• 제목/요약/키워드: stimulator

검색결과 332건 처리시간 0.022초

영구전치(永久前齒)의 치근발육단계(齒根發育段階)에 따른 Electric Pulp Stimulator에 대(對)한 치수반응(齒髓反應) (PULP RESPONSES TO AN ELECTRIC PULP STIMULATOR IN THE DEVELOPING PERMANENT ANTERIOR DENTITION)

  • 최재홍
    • 대한소아치과학회지
    • /
    • 제6권1호
    • /
    • pp.27-33
    • /
    • 1979
  • The author studied the response to the stimulation of an electric pulp stimulator of healthy 854 permanent anterior teeth in 122 children aged from six to eleven years old, during different stages of tooth development. The results were as followings: 1) In completely open apices, 13.1% (18 teeth) showed positive responses, and 86.9% (120 teeth) showed negative responses. In two-thirds open apices 33.1% (75 teeth) showed positive responses, and 66.9% (152 teeth) showed negative responses. In one-third open apices 57.8% (118 teeth) showed positive responses, and 42.2% (86 teeth) showed negative responses. In closed apices 80.0% (228 teeth) showed positive responses, and 20.0% (57 teeth) showed negative responses. 2) The number of positive responses increased in each upper and lower central incisors during the stages of root development, but not in upper lateral incisors. 3) There were no significant differences statistically in responses between the teeth of the right and left sides and the upper and the lower jaw, in the same stages of root development.

  • PDF

Detection of 1,4-Dihydroxy-2-Naphthoic Acid from Commercial Makgeolli Products

  • Eom, Ji-Eun;Kwon, Sang-Chul;Moon, Gi-Seong
    • Preventive Nutrition and Food Science
    • /
    • 제17권1호
    • /
    • pp.83-86
    • /
    • 2012
  • To support beneficial effects of makgeolli for human health, we investigated for the presence of 1,4-dihydroxy-2-naphthoic acid (DHNA), a bifidogenic growth stimulator (BGS), from commercial makgeolli products. Among eleven makgeolli products (A~K), four showed positive peaks for DHNA in high performance liquid chromatography analysis. Makgeolli product A in particular contained the highest concentration of DHNA (0.44 ppm), as confirmed by liquid chromatography-mass spectrometry. Furthermore, BGS activity of the makgeolli product A was higher than those of products in which DHNA was not detected. These results indicate that makgeolli can be a good source for DHNA and that DHNA-enriched makgeolli could be developed by modifying manufacturing procedures and controlling its microbiota.

전정기관 자극용 회전자극기를 위한 PMSM의 정밀 속도제어 (Precision Speed Control of PMSM for Stimulation of the Vestibular System Using Rotatory Chair)

  • 이태호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.628-631
    • /
    • 2000
  • A new control method for precision robust speed control of a PMSM(Permanent Magnet Synchronous Motor) using load torque observer is presented. With this system we can obtain more reliable eye moving singal(nystagmus) Until now rotating chair system which is called 2D-optokinetic stimulator is used to make dizzincess. However an inclined rotating chair system witch is 3D-optokinetic stimulator is needed to obtain the precise dizziness data. This 3D-optokinetic sitimulator include unbalanced load aused by unbalanced center of mass. For this case new compensation method is considered to obtain robust speed control using load torque observer. To reduce the effect of this disturbance we can use dead-beat observer which has high gain. The application of the load torque observer is published in [1] for position control. A problem of using speed information such as amplifying effect of noise is reduce by moving average process. The experimental results are depicted in this paper to show the effect of this proposed algorithm.

  • PDF

An Inductively Coupled Power and Data Link with Self-referenced ASK Demodulator and Wide-range LDO for Bio-implantable Devices

  • Park, Byeonggyu;Yun, Tae-Gwon;Lee, Kyongsu;Kang, Jin-Ku
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제17권1호
    • /
    • pp.120-128
    • /
    • 2017
  • This paper describes a neural stimulation system that employs an inductive coupling link to transfer power and data wirelessly. For the reliable data and power delivery, a self-referenced amplitude-shift keying (ASK) demodulator and a wide-range voltage regulator are suggested and implemented in the proposed stimulator system. The prototype fabricated in 0.35 um BCD process successfully transferred 1.2 Kbps data bi-directionally while supplying 4.5 mW power to internal MCU and stimulation block.

