• 제목/요약/키워드: story construction

검색결과 480건 처리시간 0.036초

분임조활동의 대책수립 및 실시 방법에 관한 연구 (A Study on Construction Model of Planning and Establishment of Countermeasure in QCC Improve Activities)

  • 강원;강성수
    • 산업경영시스템학회지
    • /
    • 제33권1호
    • /
    • pp.51-58
    • /
    • 2010
  • In QCC improve activities QC story is useful for solving problems. Among those the planning and establishment of countermeasure step is most important in finding new alternatives and methods for problem solving. But that step is dealt with indifferent to problem solving occasionally, so it makes difficult to find those. In this paper we suggest an effective construction model of planning and establishment of countermeasure in QCC improve activities.

PC공법을 이용한 최적의 구조설계 (The Optimal Design of a PC System in HIBRAND)

  • 김종수;박형석;최동섭
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.298-301
    • /
    • 2006
  • The HIBRAND located in Yangjaedong, Seochogu, Seoul is a large complex shopping center of total space 48,000 p'yongs which consists of a nineteen-story business facility and a six-story sale facility. In the case of a big construction work in the downtown, they are suffered much difficulty by construction period and working space lack. They, however, can satisfy construction period, constructability and quality using a PC system in HIBRAND. Also, we maximized the advantage of each material being the abreast of a RC and steel structure method partially and devised a reasonable copula. A PC system with advantages of construction period, constructability and quality assurance should be actively practiced to big downtown construction work.

  • PDF

Behaviour of RC beam-column joint with varying location of construction joints in the column

  • Vanlalruata, Jonathan;Marthong, Comingstarful
    • Earthquakes and Structures
    • /
    • 제20권1호
    • /
    • pp.29-38
    • /
    • 2021
  • According to ACI 224.3R-95 (ACI, 2013), construction joints (cold joint) in the column are to be provided at the top of floor slab for column continuing to the next floor and underside of floor slab and beam. A recent study reveals that providing cold joint of the mentioned location significantly reduced the seismic performance of the frame structures. Since, the construction joints in multi-story frame structures normally provided at the top of the floor slabs and at soffit of the beam in the column. This study investigated the effect of construction joint at various location in the column of beam-column joint such as at the top of floor slab, soffit level of the beam, half the depth of beam below the soffit of the beam and at a full depth of the beam below the soffit of the beam. The study revealed that there is an improvement in seismic capacity of the specimens as the location of cold joint is placed away from the soffit of the beam for lower story column.

ANI Girder(앵글 및 래티스 철근으로 구성된 강조립보)와 HCS(Hollow Core Slab)를 활용한 지하주차장 (Underground Parking Lot by ANI Girder(ANgle Integrated Girder) and HCS)

  • 최익준;전병갑;염경수;최성모
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2016년도 춘계 학술논문 발표대회
    • /
    • pp.101-102
    • /
    • 2016
  • Through the story height reducing method, cost saving can be implemented in many aspects. Recently, as one of PC floor system, HCS(Hollow Core Slab) has been applied in many project, and it is proved that it is excellent in productivity, economic efficiency, and workability as well. We developed a new composite beam(ANI Girder) which can be associated with HCS and reinforced with a truss-shape rebar and angle. As a result of actual application on underground parking building with HCS, it is confirmed that this system is effective in workability and story height reducing.

  • PDF

창덕궁 성정각의 건축 시기와 건축 구조 (The Construction Period and the Structure of Seongjeonggak Hall, in Changdeokgung Palace)

  • 이종서
    • 건축역사연구
    • /
    • 제28권2호
    • /
    • pp.41-52
    • /
    • 2019
  • Seongjeonggak Hall in Changdeokgung Palace, although built after the Japanese Invasion in 1592, displays the architectural style and structure of Early Joseon period. It did not include ondol (Korean floor heating system) and contained Early Joseon style window frames. Later, King Jeongjo installed ondol as he repaired the building into a more convenient office. The initial construction of Seongjeonggak Hall was based on the architectural ideology of the Early Joseon Period, which divided up the space according to the season. Thus, the initial structure of the building consisted of a joint of a one-story building and a two-story building with the top floor of the latter specialized for hot and humid season. The two-story building was called 'chimnu(寢樓)', and its top floor was called 'nu-chimsil(樓寢室)'.

