• 제목/요약/키워드: structural feasibility

검색결과 700건 처리시간 0.025초

Force monitoring of Galfan cables in a long-span cable-truss string-support system based on the magnetic flux method

  • Yuxin Zhang;Xiang Tian;Juwei Xia;Hexin Zhang
    • Structural Monitoring and Maintenance
    • /
    • 제10권3호
    • /
    • pp.261-281
    • /
    • 2023
  • Magnetic flux sensors are commonly used in monitoring the cable force, but the application of the sensors in large diameter non-closed Galfan cables, as those adopted in Yueqing Gymnasium which is located in Yueqing City, Zhejiang Province, China and is the largest span hybrid space structure in the world, is seldom done in engineering. Based on the construction of Yueqing Gymnasium, this paper studies the cable tension monitoring using the magnetic flux method across two stages, namely, the pre-calibration stage before the cable leaves the rigging factory and the field tension formation stage of the cable system. In the pre-calibration stage in the cable factory, a series of 1:1 full-scale comparative tests were carried out to study the feasibility and relability of this kind of monitoring method, and the influence on the monitoring results of charging and discharging voltage, sensor location, cable diameter and fitting method were also studied. Some meaningful conclusions were obtained. On this basis, the real-time cable tension monitoring system of the structure based on the magnetic flux method is established. During the construction process, the monitoring results of the cables are in good agreement with the data of the on-site pressure gauge.The work of this paper will provide a useful reference for cable force monitoring in the construction process of long-span spatial structures.

A critical review of fluoride removal from water by using different types of adsorbents

  • Prashant S. Lingayat;Rampravesh K. Rai
    • Advances in environmental research
    • /
    • 제12권2호
    • /
    • pp.77-93
    • /
    • 2023
  • The water can be contaminated by natural sources or by industrial effluents. One such contaminant is fluoride. Fluoride contamination in the water environment due to natural and artificial activities has been recognized as one of the major problems worldwide. Among the commonly used treatment technologies applied for fluoride removal, the adsorption technique has been explored widely and offers a highly efficient simple and low-cost process for fluoride removal from water. This review paper the recent developments in fluoride removal from surface water by adsorption methods. Studies on fluoride removal from aqueous solutions using various carbon materials are reviewed. Various adsorbents with high fluoride removal capacity have been developed, however, there is still an urgent need to transfer the removal process to an industrial scale. Regeneration studies need to be performed to more extent to recover the adsorbent in field conditions, enhancing the economic feasibility of the process. Based on the review, technical strategies of the adsorption method including the Nano-surface effect, structural memory effect, anti-competitive adsorption and ionic sieve effect can be proposed. The design of adsorbents through these strategies can greatly improve the removal efficiency of fluoride in water and guide the development of new efficient methods for fluoride removal in the future. This paper describes brief discussions on various low-cost adsorbents used for the effective removal of fluoride from water.

PCR 과정의 오류 관리를 위한 Fault Tree Analysis 적용에 관한 시범적 연구 (Feasibility Study on the Fault Tree Analysis Approach for the Management of the Faults in Running PCR Analysis)

  • 임지수;박애리;이승주;홍광원
    • Applied Biological Chemistry
    • /
    • 제50권4호
    • /
    • pp.245-252
    • /
    • 2007
  • FTA(fault tree analysis)는 system 오류 관리를 위한 정성적/정량적 기법으로 적용되고 있다. FTA를 적용한 PCR의 오류 관리 system의 구축을 위한 시범적 단계로서 PCR 실행의 여러 단계 중 가장 간단한 단계인 '반응액의 제조 및 PCR 기기 사용 단계'를 모델로 하여 분석하였다. PCR 실행시 발생할 수 있는 오류를 연역적 논리 방식에 의해 fault tree의 형태로 규명하였다. Fault tree는 오류 관리의 최상위 요소인 top event를 중심으로 중간 계층을 이루는 intermediate events와 최하위의 요소인 basic events로 세분하여 구성하였다. Top event는 '반응액의 제조 및 PCR 기기 사용 단계에서의 오류'; 중간계층 events는 '기기 유래 오류', '실험행위 유래 오류'; basic events는 '정전상황', 'PCR 기기 선정', '기기 사용 관리', '기기 내구성', '조작의 오류', '시료 구분의 오류'로 분석되었다. 이로부터 top event의 원인 분석 및 중요 관리점을 도출하기 위하여 정성적/정량적 분석을 실시하였다. 정성적 기법으로 minimal cut sets, structural importance, common cause vulnerability를 분석하였고, 정량적 기법으로 simulation, cut set importance, item importance, sensitivity를 분석하였다. 정성적 분석과 정량적 분석의 결과에서 '시료 구분의 오류'와 '기기 조작의 오류'가 제 1중요관리점; '기기 관리의 오류'와 '내구성에 의한 오류'는 제 2중요관리점으로 일치되게 나타났다. 그러나 '정전상황'과 '기기 선정의 오류'는 정성적 분석에서만 중요관리점으로 분석되었다. 특히 sensitivity 분석에서 '기기 관리의 오류'는 사용 시간이 경과함에 따라 가장 중요한 관리점으로 부각되었다. 결론적으로 FTA는 PCR 모델 case에 대한 오류의 원인 분석 및 그 방지를 위한 중요관리점을 제시함에 따라, 궁극적으로 미래에 PCR의 오류 관리 system을 완성할 수 있는 효과적인 방법으로 사료된다.

