• 제목/요약/키워드: stimulus mode

검색결과 25건 처리시간 0.023초

세 가지 자극 양식이 실어증자의 언어이해력과 언어표현력에 미치는 영향 (The Effects of Three Stimulus Modes on receptive Language Performance and expressive Language Performance in Aphasics.)

  • 이무경;유재연;이옥분;정옥란
    • 음성과학
    • /
    • 제7권3호
    • /
    • pp.263-272
    • /
    • 2000
  • The purpose of this study was to compare receptive language performance and expressive language performance in 13 patients with aphasia by using three stimulus presentation modes: Stimulus mode I (picture), Stimulus mode II (written word), Stimulus m (question using verbal explanation). The stimulus consisted of 10 words. They included 5 functional words and 5 non-functional words. The 13 subjects with aphasia were divided into 2 aphasic types: 5 Broca's aphasics and 8 anomie aphasics. The results were as follows: Firstly, the three stimulus modes didn't affect receptive language performance of aphasia subjects. Secondly; the three stimulus modes were effective on expressive language performance of aphasia subjects. Particularly, stimulus mode II (written words) was effective in naming the aphasia subjects. Thirdly, the functional words with high frequency were better than non-functional words with low frequency on expressive language performance, but not on receptive language performance of aphasia subjects. Finally, the interaction between three stimulus modes and the functional (nonfunctional) words affected expressive language performance only, but not receptive language performance. Particularly, presenting stimulus in written words which are functional words produced the best expressive language performance.

  • PDF

인공와우 이식자에서 자극 잡파를 이용한 고장 평가 (Evaluation of the Device Failure Using Stimulus Artifact in the Cochlear Implantee)

  • 허승덕;김상렬;안중기;정동근;강명구
    • 음성과학
    • /
    • 제14권2호
    • /
    • pp.35-42
    • /
    • 2007
  • The aim of this study is to analyze the correlation between current intensity and amplitude of stimulus artifact on the cochlear implantee, and to find out basic information to check the device failure. Subjects were a prelingual child and 3 postlingual adults with more than severe hearing losses. The charge-balanced biphasic pulses were presented at stimulus rates of 11 pulses per second, each pulse width of $25{\mu}s$ with monopolar mode(MP1+2). Current intensities were delivered at 27.5, 33.7, 41.3, 50.5, 61.9, $75.8{\mu}A$. Stimulus artifacts were recorded by evoked potential system. This procedure was performed just before the initial stimulation, and then, the amplitude of stimulus artifacts were compared with each current intensity. The amplitude of stimulus artifacts was increased significantly according to the current intensity (p<0.01). The results suggest that the change of the amplitude of stimulus artifact can be used as a good cue to check the device failure in the cochlear implantee.

  • PDF

L2 proficiency and effect of auditory source in processing L2 stops

  • Kong, Eun Jong;Kang, Jieun
    • 말소리와 음성과학
    • /
    • 제7권3호
    • /
    • pp.99-105
    • /
    • 2015
  • The current study investigates whether Korean-speaking adults show differential sensitivities to the sources of auditory stimuli (L1 Korean and L2 English) in utilizing VOT and f0 in the perceptual mode of L2 stops, and how the L2 proficiency interacts with the learners' low-level phonetic sensitivities in L2 perceptual mode. 48 Korean learners of English participated in the perception experiments where they rated the goodness of English /t/ and /d/ using an analogue scale. Two sets of stimuli (English and Korean sources) were prepared by manipulating VOT (6-steps) and f0 (5-steps) values of productions by an English male (L2 source condition) and a Korean male (L1 source condition). Findings showed that, in judging /t/-likeness, the listeners responded differently to the two auditory stimulus conditions by relying on VOT significantly more in English source condition than in Korean source condition. The listeners' English proficiency did not interact with these differential sensitivities to the auditory stimulus source either along the VOT dimension or the f0 dimension. The results of the current study suggest that low-level contextual information of the auditory source can affect the learners in faithfully being in the L2 perceptual mode.

