• 제목/요약/키워드: strength efficiency factor

검색결과 109건 처리시간 0.019초

Effect of Relative Levels of Mineral Admixtures on Strength of Concrete with Ternary Cement Blend

  • Mala, Kanchan;Mullick, A.K.;Jain, K.K.;Singh, P.K.
    • International Journal of Concrete Structures and Materials
    • /
    • 제7권3호
    • /
    • pp.239-249
    • /
    • 2013
  • In the present scenario to fulfill the demands of sustainable construction, concrete made with multi-blended cement system of OPC and different mineral admixtures, is the judicious choice for the construction industry. Silica fume (SF) and fly ash (FA) are the most commonly used mineral admixtures in ternary blend cement systems. Synergy between the contributions of both on the mechanical properties of the concrete is an important factor. This study reports the effect of replacement of OPC by fly ash (20, 30, 40 and 50 % replacement of OPC) and/or silica fume (7 and 10 %) on the mechanical properties of concrete like compressive strength and split tensile strength, with three different w/b ratio of 0.3, 0.4 and 0.45. The results indicate that, as the total replacement level of OPC in concrete using ternary blend of OPC + FA + SF increases, the strength with respect to control mix increases up to certain replacement level and thereafter decreases. If the cement content of control mixes at each w/b ratio is kept constant, then as w/b ratio decreases, higher percentage of OPC can be replaced with FA + SF to get 28 days strength comparable to the control mix. A new method was proposed to find the efficiency factor of SF and FA individually in ternary blend cement system, based on principle of modified Bolomey's equation for predicting compressive strength of concrete using binary blend cement system. Efficiency factor for SF and FA were always higher in ternary blend cement system than their respective binary blend cement system. Split tensile strength of concrete using binary and ternary cement system were higher than OPC for a given compressive strength level.

Quantification of Bacterial Attachment-related Parameters in Porous Media

  • Park, Seong-Jik;Lee, Chang-Gu;Kim, Song-Bae
    • Environmental Engineering Research
    • /
    • 제13권3호
    • /
    • pp.141-146
    • /
    • 2008
  • Transport of Escherichia coli ATCC 11105 through porous media was investigated in this study using two sets of column experiments to quantify the attachment-related parameters (sticking efficiency, attachment rate coefficient and filter factor). The first set of experiments was performed in quartz sand under different ionic strength conditions (1, 20, 100, 200 mM) while the second experiments were carried out in quartz sand mixed with metal oxyhydroxide-coated sand (0, 5, 10, 25%). The breakthrough curves of bacteria were obtained by monitoring effluent, and then bacterial mass recovery and attachment-related parameters were quantified from these curves. The first experiments showed that the mass recoveries were in the range of 13.3 to 64.7%, decreasing with increasing ionic strength. In the second experiments, the mass recoveries were in the range of 15.0 to 43.4%, decreasing with increasing coated sand content. The analysis indicated that the sticking efficiency, attachment rate coefficient and filter factor increased with increasing ionic strength and coated sand content. The value of filter factor in the first experiments ranged from 1.45 e-2 to 6.72 e-2 1/cm while in the second experiments it ranged from 2.78 e-2 to 6.32 e-2 1/cm. Our filter factor values are one order of magnitude lower than those from other studies. This discrepancy can be attributed to the size of sand used in the experiment. The analysis demonstrated that the travel distance of bacteria estimated using the filter factor can be varied greatly depending on the solution chemistry and charge heterogeneity of porous media.

Efficiency factor of high calcium Class F fly ash in concrete

  • Sata, V.;Khammathit, P.;Chindaprasirt, P.
    • Computers and Concrete
    • /
    • 제8권5호
    • /
    • pp.583-595
    • /
    • 2011
  • This paper studied the cement efficiency factor (k factor) of high calcium Class F fly ash. This k factor represents a unit of fly ash with efficiency equivalent to k unit of cement. The high calcium Class F fly ash was used to replace cement in concrete. The modified Bolomey's law with linear relationship was used for the analysis of the result of compressive strength, cement to water ratio (c/w) and fly ash to water ratio (f/w) by using the multi-linear regression to determine the k factor and other constants in the equations. The results of analysis were compared with the results from other researcher and showed that the k factor of high calcium Class F fly ash depends on the fineness of fly ash, replacement level and curing age. While the amount of CaO content in Class F fly ash not evident. Furthermore, necessary criteria and variables for the determination of the k factor including the use of the k factor in concrete mix design containing fly ash were proposed.

