• Title/Summary/Keyword: storage facility

Search Result 616, Processing Time 0.024 seconds

A Design of N-Screen based Monitoring System for Marine-Facility (N-Screen 기반의 해양시설물용 모니터링 시스템 설계)

  • Kim, Ji-Yoon;Oh, Jin-Seok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.3
    • /
    • pp.613-622
    • /
    • 2015
  • The convergence of IT technology and marine facilities monitoring system is needed for effective monitoring systems to marine facilities. Especially the spread of smart device such as smart phone, smart pad, smart TV provide an environment that can check the status of the marine facility for marin facilities manager. However, smart phones and smart pads are used in a variety of OS used. Thus the monitoring system of the various service environments is difficult. In addition, There is inconvenience that must individually developed monitoring system for each device. In order to solve this problem NMMS (N-Screen Marine-facility Monitoring System) is proposed. NMMS is consist of Real-time monitoring system, Fault diagnosis system, Data storage system. To improve variety of smart devices accessibility, we use HTML 5. Through NMMS, marine facilities manager can use smart device such as PC, Notebook, smart phone, smart pad for marine facilities monitoring.

Study on Safety Management Plan through Chemical Accident Investigation in PCB Manufacturing Facility Etching Process (PCB 제조시설 에칭공정 화학사고 조사를 통한 안전관리 방안 연구)

  • Park, Choon-Hwa;Kim, Hyun-Sub;Jeon, Byeong-Han;Kim, Duk-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.4
    • /
    • pp.132-137
    • /
    • 2018
  • Although the number of chemical accidents has been declining since the Chemical Control Act of 2015, there have been repeated occurrences of similar types of accidents at printed circuit board (PCB) manufacturing facilities. These accidents were caused by the overflow of hydrochloric acid and hydrogen peroxide, which are toxic chemicals used in the printed circuit board manufacturing process. An analysis of the $Cl^-$ content to identify the cause of the accident showed that in the mixed route of hydrochloric acid and hydrogen peroxide, which are accidental substances, the $Cl^-$ concentration was 66.85 ppm in the hydrogen peroxide sample. Through reaction experiments, it was confirmed that the deformation of a PVC storage tank and generation of chlorine gas, which is a toxic gas, occurred due to reaction heat occurring up to $50.5^{\circ}C$. This paper proposes a facility safety management plan, including overcharge, overflow prevention, leak detection device, and separation tank design for mixing prevention in printed circuit board manufacturing facility etch process. To prevent the recurrence of accidents of the same type, the necessity of a periodic facility safety inspection and strengthening of the safety education of workers was discussed.

Assessment of Water and Pollutant Mass Balance by Soil Amendment on Infiltration Trench (침투도랑 토양치환의 물순환 및 비점오염물질저감 효과 평가)

  • Jeon, Minsu;Choi, Hyeseon;Kang, Heeman;Kim, Lee-hyung
    • Journal of Wetlands Research
    • /
    • v.22 no.2
    • /
    • pp.145-152
    • /
    • 2020
  • Highways are characterized by high non-point pollutant emissions due to high traffic volumes and sections that cause abrupt change in driving speed (i.e. rest stations, ticketing office, etc.). Most highways in Korea were constructed with layers that do not allow adequate infiltration. Moreover, non-point pollution reduction facilities were not commonly installed on domestic highways. This study was conducted to evaluate a facility treating highway runoff and develop a cost-effective design for infiltration facilities by using soil amendment techniques. Performing soil amendment increased the hydraulic retention time (HRT) and infiltration rate in the facility by approximately 30% and 20%, respectively. The facility's efficiency of removing non-point pollutants (Total Suspend Soiled (TSS), Chemical Oxygen Demand(COD), Biological Oxygen Demand(BOD), Total Nitrogen (TN) and Total Phosphorus, (TP) were also increased by 20%. Performing soil amendment on areas with low permeability can increase the infiltration rates by improving the storage volume capacity, HRT, and infiltration area. The application of infiltration facilities on areas with low permeability should comply with the guidelines presented in the Ministry of Environment's Standards for installation of non-point pollution reduction facilities. However, soil amendment may be necessary if the soil infiltration rate is less than 13 mm/hr.

