• 제목/요약/키워드: story model

검색결과 809건 처리시간 0.026초

국내 철골골조의 접합부모델에 따른 내진성능 비교 (Comparison of Seismic Performance of Steel Moment Frame according to Different Analytic Joint Models)

  • 이준석;한상환;이리형
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2000년도 봄 학술발표회논문집
    • /
    • pp.317-323
    • /
    • 2000
  • The purpose of this study is to compare the seismic resistant capacity inherent in ductile moment resisting frames using two different joint modeling. The difference between these two models is the capability for considering the panel zone deformation. For this purpose, 5 story steel moment frame is designed in compliance to the Korean seismic design provisions and the steel structure design standard. Nonlinear Static Procedure(NSP) and Nonlinear Dynamic Procedure(NDP) of this structure are carried out using two different joint models. Based on the results of NSP and NDP, the sensitivity of the response to analytical modeling is appraised. Also, it is proposed that for the highrise steel structures, the joint deformation should be accounted properly by the analytical model.

  • PDF

특수 중심가새골조의 연쇄붕괴 저항능력 평가 (Evaluation of Progressive Collapse Resisting Capacity of Special Concentrically Braced Frames)

  • 이영호;김진구;최현훈
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2008년도 정기 학술대회
    • /
    • pp.319-324
    • /
    • 2008
  • In this study the progressive collapse potential of special concentrically braced frames were investigated using the nonlinear static. All of seven different brace types were considered. According to the pushdown analysis results, most braced frames designed according to current design codes satisfied the design guidelines for progressive collapse initiated by loss of a first story mid-column; however most model structures showed brittle failure mode. This was caused by buckling of columns after compressive braces buckled. Among the braced frames considered, the inverted-V type braced frames showed superior ductile behavior during progressive collapse.

  • PDF

Nonlinear control of structure using neuro-predictive algorithm

  • Baghban, Amir;Karamodin, Abbas;Haji-Kazemi, Hasan
    • Smart Structures and Systems
    • /
    • 제16권6호
    • /
    • pp.1133-1145
    • /
    • 2015
  • A new neural network (NN) predictive controller (NNPC) algorithm has been developed and tested in the computer simulation of active control of a nonlinear structure. In the present method an NN is used as a predictor. This NN has been trained to predict the future response of the structure to determine the control forces. These control forces are calculated by minimizing the difference between the predicted and desired responses via a numerical minimization algorithm. Since the NNPC is very time consuming and not suitable for real-time control, it is then used to train an NN controller. To consider the effectiveness of the controller on probability of damage, fragility curves are generated. The approach is validated by using simulated response of a 3 story nonlinear benchmark building excited by several historical earthquake records. The simulation results are then compared with a linear quadratic Gaussian (LQG) active controller. The results indicate that the proposed algorithm is completely effective in relative displacement reduction.

준능동 MR 댐퍼가 설치된 건축 구조물의 분산제어 (Decentralized Control of Building Structures Installed with Semi-active MR Damper)

  • 윤경조;이상현;민경원;이성경
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.127-132
    • /
    • 2007
  • In this paper, to overcome local damages of structures, an uncertainty of structural model, installing sensors of structures, and economics of building system, decentralized semi-active magnetorheological(MR) damper using the displacement or velocity transferred to the response of floor installed damper is proposed. Relative magnitude between the control force of dampers and the story shear force is difined as design variables and the performance indices response spectra analysis through nonlinear time history analysis excited by seismic loads is performed according to this design variables. And the performance of this decentralized MR damper is compared with previous centralized LQR control algorithm using 3-stories benchmark building structure excited by El Centro (1940, N.S) in order to evaluate the application of building structures.

  • PDF

적층고무형 면진장치를 갖는 RC건물의 면진효과 검증 진동대 실험 (Shaking Table Tests of the 1/3 Scaled R/C Building with the Laminated Rubber Bearings)

  • 김동영;천영수;황기태;장극관
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.420-422
    • /
    • 2004
  • This paper reports the results of performance verification tests of the base isolated RC building with the laminated rubber bearings which is manufactured by Dongil Rubber Belt Co.. The shaking table tests were performed using a scaled 3-story model scaled to 1/3 of the prototype RC apartment building. Several major earthquake records were scaled to different peak ground accelerations and used as input base excitations. Through the verification tests, the validity of the applied base isolation device and the response reduction effect against earthquakes are confirmed.

