• Title/Summary/Keyword: stock abutment

Search Result 6, Processing Time 0.021 seconds

Influence of the implant abutment types and the dynamic loading on initial screw loosening

  • Kim, Eun-Sook;Shin, Soo-Yeon
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.1
    • /
    • pp.21-28
    • /
    • 2013
  • PURPOSE. This study examined the effects of the abutment types and dynamic loading on the stability of implant prostheses with three types of implant abutments prepared using different fabrication methods by measuring removal torque both before and after dynamic loading. MATERIALS AND METHODS. Three groups of abutments were produced using different types of fabrication methods; stock abutment, gold cast abutment, and CAD/CAM custom abutment. A customized jig was fabricated to apply the load at $30^{\circ}$ to the long axis. The implant fixtures were fixed to the jig, and connected to the abutments with a 30 Ncm tightening torque. A sine curved dynamic load was applied for $10^5$ cycles between 25 and 250 N at 14 Hz. Removal torque before loading and after loading were evaluated. The SPSS was used for statistical analysis of the results. A Kruskal-Wallis test was performed to compare screw loosening between the abutment systems. A Wilcoxon signed-rank test was performed to compare screw loosening between before and after loading in each group (${\alpha}$=0.05). RESULTS. Removal torque value before loading and after loading was the highest in stock abutment, which was then followed by gold cast abutment and CAD/CAM custom abutment, but there were no significant differences. CONCLUSION. The abutment types did not have a significant influence on short term screw loosening. On the other hand, after $10^5$ cycles dynamic loading, CAD/CAM custom abutment affected the initial screw loosening, but stock abutment and gold cast abutment did not.

Fabrication of custom abutment using dental CAD/CAM system (임상가를 위한 특집 2 - CAD/CAM 시스템을 이용한 Custom abutment의 제작)

  • Kim, Hyeong-Seob
    • The Journal of the Korean dental association
    • /
    • v.50 no.3
    • /
    • pp.118-125
    • /
    • 2012
  • CAD/CAM systems (computer-aided design / computer-aided manufacturing) used for decades in restorative dentistry have its application to implant dentistry. This study aimed to overview CAD/CAM systems used implant dentistry, especially emphasizing custom implant abutments manufacturing. CAD/CAM custom abutments present the advantages of being specific to each patient and providing a better fit than the stock and cast custom abutments. This cutting edge technology of virtual-designed and computer-milled implant abutments will likely replace traditional implant restorative protocols and become the standard for implant dentistry in the foreseeable future.

Accuracy of a separating foil impression using a novel polyolefin foil compared to a custom tray and a stock tray technique

  • Pastoret, Marie-Helene;Krastl, Gabriel;Buhler, Julia;Weiger, Roland;Zitzmann, Nicola Ursula
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.4
    • /
    • pp.287-293
    • /
    • 2017
  • PURPOSE. To compare the dimensional accuracy of three impression techniques- a separating foil impression, a custom tray impression, and a stock tray impression. MATERIALS AND METHODS. A machined mandibular complete-arch metal model with special modifications served as a master cast. Three different impression techniques (n = 6 in each group) were performed with addition-cured silicon materials: i) putty-wash technique with a prefabricated metal tray (MET) using putty and regular body, ii) single-phase impression with custom tray (CUS) using regular body material, and iii) two-stage technique with stock metal tray (SEP) using putty with a separating foil and regular body material. All impressions were poured with epoxy resin. Six different distances (four intra-abutment and two inter-abutment distances) were gauged on the metal master model and on the casts with a microscope in combination with calibrated measuring software. The differences of the evaluated distances between the reference and the three test groups were calculated and expressed as mean (${\pm}SD$). Additionally, the 95% confidence intervals were calculated and significant differences between the experimental groups were assumed when confidence intervals did not overlap. RESULTS. Dimensional changes compared to reference values varied between -74.01 and $32.57{\mu}m$ (MET), -78.86 and 30.84 (CUS), and between -92.20 and 30.98 (SEP). For the intra-abutment distances, no significant differences among the experimental groups were detected. CUS showed a significantly higher dimensional accuracy for the inter-abutment distances with -0.02 and -0.08 percentage deviation compared to MET and SEP. CONCLUSION. The separation foil technique is a simple alternative to the custom tray technique for single tooth restorations, while limitations may exist for extended restorations with multiple abutment teeth.

