• Title/Summary/Keyword: structure thickness

Search Result 3,915, Processing Time 0.035 seconds

Investigation of Effects of Duct Thickness an Counterflow Flam Structure (닥트두께가 대향류 화염구조에 미치는 영향의 조사)

  • Park, Woe-Chul;Ko, Kyung-Chan
    • Journal of the Korean Society of Safety
    • /
    • v.17 no.4
    • /
    • pp.61-65
    • /
    • 2002
  • Nonpremixed counterflow flames at low strain rates, $ag=12s^{-1}$ and $12s^{-1}$, were numerically simulated to investigate the effects of the duct thickness on the flame structure in normal gravity. For small values of the duct thickness, the positions of the flame and stagnation point were highly sensitive to the duct thickness. When the duct thickness was greater than 6mm, however, the effects of the duct thickness on the flame structure were negligible. The computed temperature along the duct centerline agreed well with measurements.

The Vibration and Stress Analysis of Stiffened Box Structures (보강 박스 구조물의 진돔 및 응력 해석)

  • Lee, Young-Shin;Han, Jae-Do;Han, You-Hie;Suh, Jung
    • Journal of KSNVE
    • /
    • v.6 no.2
    • /
    • pp.147-161
    • /
    • 1996
  • The stress and vibration analysis of stiffened box structure is investigated by experiment and FEM analysis. The effects of stiffener number and box section shape on the structure response are presneted. The 1st natural frequency of stiffened folded byx structure with a stiffeners is 300 Hz. It is highter than that of stiffened rectangular box structure with 5 stiffeners, which is 251 Hz. Maximum deflection of folded box structure with thickness of 1 mm is lower than that of rectangular box structure with thickness of 1 or 2 mm. The natural frequencies of box structures are increeased with the number of stiffener, while the deflections are decreased with the number of box structures. When we compare between fundamental frequency (251 Hz) of stiffened (with 5 stiffeners) and one (137.64 Hz) of unstiffened rectangular box structure under clamped-clamped boundary condition, the ratio of frequency increase is 82%. The stiffened structures of 2 mm thickness can reduced to 120% of maximum deflection of 1 mm thickness rectangular box structures.

  • PDF

Reaction Zone Thickness of Turbulent Premixed Flame

  • Yamamoto, Kazuhiro;Nishizawa, Yasuki;Onuma, Yoshiaki
    • Journal of the Korean Society of Combustion
    • /
    • v.6 no.2
    • /
    • pp.36-42
    • /
    • 2001
  • Usually, we use the flame thickness and turbulence scale to classify the flame structure on a phase diagram of turbulent combustion. The flame structure in turbulence is still in debate, and many studies have been done. Since the flame motion is rapid and its reaction zone thickness is very thin, it is difficult to estimate the flame thickness. Here, we propose a new approach to determine the reaction zone thickness based on ion current signals obtained by an electrostatic probe, which has enough time and space resolution to detect flame fluctuation. Since the signal depends on the flow condition and flame curvature, it may be difficult to analyze directly these signals and examine the flame characteristics. However, ion concentration is high only in the region where hydrocarbon-oxygen reactions occur, and we can specify the reaction zone. Based on the reaction zone existing, we estimate the reaction zone thickness. We obtain the thickness of flames both in the cyclone-jet combustor and on a Bunsen burner, compared with theoretically predicted value, the Zeldovich thickness. Results show that the experimentally obtained thickness is almost the same as the Zeldovich thickness. It is concluded that this approach can be used to obtain the local flame structure for modeling turbulent combustion.

  • PDF

Experimental Study for Hydraulic Characteristics as the Permeable Underlayer Thickness of Rubble mound Structure (사석방파제 투수하부층 두께에 따른 사면상의 수리특성 실험연구)

  • 윤한삼;김종욱;류청로
    • Journal of Ocean Engineering and Technology
    • /
    • v.16 no.3
    • /
    • pp.40-45
    • /
    • 2002
  • In this study, the effects on hydraulic characteristics are discussed as the permeable underlayer thickness of the rubble mound structure changes. A series of hydraulic experiments were performed and wave run-up, reflection and set-up were investigated. Result indicated that wave run-down was affected by the water out from the permeable underlayer during down-rush. As the thickness increased, relative wave run-up decreased.

The characteristics of Efficiency through HIT layer thickness (HIT 층 두께 변화를 통한 태양전지 효율 특성)

  • Kim, Moo-Jung;Pyeon, Jin-Ho;Yi, Jun-Sin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.232-232
    • /
    • 2010
  • Simulation Program (AFORS-HET 2.4.1) was used, include the basic structure of crystalline silicon thin film as above, under the intrinsic a-Si:H films bonded symmetrical structure (Symmetrical structure) were used. The structure of ITO, a-Si p-type, intrinsic a-Si, c-Si, intrinsic a-Si, a-Si n-type, metal (Al) layer has one of the seven. When thickness for each layer was given the change, the changes of a-Si p-type layer and the intrinsic a-Si layer on top had an impact on efficiency. Efficiency ratio of p-type a-Si:H layer thickness was sensitive to, especially a-Si: H layer thickness is increased in a rapid decrease in Jsc and FF, and efficiency was also decreased.

