• 제목/요약/키워드: stretcher

검색결과 57건 처리시간 0.022초

자동차용 소부경화형(BH) 강의 고주기 피로 특성에 미치는 미세 황화물의 영향 (Effect of Fine Copper Sulfides on the High Cycle Fatigue Properties of Bake Hardening Steels for Automotive)

  • 강성규;김진용;최일동;이승복;홍문희
    • 대한금속재료학회지
    • /
    • 제49권3호
    • /
    • pp.203-210
    • /
    • 2011
  • Bake hardening steels have to resist strain aging to prevent the yield strength increment and stretcher strain during press process and to enhance the bake hardenability during baking process after painting. The bake hardening steels need to control the solute carbon and the solute nitrogen to improve the bake hardenability. Ti and/or Nb alloying for nitride and carbide precipitation and low carbon content below 0.003% are used to solve strain aging and formability problem for automotive materials. However, in the present study, the effect of micro-precipitation of copper sulfide on the bake hardenability and fatigue properties of extremely low carbon steel has been investigated. The bake hardenability of Cu-alloyed bake hardening (Cu-BH) steel was slightly higher (5 MPa) than that of Nb-alloyed bake hardening (Nb-BH) steel, but the fatigue limit of Cu-BH steel was far higher (45 MPa) than that of Nb-BH steel. All samples showed the ductile fracture behavior and some samples revealed distinct fatigue stages, such as crack initiation, stable crack growth and unstable crack growth.

응급실 침대 위 흉부전후방향 엑스선 검사를 위한 상의고정장치 개발 (Development of the Upper Wear Fixation Device for Chest AP X-ray Imaging on the Emergency Stretcher Bed)

  • 임우택;홍동희
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권3호
    • /
    • pp.205-211
    • /
    • 2022
  • This study aimed to provide basic data for 3D printing in the medical health field by developing upper wear fixation device (UWFD), an auxiliary device for shortening chest AP examination time on emergency room beds and non-contact with patients. The standard of hooks was modeled according to the bed frame using the Autodesk Fusion 360. It was printed with Form2 (Formlabs, Somerville, MA, USA), as SLA (stereo lithography apparatus) method, and was washed and hardened using Form Wash and Form Cure. The completed UWFD conducted an online survey on 4 items of stability, convenience, availability, preference and general characteristics. The total stability average was 3.93±0.80, the total convenience average was 3.93±0.68, the total availability average was 4.01±0.89, and the total preference average was 3.80±1.08. This study was significant in suggesting improvements in the general X-ray examination process in the emergency room by designing and making aids to easily fixing the patient's top to the frame of the emergency bed while meeting promptness and non-contact with the patient.

이동 중 구급차에서 1급 응급구조사의 기관내 삽관 (Endotracheal Intubation of Paramedics in a Moving Ambulance)

  • 심규식
    • 한국산학기술학회논문지
    • /
    • 제13권11호
    • /
    • pp.5292-5298
    • /
    • 2012
  • 본 연구는 이동 중 구급차에서 응급구조사의 삽관자세 변화에 따른 시야의 높이 변화가 기관내 삽관의 신속성에 영향을 미치는지 비교하고 환자의 삽관자세 변화가 기관내 삽관의 신속성에 영향을 미치는지 분석하여 심정지 및 외상성 응급 환자에게 효과적인 전문기도관리를 시행하는데 목적이 있다. 연구대상은 C도 13개 소방서에 근무하고 있는 1급 응급구조사 60(대조군30명, 실험군30명)명을 편의추출하여 시행하였으며, 자료 분석은 SPSS WIN 14.0 Version을 사용하여 하였다. 연구결과 전문기도관리의 신속성 향상을 위해서는 환자의 냄새맡기 자세와 주들것과 응급구조사 시트 사이 공간에서의 기관내 삽관이 효과적일 것으로 사료되고 실험 후의 삽관 자신감이 유의하게 상승 하였으므로 전문기도관리의 효율성 향상을 위해서는 구급차 내에서의 삽관자세와 방법에 대한 지속적인 교육(훈련)이 필요할 것으로 사료된다.

CBRNE 재난 시 격리이송을 위한 장치 개발에 관한 탐색적 연구 (An exploratory study on the development of a device for isolation unit in CBRNE disaster)

  • Ham, Seung Hee;Park, Namkwun;Yoon, Myong O
    • 한국재난정보학회 논문집
    • /
    • 제14권1호
    • /
    • pp.65-71
    • /
    • 2018
  • 본 연구에서는 CBRNE 사고 및 공격에 의한 대규모 재난 발생 시 오염원 확산을 최대한으로 방지하면서 환자상태별 최적의 이송환경을 제공하기 위한 격리캡슐을 개발하는데 있어 필요한 성능적 기능적 요구사항을 고찰하고자 하였다. 이를 위하여 기존에 개발된 제품들의 특성을 파악함으로써 현장에서 즉각 활용을 어렵게 하는 곤란요소를 보완 수정할 수 있는 방안을 제시하였다. 연구결과, 현장에서 즉각 활용을 용이하게 하기 위한 격리이송장치를 개발하기 위해서 (1)기본기능, (2)효율적인 현장활용성, (3)격리이송장치 인터페이스 및 모듈간 결합방안의 각 고려요소에 대하여 제시하였다.