피라미드 트러스 심재를 채용한 도시철도차량 출입문의 구조강성평가 (Structural Stiffness Analysis on Doors having Pyramidal Truss Cores in an Urban Transit Vehicle)

  • 임재용
    • 한국산학기술학회논문지
    • /
    • 제18권6호
    • /
    • pp.697-702
    • /
    • 2017
  • 본 연구에서는 현재 운행 중인 도시철도차량의 전동차 출입문에 규칙적 다공질 금속, 즉, 트러스 요소로 이루어진 피라미드 트러스 코어를 적용 가능한가에 대해 구조 강성 측면에서 검토하였다. 전동차 출입문은 내외피 사이 심재부에 허니콤과 보강재로 구성된 샌드위치 구조이며, 충분한 굽힘 강성과 내구성 등이 요구된다. 현재, 전동차 출입문의 기계적 성능은 한국철도표준규격(KRS)과 도시철도용품 품질규격에서 명시되고 있는데, 3점굽힘시험을 수행하여 중앙부의 처짐량을 측정하여 구조강성의 만족 여부를 판정하고 있다. 기존의 허니컴 코어를 채용한 출입문에 비해 피라미드 트러스 코어로 대체한 출입문의 구조강성 비교를 위하여 기존의 허니콤 코어와 동일한 무게의 두 종류의 피라미드 트러스 코어를 설계, 고려하였다. 이후 한국철도표준규격에 명시한 시험조건에 따라 유한요소해석을 실시하였다. 피라미드 트러스 코어를 적용한 전동차 출입문의 3점굽힘해석 결과 피라미드 트러스 심재 출입문은 기존의 허니콤 심재에 비해 약 2.5%의 처짐량이 더 발생하였지만, 규격에서 요구한 강성 조건을 충분히 만족시켰다. 따라서, 다기능성에 유리한 규칙적 다공질 금속인 피라미드 트러스 심재는 기존의 허니콤 기반의 출입문을 대체할 수 있을 것으로 판단된다.

포화도에 따른 다공성 매질의 유효열전도도 변화 예측 모델 (A New Structural Model for Predicting Effective Thermal Conductivity of Variably Saturated Porous Materials)

  • 차장환;구민호;김영석
    • 한국지구과학회지
    • /
    • 제32권6호
    • /
    • pp.629-639
    • /
    • 2011
  • 구조모델의 하나인 Maxwell-Eucken(ME) 모델을 이용하여 불포화 다공성 매질의 유효열전도도를 예측할 수 있는 새로운 모델을 제시하였다. 제시된 모델은 기질, 물 그리고 공기가 각각 연속상으로 존재하는 경우에 해당하는 3개 ME모델의 선형조합으로 표현되며, 매질 내에서 각 성분의 상대적 연속성 정도를 나타내는 '연속성계수'의 개념을 도입하여 선형방정식의 계수로 이용하였다. 기질의 연속성계수는 공극률과 선형의 관계를, 물과 공기의 연속성계수는 포화도와 선형 또는 비선형의 관계를 갖는 것으로 가정하였다. 공극구조가 알려진 3개 시료에 대한 열전달 모사 결과와 3개 시료의 열전도도 실험 결과를 이용하여 제시된 모델의 신뢰성을 평가하였다. 6개 시료에 대한 모델 예측값의 결정계수($R^2$)는 선형모델의 경우 0.86-0.98, 비선형모델의 경우 0.88-0.99로 나타나 모델의 예측 신뢰도가 매우 높은 것으로 분석되었다. 또한, 6개 시료에 대한 분석 결과를 이용하여 기질의 연속성계수와 공극률과의 관계식을 제시하였다. 따라서 본 예측모델은 기질의 열전도도, 공극률 및 포화도로부터 불포화 다공성 매질의 유효열전도도를 계산하는 데 이용될 수 있다.

