• Title/Summary/Keyword: strip line

Search Result 385, Processing Time 0.037 seconds

The Effect of Oxide Layer Thickness to the Scale Defects Generation during Hot finish Rolling (열연사상 압연시 스케일 결함발생에 미치는 산화피막 두께의 영향)

  • 민경준
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1999.08a
    • /
    • pp.412-422
    • /
    • 1999
  • Scale defects generated on the strip surface in a tandem finishing mill line are collected from the strip trapped among the production mills by freezing the growing scale on the strip by the melt glass coating and shutting down the line simultaneously. The samples observed of its cross sectional figure showed the process of scale defect formation where the defects are formed at the base metal surface by thicker oxidized scale during each rolling passes. The properties of the oxidized layer growth both at rolling and inter-rolling are detected down sized rolling test simulating carefully the rolling condition of the production line. The thickness of the oxidized layer at each rolling pass are simulated numerically. The critical scale thickness to avoid the defect formation is determined through the expression of mutual relation between oxidized layer thickness and the lanks of the strip called quality for the scale defects. The scale growth of scale less than the critical thickness and also to keep the bulk temperature tuning the water flow rate and cooling time appropriately. Two units of Inerstand Cooler are designed and settled among the first three stands in the production line. Two units of scale defect is counted from the recoiled strip and the results showed distinct decrease of the defects comparing to the conventionaly rolled products.

  • PDF

Diagnosis of Coating Deviation in Continuous Galvanizing Line (연속용융아연 도금라인의 도금편차 진단)

  • 배용환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.26 no.2
    • /
    • pp.192-199
    • /
    • 2002
  • In continuous galvanizing process, the mass of zinc deposited and its distribution are controlled by the air pressure, effective distance from the air knife nozzle to the steel strip surface and line speed. Coating defects are resulted from the unbalance of these control factors and the inaccuracy of coating equipments. This paper investigates the main cause of coating deviation and a new air knife system for control of coating thickness was developed. We investigate dynamic pressure variation by air knife types. It is found that the coating deviation is caused by the unbalance of dynamic pressure, the irregularity of strip position, and the strip vibration. Formulating a useful coating model by using present working condition, an optimal working condition is suggested. The productivity and coating quality are improved by applying the result of this research at the shop floor.

Immunochromatographic Strip Assay for Detection of Cronobacter sakazakii in Pure Culture

  • Song, Xinjie;Shukla, Shruti;Lee, Gibaek;Kim, Myunghee
    • Journal of Microbiology and Biotechnology
    • /
    • v.26 no.11
    • /
    • pp.1855-1862
    • /
    • 2016
  • Cronobacter sakazakii (C. sakazakii) is a foodborne pathogen, posing a high risk of disease to infants and immunocompromised individuals. In order to develop a quick, easy, and sensitive assay for detecting C. sakazakii, a rabbit anti-C. sakazakii immunoglobulin G (IgG) was developed using sonicated cell protein from C. sakazakii. The developed anti-C. sakazakii (IgG) was of good quality and purity, as well as species-specific. The developed rabbit anti-C. sakazakii IgG was attached to the surface of a sulforhodamine B-encapsulated liposome to form an immunoliposome. A test strip was then prepared by coating goat anti-rabbit IgG onto the control line and rabbit anti-C. sakazakii IgG onto the test line, respectively, of a plastic-backed nitrocellulose membrane. A purple color signal both on the test line and the control line indicated the presence of C. sakazakii in the sample, whereas purple color only on the control line indicated the absence of C. sakazakii in the sample. This immunochromatographic strip assay could produce results in 15 min with a limit of detection of $10^7CFU/ml$ in C. sakazakii culture. The immunochromatographic strip assay also showed very good specificity without cross-reactivity with other tested Cronobacter species. Based on these results, the developed immunochromatographic strip assay is efficient for the detection of C. sakazakii and has high potential for on-site detection.

