• 제목/요약/키워드: steam and hot water supply

검색결과 9건 처리시간 0.021초

기존 사무소 건물 및 설비전문가 조사를 통한 설비시스템의 변화와 전망에 대한 연구 (A Study on the Transition & Expectation through Survey for Existing Building and Engineer's Opinion)

  • 이관호;김남규;박진철;이언구
    • 한국태양에너지학회 논문집
    • /
    • 제25권2호
    • /
    • pp.63-69
    • /
    • 2005
  • This study is the survey of a transition procedure of building services systems(heat source, HVAC, water supply) through the survey of existing office buildings, building design documents. The preference & major consideration of system selection is the engineer's opinions. The results of this survey can be used in selection of building services system design. In this survey, "Hot & cold water generator system" and "single duct CAV+FCU system", "Elevated water tank system" are selected. The most important consideration in system selection is the energy saving in heat source system, and comfort in HVAC system, and water pressure in water supply system. They prefer "steam boiler+absorption chiller system" for heat source system, "steam boiler+ice thermal storage system", "hot & cold water generator system", "district heating+absorption chiller system" : "single duct CAV+FCU system" and "single duct VAV+convector system" for HVAC system: and "booster pump system" for water supply system.

제 2종 LiBr-H2O 흡수식 히트펌프의 운전 변수에 따른 성능 특성 수치 해석 (Effects of Operation Conditions on the Performance of Type II LiBr-H2O Absorption Heat Pump)

  • 윤준성;권오경;차동안;배경진;김인관;김민수;박찬우
    • 설비공학논문집
    • /
    • 제29권1호
    • /
    • pp.7-14
    • /
    • 2017
  • This study carried out a numerical analysis of the effects of hot waste water supply on the performance of a Type II absorption heat pump. There are two types of hot waste water supply, regular series flow and reverse series flow. Also it investigated the interaction between each type of flow and heat exchange solutions. As the effectiveness of heat exchange solutions increase, the steam generation and (COP) increase as well. If the effectiveness of a heat exchange solution is lower than 0.566, the steam generation rate of the reverse flow is lower than that of the regular series flow. A high effectiveness of heat exchange solution is therefore required to make a larger amount of steam in reverse series flow than with ordinary series flow. The COP difference between the two types of flow decreases with the increasing effectiveness of the heat exchange solution. Thus, a reverse flow type absorption heat pump can match the high steam generation rate and COP of the ordinary flow type when a highly effective heat exchange solution is applied.

발전소 온배수열 활용사업의 경제적 유인제도 연구 : 에너지균등화비용(LCOE) 분석을 중심으로 (A Study on the Incentive-based Strategies for Utilization of Thermoelectric Power Plant Hot Waste Water: Focusing on the Analysis of Levelized Cost of Energy(LCOE))

  • 남태섭;이관영;김경남
    • 에너지공학
    • /
    • 제25권1호
    • /
    • pp.29-42
    • /
    • 2016
  • 본 연구는 최근 정부의 에너지신산업 정책 중 하나인 발전소 온배수열 활용사업의 경제성을 분석하고, 동 사업의 활성화를 위한 정부의 경제적 유인 제도를 재구성하였다. LCOE 산출방법을 이용하여 발전소 온배수열 시스템의 경제성을 분석한 결과 현 수준에서는 기름보일러, 바이오매스, 발전소 보조증기보다 LCOE값이 높지만 지열 시스템과는 유사한 것으로 나타났다. 또한 온배수열 시스템의 LCOE 구성요인의 민감도를 측정한 결과, 열공급 거리에 가장 민감하게 반응하는 것으로 나타났다. 따라서 온배수열 활용사업을 확대시키기 위한 정부의 경제적 유인제도 구성 시 REC 가중치를 열공급 거리별로 차등 적용하는 것이 필요한 것으로 분석되었다.

온수, 증기 동시 발생형 가스엔진 열병합발전의 배열회수 특성: 100 kW급 모형 실험 (Heat Recovery from a 1 MW Class Gas Engine CHP System: 100 kW Class Model Test)

  • 안준;김혁주;최규성;송대석
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.345-350
    • /
    • 2008
  • The present study has been conducted to develop a heat recovery system for a 1 MW class gas engine based cogeneration system. In the cogeneration system, heat is recovered from two parts, which are jacket water and exhaust gas. The heat from the jacket water is recovered by a plate type heat exchanger and used for the room heating and/or hot water supply. The heat from the exhaust gas is used to generate steam. For both of the heat recovery devices, 1/5 scaled tests are performed and the data are compared to the conventional correlations for the design.

