• 제목/요약/키워드: steel bar joint

검색결과 74건 처리시간 0.022초

20db 정착길이를 가지는 SD700 갈고리철근과 확대머리철근의 정착성능 실험 (Anchorage performance tests of SD700 hooked bar and headed bar with a anchorage length of 20db)

  • 김호영;심혜정
    • 도시과학
    • /
    • 제7권2호
    • /
    • pp.21-27
    • /
    • 2018
  • With the increase of the skyscraper center, the development of large-diameter and high-strength reinforcing bars is being carried out to solve the dense reinforcement. In case of the steel reinforced concrete with a small cross section such as beam-column joints, the development length becomes short when straight bars are used. Therefore, it is possible to solve the problem that the development length becomes short by using the bearing strength of the hooked bar and headed bar. In this study, the exterior beam-column joint test of SD700 hooked bar and headed bar with anchorage length of 20db was conducted to extend the development length limitation of hooked bar and headed bar. As a result of the evaluation of the anchorage strength using the design equation by KCI, the average of the [measured value]/[predicted value] ratio was 1.31 for the hooked reinforcing bars. In the case of headed bars, the average of the [measured value]/[predicted value] ratio was 1.12. In addition, in order to compare the anchorage performance of the hooked bar and the headed bar, the measured values were divided by the square root of the compressive strength of the concrete to compare the anchorage strength. Under the same conditions, the anchorage strength of headed bars was 8.5% higher than the hooked bars.

철근콘크리트 보-기둥 접합부 철근의 뽑힘 평가 (Evaluation of Steel Pull-Out of Reinforced Concrete Beam-Column Joints)

  • 우재현;박종욱;김병일;이정윤
    • 콘크리트학회논문집
    • /
    • 제22권6호
    • /
    • pp.833-841
    • /
    • 2010
  • 이 연구에서는 5개의 철근콘크리트 보-기둥 접합부 실험을 분석하였다. 연구의 주목적은 접합부에 인접한 보의 소성힌지의 영향으로 인한 부착 감소로 발생하는 보 주인장철근 미끄러짐에 따른 접합부 내력 및 연성을 평가하는 것이다. 또한 보 주인장철근량을 변수로 하여 접합부 내력 및 연성에 미치는 영향을 평가하였다. 실험 결과에 의하면 접합부의 전단강도비 $V_{j1}/V_{jby}$가 감소할수록 인접한 보의 소성힌지의 변형률 침투현상은 증가하는 것으로 나타났다. 주인장철근의 미끄러짐은 구간별로 다르게 나타났으며 주인장철근 뽑힘 현상은 접합부 전단강도비 $V_{j1}/V_{jby}$와 관계없이 비슷하게 나타났다. 이것은 주인장철근 뽑힘 현상이 변형률 침투현상만이 아닌 인접한 보의 소성힌지의 축변형에도 영향을 받기 때문이다.

철근 콘크리트 기둥과 철골보의 합성구조 접합부 성능에 관한 연구 (Structural Behavior of Reinforced Concrete column and Steel beam Joints)

  • 이원규;신동대;송진규;정혜교;최완철
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 학회창립 10주년 기념 1999년도 가을 학술발표회 논문집
    • /
    • pp.575-578
    • /
    • 1999
  • The main objective of this study was to examine structural behavior of reinforced concrete column and steel beam joint. composite specimens about 3/4 of the actual beam column connection assembly were tested by applying cyclic load through actuators. Test variables include face bearing plate(FBP), extended face bearing plate(E-FBP), VIR, U-bar and sub beam. There is not much differenced between specimens with sub beam and without sub beam. Test results also show that the joint strength of test specimen is close to the predicted strength by ASCE guideline.

