• Title/Summary/Keyword: structural safety diagnosis

Search Result 112, Processing Time 0.025 seconds

Self Diagnosing Property of Carbon and Glass Hybrid Fiber Materials for Concrete Strengthening (자기진단 재료로서의 콘크리트 보강용 탄소유리복합섬유로드의 적용성 검토)

  • Park, Seok-Kyun;Lee, Byung-Jae
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.428-431
    • /
    • 2004
  • Smart structural system is defined as structural system with a certain-level of autonomy relying on the embedded functions of sensors, actuators and processors, that can automatically adjust structural characteristics, in response to the change in external disturbance and environments, toward structural safety and serviceability as well as the extension of structural service life. In this study, carbon and glass hybrid fiber materials were investigated fundamentally for the applicability of self diagnosis in smart concrete structural system as embedded functions of sensors.

  • PDF

A Study on Safety Evaluation Methods for Electric Multiple Units (도시철도차량의 안전진단평가 기법에 관한 연구)

  • Chung J.D.;Han S.Y;Park K.J.;Park O.J.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.374-377
    • /
    • 2005
  • Automobile is in charge of most transportation system in modern urban city. However, in fact, cause of problem of road state, environment, and the other reasons, urban transit system is using as Mass Transit nowadays. Nevertheless Urban transit system is considering many kind of safety fact of that system which is increasing continuously nowadays, it occurs various train accident. This paper describes 3D Dimensional Measurement(EDM testing) and tensile testing results of carbody structure for crashed EMU(Electric Multiple Units). Tensile tests were performed on two different types of specimens in order to evaluate the strength changes before and after damages, obtained from plastic deformed area and nondeformed region of the crashed EMU. And Structural analysis of EMU was performed for the criteria of safety assessment. Structural analysis using commercial I-DEAS software provided important information on the stress distribution and load transfer mechanisms as well as the amount of damages during rolling stock crash. The testing results have been used to provide the critical information for the criteria of safety diagnosis.

  • PDF

On Study the Safety Diagnosis Assessment of EMU's Carbody (전동차의 구조체 안전진단평가 연구)

  • Chung Joog-Duk;Pyun Jang-Sik;Kim Jeong-Guk;Kim Won-kyung;Hong Yong-Ki
    • Proceedings of the KSR Conference
    • /
    • 2004.06a
    • /
    • pp.322-327
    • /
    • 2004
  • This paper describes the structural analysis result of accident EMU(Electric Multiple Units). Structural analysis of EMU was performed for the criteria of safety assessment. Structural analysis using commercial I-DEAS software provided important information on the stress distribution and load transfer mechanisms as well as the amount of damages during rolling stock crash. Tensile tests were performed on two different types of specimens in order to evaluate the strength changes before and after damages, obtained from plastic deformed area and nondeformed region of the accident EMU. The structural analysis and tensile test results have been used to provide the critical information for the criteria of safety assessment.

  • PDF

Development of Wireless Sensor Node and Field Application of Long-span Bridge using Ubiquitous Technology (유비쿼터스 기술을 이용한 무선센서노드 개발 및 장대교량 현장적용 검증 실험)

  • Jo, Byung-Wan;Park, Jung-Hoon;Shin, Byung-Chul;Kim, Heoun;Yoon, Kwang-Won;Yang, Yo-Sub
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2008.04a
    • /
    • pp.127-132
    • /
    • 2008
  • As economic rapid growth, large structures are damaged by defects from design and construction process of the formation and environments. Therefore, safety diagnosis and monitoring skills are bringing importance into relief and legislate for safety diagnosis of large structures. However, the existing monitoring systems are difficult by using wire cable because of cost, error of date, location, revise. In this paper, wireless sensor network which are accelerator, temperature sensor system using ubiquitous had been field test on Sea-Hea Grand bridge. We compare accelerator, temperature sensor system with wire and wireless sensor network.

  • PDF

An Experimental Study on the Strength Evaluation of existing Structural Members for the Remodelling Construction of Apartments Housing (공동주택의 리모델링을 위한 기존부재의 내력평가 실험연구)

  • Shin, Hyun-Seop;You, Young-Chan;Lim, Byung-Ho;Choi, Ki-Sun;Kim, Keung-Hwan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.29-32
    • /
    • 2006
  • Different from new or reconstruction of an apartment housing, the structural safety in the remodelling construction can be obtained through the repair and strengthening process based on the safety diagnosis and evaluation of structural performance. In this study, structural performance of existing members such as, reinforced concrete slabs, beams and columns are investigated through experimental tests. The structural members were obtained from the existing apartment housing which will be demolished. Test results showed that most specimens have a sufficient structural capacity except for some special case, for example, specimens with severe cracks or concrete loss due to improper casting. This same severe deteriorated or defective structure members originated from bad concrete casting or careless construction process should be repaired and strengthened before an remodelling construction.

  • PDF

Numerical investigation on behaviour of cylindrical steel tanks during mining tremors and moderate earthquakes

  • Burkacki, Daniel;Wojcik, Michal;Jankowski, Robert
    • Earthquakes and Structures
    • /
    • v.18 no.1
    • /
    • pp.97-111
    • /
    • 2020
  • Cylindrical steel tanks are important components of industrial facilities. Their safety becomes a crucial issue since any failure may cause catastrophic consequences. The aim of the paper is to show the results of comprehensive FEM numerical investigation focused on the response of cylindrical steel tanks under mining tremors and moderate earthquakes. The effects of different levels of liquid filling, the influence of non-uniform seismic excitation as well as the aspects of diagnosis of structural damage have been investigated. The results of the modal analysis indicate that the level of liquid filling is really essential in the structural analysis leading to considerable changes in the shapes of vibration modes with a substantial reduction in the natural frequencies when the level of liquid increases. The results of seismic and paraseismic analysis indicate that the filling the tank with liquid leads to the substantial increase in the structural response underground motions. It has also been observed that the peak structural response values under mining tremors and moderate earthquakes can be comparable to each other. Moreover, the consideration of spatial effects related to seismic wave propagation leads to a considerable decrease in the structural response under non-uniform seismic excitation. Finally, the analysis of damage diagnosis in steel tanks shows that different types of damage may induce changes in the free vibration modes and values of natural frequencies.

A Study of Improvement Direction of Inspection Diagnosis Report and Bridge Maintenance Detailed Guidelines (교량 점검진단 보고서 및 유지관리 세부지침 개선 방향 연구)

  • Han-Min Cho;Ki-Tae Park;Dong Woo Seo;Kyu San Jung;Jae Hwan Kim;Jin-Hyuk Lee
    • Journal of Korean Society of Disaster and Security
    • /
    • v.15 no.4
    • /
    • pp.21-30
    • /
    • 2022
  • After the collapse of the Seongsu Bridge in 1994, the 「Special Act on the Safety Control and Maintenance of Establishments」 was enacted in Korea, and many efforts have been made in the field of safety inspection and maintenance of facilities. Among these facilities, a total of 33,165 bridges, which account for the largest share next to buildings, are currently in use, and 28,150 bridges of type 2 and 3 account for about 85% of the total. However, compared to the relatively more important type 1 bridges, type 2 and 3 bridges, which occupy most of the bridges, have insufficient maintenance status regarding inspection and diagnosis. This reason appears in the subjective judgment and records of the inspection performer when performing inspection and diagnosis of bridges, and in the inspection and diagnosis report form that has not been systematically established. Therefore, in this study, we intend to derive an improvement (draft) of the inspection and diagnosis report that can be systematically and continuously utilized by correcting and supplementing the problems of the existing inspection and diagnosis report.