The development of On-line Model for the Prediction of Effective Strain Distribution by Non-dimensionalization on FEM Basis (유한요소법 기반의 무차원화를 이용한 판 유효 변형률 분포 예측 온라인 모델 개발)

  • Kim S. H.;Lee J. H.;Hwang S. M.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2004.08a
    • /
    • pp.359-367
    • /
    • 2004
  • In this research on-line model for the prediction of the effective strain distribution in strip on finishing mill process is presented. To describe the effective strain distribution in strip, three guide points and a distribution fitting variable are used. On-line models to get these points and fitting variable non-dimensionalization method and least square method were used with FEM simulation results. The model is developed using strip only FEM simulation as reference sets and compared with roll coupled FEM simulation results as perturbed sets. The on-line model to describe effective strain distribution shows good agreement with coupled FEM analysis results.

  • PDF

Strip temperature control for the heating furnace in the continuous-annealing line (냉연 연속 소둔로 가열대 판온제어)

  • 정호성;유석환;백기남
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1990.10a
    • /
    • pp.779-782
    • /
    • 1990
  • Recently batch type cold rolling processes have been replaced by continuous annealing type processes for cold rolled sheets of mild steel and high strength steel in order to obtain higher productivity, labor saving. In the continuous annealing line, it is very important to maintain the target steel strip temperature at the exit side of each furnace. The automation system of continuous annealing line is based on a hierachical composition. This paper shows how to preset the set value of furnace temperature control for the heating section in a continuous annealing line. Saying in other words, this paper presents the development of an adaptive control approach to control the exit strip temperature in the continuous annealing line. There are three parts in this approach; one is a process modelling and another is recursive parameter estimation and the other is a design of temperature controller.

  • PDF

Optimal Design and Experiment of One Chip Type SAW Duplexers using Micro_Strip Line Lumped Elements (마이크로 스트립라인 집중소자를 이용한 일체형 SAW 듀플렉서의 최적설계 및 실험)

  • 이승희;노용래
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.7
    • /
    • pp.647-655
    • /
    • 2003
  • Commonly used SAW duplexers have a difficulty on manufacture so that a transmission line is printed on the package or an LTCC multi-layer is needed because a quarter-wave transmission line which is a kind of an isolation network is applied to the SAW duplexers. In this study, new structures of one chip type SAW duplexers are proposed. In the proposed structure, Tx and Rx SAW ladder filters and isolation networks are located on a single 36LiTaO$_3$ piezoelectric substrate. The manufacture process is very simple than commonly used product. It is possible to improve tile performance by means of optimizing the micro-strip line lumped elements. It is easy to integrate and modulate with other surrounding components. The optimal design techniques can be applied to other kind of multi-port devices.

Integrated RT-PCR Microdevice with an Immunochromatographic Strip for Colorimetric Influenza H1N1 virus detection