  • PDF

혼합구조로 이루어진 보-기둥 접합부의 구조적 거동 특성 (The Properties for Structural Behavior of Beam-Column Joint Consisting of Composite Structure)

  • 이승조;박정민;김화중
    • 한국강구조학회 논문집
    • /
    • 제12권4호통권47호
    • /
    • pp.445-455
    • /
    • 2000
  • 본 연구는 최근의 건설 환경 변화에 따른 여러 가지 제문제점들에 대한 구조적 측면에서의 대응책의 하나로서 새로운 구조 시스템 전개를 위해 이종구조부재로 구성된 보기둥 접합부 모델을 제안한 것이다. 본 연구에서는 장스팬 S보의 강성을 향상시키기 위해 S조의 단부를 RC조로 보강하여 강성 및 내력증대를 꾀하였으며, 이종구조 사이의 원활한 응력 전달을 목적으로 SRC조 단부의 보 주근은 U자형 갈고리 모양으로 정착하여 철골 플랜지에 용접 접합하였다. 일련의 실험을 통해 접합부 강성 및 내력 특성을 고찰하였고 본 접합부의 가능성을 제시하였다.

  • PDF

Effects of Steel Fiber Reinforcement and the Number of Hooked Bars at R/C Exterior Joints

  • Choi, Ki-Bong
    • KCI Concrete Journal
    • /
    • 제11권3호
    • /
    • pp.181-189
    • /
    • 1999
  • An experimental study was performed on the Pull-out behavior of 90-deg standard hooks from the exterior beam-column connections. the effects of the number of hooked bars and fiber reinforcement of the joint area were investigated with the following conclusions : (1) Under the pull-out action of hooked bars. the damage and cracking of joint area the number of hooks pulling out from a joint increases; (2) Substitution of the transverse column (confining) reinforcement with steel fibers at the joint region effectively reduces the extent of cracking in exterior joints caused by the pull-out of hooked bars; (3) The pull-out strength and post-peak ductility of hooked bars are adversely influenced by the increase in number of hooks pulling out from an exterior joint. Current hooked bar anchorage design guidelines may be improved by considering the effect of the number of hooked bars on anchorage conditions at the exterior joints; and (4) The strength and ductility of hooked bars under pull-out forces are positively influenced by substituting the conventional confining reinforcement of exterior joints with steel fibers . The application of steel fibers to the exterior joints is an effective technique for improving the anchorage conditions of hooked bars, and also for reducing the congestion of reinforcement in the beam-column connections.

  • PDF

Static analysis of a radially retractable hybrid grid shell in the closed position

  • Cai, Jianguo;Jiang, Chao;Deng, Xiaowei;Feng, Jian;Xu, Yixiang
    • Steel and Composite Structures
    • /
    • 제18권6호
    • /
    • pp.1391-1404
    • /
    • 2015
  • A radially retractable roof structure based on the concept of the hybrid grid shell is proposed in this paper. The single-layer steel trusses of the radially foldable bar structure are diagonally stiffened by cables, which leads to a single-layer lattice shell with triangular mesh. Then comparison between the static behavior between the retractable hybrid grid shell and the corresponding foldable bar shell with quadrangular mesh is discussed. Moreover, the effects of different structural parameters, such as the rise-to-span ratio, the bar cross section area and the pre-stress of the cables, on the structural behaviors are investigated. The results show that prestressed cables can strengthen the foldable bar shell with quadrangular mesh. Higher structural stiffness is anticipated by introducing cables into the hybrid system. When the rise-span ratio is equal to 0.2, where the joint displacement reaches the minimal value, the structure shape of the hyrbid grid shell approaches the reasonable arch axis. The increase of the section of steel bars contributes a lot to the integrity stiffness of the structure. Increasing cable sections would enhance the structure stiffness, but it contributes little to axial forces in structural members. And the level of cable prestress has slight influence on the joint displacements and member forces.

철근 가스압접공법 활성화를 위한 한국형 철근자동가스압접기 기술개발방향 (The developing direction of korean gas pressure welding machine)