  • PDF

태백 고생대 박물관 계획 (Tae-Baek Natural History Museum Project)

  • 이무상
    • 한국실내디자인학회:학술대회논문집
    • /
    • 한국실내디자인학회 2007년도 춘계학술대회 논문집
    • /
    • pp.75-76
    • /
    • 2007
  • Recently with increasing interest in the natural science history education, a lot of natural science museums have been developed in various locations. This project is located in one of the biggest Paleozoic site, Taebak Kangwon-do. This kind museum has had important rolls in terms of education for student, destination for traveling and reservation of important holdover of the old ages. To do those kind of parts, this project has been designed with concepts and themes like; i. being organized with story telling structure with theme "secret of life and earth from Taebak" ii. combining experiences between outdoor experimental search for the real fossils and indoor educational interactions with real size model and moving films. iii. designing with strong identities of Paleozoic era. For the design identities the outer appearance was designed with motive of trilbites in an abstract way and inside was finished with exposed concrete and various size of moving films projected to walls and floor to emphasize real scale experience of the old ages.

  • PDF

Structure's base design for earthquake protection numerical and experimental study

  • Alsaif, K.;Kaplan, H.
    • Structural Engineering and Mechanics
    • /
    • 제16권1호
    • /
    • pp.101-114
    • /
    • 2003
  • A base isolation system is proposed for earthquake protection of structures. The system incorporates spherical supports for the base, a specially designed spring-cam system to keep the base rigidly supported under normal condition and to allow it to move for the duration of the earthquake under the constraint of a spring with optimized non-linear characteristics. A single-story model is constructed to investigate the feasibility of the concept. Numerical simulations of the system as well as experimental results show that 95% reduction of the transmitted force to the structure can be achieved. To demonstrate the effectiveness of this isolation mechanism, the maximum dynamic bending stress developed at predetermined critical points within the frame of the structure is measured. Significant reduction of the dynamic stresses is obtained.

Enhanced least square complex frequency method for operational modal analysis of noisy data

  • Akrami, V.;Zamani, S. Majid
    • Earthquakes and Structures
    • /
    • 제15권3호
    • /
    • pp.263-273
    • /
    • 2018
  • Operational modal analysis is being widely used in aerospace, mechanical and civil engineering. Common research fields include optimal design and rehabilitation under dynamic loads, structural health monitoring, modification and control of dynamic response and analytical model updating. In many practical cases, influence of noise contamination in the recorded data makes it difficult to identify the modal parameters accurately. In this paper, an improved frequency domain method called Enhanced Least Square Complex Frequency (eLSCF) is developed to extract modal parameters from noisy recorded data. The proposed method makes the use of pre-defined approximate mode shape vectors to refine the cross-power spectral density matrix and extract fundamental frequency for the mode of interest. The efficiency of the proposed method is illustrated using an example five story shear frame loaded by random excitation and different noise signals.

점탄성-슬릿 복합댐퍼로 보강된 건물의 내진성능평가 (Seismic Performance Evaluation of Structures Retrofitted with Viscoelastic-Slit Hybrid Dampers)

  • 김민성;자오동쉬;김진구
    • 한국지진공학회논문집
    • /
    • 제22권7호
    • /
    • pp.361-367
    • /
    • 2018
  • This study investigates the seismic performance of a hybrid seismic energy dissipation device composed of a viscoelastic damper and a steel slit damper connected in parallel. A moment-framed structure is designed without seismic load and is retrofitted with the hybrid dampers. The model structure is transformed into an equivalent simplified system to find out optimum story-wise damper distribution pattern using genetic algorithm. The effectiveness of the hybrid damper is investigated by fragility analysis of the structure with and without the dampers. The analysis results show that after seismic retrofit the probability of reaching damage states, especially the complete damage state, of the structure turn out to be significantly reduced.

의료서비스조직의 조직개발 : 가상병원의 간호서비스혁신 사례 (Organization Development in Health Care Organizations: A Case Example of Nursing Service Development at Virtual Hospital)

  • 박헌준;강선주
    • 한국병원경영학회지
    • /
    • 제1권1호
    • /
    • pp.170-187
    • /
    • 1996
  • This paper proposes a change process model for organization development in health care organizations and provide an OD case exemplar of nursing service unit at Virtual Hospital. This case exemplar was written in a narrative form rather than in an argumentative form as an embodiment of organization development process as is viewed from the cultural/interpretive perspective rather than from the technical/rational one. This case exemplar illustrates the change process which consists of four interrelated components: change intervention, organizational target variables, individual organizational member, and organizational outcomes. It also demonstrates the applicability of the narrative rationality which involves narrative probability and narrative fidelity to the story where the learning organization, shared governance, and empowerment are fully emplotted and enlivened. The implications for organization development in health care organizations are discussed.

  • PDF