• Title/Summary/Keyword: stayed cable

Search Result 618, Processing Time 0.03 seconds

A Safety Assessment using Imprecise Reliability for Corrosion-damaged Steel Structure (불확실 신뢰도 기법을 이용한 부식된 강구조물의 안전도분석)

  • 조효남;최현호;선종완
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2004.04a
    • /
    • pp.267-274
    • /
    • 2004
  • Since there is a large variation in measurements of the thickness of corroded elements, the thickness of corroded elements are considered as imprecise elements. There is also a considerable degree of uncertainty in a visual assessment of thickness loss. The remaining thickness of a severly corroded element may be represented by an imprecise which expresses the range over which there is uncertainty about the thickness. Therefore, the objective of this paper is to propose a new methodology to safety assessment using imprecise reliability into conventional safety assessment frameworks. For this purpose, this study presents a safety assessment model using Imprecise reliability for large civil structures and demonstrates the applicability of the approach to cable-stayed bridge projects.

  • PDF

Linear and Nonlinear Wave Pressure Distributions Acting on Vertical Caisson of Large Size in 3-Dimensional Wave Fields (3차원파동장에 있어서 대형연직케이슨에 작용하는 선형 및 비선형의 파압분포특성에 관한 연구)

  • 김도삼;신동훈;이봉재
    • Journal of Ocean Engineering and Technology
    • /
    • v.15 no.3
    • /
    • pp.114-119
    • /
    • 2001
  • Goda formula (Goda, 1973) has been used in the determination of wave pressures acting on a large size caisson such as the pier of the cable stayed bridge at sea. Goda formula, however, is to evaluate the wave pressures acting the infinite vertical caisson of composite breakwater so that it can`t be applied to a large caisson with finite width and length because of diffraction effects. In the present study, three dimensional nonlinear frequence domain method based on perturbation method and boundary integral method is applied to the computation of the linear and nonlinear wave pressures acting on the front of a large size caisson under the variation of its width and length, and angle of incident wave. The numerical results are compared to Goda\`s ones, and then the characteristics of wave pressure distributions acting on a large size caisson are discussed.

  • PDF

Bridge Health Monitoring with Consideration of Environmental Effects

  • Kim, Yuhee;Kim, Hyunsoo;Shin, Soobong;Park, Jong-Chil
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.6
    • /
    • pp.648-660
    • /
    • 2012
  • Reliable response measurements are extremely important for proper bridge health monitoring but incomplete and unreliable data may be acquired due to sensor problems and environmental effects. In the case of a sensor malfunction, parts of the measured data can be missing so that the structural health condition cannot be monitored reliably. This means that the dynamic characteristics of natural frequencies can change as if the structure is damaged due to environmental effects, such as temperature variations. To overcome these problems, this paper proposes a systematic procedure of data analysis to recover missing data and eliminate the environmental effects from the measured data. It also proposes a health index calculated statistically using revised data to evaluate the health condition of a bridge. The proposed method was examined using numerically simulated data with a truss structure and then applied to a set of field data measured from a cable-stayed bridge.

A parametric analysis of the flutter instability for long span suspension bridges

  • Como, M.;Ferraro, S. Del;Grimaldi, A.
    • Wind and Structures
    • /
    • v.8 no.1
    • /
    • pp.1-12
    • /
    • 2005
  • A simplified analysis able to point out the most relevant geometrical and aerodynamic parameters that can influence the flutter of long span modern bridges is the aim of the paper. With this goal, by using a continuous model of the suspension bridge and by a quasi stationary approach, a simple formula of the combined vertical/torsional flutter wind speed is given. A good agreement is obtained comparing the predictions from the proposed formula with the flutter speeds of three modern suspension or cable stayed bridges: the Great Belt East Bridge, the Akashi and Normandie bridges. The paper ends with some comments and comparisons with the well known Selberg formula.

An Intelligent bridge with an advanced monitoring system and smart control techniques

  • Miyamoto, Ayaho;Motoshita, Minoru
    • Smart Structures and Systems
    • /
    • v.19 no.6
    • /
    • pp.587-599
    • /
    • 2017
  • This paper introduces an approach to the realization of an ICT-based bridge remote monitoring system that enables real-time monitoring and controlled adjustments for unexpected heavy loads and also for damaging earthquakes or typhoons. In this paper, an integrated bridge remote monitoring system called the "Intelligent Bridge", which consists of a stand-alone monitoring system (SMS) and a web-based Internet monitoring system(IMS), was developed for not only bridge maintenance but also as an application for a para-stressing bridge system. To verify the possibility of controlling the actual structural performance of an "Intelligent Bridge", a model 2-span continuous cable-stayed bridge with adjustable cables was constructed. The experimental results demonstrate that the implemented monitoring system supplies detailed and accurate information about bridge behaviour for further evaluation and diagnosis, and it also opens up prospects for future application of a web-based remote system to actually adjust in-service bridges under field conditions.

