• Title/Summary/Keyword: sticking

Search Result 373, Processing Time 0.029 seconds

Sticking Coefficient in Bi-thin Film Prepared by IBS Method

  • Yang, Sung-Ho;Park, Yong-Pil;Chun, Min-Woo;Park, Sung-Gyun;Park, Woon-Shik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.193-197
    • /
    • 2000
  • BSCCO thin films are fabricated via a co-deposition process by an ion beam sputtering with an ultra-low growth rate, and sticking coefficients of the respective elements are evaluated. The sticking coefficient of Bi element exhibits a characteristic temperature dependence : almost a constant value of 0.49 below 73$0^{\circ}C$ and decreases linearly with temperature over 73$0^{\circ}C$. This temperature dependence can be elucidated from the evaporation and sublimation rates of bismuth oxide, Bi$_2$O$_3$, from the film surface. It is considered that the liquid phase of the bismuth oxide plays an important role in the Bi(2212) phase formation in the co-deposition process.

  • PDF

Root cause analysis of sticking in hydraulically actuated multi-disc friction clutch for ship propulsion (선박 추진용 유압작동식 다판 마찰클러치 고착현상 고장탐구)

  • Jeong, Sang-Hu;Kim, Jeong-Ryeol;Shin, Jae-Won
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.41 no.4
    • /
    • pp.330-336
    • /
    • 2017
  • This study performs a root cause analysis of the sticking that occurs in the hydraulically actuated wet type multi-disc friction clutch in a ship's diesel engine propulsion system that uses rubber elastic coupling. The fishbone method was used to study the sticking through dismantling investigation of the reduction gear and clutch, investigation of the components, and onboard system tests including nondestructive testing. The friction plate sticking is caused by the slip due to friction heat resulting from the leakage of control oil through cracks in the assembled hollow shaft. The friction plate cooling oil also leaks simultaneously through the crack, and partial sticking occurs due to the hot spots in the friction plates. These are caused by insufficient amount of cooling oil due to oil leakage.

Influence of Temporal and Permanent Image Sticking Characteristics Under Variable Panel Working Gas Pressure in 42-in. AC-PDPs

  • Park, Choon-Sang;Jang, Soo-Kwan;Kim, Jae-Hyun;Tae, Heung-Sik;Jung, Eun-Young;Ahn, Jung-Chull;Heo, Eun-Gi
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.1617-1620
    • /
    • 2008
  • The effects of the temporal and permanent bright image stickings were examined under variable panel working gas pressure in the 42-in. ac-PDP with a high Xe (11 %) content. In the cells with and without temporal and permanent bright image stickings, the display luminance, firing voltage, and Vt closed curve were measured relative to the working gas pressure. With a decrease in the working gas pressure, the temporal bright image sticking was observed to be reduced, whereas the permanent bright image sticking was observed to be deteriorated.

  • PDF

Adsorption Property of Silicone Rubber Sticking Chuck for OLED Glass Substrate

  • Kim, Jin-Hee;Chung, Kyung-Ho
    • Elastomers and Composites
    • /
    • v.50 no.1
    • /
    • pp.55-61
    • /
    • 2015
  • Manufacturing process of OLED contains adsorption-desorption process of glass substrate. There are several adsorption methods of glass substrate such as atmospheric pressure, vacuum and electrostatic adsorption. However, these methods are very complex to connect system. Therefore, the adsorption method using silicone rubber based sticking chuck was proposed in this study. Three types of silicone rubbers having 0, 19.3 and 32.2 wt% of fluorine were used and their mechanical properties, surface energies and adsorption properties were examined. According to the results ${\sigma}_{300}$ and hardness increased with increasing fluorine contents, but elongation was decreased. Also, fluorosilicone rubber containing 32.2 wt% of fluorine showed the lowest surface tension, among three types of rubber and resulted in the highest initial tack with glass substrate. After the adsorption-desorption test of 300,000 cycles was performed, the adsorption force of S-1 (silicone rubber) decreased largely from 2.34 to 0.73 MPa. However, the S-3 (fluorosilicone rubber having 32.2 wt%. of fluorine) decreased only from 3.15 to 2.24 MPa. From this study, we obtained the valuable equations related to long term durability of silicone based sticking chuck. Finally the transfer of silicone rubber to glass substrate with the adsorption-desorption process was not occurred and this phenomenon was examined by UV-Visible spectroscopy.

