Browse > Article

RESONANCE FREQUENCY ANALYSIS IN NON-SUBMERGED, INTERNAL TYPE IMPLANT WITH SINUS AUGMENTATION USING DEPROTEINIZED BOVINE BONE MINERAL  

Lee, Ju-Hyon (Ewha Womans University School of Medicine Department of Oral and Maxillofacial Surgery)
Min, Hyun-Gi (Ewha Womans University School of Medicine Department of Oral and Maxillofacial Surgery)
Lee, Jin-Sook (Ewha Womans University Graduate School of Clinical Dentistry Department of lmplant Dentistry)
Kim, Myung-Rae (Ewha Womans University School of Medicine Department of Oral and Maxillofacial Surgery)
Kang, Na-Ra (Ewha Womans University School of Medicine Department of Oral and Maxillofacial Surgery)
Publication Information
Maxillofacial Plastic and Reconstructive Surgery / v.30, no.6, 2008 , pp. 554-560 More about this Journal
Abstract
In posterior maxilla, it is difficult to achieve primary stability of implants due to sinus pneumatization, alveolar bone loss, and low bone quality. The accurate and objective primary stability assessment is important for good prognosis of implants. Purpose: The aim of this study was to assess the primary stability of the non-submerged, internal type implants with maxillary sinus augmentation using deproteinized bovine bone mineral by a resonance frequency analyzer, when residual alveolar bone height is under 8mm Materials and methods: A total of 20 implants was placed into 5 grafted maxillary sinuses in 5 patients. Deproteinized bovine bone mineral (Bio-$Oss^{(R)}$) was used as graft material. SS II implants (diameter 4.1mm, and length 11.5mm, SLA suface)) were placed. All of the patients received maxillary sinus graft procedure by 1-step technique. Residual bone height was $1.3{\sim}7.8mm$ (mean 4.4mm) measured by panorama radiography. After implant placement, RFA was measured at 4,8,12,20 weeks. The results were divided into 2 groups; RFA value under 4mm and over 5mm of bone height. It was statistically analyzed. Results: 1. The primary stability of implants was increased with time 2. The RFA value was above 65 ISQ at 12 weeks 3. There was no correlation between RFA and residual alveolar bone height in maxillary sinus augmentation by 1-step technique. Conclusion: 1-step surgical procedure is a feasible option for patients with as little as 4mm residual alveolar bone height, when utilizing non-submerged, internal type implants with xenografts.
Keywords
Sinus graft; Implant; RFA;
Citations & Related Records
Times Cited By KSCI : 7  (Citation Analysis)
연도 인용수 순위
1 Szmukler-Moncler S, Salama H, Reingewirtz Y et al : Timing of loading and effect of micromotion on bone-dental implant interface: review of experimental literature. J Biomed Mater Res 43 : 192, 1998   DOI   ScienceOn
2 Barewal RM, Oates TW, Meredith N et al : Resonance frequency measurement of implant stability in vivo on implants with a sandblasted and acid-etched surface. Int J Oral Maxillofac Implants 18 : 641, 2003
3 da Cunha HA, Francischone CE, Filho HN et al : A comparison between cutting torque and resonance frequency in the assessment of primary stability and final torque capacity of standard and TiUnite single-tooth implants under immediate loading. Int J Oral Maxillofac Implants 19 : 578, 2004
4 Glauser R, Sennerby L, Meredith N et al : Resonance frequency analysis of implants subjected to immediate or early functional occlusal loading. Successful vs. failing implants. Clin Oral Implants Res 15 : 428, 2004   DOI   ScienceOn
5 Hallman M, Sennerby L, Lundgren S : A clinical and histologic evaluation of implant integration in the posterior maxilla after sinus floor augmentation with autogenous bone, bovine hydroxyapatite, or a 20:80 mixture. Int J Oral Maxillofac Implants 17 : 635, 2002
6 McDermott NE, Chuang SK, Woo VV et al : Maxillary sinus augmentation as a risk factor for implant failure. Int J Oral Maxillofac Implants 21 : 366, 2006
7 Friberg B, Sennerby L, Meredith N et al : A comparison between cutting torque and resonance frequency measurements of maxillary implants. A 20-month clinical study. Int J Oral Maxillofac Surg 28 : 297, 1999   DOI   ScienceOn