표준육계사의 지붕을 활용한 태양에너지 설비 타당성 분석에 관한 기초 연구 (A Basic Study on Feasibility Analysis for Solar Energy Facility using Standard Broiler House Roof)

  • 김진현;정성진;김태욱;최준학;하유신
    • 한국태양에너지학회 논문집
    • /
    • 제34권4호
    • /
    • pp.57-65
    • /
    • 2014
  • In order to reduce greenhouse gas emissions in recent agricultural energy and increase the energy self-sufficiency rate of each farmer, it is extremely important to expand the supply of solar energy using unused space of agricultural facilities, roof. This study surveyed and analyzed the environmental and administrative factors such as problems according to the structure, azimuth and latitude of broiler houses and stability of standard broiler houses required to use broiler house roof based on the poultry houses in Sangju-si. The results can be summarized as follows: 55.6% of the solar energy facilities of according to the classification of arable lands of broiler houses were available, and 31.7% of them were available by classifying according to the azimuth. However, 20.6% of them were available in the survey considering all the arable land and azimuth. In the roof inclination of the broiler houses, from 20 to $25^{\circ}$ was the most common, 30 broiler houses. The broiler houses with the roof inclination more than $20^{\circ}$ accounted for 63% of the total. It was considered that the inclination was generally proper. In the structural safety, only 3 broiler houses that were constructed as a standard broiler house were available. In practice, all but one broiler house was inappropriate to expand the solar energy project using roof. The solar thermal facility weighed $63.6kg/m^2$ in total: the frame and solar thermal collector weighed $27.8kg/m^2$ and $35.8kg/m^2$, respectively. The standard broiler house required to be internally reinforced. This study suggested a plan for internal reinforcement and a feasible plan because there were problems with structural safety when installing solar thermal and photovoltaic systems.

철골 조립식주택 바닥판 진동 평가에 관한 연구 (A Study on Evaluation of Floor Vibration for Steel Frame Modular Housing)

  • 김종성;조민주;김승훈
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제20권1호
    • /
    • pp.104-111
    • /
    • 2016
  • 최근 연구개발이 활발히 이루어지고 있는 철골 조립식주택은 공장에서 생산되고 현장에서 조립되는 건설방식의 특성으로 인해 일반 건축물의 철근콘크리트 바닥판과 같이 일체타설 시공되지 못하게 되며 부재 단면크기 감소 및 경량화 등으로 인해 거주자의 활동에 의한 바닥판의 수직진동 및 처짐이 사용성 평가 측면에서 중요한 문제가 될 수 있다. 따라서 이 연구에서는 대상 조립식주택에서 장변방향 보 중앙에 샛기둥이 설치된 모듈과 설치되지 않은 모듈을 대상으로 실무에서 일반적으로 사용되고 있는 AISC 설계지침서 11의 계산식(이하 AISC 계산식)을 이용하여 바닥판의 진동성능을 평가하고 범용해석프로그램을 이용한 해석결과와 비교를 통해 AISC 계산식의 적용성을 고찰하였다. 이를 토대로 샛기둥이 설치된 모듈의 바닥판에서 AISC 계산식과 해석결과의 오차가 크게 발생되는 구조적 원인을 분석하고 이를 고려하는 방안을 제시하였다. 또한 대상 조립식주택 바닥판에 대한 진동성능 향상방안을 변수로 해석모델을 수립하고 진동응답해석 및 경제성평가를 통해 진동성능과 경제성이 우수한 방안을 제시하였다.

수중폭발에 의한 해중터널의 동적거동 (Dynamic Behavior of Submerged Floating Tunnel by Underwater Explosion)

  • 홍관영;이계희;이성로
    • 한국전산구조공학회논문집
    • /
    • 제31권5호
    • /
    • pp.215-226
    • /
    • 2018
  • 본 논문에서는 수중폭발(UE: underwater explosion)에 의한 해중터널(SFT: submerged floating tunnel)의 동적거동을 양해법(explicit)를 이용하는 LS-DYNA에 의한 유한요소해석을 통하여 분석하였다. SFT의 유한요소모델은 원형단면의 강재 라이너에 콘크리트가 채워진 복합재 원형단면으로 고려되었다. 해중터널 시스템의 중앙부 100m 구간은 탄소성재료를 고려한 솔리드(solid)요소로 상세하게 모델링하였으며, 양측 방향으로 각각 1km 구간에 대해서는 탄성재료를 고려하여 빔(beam) 요소로 이상화하여 모델링하였다. 사선계류시스템은 케이블(cable)요소를 적용하였으며, 수중폭발에 의한 동적거동시 수리동적질량의 영향을 고려하기 위하여 원형단면에 대한 추가질량을 고려하였다. 또한 부력과 같은 상시하중을 초기조건으로 고려하기 위하여 동적완화해석(dynamic relaxation analysis)를 수행하였다. UE는 부력비(B/W)와 폭발지점으로부터 거리의 변화에 대해서 고려하였으며, 폭발의 규모는 천안함 합동조사보고서(2010)를 참조하여 TNT 360kg로 결정하였다. 수중폭발 해석결과, 폭발지점으로부터 SFT까지 거리는 관입량, 충격압력의 크기와 반비례 관계에 있고, 부력비(B/W)가 커질수록 계류장력도 커짐을 확인하였다. 그러나 사선계류라인의 계류각 변화는 SFT의 수평거동, 관입량, 계류력, 충격압력과의 연관성을 찾을 수가 없었다.

