• Title/Summary/Keyword: structural performance test

Search Result 2,156, Processing Time 0.028 seconds

Structural Relationship between ESG Management and Safety Management and Business Performance : Focused on Regional Airport (ESG경영과 안전경영 그리고 경영성과의 구조적 관계 : 지역 공항을 중심으로)

  • Jo, Young Jin;Sung, Haeng Nam;Kwon, Jin Tack
    • The Journal of Information Systems
    • /
    • v.32 no.4
    • /
    • pp.51-67
    • /
    • 2023
  • Purpose While research on ESG management in airlines is ongoing, research on airports, especially regional ones, remains insufficient. This study's point of departure is the inquiry into how the local airport industry is addressing global environmental shifts and engaging in ESG management activities. Design/methodology/approach Based on previous studies, the relationship between ESG(Environmental, Social, Governance) management, safety management, reputation, and management performance was analyzed. We analyzed 578 questionnaires through structural equation modeling using AMOS 21.0 to test our hypotheses. Findings First, environmental, social, governance, and safety management have a positive effect on both reputation and business performance. Second, reputation has affected business performance. Third, reputation was affected in the order of governance management, safety management, environmental management, and social management.

The Experimental Study on Structural Performance of the Beam-Slab System (보-슬래브 시스템 구조성능에 관한 실험적 연구)

  • Lee, Myung Jae;Kim, Cheol Hwan;Lee, Seung Joon;Kim, Won Ki;Kim, Hee Dong
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.1 s.68
    • /
    • pp.91-101
    • /
    • 2004
  • This study sought to suggest a structural design guide and to investigate the structural performances of the new beam-slab system in order to decrease the height of floors in high-rise steel structure apartments. Experiments were performed to assess the capacity of the new beam-slab system in a steel structure with 9.8-m span, particulary structural material test, pure bending test of composite beam, three-point bending test of composite beam, and bending and shearing tests. Results showed that the suggested composite beam had stable structural behavior when stud connectors were located in the upper flange, and upper bars were calculated normally according to the design of the slab.

Experimental studies of headed stud shear connectors in UHPC Steel composite slabs

  • Gao, Xiao-Long;Wang, Jun-Yan;Yan, Jia-Bao
    • Structural Engineering and Mechanics
    • /
    • v.74 no.5
    • /
    • pp.657-670
    • /
    • 2020
  • Due to the high compressive and tensile strength of ultra-high performance concrete (UHPC), UHPC used in steel concrete composite structures provided thinner concrete layer compared to ordinary concrete. This leaded to the headed stud shear connectors embedded in UHPC had a low aspect ratio. In order to systematic investigate the effect of headed stud with low aspect ratio on the structural behaviors of steel UHPC composite structure s this paper firstly carried out a test program consisted of twelve push out specimens. The effects of stud height, aspect ratio and reinforcement bars in UHPC on the structural behaviors of headed studs were investigated. The push out test results shows that the increasing of stud height did not obviously influence the structural behaviors of headed studs and the aspect ratio of 2.16 was proved enough to take full advantage of the headed stud strength. Based on the test results, the equation considering the contribution of weld collar was modified to predict the shear strength of headed stud embedded in UHPC. The modified equation could accurately predict the shear strength of headed stud by comparing with the experimental results. On the basis of push out test results, bending tests consisted of three steel UHPC composite slabs were conducted to investigate the effect of shear connection degree on the structural behaviors of composite slabs. The bending test results revealed that the shear connection degree had a significantly influence on the failure modes and ultimate resistance of composite slabs and composite slab with connection degree of 96% in s hear span exhibited a ductile failure accompanied by the tensile yield of steel plate and crushing of UHPC. Finally, analytical model based on the failure mode of composite slabs was proposed to predict the ultimate resistance of steel UHPC composite slabs with different shear connection degrees at the interface.