경피신경전기자극기를 이용한 비지각적 감각자극 강도가 뇌혈류에 미치는 영향 (Effect of Non-perceptual Sensory Stimulation Intensity Using Transcutaneous Electrical Nerve Stimulation on Cerebral Blood Flow)

  • 정주연;강창기
    • 감성과학
    • /
    • 제27권2호
    • /
    • pp.81-90
    • /
    • 2024
  • 본 연구에서는 경피신경전기자극(TENS)을 이용하여 다양한 자극 강도에 따른 뇌혈관에 미치는 영향을 확인하고자 한다. 특히 비지각적 감각의 전기자극을 통해 총경동맥(CCA)에서의 혈류 변화 및 혈관의 구조적인 변화를 확인해 보고자 한다. 본 연구에는 20대의 건강한 성인 24명이 참여하였다. 자극 강도는 감각 역치 미만, 감각 역치, 그리고 감각 역치 초과 세 가지를 각각 랜덤 순서로 적용하였다. 측정위치는 CCA 분기점의 1cm 하단에서 측정하였고, 혈류속도는 C-mode 도플러, 혈관의 구조는 B-mode 영상을 통해 측정하였다. 측정은 각각의 자극별로 중재 전, 중재 중, 그리고 중재 후에 수행하였고 각 세션마다 혈압의 변화를 측정하였다. 그 결과 최고 수축기 속도(PSV)는 역치미만의 비지각적 감각자극에서 중재 후 유의하게 감소함이 확인되었다(p = .008). 역치 미만의 자극 후 PSV는 자극 전보다 평균 3.04% 유의하게 감소한 것으로 나타났다(p = .011). 반면 CCA의 혈관 직경의 변화는 모든 강도에서 자극 전후 유의한 변화가 나타나지 않았다. 본 연구에서 적용한 단시간의 비지각적 전기자극이 혈관의 직경이나 혈압의 유의한 변화를 주지 않으면서 즉각적인 혈류속도 감소에 효과가 있음을 발견했다. 따라서 본 연구는 경동맥 부위에 환자의 불편함과 부작용이 없는 전기자극을 통해 뇌혈류의 조절이 가능하다는 것을 보여주는 중요한 시도로 평가될 수 있다.

경험적 모드 분해를 이용한 시각자극 관련 과제수행에 대한 뇌 유발전위 진폭과 위상 변화 분석 (Amplitude and phase analysis of the brain Evoked Potential about performing a task related to visual stimulus using Empirical mode decomposition)

  • 이벽진;유선국
    • 감성과학
    • /
    • 제18권1호
    • /
    • pp.15-26
    • /
    • 2015
  • 본 논문에서는 경험적 모드 분해 방법을 이용하여 시각자극 출현에 따른 과제 수행 시 발생하는 뇌 유발전위의 ${\theta}$${\alpha}$대역에 대한 진폭과 위상변화를 확인하였다. 과제수행에 대한 뇌 유발전위를 구성 주파수 대역 별로 분해하기 위하여 경험적 모드 분해 방법을 적용하였고, 분해된 각 내재모드함수에 힐버트 변환을 적용하여 뇌 유발전위의 ${\theta}$${\alpha}$대역의 순간 진폭과 위상 변화를 확인하였다. 과제 수행 시 뇌 유발전위의 P2, N2과 P3지점에서 ${\theta}$${\alpha}$대역의 진폭이 크게 관찰되었으며, N1, P2부근에서 순간 위상의 변화가 최대가 되었다. 시각 자극 출현에 따른 응시 상태에서는 두 대역 모두 관련된 위상 변화시점이 확인되지 않았다. 대역통과필터 방법 적용 시, 경험적 모드 분해 방법에 비해 시간과 주파수 해상도가 떨어졌으며, 필터의 파라미터에 따라 위상 변화 시점의 결과에 차이가 발생하였다. 연구를 통해 ${\theta}$${\alpha}$대역이 시각 자극 출현에 따른 과제 수행에 대한 뇌 유발전위의 주요성분인 ${\theta}$${\alpha}$대역의 위상변화와 뇌 유발전위의 생성을 위상 변화와 연관 지어 해석하였다.

