• 제목/요약/키워드: storage system

검색결과 6,942건 처리시간 0.034초

Prototype Design of Mass Distributed Storage System based on PC using Ceph for SMB

  • Cha, ByungRae;Kim, Yongil
    • 스마트미디어저널
    • /
    • 제4권3호
    • /
    • pp.62-67
    • /
    • 2015
  • The trend keywords in ICT sector will be Big Data, Internet of Things, and Cloud Computing. The rear end to support those techniques requires a large-capacity storage technology of low-cost. Therefore, we proposed the prototype of low-cost and mass distributed storage system based on PC using open-source Ceph FS for SMB.

An Internet Based Data Storage Protocol for ATA devices

  • Singh, Kulveer;Lim, Hyo-Taek
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2007년도 춘계학술발표대회
    • /
    • pp.1167-1170
    • /
    • 2007
  • This paper introduces a data storage transport protocol internet Advanced Technology Attachment (iATA) for ATA storage devices that can be accessed over (TCP/IP) networks. As the access speed of Advanced Technology Attachment (ATA) type storage is increasing, the importance of sharing the ATA type storages over internet is also increasing. We are proposing a protocol in which we have implemented the basic ATA command set to access the ATA type remote storage devices over the TCP/IP networks.In this paper, we give basic details of the protocol and discuss the existing storage protocols which are mainly used for accessing block storage like internet Small Computer System Interface (iSCSI) Hyper Small Computer System Interface (HyperSCSI) and ATA over Ethernet (AoE).

  • PDF

확률적 수요하에서의 자동창고의 필요 저장능력 추정 (Storage Capacity Estimation for Automated Storage/Retrieval Systems under Stochastic Demand)

  • 조면식
    • 대한산업공학회지
    • /
    • 제27권2호
    • /
    • pp.169-175
    • /
    • 2001
  • Most of studies on automated storage/retrieval (AS/R) system assumed that storage capacity is given, although it is a very important decision variable in the design phase. We propose a simple algorithm to estimate the required storage capacity, i.e., number of aisles and number of openings in vertical and horizontal directions in each aisle, of an AS/R system under stochastic demand, in which storage requests occur endogenously and exogenously while the retrieval requests occur endogenously from the machines. Two design criteria, maximum permissible overflow probability and maximum allowable storage/retrieval (S/R) machine utilization, are used to compute the storage capacity. This model can be effectively used in the design phase of new AS/R systems.

  • PDF

블록 단위 트랜잭션을 이용한 대용량 데이터의 실시간 저장관리기 (Real time Storage Manager to store very large datausing block transaction)

  • 백성하;이동욱;어상훈;정원일;김경배;오영환;배해영
    • 한국공간정보시스템학회 논문지
    • /
    • 제10권2호
    • /
    • pp.1-12
    • /
    • 2008
  • 초당 최소 5만 건에서 50만 건이 넘는 삽입트랜잭션이 발생하는 반도체 자동 생산 공정 시스템은 대량의 데이터를 실시간으로 저장하는 저장관리시스템을 필요로 한다. 대용량의 데이터를 빠르고 안정적으로 저장하기 위해서 많은 저장관리시스템이 연구되었다. 기존의 저장관리시스템은 대표적으로 전형적인 디스크 기반 DBMS가 있다. 그러나 디스크 기반 DBMS는 초당 50만 건의 삽입트랜잭션 처리는 매우 어렵다. 그래서 디스크 기반 DBMS의 성능을 향상시키기 위해 데이터를 디스크가 아닌 메인메모리를사용하는 메인메모리 DBMS가 등장하였다. 그러나 메인메모리 DBMS는 메인메모리 용량의 한계로 인해 대용량 데이터를 저장하는 것은 어렵다. 본 논문에서는 초당 5만 건 이상의 삽입트랜잭션을 지원하고 대용량 데이터를 저비용으로 저장하기 위해 블록단위의 삽입 트랜잭션을 사용한 저장관리시스템을 제안한다. 블록단위의 삽입 트랜잭션은 개별 튜플 단위의 로그기록 비용과 인덱스 생성비용을 블록단위로 변경시켜 비용을 크게 감소시킬 수 있다. 또한 제안시스템은 데이터를 압축 저장하여 저장 비용을 감소시킬 수 있다. 그러나 압축기법은 데이터의 필드정보가 유실되어 모든 데이터의 압축을 해제하는 비용이 발생한다. 이 문제를 해결하기 위해 제안시스템은 압축 시 압축되는 블록의 인덱스를 생성하여 데이터 검색 속도를 향상시켰다. 본 제안시스템은 반도체 공정에서 빠르게 발생하는 대용량 데이터를 고속으로 저장할 수 있고, 디스크 저 장비용을 감소시킬 수 있다.

  • PDF

과냉각 축냉시스템을 적용한 쇼케이스의 운전 특성에 대한 실험적 연구 (Experimental Study on The Running Characteristics of Showcase Using Cold Storage System)

  • 이동원;김정배
    • 한국태양에너지학회 논문집
    • /
    • 제32권6호
    • /
    • pp.22-28
    • /
    • 2012
  • The purpose of this study was to show how tomaintain high efficiency and to use reasonably when being applied the cold-heat storage systems to the showcase. An experimental study was performed to manufacture the showcase system in a laboratory. Comparing the result at general operation condition with that of the new condition using ice storage system, this study showed the effects of the refrigerant sub-cooling, and with using inverter. Using ice storage system, the ice making process was operated during midnight being not needed the cooling of the showcase through the continuous running of the condenser unit. And then, the refrigerant was sub-cooled using the stored cold-heat after being discharged from the air cooling condenser during the day time. Through the experiments, the load transfer rate for the showcase using inverter and ice storage was estimated about 30.0%. And showed that the total power consumption of the showcase with inverter could be reduced about 37% than that of the showcase without inverter.

