• Title/Summary/Keyword: step height

Search Result 473, Processing Time 0.027 seconds

The Kinematic Analysis of Cross Over Step and Delivery Phase in Female Javelin Throwing Players (여자 창던지기 크로스 스텝과 딜리버리 국면의 운동학적 분석)

  • Lee, Young-Sun
    • Korean Journal of Applied Biomechanics
    • /
    • v.14 no.3
    • /
    • pp.149-163
    • /
    • 2004
  • This study analyzed kinematic variables about the cross step, the delivery and the release for women's javelin athletics recorded over 50m in the 2004 Busan International Athletics Competition. It was used the Kwon3D Motion Analysis Package Ver. 3.1 Program(Kwon, 2000) for analysing the kinematic variables about the distance, the velocity, and the angle, then we had the results as follows; 1 In the Cross step phase, the COG velocity was low because their step length was short. To keep the CM velocity from the approach to the last cross over step contact, the athletes have to keep the longer step length within about 130% of the athletics' height. 2. In the Delivery phase, the athletics' COG height was gradually lower, and the deceleration of the COG was going up. As the same in the cross step, Therefore the athletes have to increase the step length within about 100% of their height, in order to increasing the COG velocity. And it was shown they have to make small angle of the elbow as possible from the right foot contact to the left foot contact in order to being the big acceleration of the upperarm at the release phase. 3. In the release phase, it was shown to being low position of the release point as the COG was low and then the release velocity of the upperarm was low. Specially when the shoulder lean lateral angle is big at the release phase, it was shown they have a excessive release angle. And, when it was shown the high rotation angle of the shoulder, the shoulder was opened forward bigger than the trunk was opened forward. So the transmission of velocity from the proximal segments was a fast change.

Characteristics of Spatio-Temporal Parameters in Parkinson's Disese During Walking (보행 시 파킨슨병 환자의 시·공간적 지표의 특성)

  • Lee, Sung-Yong;Woo, Young-Keun;Shin, Seung-Sub;Jung, Seok
    • Physical Therapy Korea
    • /
    • v.15 no.3
    • /
    • pp.35-43
    • /
    • 2008
  • The purpose of this study was to compare spatio-temporal parameters during walking between patients with idiopathic Parkinson's disease and a control group matched for age, height, and weight. Thirty-three subjects were included in this study. Fifteen normal subjects (age, $63.3{\pm}5.8$ yrs; height, $164.1{\pm}8.7$ cm; weight, $60.7{\pm}17.5$ kg) and eighteen patients (age, $64.0{\pm}7.7$ yrs; height, $164.7{\pm}7.3$ cm; weight, $63.6{\pm}7.7$ kg) participated in the study. The Vicon 512 Motion analysis system was used for gait analysis in each group during walking, with and without an obstacle. The measured spatio-temporal parameters were cadence, walking speed, stride time, step time, single limb support time, double limb support time, stride length, and step length. Results in stride length and step length, when walking without an obstacle, showed a significantly greater decrease in the patient group compared to the control group. During walking with an obstacle, the patient group showed a significantly greater decrease in the step length as compared to the control group. For the control group, there were significant decreases in parameters of cadence and walking speed and increases in parameters of stride time, step time, and single limb support time when walking with an obstacle. The patient group had lower cadence and walking speed and higher stride time, step time, and single limb support time during walking with an obstacle than in walking without an obstacle. These results suggest that patients with Parkinson's disease who walk over an obstacle can decrease cadence, stride length, and step length. Further study is needed, performed with more obstacles and combined with other external cues, such as visual or acoustic guides.

  • PDF

Display station anthropometrics: Preferred height and angle settings of CRT and keyboard

  • Miller, Win;Suther Ill, Thomas-W.
    • Journal of the Ergonomics Society of Korea
    • /
    • v.5 no.2
    • /
    • pp.37-44
    • /
    • 1986
  • This study investigates display station physical adjustments preferred by a sample of visual display terminal operators. Participants in the study were selected to assure representation of extremely short and extremely tall persons, as well as persons of midrange physical stature. Individual operators were led through a step-by-step sequence to determine their preferred initial settings of seat height, keyboard height and slope angle, and CRT height and tilt angle. Each operator then performed a brief text input tase, after which final preferred adjustments were measured. Intermeasure correlation strongly suggest that "flat" (low slope angle) keyboards are in appropriate for short operators who select low seat heights. In addition, the keyboard angle adjustments preferred by most operators substantially exceed a current German ergonomic display station requirement.