8 Yi YA, Cha IH, Lee HY et al : The influencing factors of $periotest^{\circledR}$ value and implant stability quentient. J Korean Acad Prosthodont 44 : 40, 2006   과학기술학회마을
9 Zix J, Kessler-Liechti G, Mericske-Stern R : Stability measurements of 1-stage implants in the maxilla by means of resonance frequency analysis: a pilot study. Int J Oral Maxillofac Implants 20 : 747, 2005
10 Nedir R, Bischof M, Szmukler-Moncler S et al : Predicting osseointegration by means of implant primary stability. Clin Oral Implants Res 15 : 520, 2004   DOI   ScienceOn
11 Al-Nawas B, Wagner W, Grotz KA : Insertion torque and resonance frequency analysis of dental implant systems in an animal model with loaded implants. Int J Oral Maxillofac Implants 21 : 726, 2006
12 Park C, Yim JH, Cho IH et al : A study on the measurement of the implant stability using resonance frequency analysis. J Korean Acad Prosthodont 41 : 182, 2003   과학기술학회마을
13 Piattelli M, Favero GA, Scarano A et al : Bone reactions to anorganic bovine bone (Bio-Oss) used in sinus augmentation procedures: a histologic long-term report of 20 cases in humans. Int J Oral Maxillofac Implants 14 : 835, 1999
14 Lee DH, Lee JH, Lee YS et al : Osseointegrated Implant. Seoul, Shinheoug International, 2002.-페이지 적어주세요
15 Piao CM, Kim SK, Koak JY et al: Effect of Implant designs on insertion toque and implant stability quotient(ISQ) value. J Korean Acad Prosthodont 44 : 325, 2006   과학기술학회마을
16 Kim SJ, Shin SW, Jung SM et al : A study on the stability of 5 different surface treatment methods to dental implant using resonance frequency and histomorphometric analysis J Korean Acad Prosthodont 43 : 78, 2005   과학기술학회마을
17 Albrektsson T, Sennerby L : Direct bone anchorage of oral implants: clinical and experimental considerations of the concept of osseointegration. Int J Prosthodont 3 : 30, 1990   PUBMED
18 Sykaras N, Triplett RG, Nunn ME et al : Effect of recombinant human bone morphogenetic protein-2 on bone regeneration and osseointegration of dental implants. Clin Oral Implants Res 12 : 339, 2001   DOI   ScienceOn
19 Balshi SF, Allen FD, Wolfinger GJ et al : A resonance frequency analysis assessment of maxillary and mandibular immediately loaded implants. Int J Oral Maxillofac Implants 20 : 584, 2005
20 Yi YJ, Park CJ, Cho LR : An evaluation of the primary implant stability and the immediate load-bearing capacity according to the change of cortical bone thickness J Korean Acad Prosthodont 43 : 248, 2005   과학기술학회마을
21 Meredith N : Assessment of implant stability as a prognostic determinant. Int J Prosthodont 11 : 491, 1998   PUBMED
22 Jaffin RA, Berman CL : The excessive loss of Branemark fixtures in type IV bone: a 5-year analysis. J Periodontol 62 : 2, 1991   DOI   PUBMED
23 Sennerby L, Meredith N : Implant stability measurements using resornance frequency analysis: biological and biomechanical aspects and clinical implications. Periodontol 2000 47 : 63, 2008
24 Bischof M, Nedir R, Szmukler-Moncler S et al : Implant stability measurement of delayed and immediately loaded implants during healing. Clin Oral Implants Res 15 : 529, 2004   DOI   ScienceOn
25 Tawil G, Mawla M : Sinus floor elevation using a bovine bone mineral (Bio-Oss) with or without the concomitant use of a bilayered collagen barrier (Bio-Gide): a clinical report of immediate and delayed implant placement. Int J Oral Maxillofac Implants 16 : 713, 2001
26 Peleg M, Mazor Z, Garg AK : Augmentation grafting of the maxillary sinus and simultaneous implant placement in patients with 3 to 5 mm of residual alveolar bone height. Int J Oral Maxillofac Implants 14 : 549, 1999   PUBMED
27 Lee JH, Yang JH : A study on the correlation between implant stability values and initial insertion torque. J Korean Acad Prosthodont 44 : 314, 2006   과학기술학회마을
28 Choi JE, Suh KW, Lee IK et al : Bone response of three different surface implants : Histomorphometric, perio test value and resonance frequency analysis in beagle dogs. J Korean Acad Prosthodont 45 : 362, 2007   과학기술학회마을