Sticking Characteristics in Bi2Sr2CanCun+1Ox Thin Films Fabricated by using the Evaporation Method to Improve the Sticking Ratio (부착율 개선을 위해 증발 법으로 제작한 Bi2Sr2CanCun+1Ox 박막의 부착 특성)

  • 천민우;박용필
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.11
    • /
    • pp.1029-1034
    • /
    • 2003
  • The Bi$_2$Sr$_2$Ca$_{n}$Cu$_{n+1}$ O$_{x}$, superconducting thin films arc fabricated by using the sputtering and evaporation method. Because we confirmed the sticking ratio of Bi element in the Bi$_2$Sr$_2$Ca$_{n}$Cu$_{n+1}$ O$_{x}$ superconducting thin film fabricated by using the sputtering method was much lower than the expected value, to get the enough number of the flakes of Bi, faraday cup was used to evaporate Bi clement. As a result of the fabrication, Bi 2201 and Bi 2212 single phases could be made by the optima of deposition condition. And we confirmed the sticking coefficient of Bi element was clearly related to the temperature change of the substrate and the generation of Bi22l2 phase

Impact on Respiratory Diseases of Acupoint Sticking in Dog-Days (삼복첩(三伏貼)의 호흡기 질환에 대한 영향)

  • Lee, Sun-Haeng;Kim, Cho-Young;Chang, Gyu-Tae
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.26 no.2
    • /
    • pp.1-12
    • /
    • 2012
  • Objectives Acupoint sticking in Dog-Days is one of Oriental medical prophylaxis to prevent winter diseases over the summer. The research has been conducted to evaluate the efficacy of Acupoint sticking in Dog-Days. Methods We visited one kindergarten in Dog-Days of 2011, and the subjects were 72 children (38 boys, 34 girls, $58.24{\pm}12.28$ months, 37-105 months). 72 children were attached Socheongo to BL-13, BL-15, BL-17 for 4-6 hours. Exacerbating effect or non-improvement in respiratory symptoms before and after the treatment were nullified. Results 31 children (43.1%) have shown positive effect in Socheongo, with no significant differences among the groups. There were significant improvements in Socheongo group in frequency of having cold, duration and visits; duration under tonsillitis, frequency of having otitis media, duration and visits (P<0.05). Lung weak score also had significant decrease in the three times Socheongo group, from $11.27{\pm}5.61$ to $9.90{\pm}4.66$ (P=0.030). Side effects has been reported in Socheongo group; 7 erythema (9.7%), 2 heating (2.8%), 9 pruritis (12.5%), 2 vesicle (2.8%), 13 scar (18.1%). Conclusions Acupoint sticking in Dog-Days improves lung weak symptoms such as common cold, tonsilitis, and otitis media in children older than three years old, throughout the three times of the treatment. However, the ways to reduce the side effects are needed.

A Study on Effect and Satisfaction of Acupoint Sticking in Hottest Period of Summer (삼복첩의 치료 효과와 만족도에 대한 연구)

  • Song, Ji Hyun;Lee, Jin Hwa;Kim, Yun Hee
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.32 no.1
    • /
    • pp.1-10
    • /
    • 2018
  • Objectives The purpose of this study is to understand effect on respiratory disease and satisfaction of parents about acupoint sticking in hottest period of summer. Methods A survey was conducted to the parents of their children who took acupoint sticking in Dog-days for two years in a row. 17 children (10 boys, 7 girls, 4.0-12.11 years) were attached Socheongo to BL-13, BL-15, BL-17 for 3 hours. In terms of the effectiveness of the therapy, the treatment only considered as effective when there is any improvement in respiratory symptoms. Results 11 children (64.7%) from the study group have shown positive effect. There were significant improvements in frequency of having a cold or duration of a cold; duration of rhinitis; frequency of having empyema or its duration; frequency of having bronchitis; frequency of having pneumonia; frequency of having otitis media. Respiratory health VAS (Visual Analog Scale) had significant increase from 5 to 6.71 (p<0.05). 7 parents (41.2%) were satisfied with acupoint in hottest period of summer and 16 parents (94.1%) wanted to have their children get treated again in next year. From the survey, inconveniences of acupuncture were weak attachment of the acupoint (23.5%), long attaching time (11.8%), pressure about number of treatments (5.9%), worry about side effects (5.9%). Side effects have been reported; 2 pruritus (11.8%), 1 pruritus and erythema (5.9%). Conclusions Acupoint sticking in hottest period of summer improves lung symptoms in children older than three years old. However, the ways to reduce the side effects and inconveniences are needed.