  • PDF

Improvement of Measurement Accuracy for Absolute Height by Using Two Types of Doppler and Heterodyne Optical Interferometry (도플러방식과 헤테로다인 방식의 광간섭법을 병용한 절대높이 측정 정밀도 향상)

  • Ahn, Geun-Sik;Jhang, Kyung-Young;Moon, Heui-Kwan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.13 no.6
    • /
    • pp.128-135
    • /
    • 1996
  • This paper proposes a high precision measurement technique to obtain the height of gage block with a few millimeter height. The proposed technique is consisted of two steps : In the first step, laser position transducer and electric micrometer are adopted to obtain a coarse value of the height of gage block, and then, in the second step, heterodyne laser interferometry is adopted to acquire the precision value. A new kind of phase detector is constructed in the low cost for the heterodyne interferometer and its linearity with ${\pm}1%$ is confirmed by experiment. Also measurement error factors due to enviroments are discussed and methodology to reduce such errors is proposed. Preliminary experiments are carried out for the gage blocks of as high as a few millimeter.

  • PDF

Restoration design of step-pool sequence in mountain streams (산지하천의 스텝-풀 연속체 복원설계)

  • Kim, Ki Heung
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.1
    • /
    • pp.29-43
    • /
    • 2020
  • The purpose of this study is to propose the design criteria and detailed design model by reviewing the issues related to geometry, formation process, destruction process, hydraulic function, restoration and ecological function of the step-pool from the existing research results, to apply the step-pool sequences to river restoration. Based on the analysis and review results, the design criteria for the structure and size of the step-pool are presented as ratio of the step spacing and the channel width, ratio of the unit step slope and channel slope, and ratio of step height and the particle size. To ensure structural stability of the step, stability analysis method of overturning based on the keystone theory was proposed as a design criterion. As a detailed design concept, a layout model was proposed by applying the imbricating structure of keystones and arch stones to the planar, longitudinal and transverse configurations of the step-pool.

A Study on the cracks ways minimizing at circular forming (원형포밍 성형 시 크랙 발생 최소화 방안에 관한 연구)

  • Son, Jong-Min;Kim, Sei-Whan;Lee, Chun-Kyu
    • Design & Manufacturing
    • /
    • v.10 no.3
    • /
    • pp.20-24
    • /
    • 2016
  • Foaming is a step of forming by the ratio of the internal combustion chamber in a state where the in flow of the material is suppressed, if the diameter is small and a high to a crack generated on the molding is not possible. The present study, we studied using as part experiments for forming the circular shape of the forming height of 10 mm without the occurrence of cracks, results preformed primary, the need to set the height of the forming than the height of the product, preformed secondary. It was able to increase the height of the molded product with less than the height of the next step to be carried out compression processing to create a small comer of the desired shape. In addition, it was found that on a great influence on the quality of the final quality on the final molding of the primary preformed, secondary.

Unsteady Wall Pressure Fluctuation Generated from the Impinging Vortex on the Chamfered Forward Step (모따기된 전향계단에 부딪치는 와류에 의한 비정상 벽면압력 변동)

  • Ryu, Ki-Wahn;Lee, Jun-Shin
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.312-317
    • /
    • 2001
  • Modifying effects of the rectangular forward step for suppressing the unsteady pressure fluctuation during interaction between the upstream vortical flow with the edge are studied numerically. The vortical flow is modeled by a point vortex, and the unsteady pressure coefficient is obtained from the velocity and the potential field. To investigate the effects of the edge shape the rectangular forward step is chamfered with various angles. Calculation show that the pressure peaks become decreased by increasing the vortex height as well as the chamfering angle. The pressure amplitudes are very sensitive to the change of the initial vortex height. From this study we can find out that the chamfered edge has two effects; the one is that it suppresses the pressure amplitude generated from the edge, and the other is that it decreases the time variation of unsteady pressure fluctuation. These modifying concepts can be applied to attenuate the self-sustained oscillation mechanism at the open cavity flow.