의무기록사의 직무만족도 및 조직몰입도 (The Level of Job Satisfaction and Organizational Commitment of Medical Record Technicians)

  • 최은미;김영훈
    • 한국병원경영학회지
    • /
    • 제8권3호
    • /
    • pp.72-91
    • /
    • 2003
  • The purpose of this study is to investigate the recognition of health information managers, and to analyze the level of job satisfaction and organizational commitment of medical record technicians. The data for this study were collected through a self-administered survey with a structured questionnaire to 172 subjects from medical record technicians working in hospitals in Seoul and Gyeonggi Province as well as the faculty of medical schools across South Korea. In this analysis frequency, t-test, ANOVA, factor analysis and structural equation model were used. The main findings of this study are as follows: 1. As for recognition of the seven dimensions in the role of health information managers, the role as clinical data specialist received the most positive feedback, followed by document & repository managers, patient information coordinators, health information managers, data quality managers, security officers and research & decision support analyst. 2. The level of job satisfaction among medical information handlers and managers averaged 3.14. In terms of the factors in the work environment concerned with job satisfaction, being able to work independently and as team players reached the top among 6 factors with the average of 3.39, followed by professional position, salary & rewards, expectations for job performance and administration. 3. The average rate of organizational commitment stood at 3.09. Respondents tend to be focused on present tasks rather than future-oriented tasks. 4. The result of the analysis based on the relationship between recognition as health information managers, job satisfaction and organizational commitment found that all analysis are statistically meaningful. The more the respondents were aware of their roles as health information managers, the more they tended to be committed to their work and satisfied with their work. The more the respondents were committed to their work, the more satisfaction was seen. The effects of recognition as health information managers on organizational commitment measured 0.27 and for job satisfaction it was 0.17. The effects of organizational commitment on job satisfaction stood at 0.71. The feasibility of the model meets the standard at Chi-square value of 66.755 and the P value of 0.057. The Normed Fit Index (NFI) of 0.930 was in compliance with the standard for model feasibility and the squared multiple correlation coefficient of this model was 8% in organizational commitment and 60% in job satisfaction.

  • PDF

원자력급 흑연의 산화 정도에 따른 초음파특성 변화 및 초음파탐상의 타당성 연구 (Feasibility of Ultrasonic Inspection for Nuclear Grade Graphite)

  • 박재석;윤병식;장창희;이종포
    • 비파괴검사학회지
    • /
    • 제28권5호
    • /
    • pp.436-442
    • /
    • 2008
  • 최근 VHTR(very high temperature reactor)에 대한 연구에서 흑연이 노심내 구조재, 반사재, 감속재로서 가장 적절한 재료로 인식되고 있다. 운전온도는 약 $900^{\circ}C$로 원자로 내부에 유입되는 소량의 불순물에도 흑연은 산화되기 쉬우며 산화된 흑연은 공극률이 증가하며 구조재료로서 가져야 할 파괴인성이 낮아진다. 본 연구에서는 산화 전후의 흑연에 대하여 초음파특성을 측정하고, 이를 기반으로 흑연에 대한 초음파탐상검사의 유효성을 타진하였다. 흑연의 초음파특성 측정 결과 초음파속도는 탄소강의 약 1/2, 음파 감쇠는 5배 이상, 신호대잡음비는 약 1/3로 측정되었다. 산화 후, 초음파속도는 as-received 상태에 비하여 미소하게 감소되었으나 초음파감쇠는 200% 이상으로 그 차이가 두드러지게 나타났다. 신호대잡음비에 기반하여 POD (probability of detection)을 산출한 결과, 100 mm 미만의 깊이를 가지는 측면공(SDH; side drilled hole)는 산화 전후에 큰 차이를 나타내지 않으므로 해당 깊이를 가지는 결함에 대해서 초음파탐상검사는 비교적 신뢰성 있는 검사를 수행할 수 있다고 판단된다. 상용 자동초음파탐상 장비에서의 테스트 결과 80 mm이하의 깊이에서는 인적오류가 크지 않을 것으로 예상할 수 있었으며, 위상배열 초음파 기법을 통한 검사를 수행한 결과 역시 양호한 신호대잡음비로 측면공들을 모두 검출할 수 있었다.