  • PDF

The Effect of Nitric Acid Catalyst on the Properties of Lead Titanate Thin Films by Sol Gel Spin Coating (졸겔 스핀 코팅에서 질산촉매가 티탄산연 박막의 물성에 미치는 영향)

  • 이전국;정형진;김종희
    • Journal of the Korean Ceramic Society
    • /
    • v.28 no.11
    • /
    • pp.859-864
    • /
    • 1991
  • High quality lead titanate thin films were fabricated by spin coating on a silicon substrate. The resulting dried gel layers were uniform in thickness through 2$\times$2 $\textrm{cm}^2$ area, and polycrystalline perovskite structures developed almost crack free with a heat treatment above 50$0^{\circ}C$ in films with thickness above 360 nm. Metastable pyrochlore structures were observed in films with thickness of 160 nm when heat treated at 500 and $600^{\circ}C$, but these structure did not appear in films with thickness of 360 nm. The thickness dependence in crystal structure of films was studied. by varying the substrate condition and analyzing the interface between the film and substrate. In native oxide films on silicon stbstrates, amorphous dried gel layers were heterogeneously nucleated. Metastable cubic pyrochlore structure could be crystallized in amorphous native oxide.

  • PDF

Variation in the Residual Stress of Hastelloy X Superalloy Fabricated by the Laser Powder Bed Fusion Process with Sample Thickness and Support Structure (레이저 분말 베드 용융법으로 제작된 Hastelloy X 적층 소재의 시편 두께 및 서포트 구조에 따른 잔류응력 변화)

  • Jang, J. E.;Park, S. H.;Kim, D. H.
    • Transactions of Materials Processing
    • /
    • v.31 no.3
    • /
    • pp.136-142
    • /
    • 2022
  • The purpose of this study was to investigate the effects of sample thickness and support structure on the residual stress of Hastelloy X superalloy samples fabricated by laser powder bed fusion (LPBF), which is an additive manufacturing process. The residual stresses of LPBF samples with different thicknesses and support structures were measured using X-ray diffraction. The results revealed that as the thickness of sample increased from 2.5 mm to 20 mm, its tensile residual stress gradually decreased from 443.5 MPa to 182.2 MPa. Additionally, the residual stress in the bottom region of sample was higher than that in the top region, and the residual stress difference in the bottom and top regions became more pronounced as the sample thickness decreased. The residual stress of LPBF sample also varied depending on the structure of support. The residual stress of sample decreased with increasing contract area between the sample and the support, because the larger contract area led to smaller temperature gradient throughout the sample.

Development of a Thickness Mode Piezoelectric Oscillator Sensor to Detect Damages in a Structure (구조물 손상 탐지를 위한 두께 방향 모드 압전 오실레이터 센서 개발)

  • Kim, Dong-Young;Roh, Yong-Rae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.26 no.2
    • /
    • pp.95-101
    • /
    • 2007
  • This paper presents the feasibilityof a thickness mode piezoelectric oscillator to detect damages in structures. The thickness mode oscillator sensor is composed of an electronic feedback oscillator circuit and a piezoelectric thickness mode vibrator to be attached to a structure of interest. Damage to the structure causes a change in the impedance spectrum of the structure, which results in a corresponding change of a resonant frequency of the structure. The oscillator sensor can instantly detect the frequency change in a very simple manner. Feasibility of the piezoelectric oscillator sensor was verified with a sample aluminum plate where artificial cracks of different lengths and number were imposed in sequence. Validity of the measurement was confirmed through comparison of the experimental data with the results of finite element analyses of a plate with cracks.

Thermography-based coating thickness estimation for steel structures using model-agnostic meta-learning

  • Jun Lee;Soonkyu Hwang;Kiyoung Kim;Hoon Sohn
    • Smart Structures and Systems
    • /
    • v.32 no.2
    • /
    • pp.123-133
    • /
    • 2023
  • This paper proposes a thermography-based coating thickness estimation method for steel structures using model-agnostic meta-learning. In the proposed method, a halogen lamp generates heat energy on the coating surface of a steel structure, and the resulting heat responses are measured using an infrared (IR) camera. The measured heat responses are then analyzed using model-agnostic meta-learning to estimate the coating thickness, which is visualized throughout the inspection surface of the steel structure. Current coating thickness estimation methods rely on point measurement and their inspection area is limited to a single point, whereas the proposed method can inspect a larger area with higher accuracy. In contrast to previous ANN-based methods, which require a large amount of data for training and validation, the proposed method can estimate the coating thickness using only 10- pixel points for each material. In addition, the proposed model has broader applicability than previous methods, allowing it to be applied to various materials after meta-training. The performance of the proposed method was validated using laboratory-scale and field tests with different coating materials; the results demonstrated that the error of the proposed method was less than 5% when estimating coating thicknesses ranging from 40 to 500 ㎛.

Characteristic Analysis of the Asymmetric Coupled microstrip Lines with finite Metalization Thickness in the Multilayered Structure (다층구조에서 도체 두께를 고려한 비대칭 결합선로의 특성해석)

  • 윤남일;홍익표;박한규
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.3A
    • /
    • pp.424-429
    • /
    • 2000
  • In this paper, the characteristics of the asymmetric coupled microstrip(ACM) lines with finite metalization thickness are investigated using the quasi-static analysis in the multilayered structure. By mode-matching method as the quasi-static analysis. the characteristic impedances and effective dielectric constants in ACM lines are obtained as a function of metalization thickness. The numerical results show that the propagation characteristics of ACM lines in the single and multilayered structure will be changed by the variation of metalization thickness.

  • PDF