• Title/Summary/Keyword: storage level

Search Result 2,236, Processing Time 0.024 seconds

Can $CO_2$ concentration at one level of eddy covariance measurement be used to estimate storage term over forest\ulcorner

  • Choi, Tae-Jin;Chae, Nam-Yi;Kim, Joon;Lim, Jong-Hwan
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2003.11a
    • /
    • pp.47-50
    • /
    • 2003
  • $CO_2$ concentration profile was measured to investigate whether $CO_2$ concentration at one level (i.e., eddy covariance measurement level) can be used to estimate storage term without significant uncertainty at broadleaf deciduous forest at Kwangneung experiment forest in Korea. Based on t-test with significance level of 5%, there was no statistical difference between storage term from one-level $CO_2$ concentration and one from $CO_2$ profile measurement. Storage term constitutes on average 5% of half hourly net ecosystem exchange (NEE) even at unstable stability (i.e., well mixed condition), indicating that storage term should be considered even at daytime, which is sometimes neglected.

  • PDF

A Study on the Hydrologic Design of Detention Storage Ponds in Urbanized Area

  • Lee, Jung-Sik;Lee, Jae-Joon;Kim, Kyu-Ho
    • Korean Journal of Hydrosciences
    • /
    • v.7
    • /
    • pp.21-35
    • /
    • 1996
  • This Study is to develop the suitable hydrologic models for determination of the size and location of detention storage facilities to restrain stormwater runoff in urban areas. Hypothetical areas of two levels are considered to seize the hydrologic response characteristics. A one-square-kilometer ares is selected for the catchment level, and a 10-square-kilometer area consisting of 10 catchments is adapted at the watershed level as representative of urban drainage area. In this analysis, different rainfall freqyencies, land uses, drainage patte군, basin shates and detention storage policies are considered. Folw reduction effect of detention storage facilities is deduced from storage ratio and detention basin factor. A substantial saving in detention storage volumes is achieved 노두 the detention storage is planned at the watershed level rather than the catchment level. For the application of real watersheds, two watersheds in Seoul metropolitan area-Jamshil 2 and Seongnae 1-are selected on the basis of hydrologic response charactaristics. Through the regression analysis between dimensionless deterntion storage volume, dimensionless upstream area ratio and reduction rate of storage ratio, the regression equations to determine the size and location of detention storage faclities are presented.

  • PDF

Apple Quality as Affected by the Precooling Rate and $O_2$ Pulldown Rate in Controlled Atmosphere Storage

  • Mahajan, P.V.;Goswami, T.K.
    • Agricultural and Biosystems Engineering
    • /
    • v.3 no.1
    • /
    • pp.10-17
    • /
    • 2002
  • Quality attributes of apple are greatly affected by the cooling rate and environmental conditions during storage. Studies were conducted to evaluate the effect of cooling rate on different quality attributes of apple. The effect of $O_2$ pulldown rate of the CA chamber on the quality of apple was also determined. Two methods were used viz. conventional CA procedure and rapid CA procedure. Apples stored by medium and slow cooling methods lost its flesh firmness significantly from an initial level of 4.55 kg to 2.83 kg and 2.27 kg, respectively on 35 days after storage whereas, in rapid cooling, the firmness level changed from 4.55 kg to 3.20 kg on 35 days after storage. At the end of 35 days of storage, titratable acidity decreased insignificantly from an initial value of 0.24l% to 0.239% in the case of rapid CA whereas in the case of conventional CA it dropped significantly to 0.215% from its initial level. The initial flesh firmness of 4.55 kg also changed significantly to 4.05 kg on 35 days after storage in conventional CA whereas in rapid CA it changed to 4.36 kg, which was found to be non-significant at 5% level of significance. Total soluble solids increased from an initial level of $12.43^{\circ}$Bx to $12.60^{\circ}C.$ Bx on 35 days after storage in rapid CA whereas it increased to $13.07^{\circ}$ Bx in conventional CA. Ascorbic acid content of apple juice decreased insignificantly from 6.67 mg/100 mL to 5.87 mg/100 mL on 35 days after storage in rapid CA whereas in conventional CA, it decreased significantly to 5.27 mg/100 mL from its initial level.