누출 사고 완화를 위한 임시 저장 시설에 관한 연구 (A Study on the Temporary Storage Facility for Mitigating the Leakage Accident)

  • 송현오;이창준
    • 한국안전학회지
    • /
    • 제35권3호
    • /
    • pp.1-5
    • /
    • 2020
  • The leakage accident from a storage tank in an oil refinery plant occurred in April 2014 and the total loss is KRW 18 billion. This accident has prompted many companies to develop their own mitigation system to minimize the loss of the leakage accident. The aim of this study is to design the temporary storage facility system for dealing with leakage accidents. The basic concept of this system is that the leakage fluid of a hazardous material flows into a temporary storage tank and this is transferred to a spare tank by a pump as avoiding the overflow of a temporary storage tank. In order to design this system, the leakage velocity and quantity according to time series should be evaluated. In addition, a proper pump capacity should be determined to avoid repeating the pump switching on and off frequently. In this study, the benzene tank is selected to verify the efficacy of this system. This study can play a critical role to provide a guideline for designing a new system.

직류철도 회생에너지 저장시스템용 슈퍼커패시터 수명예측 (Predicting the Lifetime of Super-capacitor for DC Traction Regenerative Energy Storage System)

  • 김종윤;박찬흥;조기현;장수진;이병국;원충연
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 추계학술대회 논문집
    • /
    • pp.212-214
    • /
    • 2007
  • Regenerative energy which is generated during brake periods of DC traction might cause malfunction or destruction of rectifier or any other power conversion devices caused the increment of DC line voltage. Regenerative energy storage system using super-capacitor is one of the method to control the DC line voltage safely. And super-capacitor is very important device as energy storage device. Therefore, In this paper, we designed the regenerative energy storage system using super-capacitor and propose the method about predicting the lifetime of super-capacitor established in storage system. According to the this research, we can estimate the proper replacement moment for the existed super-capacitor due to the safety of the system. And improve the reliability of regenerative energy storage system using super-capacitor.

  • PDF

Zr-Ni계 지연관 결합체(K1) 저장수명 향상 (Storage Lifetime Improvement of Zr-Ni K1 Delay System)

  • 장일호;백승준;정은진;손영갑
    • 한국군사과학기술학회지
    • /
    • 제13권2호
    • /
    • pp.336-341
    • /
    • 2010
  • The burning interruption between the initiator and the delay column in a Zr-Ni K1 delay system used for a K510 fuze occurs with long-time storage. About 10 % failure probability of 15-years stored delay systems shows the failure mode in open literature. This paper shows storage lifetime improvement results for the delay system through changing the single-base delay column into double-base ones and controlling the manufacturing processes especially the initial inclusion of humidity. The double-base delay columns was implemented by inserting one delay column of fast burning rates between the initiator and the previous delay column of slow burning rates. Accelerated aging tests of the delay systems with double-base columns, and then the firing tests were performed to evaluate the improved lifetime. The double-base delay columns shows improved storage lifetime of the delay system through preventing the failure mode.

전기추진선박의 전력품질 개선을 위한 리튬-이온 배터리 에너지저장시스템 적용 (Lithium-ion Battery Energy Storage System for Power Quality Improvement in Electrical Propulsion Ships)

  • 구현근;서혜림;김장목
    • 전력전자학회논문지
    • /
    • 제20권4호
    • /
    • pp.351-355
    • /
    • 2015
  • This paper explained the application of a lithium-ion battery energy storage system to electric propulsion ships. The power distribution in electric propulsion ships has low power quality because of the variation in the power consumption of the propulsion motor. For proper operation of the ship, the power quality needs to be improved, and the battery energy storage system is used to solve power-quality problems. The simulation models of electric propulsion ship and battery energy storage systems are constructed on MATLAB/Simulink to verify the improvement in power quality. The proposed system is applied in various scenarios of the propulsion motor state. The power quality achieved by using the battery energy storage system in both voltage and frequency satisfies the standards set by IEC-60092/101.

열전달 특성이 향상된 마그네슘 수소화물을 이용한 수소저장시스템의 전산모사 (Numerical Simulation of Hydrogen Storage System using Magnesium Hydride Enhanced in its Heat Transfer)

  • 김상곤;심재혁;임연호
    • 한국수소및신에너지학회논문집
    • /
    • 제26권5호
    • /
    • pp.469-476
    • /
    • 2015
  • The purpose of this work is to investigate main factors to design a solid-state hydrogen stroage system with magnesium hydride with 10 wt% graphite using numerical simulation tools. The heat transfer characteristic of this material was measured in order to perform the highly reliable simulation for this system. Based on the measured effective thermal conductivity, a transient heat and mass transfer simulation revealed that the total performance of hydrogen storage system is prone to depend on heat and mass transfer behaviors of hydrogen storage medium instead of its inherent kinetic rate for hydrogen adsorption. Furthermore, we demonstrate that the thermodynamic aspect between equlibrium presssure and temperature is one of key factor to design the hydrogen storage system with high performance using magnesium hydride.