• 제목/요약/키워드: stator coil

검색결과 159건 처리시간 0.037초

영구 자석 Halbach 배열 가동자로 구성된 철심형 직선 영구자석 동기 전동기의 특성 해석 (Characteristic Analysis of Permanent Magnet Linear Synchronous Motor with Halbach Array and Iron Core)

  • 장석명;유대준;이성호;장원범;권정기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.72-74
    • /
    • 2003
  • This paper presents a design and analysis solutions for the general class of iron-cored permanent magnet linear synchronous motor with Halbach (PMLSM). In our design and analysis, rotor consisting of permanent magnets rotor and slot less iron-cored coil stator are treated in a uniform way via vector potential. For one such motor structure, we give analytical formulas for its magnetic field, back electromotive force, inductance of winding coil, and trust force. We also provide performance comparisons of three types according to iron-cored and PM array.

  • PDF

인버터 구동 유도전동기의 코일과 턴에서의 전압 분포 연구 (A Study of Voltage Distribution on Coils and Turns in Inverter Fed Induction Motor)

  • 권병훈;안정렬;전태원;김흥근;노의철
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 추계학술대회 논문집
    • /
    • pp.112-114
    • /
    • 2007
  • The voltage stress on line-end coil of the stator winding in the induction motor fed by a PWM inverter is analyzed, using the computer model based on multi-conductors transmission line. A method to calculate circuit parameters, especially, capacitance between the turns and ground is proposed. The voltage distributions inside coil at motor terminal depending on dv/dt are investigated through simulation studies.

  • PDF

Electromagnetic design of 10 MW class superconducting wind turbine using 2G HTS wire

  • Kim, J.H.;Kim, H.M.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제15권3호
    • /
    • pp.29-34
    • /
    • 2013
  • This paper introduces design processes of 10 MW class superconducting generator for wind Turbine. Superconducting generator can produce 5 times stronger magnetic field than permanent magnet at least, which enables large scale wind turbine to function as a lighter, smaller and more highly efficient system. These processes are targeted for higher efficiency and shorter high temperature superconductor (HTS) wires to fabricate 10 MW class superconducting generator. Three different approaches will be described in these design processes. First design process focuses on the number of rotor poles. Secondly, 270 and 360 A operating current of superconducting field coil can be adapted as a design parameter in this process. Lastly, 3 and 6 kV line to line voltage of stator coil will be used to design 10 MW class superconducting generator.

내충격 성능을 고려한 함정용 하이브리드 마운트의 설계 (Design of Hybrid Mount to Naval Shipboard Considering Shock Resistance)

  • 조혜영;신윤호;문석준;정우진
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 추계학술대회 논문집
    • /
    • pp.102-107
    • /
    • 2012
  • In this study, the design procedure of hybrid active mount by an electro-magnetic actuator is proposed to reduce the transmitted force from naval shipboard equipment to ship hull structure. The hybrid type mount which is composed of a passive rubber element and an electro-magnetic actuator is introduced and, through the vibration measurement for the objective pump system, the required force of the actuator is computed and discussed in detail. The initial designs were supposed for three types, one is moving coil type actuator and the others are moving permanent magnet type actuators. Based on the initial design concept, the final designs considering shock resistance and interference with mover and stator are proposed and examined.

  • PDF

Push/pull 효과를 고려한 Springless LOA 구동드라이버 개발 (Springless LOA Driver Development with Consideration of Push/pull effect)

  • 장석명;권철;정상섭;성소영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.653-655
    • /
    • 2000
  • A moving-coil-type linear oscillatory actuator(LOA) consists of the NdFeB permanent magnets with high specific energy as the stator. a coil-wrapped nonmagnetic hollow rectangular structure. LOA system have the push/pull effect caused by the unbalanced magnetic field. In order to eliminate the unbalanced thrust, we propose the control algorithm and construct the LOA driver. As a results, we obtain the balanced oscillating thrust.

  • PDF

Analysis on the Switching Surge Characteristics of a High-Voltage Induction Motor Fed by PWM Inverter Using EMTP

  • Kim Jae-Chul;Song Seung-Yeop;Lee Do-Hoon
    • KIEE International Transactions on Power Engineering
    • /
    • 제5A권1호
    • /
    • pp.22-30
    • /
    • 2005
  • The PWM inverter drive may cause an over voltage at the motor terminal, which imposes severe electric stresses on the inter-turn insulation of motor windings. Unlike low-voltage induction motors, high-voltage induction motors have a stator type of form-wound coil for insulation and are insulated to the slot and the coil. So, this paper presents a PWM 3-level inverter, H-Bridge cascaded 7-level inverter and High-voltage induction motor model. It then analyzes the voltage that generates at the input terminal of the high-voltage induction motor fed by each inverter. Also, in order to examine a factor that influences the switching surge voltage, this paper proposes the system equivalent model and performs the case studies using EMTP.