  • PDF

배열 이용형 흡수식 사이클 특성평가 (Characteristics Evaluation of Absorption Cycles using the Waste Heat)

  • 윤정인;권오경;문춘근
    • 태양에너지
    • /
    • 제18권4호
    • /
    • pp.23-32
    • /
    • 1998
  • Fuel cells supply electric power and heat at work, and their exhaust gas is comparatively clear. So they are in the limelight as one of the co-generation systems which behave friendly with the environment. Fuel cells discharge both steam and hot water. Accordingly, if we combine absorption heat pump driven by waste heat with fuel cells, we can construct an advanced energy conserving system. The purpose of this study is the objective for evaluating the possibilities of effectively utilizing waste heat of fuel cells as a heat source for the single and double effect absorption systems. Simulation studies on single and double effect absorption have been performed for water/lithium-bromide pair. The effectiveness of introducing a waste heat source of fuel cells is demonstrated. The result of this study showed that total efficiency was about 85% at rated operation and about 75% at 75% load operation. Absorption cycle moved to more strong concentration when fuel cell operated at 75% load.

  • PDF

복합건물(D-Cube City) 지역에너지 공급체계 최적화 (Optimization of the Community Energy Supply System for D-Cube City, Multi Purpose Building)

  • 이태원;김용기;이건우;이기봉;조동호
    • 대한기계학회논문집B
    • /
    • 제36권6호
    • /
    • pp.669-674
    • /
    • 2012
  • 최근에 준공된 디큐브시티는 사무용, 상업용, 숙박용 및 관람집회용 등 4개의 시설이 공존하는 복합건물이다. 이 건물에는 필요로 하는 전기와 증기, 온수 및 냉수를 공급하기 위해 구역형 에너지공급시스템(Community energy supply system)이 설치되었다. 다양한 건물설비를 효과적으로 운영하기 위해 건물에너지관리시스템(Building energy management system)의 설치를 검토하고 있다. 본 연구에서는 3개의 열병합발전시스템을 비롯하여 7대의 증기보일러, 2대의 중온수보일러와 2대의 흡수식냉동기 및 4대의 터보냉동기 등으로 구성되는 구역형 에너지공급시스템의 최적 운전 및 설계방법을 검토하였다. 결과로서 에너지 수요변화에 따른 구역형 에너지공급시스템의 최적 운전방법과 계절적 운전조건의 변화가 시스템의 경제성에 미치는 영향을 규명하였다. 또 시설별 규모에 따라 결정되는 에너지 수요가 건물 전체의 에너지 소비에 미치는 영향도 분석하였다.

집단에너지산업의 국민경제적 파급효과 분석 (The Economic Effects of Integrated-Energy Business : An Input-Output Analysis)

  • 한건택;김혜민;유승훈
    • 에너지공학
    • /
    • 제21권1호
    • /
    • pp.47-54
    • /
    • 2012
  • 정부는 에너지 절약시책의 일환으로 제1,2차 석유파동 후 1983년에 목동신시가지에 집단에너지 사업을 도입하였다. 이후 집단에너지산업의 공급규모는 꾸준히 증가추세를 보이고 있다. 이에 본 논문에서는 2009년도 산업연관표에 근거한 투입산출분석을 이용하여 집단에너지산업의 국민경제적 파급효과를 분석하고자 한다. 수요유도형 모형을 이용하여 집단에너지산업에서의 생산 혹은 투자가 다른 산업에 미치는 영향에 대하여 논의한다. 공급유도형 모형을 적용하여 집단에너지산업에서의 공급지장이 다른 산업에 미치는 효과에 대해 살펴본다. 레온티에프 가격모형을 이용하여 집단에너지산업의 가격 변동이 다른 산업의 산출물 가격에 미치는 영향에 대해 검토한다. 특히 집단에너지산업을 중심에 놓고 이를 외생화하여 분석하는 접근방법을 취했다. 분석 결과를 요약하자면, 집단에너지산업은 낮은 생산유발효과, 높은 공급지장효과, 낮은 물가파급효과, 낮은 전방연쇄효과, 낮은 후방연쇄효과를 가진다. 이러한 정량적 정보는 집단에너지산업을 위한 정책결정에 있어서 유용하게 활용될 수 있다.