  • PDF

12/16 Modulation Code for 4-Level Holographic Data Storage (4-레벨 홀로그래픽 데이터 저장장치를 위한 12/16 변조부호)

  • Jeong, Seongkwon;Lee, Jaejin
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.10
    • /
    • pp.10-14
    • /
    • 2016
  • Holographic data storage (HDS) features short access times, high storage capacities, and fast transfer rates since the data is recorded and read not by lines but by pages within a volume of holographic material. Furthermore, a single pixel can store more than 1 bit if it is multi-level. However, there is a problem of inter-symbol interference (ISI) between the adjacent symbols if the level difference between neighboring symbols is large. Hence, one should avoid side by side placement of the smallest level symbol and the largest level symbol in any direction. This paper proposes a 12/16 modulation code for 4-level holographic data storage, so that the largest symbol is 3 and the smallest symbol is 0, in order to reduce the ISI.

Performance Analysis of Parity Cache enabled RAID Level 5 for DDR Memory Storage Device (패리티 캐시를 이용한 DDR 메모리 저장 장치용 RAID 레벨 5의 성능 분석)

  • Gu, Bon-Gen;Kwak, Yun-Sik;Cheong, Seung-Kook;Hwang, Jung-Yeon
    • Journal of Advanced Navigation Technology
    • /
    • v.14 no.6
    • /
    • pp.916-927
    • /
    • 2010
  • In this paper, we analyze the performance of the parity cache enabled RAID level-5 via the simulation. This RAID system consists of the DDR memory-based storage devices. To do this, we develop the simulation model and suggest the basic performance analysis data which we want to get via the simulation. And we implement the simulator based on the simulation model and execute the simulator. From the result of the simulation, we expect that the parity cache enabled RAID level-5 configured by the DDR memory based storage devices has the positive effectiveness to the enhancing of the storage system performance if the storage access patterns of applications are tuned.

Design and Implementation of a Low-level Storage Manager for Efficient Storage and Retrieval of Multimedia Data in NOD Services (NoD서비스용 멀티미디어 데이터의 효율적인 저장 및 검색을 위한 하부저장 관리자의 설계 및 구현)

  • Jin, Ki-Sung;Jung, Jae-Wuk;Chang, Jae-Woo
    • The Transactions of the Korea Information Processing Society
    • /
    • v.7 no.4
    • /
    • pp.1033-1043
    • /
    • 2000
  • Recently as the user request on NoD (News-on-Demand) is largely increasing, there are a lot of researches to fulfill it. However, because of short life-cycle of new video data and periodical change of video data depending on anchor, it is difficult to apply the conventional video storage techniques to NOD applications directly. For this, we design and implement low-level storage manager for efficient storage and retrieval of multimedia data in NOD Services. Our low-level storage manager not only efficiently sotres video stream dat of new video itself, but also handles its index information. It provides an inverted file method for efficient text-based retrieval and an X-tree index structure for high-dimensional feature vectors. In addition, our low-level storage manager provides some application program interfaces (APIs) for storing video objects itself and index information extracted from hierarchial new video and some APIs for retrieving video objects easily by using cursors. Finally, we implement our low-level storage manager based on SHORE (Scalable Heterogeneous Object REpository) storage system by sunig a standard C++ language under UNIX operating system.

  • PDF

Study for Charge-Discharge Auto Level-Tuning Algorithm of Energy storage system (에너지저장시스템의 충, 방전 Auto Level-Tuning 알고리즘에 관한 연구)

  • Baek, Seoung-Gil;Lim, Ji-Young;Cha, Joon-Il;Kim, Kil-Dong;Kwon, Kyoung-Min
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.514-520
    • /
    • 2010
  • This paper is about control algorithms that bi-direction DC-DC Converter using Super Capacitor and regenerative power from DC feeding system in train. In order to take advantage of regenerative energy efficient, charge and discharge level value of energy storage system serve as an important factor. Respect to output fluctuations of the substation and catenary voltage changing, we offers Charge-Discharge Auto Level Tuning Algorithms to improve system following of Energy Storage System.