  • PDF

RESONANCE FREQUENCY ANALYSIS IN NON-SUBMERGED, INTERNAL TYPE IMPLANT WITH SINUS AUGMENTATION USING DEPROTEINIZED BOVINE BONE MINERAL (이종골을 이용한 상악동 측벽거상술과 동시 식립한 임프란트에서 안정성에 대한 공진 주파수 분석)

  • Lee, Ju-Hyon;Min, Hyun-Gi;Lee, Jin-Sook;Kim, Myung-Rae;Kang, Na-Ra
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.30 no.6
    • /
    • pp.554-560
    • /
    • 2008
  • In posterior maxilla, it is difficult to achieve primary stability of implants due to sinus pneumatization, alveolar bone loss, and low bone quality. The accurate and objective primary stability assessment is important for good prognosis of implants. Purpose: The aim of this study was to assess the primary stability of the non-submerged, internal type implants with maxillary sinus augmentation using deproteinized bovine bone mineral by a resonance frequency analyzer, when residual alveolar bone height is under 8mm Materials and methods: A total of 20 implants was placed into 5 grafted maxillary sinuses in 5 patients. Deproteinized bovine bone mineral (Bio-$Oss^{(R)}$) was used as graft material. SS II implants (diameter 4.1mm, and length 11.5mm, SLA suface)) were placed. All of the patients received maxillary sinus graft procedure by 1-step technique. Residual bone height was $1.3{\sim}7.8mm$ (mean 4.4mm) measured by panorama radiography. After implant placement, RFA was measured at 4,8,12,20 weeks. The results were divided into 2 groups; RFA value under 4mm and over 5mm of bone height. It was statistically analyzed. Results: 1. The primary stability of implants was increased with time 2. The RFA value was above 65 ISQ at 12 weeks 3. There was no correlation between RFA and residual alveolar bone height in maxillary sinus augmentation by 1-step technique. Conclusion: 1-step surgical procedure is a feasible option for patients with as little as 4mm residual alveolar bone height, when utilizing non-submerged, internal type implants with xenografts.

Effect of Wearing Ankle Weights on Underwater Treadmill Walking

  • Park, Que Tae;Kim, Suk Bum;O'Sullivan, David
    • Korean Journal of Applied Biomechanics
    • /
    • v.29 no.2
    • /
    • pp.105-112
    • /
    • 2019
  • Objective: The main purpose of this study was to investigate the effects of wearing an ankle weight belt while performing gait in water by focusing on the effect of using ankle weights have on the gait kinematics and the muscle activities for developing optimum training strategies. Method: A total of 10 healthy male university students were recruited for the study. Each participant was instructed to perform 3 gait conditions; normal walking over ground, walking in water chest height, and walking in water chest height while using ankle weights. All walking conditions were set at control speed of $4km/h{\pm}0.05km/h$. The depth of the swimming pool was at 1.3 m, approximately chest height. The motion capture data was recorded using 6 digital cameras and the EMG was recorded using waterproof Mini Wave. From the motion capture data, the following variables were calculated for analysis; double and single support phase (s), swing phase (s), step length (%height), step rate (m/s), ankle, knee, and hip joint angles ($^{\circ}$). From the electromyography the %RVC of the lower limb muscles medial gastrocnemius, rectus femoris, erector spinae, semitendinosus, tibialis anterior, vastus lateralis oblique was calculated. Results: The results show significant differences between the gait time, and step length between the right and left leg. Additionally, the joint angular velocities and gait velocity were significantly affected by the water resistance. As expected, the use of the ankle weights increased all of the lower leg maximum muscle activities except for the lower back muscle. Conclusion: In conclusion, the ankle weights can be shown to stimulate more muscle activity during walking in chest height water and therefore, may be useful for rehabilitation purposes.

Cusp Height in Circular Surface Machining Using Ball End Mill (볼엔드밀을 이용한 원호곡면의 가공시 CUSP의 크기)

  • Yoon, Hee-Jung;Park, Sang-Lyang;Choi, Jong-Soon;Park, Dong-Sam
    • Proceedings of the KSME Conference
    • /
    • 2000.04a
    • /
    • pp.826-830
    • /
    • 2000
  • Sculptured surface machining plays a vital role in the process of bring new Products to the market place. A great variety of products rely on this technology for the production of the dies and moulds used in manufacturing. And, the use or CNC machines and CAD/CAM system has become a vital parts or product development process. But, cusp is inevitable by-product in sculptured surface machining, and it is very difficult to calculate the cusp height correctly. In this study, an analytical cusp height model is proposed considering the radius of the ball end mill, radius of machined workpiece and the inclined angle of convex or concave circular surface. Experiments were performed to check the validity of this proposed model and experimental results showed that the proposed cusp model were very effective.

  • PDF