에너지원별 가격조정의 물가파급효과 분석 (Analyzing the impact of increase in energy price on the general price level)

  • 임슬예;송태호;유승훈
    • 에너지공학
    • /
    • 제22권4호
    • /
    • pp.376-385
    • /
    • 2013
  • 에너지부문의 가격인상이 물가에 미치는 영향에 대해 정부, 공급자, 수용가 사이에 논란이 존재한다. 공급자는 만성적자 해소와 경영의 계속성을 근거로 에너지요금 인상을 추진하지만 이에대해 한편에서는 물가상승 우려로 인한 반대의 목소리도 있다. 이러한 배경하에서 본 논문은 주요 에너지원별 가격변동의 물가파급효과를 정량적으로 규명하고자 한다. 이를 위해 2011년 산업연관표에 근거한 투입산출 분석을 적용하여 석탄, 나프타, 휘발유, 등유, 경유, 중유, LPG, 전력, 도시가스, 증기 및 온수공급업 총 10개 에너지원별 물가파급효과를 분석한다. 물가파급효과분석을 위해 레온티에프 가격모형을 적용하였고 분석결과 에너지원별로 요금을 10% 인상할 경우, 전력부문이 0.2196%로 10개 에너지원 중 물가파급효과가 가장 높게 나타났다. 반면 등유는 0.0122%로 10개 에너지원 중 가장 낮은 물가파급효과를 보였다. 가장 낮은 물가파급효과를 보이는 등유에 비해 가장 높은 물가파급효과를 보였던 전력부문은 약 18배의 물가파급효과가 있는 것으로 분석되었다. 더 나아가 10개의 에너지원별 물가파급효과에 대해 최근 3년의 결과를 비교하였고, 각각의 에너지원별로 가격을 조정하여 국민경제 전체로는 물가중립을 유지하는 자료로 제시하였다.

환경산업연관표 2005를 이용한 산업부문의 이산화탄소(CO2) 배출 분석 (CO2 Emission Structure Analysis of Industrial Sector with Environmental Input-Output Table 2005)

  • 김윤경
    • 자원ㆍ환경경제연구
    • /
    • 제20권1호
    • /
    • pp.1-31
    • /
    • 2011
  • 본 논문에서는 우리나라의 2005년 환경산업연관표(76개의 내생부문, 21개의 에너지원)를 작성하고, 중간수요부문과 최종수요부문을 대상으로 중간투입액기준의 $CO_2$ 원단위, 열량기준의 $CO_2$ 원단위, 유발 $CO_2$ 발생량을 추정하고, 경제주체간 및 산업간의 상품생산과 흐름에 수반되는 에너지소비와 $CO_2$의 흐름을 분석하였다. $CO_2$ 원단위의 비교에 따르면 최종수요부문이 더 높은 열량을 갖는 에너지원을 사용하며, 중간수요부문이 환경친화 정도가 상대적으로 낮은 에너지원을 사용하여 동일 열량에 대해서 $CO_2$를 더 배출시키고 있다. 유발 $CO_2$ 발생량이 높은 산업은 화력발전($32.587CO_2-g$/원), 시멘트($10.370CO_2-g$/원), 도로운송($7.255CO_2-g$/원), 코크스 및 기타석탄제품($5.791CO_2-g$/원), 증기 온수공급업 수도($4.575CO_2-g$/원)이다. 높은 $CO_2$ 원단위의 산업들의 $CO_2$ 원단위를 저감시키는 것은 해당산업의 환경친화성을 높이는 것과 함께, 경제 전체의 환경친화성을 높인다. 더하여 선철 및 조강처럼 낮은 $CO_2$ 원단위를 갖지만 높은 영향력계수와 감응도계수를 갖는 산업의 $CO_2$ 원단위도 낮추어야 한다. 이 산업들은 다른 산업에게, 그리고 다른 산업으로부터 상대적으로 큰 영향을 받기 때문에 $CO_2$ 원단위가 낮더라도 환경친화성을 갖추어야 유발 $CO_2$ 발생량을 낮출 수 있다.

  • PDF