  • PDF

PMS : Prefetching Strategy for Multi-level Storage System (PMS : 다단계 저장장치를 고려한 효율적인 선반입 정책)

  • Lee, Kyu-Hyung;Lee, Hyo-Jeong;Noh, Sam-Hyuk
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.36 no.1
    • /
    • pp.26-32
    • /
    • 2009
  • The multi-level storage architecture has been widely adopted in servers and data centers. However, while prefetching has been shown as a crucial technique to exploit sequentiality in accesses common for such systems and hide the increasing relative cost of disk I/O, existing multi-level storage studies have focused mostly on cache replacement strategies. In this paper, we show that prefetching algorithms designed for single-level systems may have their limitations magnified when applied to multi-level systems. Overly conservative prefetching will not be able to effectively use the lower-level cache space, while overly aggressive prefetching will be compounded across levels and generate large amounts of wasted prefetch. We design and implement a hierarchy-aware lower-level prefetching strategy called PMS(Prefetching strategy for Multi-level Storage system) that applicable to any upper level prefetching algorithms. PMS does not require any application hints, a priori knowledge from the application or modification to the va interface. Instead, it monitors the upper-level access patterns as well as the lower-level cache status, and dynamically adjusts the aggressiveness of the lower-level prefetching activities. We evaluated the PMS through extensive simulation studies using a verified multi-level storage simulator, an accurate disk simulator, and access traces with different access patterns. Our results indicate that PMS dynamically controls aggressiveness of lower-level prefetching in reaction to multiple system and workload parameters, improving the overall system performance in all 32 test cases. Working with four well-known existing prefetching algorithms adopted in real systems, PMS obtains an improvement of up to 35% for the average request response time, with an average improvement of 16.56% over all cases.

The Storage Space Versus Expected Travel Time of Storage Assignment Rules in Automated Warehousing System

  • Ko, Chang-S.;Hwang, Hark
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.18 no.2
    • /
    • pp.23-29
    • /
    • 1992
  • To compute the expected travel time of storage and retrieval (S/R) machine in automated warehousing systems most of the previous studies assumed that equal number of rack openings are required regardless of the nature of storage assignment rules. It is known that randomized storage assignment rule usually needs less storage to space than needed for full turnover-based assignment rule. The objective of this paper is compute the expected travel time of each assignment rule more equitably by taking into account the storage space required for each rule. First, the rack storage space is determined which satisfies a given service level. Then based on the standard Economic Ordering Quantity model, trade-off analysis is carried out which relates the storage space to the expected travel time of the S/R machine. Finally, example problems are solved to compare the performance of each assignment rule under varying conditions of demand pattern and service level.

  • PDF

A Study on the Hydrologic Design of Detention Storage Ponds in Urbanized Area (도시유역에서 지체저류시설의 수문학적 설계에 관한 연구)

  • 이정식;이재준
    • Water for future
    • /
    • v.28 no.3
    • /
    • pp.159-173
    • /
    • 1995
  • This study is to develop the suitable hydrologic models for determination of the size and location of detention storage facilities to restrain stormwater runoff in urban areas. Fictitious areas of two levels are considered to seize the hydrologic response characteristics. A one-square-kilometer area is selected for the catchment level, and a 10-square-kilometer area consisting of 10 catchments is adapted at the watershed level as representative of urban drainage area. In this analysis, different rainfall frequencies, land uses, drainage patterns, basin shapes and detention storage policies are considered. Flow reduction effect of detention storage facilities is deduced from storage ratio and detention basin factor. A substantial saving in detention storage volumes is achieved when the detention storage is planned at the watershed level than the catchment level. For the application of real watersheds, two watersheds in Seoul metropolitan area-Jamshil 2, Seongnae 1-are selected on the basis of hydrologic response characteristics. Through the regression analysis between dimensionless detention storage volume, dimensionless upstream area ratio and reduction rate of storage ratio, the regression equations to determine the size and location of detention storage facilities are presented.

  • PDF