압전 소자형 광섬유 격자 소자를 이용한 파장 분할 다중화 시스템용 파장 가변형 광 분기/결합 장치 (Optical tunable wavelength add/drop multiplexer employing piezoactuated fiber Bragg gratings for WDM system)

  • 김세윤;이상배;최상삼;정준;정지채
    • 한국광학회지
    • /
    • 제8권4호
    • /
    • pp.340-344
    • /
    • 1997
  • 기존의 광섬유 격자 소자를 이용한 광 분기/결합 장치들이 광섬유 격자 소자의 브래그 파장에 해당하는 신호만을 선택할 수 있었던 단점을 극복하기 위해 압전 소자에 광섬유 격자 소자를 부착한 압전 소자형 광섬유 격자 소자를 제작하고, 이러한 압전소자형 광섬유 격자 소자와 편광 선속분할기를 이용하여 파장 분할 다중화 시스템용 파장 가변형 광 분기/결합 장치를 제안하고 실험하였다. 본 장치는 두 빛의 편광 상태를 이용하여 광섬유 격자 소자에 해당하는 파장의 신호를 분기/결합하는 장치로서 외부의 온도 변화에 크게 영향을 받지 않는 안정적인 특성을 보였다. 압전 소자에 전압을 인가함으로써 광섬유 격자 소자의 브래그 파장에 해당되는 신호(1549.3 nm)뿐만 아니라 가변된 파장(1550.1 nm)의 신호도 분기/결합할 수 있었다. 파장을 가변하지 않을 경우와 파장을 가변했을 경우 모두 광섬유 격자 소자에 의해 분기된 신호와 인접 채널 신호간의 차이 -26 dB 이하였으며 분기된 신호 중 광섬유 격자 소자를 통해 나오는 누설 신호는 -34 dB였다.

  • PDF

구급차 내부 디자인 개선에 관한 연구 (A study on improving the interior design of ambulance)

  • 신동민;박시은;박신혜
    • 한국응급구조학회지
    • /
    • 제17권3호
    • /
    • pp.9-20
    • /
    • 2013
  • Purpose: This research project addressed the need to designing more safe and efficient interior of the future ambulance in Korea. Methods: The study sample contained 760 paramedics in 4 districts. Data was collected by using a revised and complemented questionnaire based on literature review. Results: In relation to the efficacy and safety of work, answers related to storage closet showed to be the highest, and the most difficult part of paramedic work in an ambulance was lurching. CPR is the most frequently used emergency care inside an ambulance, but 66% of the paramedics responded that accurate CPR is not possible during vehicle transfer. Safety belts are not worn for 82.8% of the time, because of discomfort (51.3%). 13.8% of the paramedics responded that stretchers are unstable, 29.5% had an experience of having patients fall off the stretcher inside an ambulance. There were comments on installing equipments to prevent noise, and assist communication. Conclusion: The suggested practical layout contains five main modifications 1. Developing specially designed belt is needed for paramedic safety & efficient work. 2. The seats are molded to be ergonomically friendly. 3. Equipments to secure the body and safety devices for CPR are needed. 4. System improvement for communication between the driver seat and paramedics is needed. 5. The stretchers are molded to be maximize efficiency and minimize injury.

Crib Wall의 토압분포 (The Earth Pressure Distribution of Crib Wall)

  • 오세욱;권영철;배우석
    • 한국지반환경공학회 논문집
    • /
    • 제7권5호
    • /
    • pp.41-48
    • /
    • 2006
  • Crib wall은 헤더와 스트레처를 사용하여 옹벽의 골조를 축조하는 격자형 조립식 옹벽공법의 일종이다. 이 공법에서는 부재의 교차에 의해 생긴 격자 안에 자갈로 채움을 실시하여 옹벽의 중력을 유지하게 된다. 따라서 일반 옹벽에 비해 시공속도가 빠르며 경제적이다. 더불어, 옹벽의 배수 능력이 뛰어나며, 전면에 식생이 가능하다는 점을 들어 환경친화적인 장점도 강조되어 왔다. 그러나 Crib wall 시스템에서는 개별 부재 사이의 상대적인 움직임을 허용하며 채움재의 자중이나 외부하중에 의해 채움재에 응력 재분포가 발생한다. 이 때문에 콘크리트 옹벽과 같은 일체식 옹벽과는 토압의 분포에 있어 차이가 있다는 사실이 인식되어 왔다. 따라서 본 연구에서는 Crib wall의 토압특성을 관찰하기 위하여 축소된 모형을 이용한 재하시험을 실시하였다. 토압 특성은 6개의 특정한 높이에서 계측되었으며 이를 이용하여 위치별 토압의 분포 형태를 예측하였다. 시험결과는 기존의 이론식 및 일체식 옹벽과 비교되었으며 차이점에 대해 고찰하였다.