  • 서덕석;송기준;황기태;유병택
    • 한국건축시공학회지
    • /
    • 제5권3호
    • /
    • pp.131-138
    • /
    • 2005
  • The study is focused on the settling the developing direction of korean gas pressure welding machine which can be applied in korean construction sites with moderate and high performance. Gas pressure welding is more economical and has good performances than other steel bar jointing methods, as arc welding and mechanical joint etc. Therefore in Japan, the gas pressure welding, which has less loss of steel bars and low performance of joints, when connecting the D29 and thicker steel bars, Is one of the typical connection of steel reinforcement. But in Korea, the gas pressure welding method is not widely used caused by the shortage of skilled workers, and this situation in Korea can not be solved in short period. The training of the skilled workers takes long period(around $6\~10$ years), and there is no certification system for gas pressure welding. So to activate the gas pressure welding in Korea, the development of the automatic gas pressure welding machine is necessary, which gives regular performance of the steel bar joints and can be operated by not sufficient skilled workers. The automatic gas pressure welding machine was developed in Japan, but this machine has many problems when applied in korean construction sites. Therefore, it is necessary to develop a korean automatic gas pressure welding machine to overcome this problems. To develop korean automatic gas pressure welding machine, the problems, which shows when applied in korean construction sites, need to be investigated. According to the investigation, counterproposals are presented for the pragmatical development of the korean automatic gas pressure welding machine.

철근트러스 압접 데크플레이트 바닥 구조의 설계 프로그램 (Design Program of Deck Plate Slab System with Non-welding Truss Type Reinforced Bar)

  • 윤명호;오상훈
    • 한국디지털건축인테리어학회논문집
    • /
    • 제8권1호
    • /
    • pp.57-64
    • /
    • 2008
  • There are many problems in present truss-deck slab system for example welding defect, segregation, water leakage, rust and tarnish etc. These problems may be caused by spot welding thin galvanized steel plate and lattice bar. The TOX Joining Systems is to join metal sheets of different material and thickness with and without coating or painting without adding heat or a joining part. Newly developed TOX-deck slab system using non-welding joint is free from above mentioned problems. The objects of this study are suggestion of design strength of TOX joint by experimental and statistical analyses and development of window based program to design the TOX-deck slab system.

  • PDF

Experimental study on two types of new beam-to-column connections

  • Ma, Hongwei;Jiang, Weishan;Cho, Chongdu
    • Steel and Composite Structures
    • /
    • 제11권4호
    • /
    • pp.291-305
    • /
    • 2011
  • The new structure consisting of continuous compound spiral hoop reinforced concrete (CCSHRC)column and steel concrete composite (SCC) beam has both the advantages of steel structures and concrete structures. Two types of beam-to-column connections applied in this structural system are presented in this paper. The connection details are as follows: the main bars in beam concrete pass through the core zone for both types of connections. For connecting bar connection, the steel I-beam webs are connected by bolts to a steel plate passing through the joint while the top and bottom flanges of the beams are connected by four straight and two X-shaped bars. For bolted end-plate connection, the steel I-beam webs are connected by stiffened extended end-plates and eight long shank bolts passing through the core zone. In order to study the seismic behaviour and failure mechanisms of the connections, quasi-static tests were conducted on both types of full-scale connection subassemblies and core zone specimens. The load-drift hysteresis loops show a plateau for the connecting bar connection while they are excellent plump for bolted end-plate connection. The shear capacity formulas of both types of connections are presented and the values calculated by the formula agree well with the test results.

반복하중을 받는 외부 보-기둥 접합부에 정착된 57mm 확대머리철근의 정착성능평가 (Evaluation on Anchorage Performance of 57mm Headed Bars in Exterior Beam-Column Joint under Cyclic Loading)

  • 정형석;정주홍;최창식;배백일;최현기
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제25권6호
    • /
    • pp.68-75
    • /
    • 2021
  • 본 연구에서는 반복하중을 받는 외부 보-기둥 접합부에 정착된 57mm 확대머리철근의 정착성능을 평가하였다. 총 4개의 외부 보-기둥 접합부 실험체를 계획하였으며, 콘크리트 압축강도, 측면피복두께, 횡보강근비 및 파괴유형을 주요 실험 변수로 설정하여 정착성능평가를 수행하였다. 성능평가 결과, 접합부에 정착된 대구경 확대머리철근의 정착성능에 가장 큰 영향을 주는 요소는 측면피복두께 및 횡보강근으로 나타났으며, 외부 보-기둥 접합부에 정착된 57mm 대구경 확대머리철근은 반복하중하에서도 충분한 정착성능이 발현되는 것을 확인할 수 있었다.