A STUDY ON THE FIT OF IMPLANT-RETAINED PROSTHESES USING ELECTRIC DISCHARGE MACHINING (전기방전가공법을 이용한 임플랜트 보철물의 적합도 연구)

  • Han Eu-Taek;Kim Yung-Soo;Kim Chang-Whe;Yang Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.1
    • /
    • pp.1-13
    • /
    • 2001
  • An absolutely passive fit at the interface with the superstructure and the abutment cylinders is need for implant longevity. In this study, a method of cast framework correction using spark erosion technology was evaluated. Electric discharge machining(EDM) is a process that uses electrical discharges, or sparks, to machine metal, The surface being machined is bombared with high-intensity electrical energy pulses that gradually melt away the stock until the desired configuration is obtained. Master model was fabricated by using metal block impression analogue, which fired 5 Branemark squared impression coping in an arc shaped metal block. Then framework using 4mm standard gold cylinder and type IV gold alloy was fabricated. In order to measure the fit of the framework we used both contact and noncontact coordinate measurement machine and data was processed by computer program. After superimposition of gold framework and master model numeric image data the distances between gold cylinder bearing surfaces and abutment replica bearing surfaces, and the angle deviations between gold cylinder and abutment replica centroid points were calculated. The results were as follows 1 The total mean distance (p<0.01) and standard deviation (p<0.001) between the gold cylinders and abutment bearing surfaces were significantly decreased after EDM 2. The total mean of maximum distances was significantly decreased after EDM (p<0.05). 3. After EDM, the mean angle deviation between centroid points was decreased.

  • PDF

The Accuracy of Master Cast for Implant Prosthesis According to the Types of Impression Tray and Splinting Methods of Impression Copings (인상용 트레이의 종류와 인상용 코핑의 연결고정이 임플랜트 주모형의 정확성에 미치는 영향)

  • Lee, Jee-Hyuk;Choi, Yu-Sung;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.4
    • /
    • pp.433-445
    • /
    • 2010
  • The aim of this study was to evaluate the fixation effect by connecting impression copings and to compare the three types of impression trays which were used in open tray impression technique. Experimental groups used 3 types of impression trays which are custom tray, plastic metal combination tray and polycarbonate stock tray. These three groups were subdivided into splinted and non-splinted impression copings group. The total number of experimental groups was six. 10 specimens were made for each group. We used 1-screw test, observing the specimen on which only one side abutment of reference framework was fixated with 20 Ncm. The gap between implant analogue and abutment of the other side was observed by stereo microscope. It was measured at 6 points in each specimen. Measuring value was selected when same result was revealed 3 times. Recorded data were statistically analyzed. Whether impression copings were splinted or not, there was no significant difference among custom tray group, plastic metal combination tray group, and polycarbonate stock tray group. Significant statistical difference in vertical fit discrepancy was found between splinted and non-splinted impression copings group with custom tray, plastic metal combination tray and polycarbonate stock tray (p<0.05).

A COMPARATIVE ANALYSIS OF THE ACCURACY OF IMPLANT IMPRESSION TECHNIQUES BY USING STRAIN GAUGE (Strain gauge를 사용한 임플랜트 인상법의 정확도 비교)

  • Han, Eu-Taek;Kim, Yung-Soo;Kim, Chang-Whe
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.3
    • /
    • pp.539-549
    • /
    • 1995
  • The purpose of this study was to determine the accuracy of 3 implant impression methods by using strain gauge. The models used for this study were partially edentulous mandibular acrylic resin casts Model A, with two abutment analogs in #46,47 extraction site, represented two implant parallel to to the adjacent natural tooth. Model B represent an anterior implant parallel to the adjacene natural tooth and a posterior implant exhibiting a 15-degree lingual inclination. Master framework were fabricated on the master model, and 3 strain gauges were attached to a master framwork to determine the passivity of fit of the framework to sample casts made by the three impression techniques. The master framework was attached to each sample cast with gold screws, which were tightened with the torque driver to ensure a consistent toque application of 10 Ncm. Universal Digital Measuring System UCAM-5BT was used for strain measuring. Impression techniques studid were : 1. unsplinted tapered impression coping, polyvinyl siloxane, stock tray 2. unsplinted squared impression coping, polyether, custom tray 3. squared impression coping splinted with Duralay resin, polyether, custom tray Through analysis on data from this study, the following conclusions were obtained. 1. There were no statistically significant differences between the mean strain recorded from the sample casts made with the tree impression. But only strain values of model A(parallel group) Y-axis was signifcantly differed between Technique 1 and 3(P<0.05). 2. There was no statistically significant difference between model A(parallel group) and model B(15-degree divergent group).

  • PDF