Determination of Location and Depth for Groundwater Monitoring Wells Around Nuclear Facility (원자력이용시설 주변의 지하수 감시공의 위치와 심도 선정)

  • Park, Kyung-Woo;Kwon, Jang-Soon;Ji, Sung-Hoon
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.17 no.2
    • /
    • pp.245-261
    • /
    • 2019
  • Radioactive contaminant from a nuclear facility moves to the ecosystem by run-off or groundwater flow. Among the two mechanisms, contaminant plume through a river can be easily detected through a surface water monitoring system, but radioactive contaminant transport in groundwater is difficult to monitor because of lack of information on flow path. To understand the contaminant flow in groundwater, understanding of the geo-environment is needed. We suggest a method to decide on monitoring location and points around an imaginary nuclear facility by using the results of site characterization in the study area. To decide the location of a monitoring well, groundwater flow modeling around the study area was conducted. The results show that, taking account of groundwater flow direction, the monitoring well should be located at the downstream area. Also, monitoring sections in the monitoring well were selected, points at which groundwater moves fast through the flow path. The method suggested in the study will be widely used to detect potential groundwater contamination in the field of oil storage caverns, pollution by agricultural use, as well as nuclear use facilities including nuclear power plants.

Perception Survey Study on High-level Radioactive Waste: Targeting Local Residents in Gijang-gun, Busan (고준위방사성폐기물에 대한 인식 조사 연구: 부산 기장군 지역 주민을 대상으로)

  • Yeon-Hee Kang;Sung Hee Yang;Yong In Cho;Jung-Hoon Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.947-955
    • /
    • 2023
  • This study was conducted to investigate the awareness of spent nuclear fuel among residents in nuclear power plant areas and use it as basic data for establishing a disposal facility for high-level radioactive waste. 204 questionnaires collected online were analyzed using SPSS Window Ver 28.0. To verify differences between groups, t-test and one-way ANOVA were performed. And correlation analysis was conducted to confirm the relationship between variables. As a result, first, risk perception regarding nuclear-related accidents showed statistically significant differences depending on gender and educational level. The position on the construction of a permanent disposal facility for spent nuclear fuel showed a statistically significant difference depending on gender, education, and age, and the perception of the importance of each evaluation standard for establishing a spent nuclear fuel management plan showed a statistically significant difference depending on education and age. In terms of trust in information-providing institutions, trust in the National Assembly was found to be the lowest. Second, the results of the correlation analysis between variables showed that local residents are aware that an alternative to the current disposal of spent nuclear fuel is needed, and that financial support for the construction of a permanent disposal facility is needed. Therefore, in order to build a high-level radioactive waste disposal site, it is believed that it is necessary to increase trust in the government, collect opinions from local residents, and provide economic support.

A Study on the SEU in the SRAM to proton Irradiation

  • Lho, Young-Hwan;Park, Bo-Kyun;Kim, Bong-Sun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2295-2297
    • /
    • 2003
  • The major problem encountered in satellite design is EMI (Electro-Magnetic Interference) and EMC (Electro-Magnetic Compatibility). Here, our focus is on the effects of protons on the electronic system. The SEU (Single Event Upset) results from the level change of stored information due to photon radiation and temperature in the space and the nuclear power plant environment. The impact of SEU on PLD (Programmable Logic Devices) technology is most apparent in ROM/SRAM/DRAM devices wherein the state of storage cell can be upset. In this paper, a simple and powerful test techniques is suggested, and the results are presented for the analysis and future reference. The test results are compared with that of JPL test report. In our experiment, the proton radiation facility available at KIRAMS (Korea Institute of Radiological Medical Sciences) has been applied on a commercially available SRAM manufactured by Hynix Semiconductor Company.