소아안신탕(小兒安神湯)이 STRESS를 유발한 흰쥐의 적출심장(摘出心臟)에 미치는 영향 (Effects of Soaansintang(SOAT) on the hemodynamics and electrocardiogram of isolated rat hearts induced by electrical stimulation)

  • 이승준;이진용;김덕곤
    • 대한한방소아과학회지
    • /
    • 제14권2호
    • /
    • pp.1-32
    • /
    • 2000
  • It has long been known that SOAT is effective for sudden palpitation occurring unexpectedly in Oriental Medicine. However, effect of SOAT on the isolated heart has not been studied yet. The purpose of this study is to investigate the effect of SOAT on hemodynamics and ECG of isolated rat hearts induced by electrical stimulation using Langendorff perfusion apparatus for nonworking heart. SOAT extract was manufactured by water-alcohol precipitated method. Sprague-Dawley rats weighting $120{\sim}150g$ were used for the experiments, Subject animals were divided into four groups, which are consisted of 1) control(Group orally administered by normal saline 1ml for 14days), 2) sample A(Group orally administered by SOAT extract 1ml for 14days), 3) sample C(Group injected by SOAT extract 0.5ml after stimulation, 4) sample C(Group injected by SOAT extract 1ml after stimulation. To evluate the effects of SOAT on hemodynamics and ECG of isolated rat heart induced by stimulation, heart rate, left ventricular pressure, systolic power, diastolic power, coronary artery perfusion volume and ECG were measured using Langendorff apparatus in both stimulation mode(5 volts, 450 beats/min) and arrythmic mode(5 volts, 420 beats/min including 60 beats/min) The results obtained are as follows : 1. After receiving stressful electrical stimuli, isolated heart showed the heart rate, left ventricular pressure, systolic power, diastolic power, coronary artery perfusion volume were all decreased temporarily, but perfusion continued longer recovery to the control state appeared. However, the coronary artery perfusion volume diminished continuously. 2. The heart rates did not change significantly with both stimulation mode and arrhythmic mode, among experimental groups. 3. The left ventricular pressure showed with both stimulation mode and arrhythmic mode, the significant changes(p<0.05) especially in the injection sample group. In case of stimulation mode, low concentration injection group(0.5ml) was more significantly increased rather than high concentration group(1ml) and in case of arrhythmic mode, high density group(1ml) was so increased than the other(0.5ml). 4. For the systolic power and diastolic power, no significant changes were noticed in the stimulation mode, but in the arrhythmic mode of injection sample groups, significant change(p<0.05) was noticed in both systolic power and diastolic power. Specially the high concentration group(1ml) showed more significant increase than the low concentration group. 5. For the coronary artery perfusion volume, no significant change difference among sample groups was observed in both the stimulation mode and the arrhythmic mode. 6. For the ECG recordings, arrhythmia was induced by electrical stimulus of arrythmia mode and after the stimulus was removed, irregular wave appeared temporarily, but as perpusion continued, recovery to the control state was abtained like the stimulation mode. According to the above results, SOAT significantly changed the hemodynamic data from the electrically stressed, isolated hearts of connected Langendorff perfusion apparatus and we propose SOAT has the direct effects on the muscular function of heart.

  • PDF

신경자극반응 측정을 위한 플랫폼 구현에 관한 연구 (A Study on Platform Development for Nerve Stimulation Response Measurement)

  • 신효섭;김영길
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2009년도 추계학술대회
    • /
    • pp.521-524
    • /
    • 2009
  • 신경자극반응 측정 플랫폼을 구현하는데 있어서 손가락 움직임을 감지하는 것이 중요한 요소로 작용하고 있다. 이것은 손가락의 움직임에 따라 신경자극과 근육반응이 달라지기 때문이다. 즉, 손가락의 움직임을 감지해서 신경 자극 Actuator 및 근육 반응 감지를 위한 H/W 개발이 필요한 것이다. 또한 임베디드 기반으로 가기위한 저전력 CPU를 사용하였다. H/W 구성은 isolation power부분, 정전류조절, High impedance INA, 증폭기부분이 있으며 Micro-controller에서는 stimulus mode 및 Current 의 상태를 통제하고, AD converter를 통해 얻어진 Low Data를 처리 시스템을 구현한다.

