• Title/Summary/Keyword: strength disaster

Search Result 389, Processing Time 0.028 seconds

A Study on the Method of Safety Condition Evaluation using Analytic Hierarchy Process (AHP를 이용한 기업별 안전평가 기법에 관한 연구)

  • Paik, Shinwon;Lee, Misun
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.55 no.3
    • /
    • pp.85-89
    • /
    • 2013
  • In the current domestic, many industrial accidents have happened. And these are analyzed according to several factors. But it is difficult that they evaluate their business safety. Thus, we conducted a study on business specific safety assessment techniques in order that business know their safety level and perform appropriative safety activities. Study methods are survey and AHP (Analytic Hierarchy Process). Each specific weighting factors to calculate the survey was conducted for safety and consulting experts (20 persons). Weight factor was used to AHP decision support as one of the ways through a number of alternatives to the ratings for the Minesota Multiphasic. Factors are each type of industry, specific industrial scale, disaster type and strength, worker age and tenure period, and region. First, survey was conducted with 20 professionals to estimate the weighting factors. Weights between factors using the AHP analysis tool based on the mean values were calculated. Second, last 3 years between the industrial accidents statistics were used to calculate the weights for each of the rating factors in the Occupational Safety and Health Agency. Grade weights between each factor which was based on the rating of each factor was calculated as the average of three years. Finally, the weights between each factor and the grade weights for each factor using the safety level of the enterprise were calculated so that you can evaluate the weighting.

A Plan to Ensure Safety of Electrical Installation in Empty Houses by Measuring Zero Phase Current (영상전류 측정을 이용한 부재수용가의 전기설비에 대한 안전확보 방안)

  • Lim, Young-Bae;Bae, Seok-Myung;Kim, Young-Seok;Park, Chee-Huyn;Kim, Gi-Hyun;Cho, Sung-Won
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.55 no.4
    • /
    • pp.196-201
    • /
    • 2006
  • A electrical fault that may generate an electrical disaster is defined as any abnormal condition caused by reduction in the insulation strength. To find out the abnormal condition, periodical inspections have being performed every 3 years. Recently, the number of empty houses during normal working hours is rising by dramatic increase in the number of nuclear families and double income families. To define the potential risk of the electric installation, measurement of zero phase current has been being considered. But the measured value could not be adapted to an absolute reference to the installation because the measured zero phase current value also contained capacitive leakage current. Therefore, in this paper, the correlation between the condition of the electrical installation and the zero phase current was analyzed. The result focuses on to detect them in a cost efficient way.

An Experimental Study on the Stiffness Change of Scaffold Working Plate caused by Damage of Cross-beam (보재의 손상에 따른 비계용 작업발판의 강성 변화에 대한 실험적 연구)

  • Sung, Yong-won;Kang Min-guk;Won, Jeong-Hun
    • Journal of the Korean Society of Safety
    • /
    • v.36 no.5
    • /
    • pp.27-35
    • /
    • 2021
  • This study investigated the change in stiffness and deflection of a scaffold working plate caused by damage to a cross-beam in the plate. Experiments were conducted considering various load and damage conditions of cross-beams. A cross-beam falling off from the working plate was considered damaged. The load-displacement curves of specimens at the center of the uniform load showed that the working plate stiffness decreased by 14.66%-1.89%, depending on the load interval due to the damage of one cross-beam. A reduction in the stiffness of 33.94%-40.76% resulted from the damage of two cross-beams. Moreover, the displacement increased by an average of 25% when one cross-beam was damaged and an average of 65% when two cross-beams were damaged. Therefore, damage to the cross-beam in the working plate can potentially cause accidents and harm workers. As the load increases, the risk of an accident due to the aforementioned damage also increases because the stiffness remarkably decreases with the load increase. Further, the damage to the cross-beam mainly reduces the stiffness but increases the displacement rather than the strength of the working scaffold plate.

Experimental Study on the Combustion Characteristics of Magnesium using Infrared Thermography and FE-SEM (적외선 열화상법 및 FE-SEM을 활용한 마그네슘 연소특성에 관한 실험적 연구)

  • Lee, Jun-Sik;Nam, Ki-Hun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.6_2
    • /
    • pp.927-934
    • /
    • 2020
  • Magnesium powder has been widely used in various industries because it is light weight and extremely high mechanical strength including aeronautics and chemicals. However, magnesium, as a combustible metal, poses serious safety issues such as fires and explosions if it is not managed properly. Especially, magnesium's max adiabatic flame temperature is 3,340℃ and it is impossible to extinguish it by using water, CO2 and Halonagents. The aim of this study is to identify the combustion characteristics of magnesium powder. We carried out a combustion experiment, using 1 kg of magnesium (purity > 99 %, particle < 150 ㎛). The features of the magnesium burning process were scrutinized using infrared thermal image analysis. Also, a field-emission scanning electron microscope (FE-SEM) were used employed to analyze particulate composites and properties. It concludes the significant tendency of magnesium fire and light, combustion carbide's particle characteristics. This study contributes to make better prevention and response manners to magnesium fires, as well as fire investigation measures.