Application of three-dimensional modified inclined braces to control soft-story buildings

  • Nodehi, Soroush;Zahrai, Seyed Mehdi
    • Structural Engineering and Mechanics
    • /
    • 제83권6호
    • /
    • pp.811-824
    • /
    • 2022
  • Despite its disadvantages, soft story can reduce the damage to the upper floors by concentrating drift in that specific story provided that large drifts are avoided. Gapped-Inclined Brace (GIB) with reduced P-delta effects and the control of soft story stiffness makes it possible to take advantage of the soft story in buildings and increase their capacity for energy dissipation. OpenSees software is used in this study to validate and modify the GIB model's shortcomings. Also, the analysis method for this element is changed for design. The modified element is evaluated in 3D analysis. Finally, to retrofit an existing building, this element is used. Based on the Iranian seismic code, a six-story reinforced concrete building is modelled and studied with 3D analysis. In this building, the construction shortcomings and elimination of infills on the ground floor cause the formation of a soft story. Results of nonlinear static analysis, nonlinear dynamic, and incremental dynamic analysis using both components of seismic acceleration applied to the structure at different angles and the fragility curves indicate the improvement of the retrofitted structure's performance using the modified element to reach the required performance level following the retrofit code.

Winkler모델을 이용한 동바리의 시간의존적 축력 해석법 (Analysis of Time-dependent Axial Force of Shores using the Winkler Model)

  • 우창훈;김선영;이수곤
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.27-34
    • /
    • 2002
  • In the case of reinforced concrete structures, the knowledge of load transfer in the long-term behavior analysis considering construction sequence is very important. Even though long-term behavior of concrete structures has been widely studied, the studies on the time-dependent axial force variation of shore have been scarce to date. In order to investigate the shore behaviors under actual construction conditions, a three-story test frame was constructed on a construction site. The entire construction schedule for the test frame was made to follow the schedule of an actual three-story frame. To analyze the data collected from the test frame, an analysis method based on the Winkler foundation model was developed. This analysis method accurately Predicts the time-dependent behavior of shore. The analysis results coincide well with those obtained by the Midas GENw program

  • PDF

돔 구조물의 지진응답 저감을 위한 중간 면진장치의 적용 (Application of Mid-story Isolation System for Seismic Response Reducing of Dome Structure)

  • 김기철;김수근;강주원
    • 한국공간구조학회논문집
    • /
    • 제16권4호
    • /
    • pp.37-44
    • /
    • 2016
  • The seismic isolation system reduces the seismic vibration that is transmitted from foundation to upper structure. This seismic isolation system can be classified into base isolation and mid-story isolation by the installation location. In this study, the seismic behavior of dome structure with mid-story isolation is analyzed to verify the effect of seismic isolation. Mid-story isolation is more effective than base isolation to reduce the seismic responses of roof structure. Also, this isolation would be excellent in structural characteristics and construction.

Pushover Tests of 1:5 Scale 3-Story Reinforced Concrete Frames

  • Lee, Han-Seon;Woo, Sung-Woo;Heo, Yun-Sup;Seon, Jin-Gyu
    • KCI Concrete Journal
    • /
    • 제11권3호
    • /
    • pp.165-174
    • /
    • 1999
  • The objective of the research stated herein is to observe the elastic and inelastic behaviors and ultimate capacity of 1:5 scale 3-story reinforced concrete frame. Pushover tests were performed to 1:5 scale 3-story reinforced concrete frames with and without infilled masonry. To simulate the earthquake effect, the lateral force distribution was maintained by an inverted triang1e by using the whiffle tree. From the test results, the relation ships between the total lateral load and the roof drift, the distribution of column shears, the relation between story shear and story drift, and the angular rotations at the critical portions of structures were obtained. The effects of infilled masonry were investigated with regards to the stiffness, strength, and ductility of structures. Final collapse modes of structures with and without infilled masonry were compared.

  • PDF

단조하중을 받는 철골구조물의 접합부 연성도에 관한 연구 (A Study on Connection Ductility of Steel Structures Subjected to Monotonic Loading)

  • 강석봉;김진형
    • 한국강구조학회 논문집
    • /
    • 제12권4호통권47호
    • /
    • pp.375-385
    • /
    • 2000
  • 6층 비가새 및 20층 가새 철골구조물에서 기하 비선형, 재료 비선형, 접합부 비선형을 고려할 때 극한 횡하중에 대해 요구되는 접합부 연성도를 파악하였다. 재료 비선형을 고려하기 위하여 단면 모멘트-곡률 관계는 Fiber 모델을 이용하고 부재 강성행렬은 유연도 선형분포 해석모델을 이용하여 유도하였다. 강접합부를 반강접합부로 대체한 6층 구조물의 접합부 연성도는 강접합부인 경우 보다 적었고 20층 구조물에서 요구되는 반강접합부 연성도는 전단접합부의 경우와 거의 같고 강접합부는 전단접합부나 반강접합부에 비하여 큰 연성도가 필요하였다.

  • PDF