Determination of structural performance of 3D steel pipe rack suspended scaffolding systems

  • Arslan, Guray;Sevim, Baris;Bekiroglu, Serkan
    • Structural Engineering and Mechanics
    • /
    • v.64 no.5
    • /
    • pp.671-681
    • /
    • 2017
  • This study investigates the structural performance of 3D steel pipe rack suspended scaffolding systems. For the purpose, a standard full scale 3D steel pipe rack suspended scaffolding system considering two frames, two plane trusses, purlins and wooden floor is constructed in the laboratory. A developed load transmission system was placed in these experimental systems to distribute single loads to the center of a specific area in a step-by-step manner using a load jack. After each load increment, the displacements are measured by means of linear variable differential transducers placed in several critical points of the system. The tests are repeated for five different system conditions to determine the structural performance. The means of system conditions is the numbers of the tie bars which are used to connect plane trusses under level. Finite elements models of the 3D steel pipe rack suspended scaffolding systems considering different systems conditions are constituted using SAP2000 software to support the experimental tests and to use the models in future studies. Each of models including load transmission platform is analyzed under a single loading and the displacements are obtained. In addition, to calibrate the numerical models some uncertain parameters such as elasticity modulus of wooden floor and connection rigidity of purlins to plane trusses are assessed experimentally. The results of this work demonstrate that when increasing numbers of tie bars the displacement values are decreased. Also the results obtained from developed numerical models have harmony with those of experimental. In addition, the scaffolding system with two tie bars at the beginning and at the end of the plane truss has the optimum structural performance compared the results obtained for other scaffolding system conditions.

Basic Study on Performance Comparison of Structural Optimization Software Systems (구조최적설계 소프트웨어의 성능 비교에 대한 기초연구)

  • Choi, Wook Han;Huang, Cheng Guo;Park, Gyung-Jin;Kim, Tai-Kyung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.12
    • /
    • pp.1403-1413
    • /
    • 2014
  • Structural optimization is widely accepted in industrial fields. Structural optimization pursues improved performance of the structures. Recently, structural optimization is actively utilized due to the well-developed commercial design software systems. Three popular commercial structural optimization systems are investigated and compared. They are MSC.Nastran, Genesis and OptiStruct. The performance of the systems is analyzed based on the quality of the optimum solution and the computational time. Linear static response size, shape and topology optimizations are explored and compared with some test examples. For fair comparison, the systems are run in the same environment and the optimization parameters affecting the performance are unified. The optimization results are analyzed and the performances and characteristics of each software system are discussed.

Structural Health Monitoring System Employing Smart Sensor Technology Part 1: Development and Performance Test of Smart Sensor (스마트 센서 기술을 이용한 구조물 건전도 모니터링 시스템 Part I : 스마트 센서의 개발과 성능평가)

  • Heo, Gwang Hee;Lee, Woo Sang;Kim, Man Goo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.2
    • /
    • pp.134-144
    • /
    • 2007
  • In this study, a smart sensor unit is developed by using the smart sensor technology that is being rapidly developed in recent years for structural health monitoring system, and its performance is evaluated through various experiments, and also, damage detection experiment is performed on a model structure. This paper as the first half of this study contains the development and performance evaluation of the smart sensor. In the latter half of this study, structure damage detection experiment is performed for the application of verified smart sensor unit into structural health monitoring, and it is compared with a wire measurement system. The smart sensor is developed by using high-power wireless modem, MEMS Sensor and AVR microcontroller, and an embedded program is also developed for the control and operation of the sensor unit. To verify the performance of the smart sensor, many experiments are performed for sensitivity and resolution analysis tests, data acquisition by using cantilever beam and shaker, and on-site application using actual bridge. As a result, the smart sensor proves to be satisfactory in its performance.