중간부 부착파괴된 CFRP 판 보강 RC 보의 휨강도 평가 (Evaluation of Nominal Flexural Strength in RC Beams Strengthend with CFRP Plate and Failed by Intermediate Crack Debonding)

  • 홍성남;박종인;김태완;박선규
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제15권5호
    • /
    • pp.101-112
    • /
    • 2011
  • 본 논문은 중간부 부착파괴된 CFRP 보강 RC 보의 휨강도 산정을 다루고 있다. CFRP 보강 RC 보의 중간부 부착파괴의 영향을 고려하기 위해 강도감소계수를 제안하였다. 제안된 계수는 CFRP의 유효응력(또는 유효변형률)과 극한응력(또는 극한변형률)비로 정의 되는 유효변률 모델을 이용하여 실험데이터로부터 유도하였다. 휨강도 산정식은 강도감소계수를 변수로 하여 함수를 구성하였다. 제안된 강도감소계수의 유효성, 정확성 및 타당성을 입증하기 위해서 각국의 설계기준 및 연구자들에 의해 제안된 계수 값과 실험값을 본 연구결과와 비교 및 검증했다. 본 논문에서 제시하는 해석 결과는 제안된 강도감소계수가 중간부 부착파괴된 CFRP 보강 RC 보의 휨강도를 매우 효율적으로 평가할 수 있음을 나타낸다.

Elimination of the effect of strain gradient from concrete compressive strength test results

  • Tabsh, Sami W.
    • Computers and Concrete
    • /
    • 제3권6호
    • /
    • pp.375-388
    • /
    • 2006
  • Poor strength test results are sometimes not an indication of low concrete quality, but rather inferior testing quality. In a compression test, the strain distribution over the ends of the specimen is a critical factor for the test results. Non-uniform straining of a concrete specimen leads to locally different compressive stresses on the cross-section, and eventual premature breaking of the specimen. Its effect on a specimen can be quantified by comparing the compressive strength results of two specimens, one subjected to uniform strain and another to a specified strain gradient. This can be done with the help of a function that relates two parameters, the strain ratio and the test efficiency. Such a function depends on the concrete strength and cross-sectional shape of the specimen. In this study, theoretical relationships between the strain ratio and test efficiency are developed using a concrete stress-strain model. The results show that for the same strain ratio, the test efficiency is larger for normal strength concrete than for high strength concrete. Further, the effect of the strain gradient on the test result depends on the cross-sectional shape of the specimen. Implementation of the results is demonstrated with the aid of two examples.

Lyocell 섬유를 함유한 종이의 제조 및 적용에 관한 연구( I ) (A study on the application and manufacture of paper sheet containing lyocell fiber( I ))

  • 김종열;류운형;유성종;김정열;신창호;김영호
    • 한국연초학회지
    • /
    • 제22권1호
    • /
    • pp.99-106
    • /
    • 2000
  • In order to investigate the applicability of lyocell fiber to filter paper, papper sheets were manufactured with the addition of lyocell fibers in various length(1.5 denier: 2, 3, 4mm) and content(10, 30, 50%) and their physical characters, such as fibrilation rate, adsorption efficiency of methylene blue(MB), paper formation, and crimping ability, etc, were tested. The level of main fibrilation from lyocell fiber was higher in wet beating process than that in free beating because of the higher strength of lyocell fiber compared with wood fiber. Fibrilation could be observed at the degree of beating over 30$^{\circ}$ SR in wet beating with Valley beater. The air permeability and tear factor of the paper increased and the paper formation index decreased according to the increase of fiber length. The weak binding force of lyocell fiber in spite of its higher fiber strength, might be a limitng factor in addition of lyocell fiber to the natural wood pulp in manufacturing the paper having the needed physical properties. High contents of wood pulp decreased air permeability, the breaking length, tear factor, the bursting strength, and paper formation index in paper sheets. As the contents of lyocell increased from 10% to 100%, the adsorption efficiency of MB was elevated to 1.7-7.9 times compared with that in 100% wood pulp. But the length of lyocell fiber did not affect the MB adsorption.