Leuconostoc mesenteroides CJNU 0147 and Lactobacillus casei CJNU 0588 Improve Growth of a Bifidobacterium lactis Strain in Co-cultures

  • Eom, Ji-Eun;Moon, Gi-Seong
    • Preventive Nutrition and Food Science
    • /
    • 제16권4호
    • /
    • pp.386-389
    • /
    • 2011
  • Previous studies have confirmed that fermented whey produced by Leuconostoc mesenteroides CJNU 0147 or Lactobacillus casei CJNU 0588 display bifidogenic growth stimulator (BGS) activity. The present study sought to determine if the strain itself can improve the growth of bifidobacteria in co-cultures. In reinforced clostridial medium (RCM), both strains stimulated the growth of a Bifidobacterium lactis strain during the exponential phase and also stimulated the growth during almost all growth phases in whey broth. Fermented whey containing viable Leu. mesenteroides CJNU 0147 and L. casei CJNU 0588 cells maintained viability of the B. lactis strain stored at $10^{\circ}C$ in MRS broth. Viable cell count of the B. lactis strain without the fermented whey was decreased to 5.6 log cfu/mL after 15 days, whereas that of the strain with the fermented whey was slightly increased to 7.1 log cfu/mL as compared with initial viable cell count of 6.9 log cfu/mL.

면양(緬羊)의 혼합임파구배양(混合淋巴球培養)의 Micro-technique 정립(定立)에 관(關)한 연구(硏究) (A Microtechnique for Mixed Lymphocyte Culture in the Sheep)

  • 전무형
    • 대한미생물학회지
    • /
    • 제16권1호
    • /
    • pp.65-70
    • /
    • 1981
  • A microculture technique for the mixed lymphocyte culture test(MLC) in the sheep is described. The optimal incubation periods for the MLC are varied from 4 to 6 days depending on the sources of lymphocytes. It is found that a 2.5:1 stimulator-responder cell ratio and the responder cell concentration of $1{\times}10^5$ cells/well produce the highest($^3H$)-thymidine incorporation. Moreover cryopreservation of bovine lymphocytes results in satisfactory and reproducible MLC reaction. It is also evident that the MLC reactions of the sheep are under the control of histocompatibility matching between the stimulator cells and the responder cells. Significance of the technique as a too! for study on cell mediated immunity in sheep system, either normal or squamous cell carcinoma-bearing, are discussed.

  • PDF

마이크로 컴퓨터를 이용한 신경근 차단 감시장치의 개발에 관한 연구

  • 전계록;조진호
    • 대한의용생체공학회:의공학회지
    • /
    • 제11권2호
    • /
    • pp.257-268
    • /
    • 1990
  • A system has been developed for monitoring the effect of neuromuscular blocking frugs and the neuromuscular function during anesthesia and surgery. This system is composed of software and hardware, the latter are nerve stimulator, force transducer, interface board(preamplifier, filter, peripheral input/output) and personal computer (apple ll) , the former are programmed in ASSEMBLY and BASIC language. The nerve stimulator which is controlled by personal computer is capable of delivering single shocks at o.)Hz, train of four at 2Hz and tetanic stimulation at 30, 100, 200Hz. The response, adduction of the thumb, is sensed by the force transducer. The output of the force transducer Is amplified, filtered, converted digital signal and then processed by the per- sonal computer. The personal computer quantia4es twitch and traln of four tesponse and calculates the 74 ratio (Ta/Tl )between the first and fourth response of train of four. This ratio is used to estimate the level of the neuromuscular block. This system has reaserch potential for determining the effect of newer neuromuscular blocking drugs for comparlsion with presently used drugs of alternatively, for delerminig the effects of blocking drugs in altered physilogical states.

  • PDF

적응형 가변 전원 레귤레이터를 내장한 인공 망막용 전류 자극기 (Current Stimulator with Adaptive Supply Regulator for Artificial Retina Prosthesis)

  • 고형호
    • 센서학회지
    • /
    • 제20권4호
    • /
    • pp.254-259
    • /
    • 2011
  • In this paper, a current stimulator circuit with adaptive supply regulator for retinal prosthesis is proposed. In current stimulation systems, the stimulating circuits with wide voltage swing range are needed due to the high impedance of the retina cell and microelectrodes. Thus, previous researches adopt the high voltage architecture to obtain the enough operating range. The high voltage architecture, however, could increase the power consumption and can damage the retina cells. The proposed circuit provides the adaptively regulated supply voltage by measuring the difference between desired stimulation current and the actual stimulation current. The proposed circuit can achieve the extended range of the allowable cell impedance, improved accuracy of the stimulation current, and higher biosafety.

편마비환자를 위한 휴대용 자극시스템 설계에 관한 연구 (A Study on the design of functional electrical stimulation system for hemiplegic patients)

  • 김낙환;박종길;권장우;장영건;홍승홍
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 추계학술대회
    • /
    • pp.99-102
    • /
    • 1996
  • The ultimate object of FES is on the recovering function of body and shape demaged from desease or injury to original state. On this study, object is recovering of gait function of the disabled who, especially, have gait disturbance. Paralyzed muscle from the central nerve disable, if peripheral nerves which be in the lower part of the harmed are activated, muscle contraction is possible. The traumatic trouble, peripheral nerves aren't connected to a central nerve but origin of peripheral nerve cells which are in the lower part of the harmed are alive, react on stimulation. We design 4-channel stimulator, being based on standard stimuli pattern. stimulator is manufactured with compact size and light weight to portable.

  • PDF