Tensile capacity of mortar-filled rectangular tube with various connection details

  • Kim, Chul-Goo;Kang, Su-Min;Eom, Tae-Sung;Baek, Jang-Woon
    • Steel and Composite Structures
    • /
    • v.44 no.3
    • /
    • pp.339-351
    • /
    • 2022
  • A mortar-filled rectangular hollow structural section (RHS) can increase a structural section property as well as a compressive buckling capacity of a RHS member. In this study, the tensile performance of newly developed mortar-filled RHS members was experimentally evaluated with various connection details. The major test parameters were the type of end connections, the thickness of cap plates and shear plates, the use of stud bolts, and penetrating bars. The test results showed that the welded T-end connection experienced a brittle weld fracture at the welded connection, whereas the tensile performance of the T-end connection was improved by additional stud bolts inserted into the mortar within the RHS tube. For the end connection using shear plates and penetrating stud bolts, ductile behavior of the RHS tube was achieved after yielding. The penetrating bars increased load carrying capacity of the RHS. Based on the analysis of the load transfer mechanism, the current design code and test results were compared to evaluate the tensile capacity of the RHS tube according to the connection details. Design considerations for the connections of the mortar-filled RHS tubes were also recommended.

Development of Low Pressure Axial Compressor Performance Test Rig (1단 저압 축류압축기 성능시험리그 개발)

  • Yang, Jae-Jun;Bang, Jeong-Suk;Rhee, Byung-Ho;Park, Tae-Choon;Kang, Young-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.977-980
    • /
    • 2011
  • In this paper, explain to development of low pressure axial compressor performance test rig in KARI. Performance test rig consist of a entrance section, rotor, stator, shaft, rig housing, bearing housing and exit section. Test rig design structural optimization to rotor dynamics analysis of the simplified rotor-shaft assembly and flow analysis of entrance/exit section.

  • PDF

Influence of Specimen Shapes on Tensile Behaviors of High Performance Fiber Reinforced Cement Composites (시험체 형상이 고인성시멘트복합체 인장거동에 미치는 영향)

  • Yang Il-Seung;Yun Hyun-Do;Han Byung-Chan;Shin Hong-Chul;Park Wan-Shin;Kim Sun-Woo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05b
    • /
    • pp.65-68
    • /
    • 2005
  • Social requirements to the civil and building structures have been changed in accordance with the social and economic progress. It is very important to develop the innovative structural materials and tecnology that the social requirements appropriately. Ductility of High Performance Fiber Reinforced cementitious Composites (HPFRCC), which exhibit strain hardening and multiple crackling characteristics under the uniaxial tensile stress are drastically improved. Because ductility in tensile test are very different according to specimen shapes, three types of the direct tensile test are performed. The tensile test are performed using the tensile test specimen, dummbell-shaped specimen, and cylinder specimen. As a result, tensile performance in HPFRCC is very good comparing to cylinder specimen because of direction characteristics of fibers. It is necessary to clarify the examination method of suiting to the usage.

  • PDF

Effect of Fiber Hybridization on Durability Related Properties of Ultra-High Performance Concrete

  • Smarzewski, Piotr;Barnat-Hunek, Danuta
    • International Journal of Concrete Structures and Materials
    • /
    • v.11 no.2
    • /
    • pp.315-325
    • /
    • 2017
  • The purpose of the paper is to determine the influence of two widely used steel fibers and polypropylene fibers on the sulphate crystallization resistance, freeze-thaw resistance and surface wettability of ultra-high performance concrete (UHPC). Tests were carried out on cubes and cylinders of plain UHPC and fiber reinforced UHPC with varying contents ranging from 0.25 to 1% steel fibers and/or polypropylene fibers. Extensive data from the salt resistance test, frost resistance test, dynamic modulus of elasticity test before and after freezing-thawing, as well as the contact angle test were recorded and analyzed. Fiber hybridization relatively increased the resistance to salt crystallization and freeze-thaw resistance of UHPC in comparison with a single type of fiber in UHPC at the same fiber volume fraction. The experimental results indicate that hybrid fibers can significantly improve the adhesion properties and reduce the wettability of the UHPC surface.