Hydrogen Reduction of NiO Particles in a Single-Stage Fluidized-Bed Reactor without Sticking

  • Oh, Chang-Sup;Kim, Hang Goo;Kim, Yong Ha
    • Korean Journal of Materials Research
    • /
    • v.26 no.2
    • /
    • pp.79-83
    • /
    • 2016
  • A commercial NiO (green nickel oxide, 86 wt% Ni) powder was reduced using a batch-type fluidized-bed reactor in a temperature range of 500 to $600^{\circ}C$ and in a residence time range of 5 to 90 min. The reduction rate increased with increases in temperature; however, agglomeration and sintering (sticking) of Ni particles noticeably took place at high temperatures above $600^{\circ}C$. An increasing tendency toward sticking was also observed at long residence times. In order to reduce the oxygen content in the powder to a level below 1% without any sticking problems, which can lead to defluidization, proper temperature and residence time for a stable fluidized-bed operation should be established. In this study, these values were found to be $550^{\circ}C$ and 60 min, respectively. Another important condition is the specific gas consumption rate, i.e. the volume amount ($Nm^3$) of hydrogen gas used to reduce 1 ton of Green NiO ore. The optimum gas consumption rate was found to be $5,000Nm^3/ton$-NiO for the complete reduction. The Avrami model was applied to this study; experimental data are most closely fitted with an exponent (m) of $0.6{\pm}0.01$ and with an overall rate constant (k) in the range of 0.35~0.45, depending on the temperature.

Plasma Dechucking Process를 이용한 Dynamic Alignment Error 개선

  • Yu, Jin-Gyun;Chae, Min-Cheol;Yun, Jeong-Bong;Kim, Jong-Geuk
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.203.1-203.1
    • /
    • 2016
  • Poly etch 설비에서 발생하는 dechuck 불량에 의한 Dynamic Alignment(DA) error는 poly etch 설비에서의 고질 적인 문제이다. 발생 원인은 ElectroStatic Chuck(ESC)의 노후화 혹은process plasma에 의한 attack 등으로 ESC와 wafer간 dechucking이 진행될 때 wafer내의 전하가 완전히 discharge되지 못하여 wafer Sticking에 의한 sliding이 발생되며 심해지면 Dynamic Alignment(DA) Error가 발생한다. DA error 발생 되면 particle down으로 wafer는 scrap 되며 DA error가 지속적으로 발생하는 설비는 ESC 교체를 하고 있다. ESC 교체비용도 매우 크며 교체 전까지 설비가 멈추어있는 시간적인 손실이 발생하게 된다. Dechucking을 진행할 때 Wafer에 잔존하는 전하를 제거 하여 Wafer의 sticking을 줄여 DA error를 근원적으로 방지하기 위해 plasma를 이용하여 wafer와 ESC를 하나의 electric circuit으로 연결시키는 방법으로 wafer에 잔존하는 전하를 제거 시키고자 하였다.

  • PDF

The effects of short persistent CCFL in Blinking Back Light Unit to reduce blur on TFT-LCD

  • Han, J.M.;Bae, K.W.;Kim, S.Y.;Kim, Y.H.;Lim, Y.J.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.694-697
    • /
    • 2003
  • In applying LCD to TV application, one of the most significant factors to be improved is image sticking on the moving picture. LCD is different from CRT in the sense that it's continuous passive device, which holds images in entire frame period, while impulse type device generate image in very short time. To reduce image sticking problem related to hold type display mode, we made an experiment to drive LCD like CRT. We made articulate images by turn on-off backlight, and we realized the ratio of Back Light on-off time by adjusting between on time and off time for video signal input during 1 frame (16.7ms). Conventional CCFL (cold cathode fluorescent lamp) cannot follow fast on-off speed, so we evaluated new fluorescent substances of light source to improve residual light characteristic of CCFL. We realized articulate image generation similar to CRT by blinking drive. As a result, reduced image sticking phenomenon was validated by naked eye and response time measurement.

  • PDF