  • Heo, Hyun Young;Kim, Yong Tae;Chen, Yuchao;Choi, Jong Young;Seo, Tae Seok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.273-273
    • /
    • 2013
  • Recently, Point-of-care (POC) testing microdevices enable to do the patient monitoring, drug screening, pathogen detection in the outside of hospital. Immunochromatographic strip (ICS) is one of the diagnostic technologies which are widely applied to POC detection. Relatively low cost, simplicity to use, easy interpretations of the diagnostic results and high stability under any circumstances are representative advantages of POC diagnosis. It would provide colorimetric results more conveniently, if the genetic analysis microsystem incorporates the ICS as a detector part. In this work, we develop a reverse transcriptase-polymerase chain reaction (RT-PCR) microfluidic device integrated with a ROSGENE strip for colorimetric influenza H1N1 virus detection. The integrated RT-PCR- ROSGENE device is consist of four functional units which are a pneumatic micropump for sample loading, 2 ${\mu}L$ volume RT-PCR chamber for target gene amplification, a resistance temperature detector (RTD) electrode for temperature control, and a ROSGENE strip for target gene detection. The device was fabricated by combining four layers: First wafer is for RTD microfabrication, the second wafer is for PCR chamber at the bottom and micropump channel on the top, the third is the monolithic PDMS, and the fourth is the manifold for micropump operation. The RT-PCR was performed with subtype specific forward and reverse primers which were labeled with Texas-red, serving as a fluorescent hapten. A biotin-dUTP was used to insert biotin moieties in the PCR amplicons, during the RT-PCR. The RT-PCR amplicons were loaded in the sample application area, and they were conjugated with Au NP-labeled hapten-antibody. The test band embedded with streptavidins captures the biotin labeled amplicons and we can see violet colorimetric signals if the target gene was amplified with the control line. The off-chip RT-PCR amplicons of the influenza H1N1 virus were analyzed with a ROSGENE strip in comparison with an agarose gel electrophoresis. The intensities of test line was proportional to the template quantity and the detection sensitivity of the strip was better than that of the agarose gel. The test band of the ROSGENE strip could be observed with only 10 copies of a RNA template by the naked eyes. For the on-chip RT-PCR-ROSGENE experiments, a RT-PCR cocktail was injected into the chamber from the inlet reservoir to the waste outlet by the micro-pump actuation. After filling without bubbles inside the chamber, a RT-PCR thermal cycling was executed for 2 hours with all the microvalves closed to isolate the PCR chamber. After thermal cycling, the RT-PCR product was delivered to the attached ROSGENE strip through the outlet reservoir. After dropping 40 ${\mu}L$ of an eluant buffer at the end of the strip, the violet test line was detected as a H1N1 virus indicator, while the negative experiment only revealed a control line and while the positive experiment a control and a test line was appeared.

  • PDF

Development of Displacement Measuring Sensor for Roll Eccentricity Contro1 at Hot Strip Mill (롤 편심제어를 위한 편심 측정장치 개발)

  • 전종학
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.167-167
    • /
    • 2000
  • This study aims at the development of REC sensor causing the gauge error in the hot strip rolling process, and the improvement of the hydraulic AGC (Automatic Gauge Control) system. The gauge error outbreaks from the various reasons, however, mainly the roll eccentricity is considered to cause a such kind of error. In the study, the REC (Roll Eccentricity Control System) sensor is designed using sensor An On - line test of the system shows the comprehensive effects of controlling the gauge error of the hot strip. On - Line test shows the possibility of enhancing the accuracy for gauge.

  • PDF

study on twist forming of elements for tube type line mixers (튜브형 line mixer용 element의 비틀음 성형에 대한 연구)

  • 김권희
    • Transactions of Materials Processing
    • /
    • v.5 no.2
    • /
    • pp.165-175
    • /
    • 1996
  • the process of strip twisting is practiced for the manufacture of some commercial parts such as elements for tube type line mixers. A thin metal strip with rectangular cross section is twisted thru an angle greater than 180。. Initial geometry is altered in to a complex one with dimen-sional changes. In practice several tryouts are necessary to obtain required dimensional accu-racies. A simple analysis model is proposed to predict the dimensional changes forming torque and axial force.

  • PDF

Analysis of Deformation and Residual Curvature of Steel Sheets in Strip Process Lines (박강판 제조공정에서의 소재 굽힘변형과 잔류만곡 발생 해석)

  • 박기철;전영우;정기조
    • Transactions of Materials Processing
    • /
    • v.6 no.2
    • /
    • pp.118-135
    • /
    • 1997
  • In order to analyze the deformation and residual curvature of steel sheets in the strip processing lines, a program for calculating curvature and work hardening of sheet was developed. Strip deformation caused by repeated bending under tension in the process lines was analyzed on the basis of the incremental-plasticity theory with the mixed hardenting model for the purpose of predicting the strip shape and the yield stress change. The developed calculation program was applied to predict curl and gutter of sheets within a 10% difference. The yield stress increment was also predicted with the similar accuracy. Application of the model to tension legvelling process showed that gutter could be controlled by intermesh and elongation. The yield stress increment in the electro-galvanizing line calculated by the developed program was found to be dependent on the yield strength, the applied tension and the diameter of the smallest roll.

  • PDF