  • PDF

어린이의 공감성립(共感成立)에 있어서의 요인분석(要因分析) (Several Factors Influencing on Children's Empathic Behavior)

  • 김나영
    • 아동학회지
    • /
    • 제6권2호
    • /
    • pp.59-71
    • /
    • 1985
  • The purpose of this study was to analyze the effects of both social-status and mode of stimulus-presentation on children's empathic behavior, where empathy is defined as either the comprehension and recognition of an affective state in stimulus persons (others) or the empathic response to that perception. Middle-and lower-class kindergarten children were presented with a series of either short-sentence stories or short-pictorial stories. The subjects were asked to indicate how the child in each situation felt by selecting a "happy", "sad", or "angry" face to complete the picture accompanying each story. Immediately following the first question, children were asked to state verbally how the child in the picture might feel. The main results were (1) The mean empathy scores for the comprehension and recognition of an affective state in others and the empathic response to that perception was higher in middle-class children than in lower-class children. (2) There were differences in empathy scores to the three affective situations, i.e. the mean score for both happiness and sadness was significantly greater than for aggression, and (3) The empathy scores in the pictorial-stories were greater than in the sentence-stories.

  • PDF

디지털 위성 방송 기본 화질과 전송 화질의 주관적 평가 시험 (The Subjective Assessment Testing of Basic and Transmission Video Quality for Digital Broadcasting Satellite)

  • 박대철;김용선;유태선;전병민
    • 방송공학회논문지
    • /
    • 제2권1호
    • /
    • pp.24-35
    • /
    • 1997
  • 디지털 위성 방송의 비디오 화질 의 주관적 평가 시험을 MPEG-2 MP@ML 표준에 기초하여 설계된 하드웨어 부호화기/복호화기 기본 화질 평가와 위성 전송 에러 화질 및 전송 시스템 성능에 따른 화질 열화에 대한 시험을 위성 시뮬레이터(Satellite Simulator)를 사용해 실시간에서 수행하였다. 평가 방법으로는 CCIR 500-5의 2중 자극 열화 척도법과 2중 자극 연속 화질 척도법을 사용하였다. 또한 디지털 위성 방송 시스템의 화질을 전체 시스템 즉 MPEG-2코덱, 다중화 장치, 채널 코덱, 변복조기, 안테나 등을 연계시켜 여러 비트율과 비트 오류율에서 평가 시험을 수행함으로써 시스템 전반적인 성능을 평가하고 위성 전송로와 수신 시스템을 연계한 전송로 환경을 고려한 보다 통합적인 화질 평가 시험을 수행하였다. 특히 전송로 오류 화질 평가에 있어서 주어진 5가지의 BER에 대하여 전송 에러 화질은 평균적으로 5단계 카테고리에서 3.9이상을 유지함을 알 수 있었다. 필름 모드와 같은 낮은 비트율(특히 2Mbps)에서 코덱 시스템의 부호화 화질의 성능은 영상 소스의 통계적 성질에 따라 크게 좌우됨을 알 수 있었고 평균적으로 절대 평가 기준에서 2.7정도를 기록하였다.

  • PDF

신경자극반응 측정 센서를 이용한 마취 시 잔여근이완 감지 플랫폼 구현 (Residual Neuromuscular Sensing Platform Development using Sensor of Nerve Stimulation Response Measurement during Anesthesia)

  • 신효섭;김영길
    • 한국정보통신학회논문지
    • /
    • 제14권6호
    • /
    • pp.1505-1510
    • /
    • 2010
  • 본 논문은 근육의 기능을 조절하는 신경말단에 전기적인 자극을 가하여 신경의 반응 정도를 측정하는 플랫폼 구현에 관한 연구로써, 전기 자극에 대한 신경반응이 가해지는 전류량, 가해지는 전류지속시간, 전극위치에 따른 반응을 측정하였다. 신격자극의 전극 위치는 표면말달 운동신경이면 어느 신경이든지 가능하고, 신격자극 양식에는 단순연축자극(Single Twitch Stimulation), 사연속자극(Train-of-four, TOF), 두 집단 발사자극(Double Burst Stimulation, DBS)이 있다. 임베디드 시스템기반으로 가기위한 저전력 MCU를 선정하고, 기본적인 신경자극반응 측정 센서의 민감도를 알아보기 위해 센서 인터페이스를 구성하여 반응정도를 측정해야 한다. 그리고 측정된 Data의 정확도를 높이기 위해 고성능의 AD Convertor 선정하여 플랫폼을 구현하였다.