  • PDF

슁글드 모듈에서 경화조건에 따른 ECA 접합강도와 효율의 상관관계에 관한 연구 (A Study on Correlation Peel Strength and the Efficiency of Shingled Modules According to Curing Condition of Electrically Conductive Adhesives)

  • 전다영;손형진;문지연;조성현;김성현
    • Current Photovoltaic Research
    • /
    • 제9권2호
    • /
    • pp.31-35
    • /
    • 2021
  • Shingled module shows high ratio active area per total area due to more efficient packing without inactive space between cells. The module is fabricated by connecting the pre-cut cells into the string using electrically conductive adhesives (ECA). ECAs are used for electric and structural connections to fabricate the shingled modules. In this work, we investigated a correlation between ECA peel strength and the efficiency of pre-cut 5 cells module which are fabricated according to ECA interconnection conditions. The curing conditions are varied to determine whether ECA interconnection properties can affect module properties. As a result of the peel test, the highest peel strength was 1.27 N/mm in the condition of 170℃, the lowest peel strength was 0.89 N/mm in the condition of 130℃. The efficiency was almost constant regardless of the curing conditions at an average of 20%. However, the standard deviation of the fill factor increased as the adhesive strength decreased.

전자기장을 활용한 초고층 건축물 콘크리트 압송기술개발 (Development of concrete pumping technology for construction of high-rise building using electromagnetic field)

  • 김우재;권승희
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 춘계 학술논문 발표대회
    • /
    • pp.4-5
    • /
    • 2018
  • Recently, high-strength concrete used for shortening the construction time of high-rise building construction, Concrete pumping technology is emerging as the core technology of high-rise buildings. In this paper, we have started to study the use of electromagnetic field as a method to increase the efficiency of the lubricating layer between the inside of the pipe and concrete, which has been established as the most important factor determining the pumping performance. The pumping performance improvement effect of concrete strength was verified and basic research was carried out to utilize it as a method to increase the efficiency of pumping in field application. In the related work, the effect of the electromagnetic field was verified by conducting a mock-up performance evaluation (horizontal 300 m) of the pumping force by the concrete strength.

  • PDF

Experimental and numerical study of effect of the fibers orientation of the different types of composite plates notched of U-shape repaired by composite patch

  • Berrahou Mohamed;Amari Khaoula;Belkaddour Leila;Serier Mohamed
    • Structural Engineering and Mechanics
    • /
    • 제88권3호
    • /
    • pp.201-208
    • /
    • 2023
  • In this work, the effect of the correction fibers direction on the efficiency of repairing damaged composite plates was highlighted. The composite plates studied in this work consist of eight layers of graphite/epoxy, while the patch used in this repair consists of four layers of the same type. The results obtained in this work, whether with regard to the experimental or analytical side, showed that the fibers orientation affects the repair efficiency, so the closer the angle of fibers inclination is to the tensile strength direction, the performance of the composite material is ideal. Hence, we conclude that the composite materials with longitudinal fibers (Parallel to tensile strength) is the most powerful and efficient material in performance.

Consideration of the Effect of Miscellaneous Factors on Frost Resistance of High Strength Concrete by Using the Factorial Design Method

  • 권영진
    • 콘크리트학회논문집
    • /
    • 제16권2호
    • /
    • pp.269-275
    • /
    • 2004
  • Factorial design method is applied to investigate the effects of various factors simultaneously rather than to conduct a series of single-factor experiment. As the results, frost resistance of the concrete specimens, in both W/C ratio of 0.28 and 0.35, was highly affected by the type of coarse aggregate that is, andesite produced more durable concrete than the limestone. Durability factor of the specimens, with W/C ratio of 0.28, which were demolded after I day and transferred to the curing room was higher than those demolded after 2 days. This stated the efficiency of the high early curing in high strength concrete.