양측 여자형 LDM의 다권선화에 관한 연구 (A study with multi-winding of double excited type LDM)

  • 이승명;백수현;김용;윤신용;맹인재
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 B
    • /
    • pp.290-293
    • /
    • 2000
  • In this paper, by designing the width of the stator coil, double sided excitation LDM with multi-separated winding which is possible to obtain the constant thrust force is proposed. Using Permeance method, equvalent magnetic circuit method, Maxwell 2D, which is the magnetic field analysis package, we were analyzed and proved the validity of design process, also the characteristics of LDM according to magnet vs. coil width ratio of LDM was almost in accord with the experiment results.

  • PDF

Test Result Analysis of a 1MW HTS Motor for Industry Application

  • Baik, S.K.;Kwon, Y.K.;Kim, H.M.;Lee, E.Y.;Kim, Y.C.;Park, H.J.;Kwon, W.S.;Park, G.S.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제11권2호
    • /
    • pp.33-36
    • /
    • 2009
  • A 1 MW class HTS (High-Temperature Superconducting) synchronous motor has been developed. This motor is aimed to be utilized for industrial application such as large motors operating in large plants. The HTS field coil of the developed motor is cooled by way of neon thermo siphonmechanism and the stator (armature) coil is cooled by water through hollow copper conductor. This paper also describes evaluation of some electrical parameters from performance test results of our motor, which was conducted at steady state in generator mode and motor mode. Open and short circuit tests were conducted in generator mode while a 1.1 MW rated induction machine was rotating the HTS machine. Electrical parameters such as mutual inductance and synchronous inductance are deduced from these tests. Load test was done upto rating torque during motor mode and efficiency was measured at each load torque.

고압전동기 모델 코일에서 부분방전 분석 (Analysis of Partial Discharge in High Voltage Motor Model Coils)

  • 김희동
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권4호
    • /
    • pp.178-182
    • /
    • 2006
  • Five model coils of 6.6 kV motor were manufactured with several defects. These stator coils have artificial defects such as void of groundwall insulation, removal of semi-conductive coating and damage of strand insulation. Epoxy-mica coupler(80 pF) was connected to five model coil terminals. The voltage applied to the coils was 3.81 kV, 4.76 kV, 6.0 kV and 6.6 kV, respectively. Partial discharge(PD) tests performed in the laboratory and shield room. Digital PD detector(PDD) and turbine generator analyzer(TGA) were used to measure PD activity. TGA summarizes each plot with two quantities such as the normalized quantity number(NQN) and the peak PD magnitude(Qm). The PD levels in pC were measured with PDD. PD patterns of model coils were indicated the internal and slot discharges. PD patterns are consistent with the result of measurement using PDD and TGA instruments. AC breakdown test was performed on five model coils in order to confirm the result of PD measurements. All the failures were located in a line-end coil at the exit from the core slot.

영구자석 매입형 유도동기전동기의 조립 후 착자에 대한 연rn (Study in Post-Assembly Magnetization of Line Start Permanent Magnet Motor)

  • 이철규;권병일
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권8호
    • /
    • pp.373-380
    • /
    • 2003
  • This paper consists of a study in post-assembly magnetization of LSPM (Line Start Permanent Magnet Motor). Recently, LSPM is noted as an alternative to the induction motor because it offers a very high efficiency and unity power factor, And it is necessary for permanent magnets to be magnetized by means of post-assembly magnetization in LSPMS because of the manufacturing cost involved. The manufacturing process is also simpler in post-assembly magnetization than in pre-assembly magnetization. Generally, permanent magnet motors are magnetized by their own stator coil or by magnetizing fixtures. However, the permanent magnet in a LSPM is scarcely magnetized by using them because of the eddy current of the rotor bar. Hence, it is necessary to design a magnetizing fixture that overcomes this problem. In this paper, the author analyses the post-assembly magnetization of a LSPM and proposes a method for designing the magnetizing fixture. The method that the author proposes is to make the number of coil turns greater in order to reduce the effect of the eddy current of the rotor bars.