implicit in data for CF recommendations. An ANN model is developed through an analysis of network topology, such as network density, inclusiveness, clustering coefficient, network centralization, and Krackhardt's efficiency. While network density, expressed as a proportion of the maximum possible number of links, captures the density of the whole network, the clustering coefficient captures the degree to which the overall network contains localized pockets of dense connectivity. Inclusiveness refers to the number of nodes which are included within the various connected parts of the social network. Centralization reflects the extent to which connections are concentrated in a small number of nodes rather than distributed equally among all nodes. Krackhardt's efficiency characterizes how dense the social network is beyond that barely needed to keep the social group even indirectly connected to one another. We use these social network measures as input variables of the ANN model. As an output variable, we use the recommendation accuracy measured by F1-measure. In order to evaluate the effectiveness of the ANN model, sales transaction data from H department store, one of the well-known department stores in Korea, was used. Total 396 experimental samples were gathered, and we used 40%, 40%, and 20% of them, for training, test, and validation, respectively. The 5-fold cross validation was also conducted to enhance the reliability of our experiments. The input variable measuring process consists of following three steps; analysis of customer similarities, construction of a social network, and analysis of social network patterns. We used Net Miner 3 and UCINET 6.0 for SNA, and Clementine 11.1 for ANN modeling. The experiments reported that the ANN model has 92.61% estimated accuracy and 0.0049 RMSE. Thus, we can know that our prediction model helps decide whether CF is useful for a given application with certain data characteristics.

Microwave Dielectric Properties and Multilayer Characteristics of (1-x)BiNbO4-xCaNb2O6 Ceramics ((1-x)BiNbO4-xCaNb2O6 세라믹스의 마이크파 유전특성 및 적층체 특성)

  • Kim, Eung-Soo;Choi, Woong;Kim, Jong-Dae;Kang, Seung-Gu;Shim, Kwang-Bo
    • Journal of the Korean Ceramic Society
    • /
    • v.39 no.12
    • /
    • pp.1190-1196
    • /
    • 2002
  • Microwave dielectric properties and multilayer characteristics $(1-x)BiNbO_4-xCaNb_2O_6$ (0${\le}$x${\le}$1.0) ceramics were investigated as a function of $CaNb_2O_6$ content. In the composition range of 0.25${\le}$x${\le}$0.75, the mixture phases of $BiNbO_4$ with stibotantalate structure and $CaNb_2O_6$ with columbite structure were detected and secondary phase or phase transition were not detected. Dielectric constant (K) of $(1-x)BiNbO_4-xCaNb_2O_6$ ceramics was largely dependent on the existing phase and could be estimated by the dielectric mixing rule calculated from maxwell equation. Typically, dielectric constant (K) of 26, quality factor (Qf) of 4300 GHz and Temperature Coefficient of resonant Frequency (TCF) of -18 ppm/${\circ}C$ were obtained for $0.5BiNbO_4-0.5CaNb_2O_6$ specimens with 0.8 wt% $CuV_2O_6$ sintered at 1000${\circ}C$ for 3h. The deviation of X-Y shrinkage and camber value of the multilayers obtained from $0.5BiNbO_4-0.5CaNb_2O_6$ green sheet sintered at 850∼950${\circ}C$ for 20 min. were smaller than those of $BiNbO_4$ multilayers.