  • PDF

1급 응급구조사의 직무분석에 관한 연구 (A study on the job description of paramedics)

  • 손인아
    • 한국응급구조학회지
    • /
    • 제9권1호
    • /
    • pp.43-53
    • /
    • 2005
  • The purpose of this study was to survey a perception of frequency & importance level of job performance, from 249 paramedics who were working at fire station. The job related activities of 4 duties, 18 tasks and 145 task elements were checked by 4 rating scale. The data were analyzed using a SPSS program for descriptive statistics. The results of the study were as follows ; 1. Some of the most frequent tasks were medical tx, managing people & organization, trauma care, pt assessment, general coping skill 2. Some of the most frequent task elements were preparation of written reports, operation of pt lifting supplies, transportation of patients on stretchers, administration of cervical collar and utilization of scoop stretcher. 3. Some of the highest level of importance in task were resuscitation of circulation, surgical tx, safety & infection control, environmental emergency care, trauma care. 4. Some of the highest level of importance in task elements were administration of cervical collar, adult CPR, infant CPR, child CPR, and AED. 5. The highest level of task elements in perception of frequency & importance were administration of cervical collar, infection control after pt care, utilization of long back board, disinfection of ambulance after ride a long, care of chest pain pt, care of unconscious pt, tx of asthma. 6. A difference between frequent & importance score were due to lack of supplies(41%), structural problems(30%) and medical control system(16%), lack of skills(10%), Suggestion; 1. This paper would be more reliable and confirm through wilder range of survey. 2. It would be necessary of more depth survey through dacom study from paramedic. 3. Development of field oriented protocol & curriculum that based on task elements which have high score of both frequency & importance level is required.

  • PDF

영점검출을 이용한 광섬유형 전자 스페클 패턴 간섭계의 위상이동 (Phase-Shifting System Using Zero-Crossing Detection for use in Fiber-Optic ESPI)

  • 박형준;송민호;이준호
    • 한국광학회지
    • /
    • 제16권6호
    • /
    • pp.516-520
    • /
    • 2005
  • 본 논문에서는 광섬유형 전자 스페클 패턴 간섭계에 적용할 효과적인 위상이동 방법을 제안한다. 광섬유 마이켈슨 간섭계에 4$\pi$ 위상변조를 주기적으로 가하면서 각각 $\pi$의 위상차이를 갖는 4개의 영점위치를 검출하여 CCD 카메라의 이미지 취득신호를 생성한다. 이 신호에 따라 얻어지는 스페클 패턴은 위상추출 과정에 필요한 $\pi$/2 위상차이를 갖게 되며 후처리를 통하여 측정 대상체의 3차원적인 표면 위상정보를 얻게 된다. 환경적인 외란에 비하여 충분히 빠른 위상변조를 가할 경우 귀환제어 없이 빠르고 정확하게 $\pi$/2 위상 이동에 따른 CCD 동작신호를 생성할 수 있었으며, 위상변조기의 비선형적인 동작특성에 영향 받지 않는 실험결과를 얻을 수 있었다. 실험을 통하여 100 Hz의 영상 취득 속도를 얻었고, 25 Hz의 위상변조를 가할 때 출력 위상계단 신호의 오차는 0.6 mrad이었다.

Design of a Femtosecond Ti:sapphire Laser for Generation and Temporal Optimization of 0.5-PW Laser Pulses at a 0.1-Hz Repetition Rate

  • Sung, Jae-Hee;Yu, Tae-Jun;Lee, Seong-Ku;Jeong, Tae-Moon;Choi, Il-Woo;Ko, Do-Kyeong;Lee, Jong-Min
    • Journal of the Optical Society of Korea
    • /
    • 제13권1호
    • /
    • pp.53-59
    • /
    • 2009
  • A chirped-pulse amplification Ti:sapphire laser system has been designed using a 10-Hz 100-TW Ti:sapphire laser to generate 0.1-Hz 0.5-PW laser pulses and optimize their temporal qualities such as temporal contrast and pulse duration. A high-energy booster amplifier to be added is expected to produce an energy above 30 J through the parasitic lasing suppression and the efficient amplification. To improve the temporal contrast of the laser pulses, a high-contrast 1-kHz amplifier system is used as a front-end. A grating stretcher which makes the laser pulse have 1-ns duration is used to prevent optical damages due to high pulse energy during amplification. A grating compressor has been designed with group delay analysis to obtain the recompressed pulse duration close to the transform-limited pulse duration. The final laser pulses are expected to have energy above 20 J and duration below 40 fs.