Physical Properties of Water Dispersion Polyurethane Resin Based on Ammonium Poly Phosphate and HMDI (폴리인산 암모늄과 HMDI 기반으로 제조된 수분산 폴리우레탄 수지의 물리적 특성 연구)

  • Lee, Joo-Youb
    • Journal of the Korean Applied Science and Technology
    • /
    • v.37 no.6
    • /
    • pp.1619-1626
    • /
    • 2020
  • In this study, the physical properties of water-dispersible polyurethane resins synthesized with polyammonium phosphate and HMDI were studied by coating film samples and full-grain surfaces. Solvent resistance was found to be unchanged in all samples, and in terms of tensile strength, DPU-AP3 (1.887 kgf/㎟) containing the most ammonium polyphosphate showed the lowest physical properties. The elongation rate was measured as 54 8% in the sample containing a large amount of ammonium polyphosphate. Abrasion resistance was measured as 548 mg.loss of a sample containing a lot of ammonium polyphosphate, and it was confirmed that the physical properties of the blended resin of ammonium polyphosphate and water-dispersible polyurethane were changed.

Insights from LDPM analysis on retaining wall failure

  • Gili Lifshitz Sherzer;Amichai Mitelman;Marina Grigorovitch
    • Computers and Concrete
    • /
    • v.33 no.5
    • /
    • pp.545-557
    • /
    • 2024
  • A real-case incident occurred where a 9-meter-high segment of a pre-fabricated concrete separation wall unexpectedly collapsed. This collapse was triggered by improperly depositing excavated soil against the wall's back, a condition for which the wall segments were not designed to withstand lateral earth pressure, leading to a flexural failure. The event's analysis, integrating technical data and observational insights, revealed that internal forces at the time of failure significantly exceeded the wall's capacity per standard design. The Lattice Discrete Particle Model (LDPM) further replicates the collapse mechanism. Our approach involved defining various parameter sets to replicate the concrete's mechanical response, consistent with the tested compressive strength. Subsequent stages included calibrating these parameters across different scales and conducting full-scale simulations. These simulations carried out with various parameter sets, were thoroughly analyzed to identify the most representative failure mechanism. We developed an equation from this analysis that quickly correlates the parameters to the wall's load-carry capacity, aligned with the simulation. Additionally, our study examined the wall's post-peak behavior, extending up to the point of collapse. This aspect of the analysis was essential for preventing failure, providing crucial time for intervention, and potentially averting a disaster. However, the reinforced concrete residual state is far from being fully understood. While it's impractical for engineers to depend on the residual state of structural elements during the design phase, comprehending this state is essential for effective response and mitigation strategies after initial failure occurs.

Experimental Study for Improving Method of Load Bearing and Spalling Prevention of 100 MPa High Strength Concrete Column (100 MPa급 고강도 콘크리트 기둥의 폭렬방지 및 하중지지력 향상방안에 관한 실험적 연구)

  • Cho, Bum-Yean;Kim, Heung-Youl;Kim, Hyung-Jun;Kwon, In-Kyu;Kim, Kyeong-Ok
    • Fire Science and Engineering
    • /
    • v.26 no.6
    • /
    • pp.78-84
    • /
    • 2012
  • In this study, we have conducted a fire resistance experiment under loading condition on standard fire to evaluate the fire resistance performance according to applying reinforcement of methods for reinforcing the lateral confinement of reinforced bars (Wire Rope) and fire resistance reinforcement (Fiber-Cocktail) for 100 MPa high strength concrete column. In the result of the experiment, in case of the test objects applied by hoop, it has been shown as not possible to be applied as the fire resistance structure after satisfying the fire resistance performance for 43 minutes. In case of applying the wire rope as lateral confinement of reinforced bar, instead of hoop in identical volume ratio, it has been shown as possible to apply it to the buildings with under 4 floors after satisfying the fire resistance performance fro 69 minutes with any separate fire resistance process. Also, in case of applying with mixing wire rope method, instead of hoop, and Fiber-Cocktail mix method to prevent spall, it has been shown as possible to apply to the buildings with over 12 floors after satisfying the fire resistance performance for 180 minutes.