Minimum Thickness of the Plate Member for UHPC Deck (초고성능콘크리트 바닥판 판부재의 최소두께)

  • Hwang, Hoon-Hee;Yoo, Dong-Min;Park, Sung-Yong;Kim, Byung-Suk
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.123-124
    • /
    • 2009
  • This research is a part of the comprehensive research project to develop the optimized UHPC precast deck system applying to durable and cost-effective hybrid cable stayed bridge. Longitudinally prestressed ribbed section is proposed to make the best use of a advantage of the ultra high performance concrete and the design concept is presented to decide the sectional property.

  • PDF

A Study on Base Isolation Performance of MR Dampers Using Clipped-Optimal Control (Clipped-Optimal Control을 사용한 MR 감쇠기의 면진성능에 관한 연구)

  • 고봉준;이종세
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2003.04a
    • /
    • pp.529-536
    • /
    • 2003
  • As large structures such as high-rise buildings and cable-stayed bridges become lighter and more flexible, the necessity of structural control for reducing excessive displacement and acceleration due to seismic excitation is increased. As a method to minimize seismic damages, various base isolation systems are adopted or considered for adoption. In this study, the seismic performance of MR dampers are studied and compared with that of the NZ system as a base isolation system. As the control algorithm of the MR damper, the clipped-optimal control(applied LQR method) is employed. A five-story building is modeled and the seismic performance of the two systems subjected to three different earthquakes is compared. The results show that the MR damper system can provide superior protection than the NZ system for a wide range of ground motions.

  • PDF

Design & Construction of PSC Box-Girder Bridge with Central Suspension by Extradosed Cables and Constant Girder Depth (중앙일면식 케이블과 등형고를 갖는 Extradosed PSC 교량의 설계 및 시공)

  • 조의경;김성일;박종화;이수열
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.618-625
    • /
    • 2003
  • The recent development of PSC girder bridges are mostly dedicated for optimization of self-weight, simplification of girder section for easy construction and minimization of maintenance efforts. Moreover some of those bridges are required as a landmark facility which raises the image of locality and harmony with surroundings. An extradosed bridge is one of the best alternates which not only covers the longer span than PSC box girder and also performs the role of landmark facility with much cheaper cost than cable stayed bridge. Hyundai is carrying out the construction of unique style extradosed bridge which have central suspension system and uniform girder depth named Keong-An grand bridge on the Sungnam-Janghowon Express highway. In this paper, major process of design and construction features of Keong-An bridge is presented.

  • PDF

Dynamic response of a bridge deck with one torsional degree of freedom under turbulent wind

  • Foti, Dora;Monaco, Pietro
    • Wind and Structures
    • /
    • v.3 no.2
    • /
    • pp.117-132
    • /
    • 2000
  • Under special conditions of turbulent wind, suspension and cable-stayed bridges could reach instability conditions. In various instances the bridge deck, as like a bluff body, could exhibit single-degree torsional instability. In the present study the turbulent component of flow has been considered as a solution of a differential stochastic linear equation. The input process is represented by a Gaussian zero-mean white noise. In this paper the analytical solution of the dynamic response of the bridge has been determined. The solution has been obtained with a technique of closing on the order of the moments.

Structural Parameter Estimation of Bridges Using Neural Networks (신경망을 사용한 교량구조의 미지계수 추정)

  • 방은영;윤정방
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1995.10a
    • /
    • pp.95-102
    • /
    • 1995
  • Procedures for estimation of axial or flexural rigidities of bridge members by neural networks are shown. To treat large scale structures containing many unkwon parameters, substructuring concept is introduced. The measurement points are selected considering the sensitivity of the element stiffnesses of interest. Utilization of relative mode vectors is found to be very effective for the local parameter estimation. Then, the study focuses on the method to obtain the training set enough to represent structures. It is shown that noise injection is effective to reduce the estimation errors caused by measurement noise. Verification of the present method is carried out using a cable-stayed bridge model.

  • PDF