  • PDF

Analysis of the Dietitian's Job description in the school (영양사 직무기술서 (2000년) 의 영양사 직무영역별 특성 분석 3 : 학교)

  • Mun, Hyeon-Gyeong;Jang, Yeong-Ju
    • Journal of the Korean Dietetic Association
    • /
    • v.8 no.2
    • /
    • pp.143-153
    • /
    • 2002
  • The purpose of this study was to verify the dietitian’s job description(2000) for dietitians working at schools. The survey was carried out for the frequency, criticality and difficulty of each job description with 4 point scales. The number of subject was 125 dietitians, who have been working over 3 years at their position. The results are following ; 1. Duties with high frequency and criticality were menu managements, purchasing, storage and inventory controls, food productions, meal services, managing equipments and facility, waste managements, sanitation managements and self promotions. 2. Duties with middle frequency and high criticality were human resources managements and financial managements. 3. Duties with low frequency and high criticality were nutrition assessment (life cycles, certain diseases, specific condition), medical nutritional theraphy, nutrition education and public health nutrition. 4. For difficulty, duties related food service had lower points than that of nutrition service.

  • PDF

Analysis of the Dietitian's Job description in the business and industry foodservice (영양사 직무기술서 (2000 년) 의 영양사 직무영역별 특성 분석 I : 사업체)

  • Mun, Hyeon-Gyeong;Jang, Yeong-Ju
    • Journal of the Korean Dietetic Association
    • /
    • v.8 no.2
    • /
    • pp.121-131
    • /
    • 2002
  • The purpose of this study was to verify the dietitian’s job description(2000) for dietitians working at business and industry foodservice. The survey was carried out for the frequency, criticality and difficulty of each job description with 4 point. The number of subject was 39 dietitians, who have been working over 3 years at their position. The results are following ; 1. Duties with high frequency and criticality were menu managements, purchasing, storage and inventory controls, food productions, meal services, waste managements and sanitation managements. 2. Duties with middle frequency and high criticality were managing equipments and facility, human resources managements, financial managements, self promotions. 3. Duties with low frequency and high criticality were nutrition assessment (life cycles, certain diseases, specific conditions), medical nutritional theraphy, nutrition education and public health nutrition. 4. For difficulty, duties related food service had lower points than that of nutrition service.

  • PDF

Analysis of the Dietitian's Job description in the hospital (영양사 직무기술서 (2000년) 의 영양사 직무영역별 특성 분석 2 : 병원)

  • Mun, Hyeon-Gyeong;Jang, Yeong-Ju
    • Journal of the Korean Dietetic Association
    • /
    • v.8 no.2
    • /
    • pp.132-142
    • /
    • 2002
  • The purpose of this study was to verify the dietitian’s job description(2000) for dietitians working at hospitals. The survey was carried out for the frequency, criticality and difficulty of each job description with 4 point scales. The subject was 62 dietitians, who have been working over 3 years at their position. The results are following ; 1. Duties with high frequency and criticality were menu managements, food productions, meal services and self promotions. 2. Duties with middle frequency and high criticality in food service area were purchasing, storage and inventory controls, waste managements, sanitation managements, managing equipments and facility, human resources managements and financial managements. 3. Duties with middle frequency and high criticality in nutrition service area were nutrition assessment (life cycles, certain diseases, specific condition), medical nutritional theraphy and nutrition education. 4. For difficulty, duties related nutrition service had higher points than that of food service.

  • PDF

Biofiltration Technology Application for Livestock and Compost Facility Odor Control (축사와 퇴비 시설 취기제어를 위한 생물학적 탈취 기술의 적용)

  • 홍지형
    • Journal of Animal Environmental Science
    • /
    • v.6 no.3
    • /
    • pp.153-160
    • /
    • 2000
  • Odor control for livestock and compost facilities has focused on manure handling and treatment during storage and land application, however, large amount of malodorous air is emitted and it is one of main sources of malodour in livestock farming. Biological treatment or biodegradation involves converting an organic contaminant to carbon dioxide and water using natural bacteria. Biofiltration is an effective air pollution control technology that uses microorganisms to breakdown gaseous contaminants and produce innocuous end products. Investment and operating costs on the biofiltration are lower than for thermal and chemical oxidation processes. This paper is intended to provide an overview of basic design and operating criteria for biofilters to control odors from livestock and compost facilities.

  • PDF