An Experimental Study for Reinforcement Effect of Adhesive Stiffeners Depending on the Aspect Ratio of Masonry Wall (조적벽체의 형상비에 따른 접착형 보강재의 보강효과에 관한 실험적 연구)

  • Park, Byung-Tae;Kwon, Ki-Hyuk
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.4
    • /
    • pp.13-20
    • /
    • 2017
  • Unreinforced masonry buildings are vulnerable to lateral forces, such as earthquakes, owing to the nature of the building materials, yet numerous masonry buildings remain in South Korea. Since the majority of the existing masonry buildings were constructed more than 20 years ago, it is necessary to develop economical reinforcement methods for disaster reduction. In this study, external reinforcement of masonry walls using adhesive stiffeners was proposed as a reinforcement method for such age-old masonry buildings. Six specimens were fabricated with different aspect ratios (L/H = 1.0, 1.3, and 2.0) and used in static load tests to verify the reinforcement effect. The experimental results showed that the masonry walls before and after reinforcement were ruptured by rigid body rotation and slip. In addition, the maximum strength, maximum displacement, and dissipated energy of the walls were shown to increase after applying the adhesive stiffeners, thereby verifying the excellent reinforcement effect. Furthermore, an adhesive stiffener design for unreinforced masonry walls was proposed based on the increased shear strength achieved by using conventional glass fibers. The proposed design can be used as a basis for the application of adhesive stiffeners for unreinforced masonry walls.

Estimation on Filling Performance of Thixotropic Grout for Increasing Front-Water Depth of Gravity-Type Quay Wall (중력식 안벽 구조물의 증심 시공을 위한 가소성 그라우트의 충진성능 평가)

  • Jang, Kyong-Pil;Ryu, Yong-Sun;Kwon, Seung-Hee;Han, Woon-Woo;Oh, Myong-Hak
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.6
    • /
    • pp.169-177
    • /
    • 2017
  • Recently, as the size of transportation vessels has increased, there is a growing need for securing the front-water depths of existing port facilities. The method of deepening front-water depth is securing the depth of the port facility, and it is reinforced by grouting after excavating the rubble-mound to the required depth. The purpose of this study is to investigate the reinforcing performance and filling performance of thixotropic grout as a grouting material for reinforcing rubble-mound. Compressive strength tests were carried out for two types of thixotropic grout, and 5 specimens with a diameter of 400 mm and a height of 530 mm were manufactured and evaluated for filling performance. The required strength of reinforced rubble-mound required to ensure the safety of the structure is 6 MPa. All the thixotropic grouts used in this study were found to satisfy the required strength over 9 MPa at 7 days of age. As a result of visual observation of filling state of the filling performance test specimens, it was confirmed that the thixotropic grout was well filled up to the desired fillet height.

Safety Evaluation of Evacuation in a Dormitory Girls' High School based on PAPS (PAPS에 기반한 여자고등학교 기숙사생의 피난 안전성 평가)

  • Jeon, Seung-duk;Kong, Ha-sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.1
    • /
    • pp.469-481
    • /
    • 2022
  • This study is for increasing evacuation safety by analyzing RSET(the required safe escape time) through the arrangement of personnel by floor and by room while evacuating in a Girls' High School Dormitory. For this study, PAPS(Physical Activity Promotion System) results that have not been studied so far were analyzed and reflected in evacuation simulations on the premise that individual student's physical strength can affect evacuation. Based on the PAPS results, four scenarios were applied. In addition, evacuation simulation using the pathfinder program was conducted in two situations: the evacuation route was assigned or not. Scenario 4 was the fastest at 168.5 seconds of RSET in assigning evacuation routes among scenarios. As a result of this study, the arrangement of students focusing on improving their academic ability and student life guidance excluding student physical strength has problem. In order to solve this problem, it is effective to place C group students(low grade on PAPS) on low floors and A group students(high grade on PAPS) on high floors and to assign evacuation routes in each room. In the future, the following ways need to be more studied. A study on how to increase evacuation safety through practical evacuation training, the way of assessing evacuation safety reflecting the lifestyle and physical strength of girls, the evacuation route assignment according to the fire occurrence point, and the method to secure evacuation routes in the event of a fire near stairs or entrances should be conducted.