• Title/Summary/Keyword: statistical parameter

Search Result 1,401, Processing Time 0.029 seconds

Evaluation for Optimization of CT Dose Reduction Methods in PET/CT (PET/CT 검사 시 CT 피폭선량 감소 방법들의 최적화 평가)

  • Do, Yong Ho;Lee, Hong Jae;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.2
    • /
    • pp.55-62
    • /
    • 2015
  • Purpose Various methods for reducing radiation exposure have been continuously being developed. The aim of this study is to evaluate effectiveness of dose reduction, image quality and PET SUV changes by applying combination of automatic exposure dose(AEC), automated dose-optimized selection of X-ray tube voltage(CAREkV) and sinogram affirmed iterative reconstruction(SAFIRE) which can be controled by user. Materials and Methods Torso, AAPM CT performance and IEC body phantom images were acquired using biograph mCT64, (Siemens, Germany) PET/CT scanner. Standard CT condition was 120 kV, 40 mAs. Radiation exposure and noise were evaluated by applying AEC, CAREkV(120 kV, 40 mAs) and SAFIRE(120 kV, 25 mAs) with torso phantom compare to standard CT condition. And torso, AAPM and IEC phantom images were acquired with combination of 3 methods in condition of 120 kV, 25 mAs to evaluate radiation exposure, noise, spatial resolution and SUV changes. Results When applying AEC, CTDIvol and DLP were decreased by 50.52% and 50.62% compare to images which is not applying AEC. mAs was increased by 61.5% to compensate image quality according to decreasing 20 kV when applying CAREkV. However, CTDIvol and DLP were decreased by 6.2% and 5.5%. When reference mAs was the lower and strength was the higher, reduction of radiation exposure rate was the bigger. Mean SD and DLP were decreased by 2.2% and 38% when applying SAFIRE even though mAs was decreased by 37.5%(from 40 mAs to 25 mAs). Combination of 3 methods test, SD decreased by 5.17% and there was no significant differences in spatial resolution. And mean SD and DLP were decreased by 6.7% and 36.9% compare to 120 kV, 40 mAs with AEC. For SUV test, there was no statistical differences(P>0.05). Conclusion Combination of 3 methods shows dose reduction effect without degrading image quality and SUV changes. To reduce radiation exposure in PET/CT study, continuous effort is needed by optimizing various dose reduction methods.

  • PDF

Evaluation of Standardized Uptake Value applying EQ PET across different PET/CT scanners and reconstruction (PET/CT 장비와 영상 재구성 차이에 따른 EQ PET을 이용한 표준섭취계수의 평가)

  • Yoon, Seok Hwan;Kim, Byung Jin;Moon, Il Sang;Lee, Hong Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.35-42
    • /
    • 2018
  • Purpose Standardized uptake value(SUV) has been widely used as a quantitative metric of uptake in PET/CT for diagnosis of malignant tumors and evaluation of tumor therapy response. However, the SUV depends on various factor including PET/CT scanner specifications and reconstruction parameter. The purpose of this study is to validate a EQ PET to evaluate SUV across different PET/CT systems. Materials and Methods First, NEMA IEC body phantom data were used to calculate the EQ filter for OSEM3D with PSF and TOF reconstruction from three different PET/CT systems in order to obtain EARL compliant recovery coefficients of each spheres. The Biograph true point 40 PET/CT images were reconstructed with a OSEM3D+PSF reconstruction, images of the Biograph mCT 40 and Biograph mCT 64 PET/CT scanners were reconstructed with a OSEM3D+PSF, OSEM3D+TOF, OSEM3D+PSF+TOF. Post reconstructions, the proprietary EQ filter was applied to the reconstruction data. Recovery coefficient can be estimated by ratio of measured to true activity concentration for spheres of different volume and coefficient variability(CV) value of RC for each sphere was compared. For clinical study, we compared SUVmax applying different reconstruction algorithms in FDG PET images of 61 patients with lung cancer using Biograph mCT 40 PET/CT scanner. Results For the phantom studied, the mean values of CV for OSEM3D, OSEM3D+PSF, OSEM3D+TOF and OSEM3D+PSF+TOF reconstructions were 0.05, 0.04, 0.04 and 0.03 respectively for RC. Application of the proprietary EQ filter, the mean values of CV for OSEM3D, OSEM3D+PSF, OSEM3D+TOF and OSEM3D+PSF+TOF reconstructions were 0.04, 0.03, 0.03 and 0.02 respectively for RC. Clinical study, there were no statistical significance of the difference applying EQ PET on SUVmax of 61 patients FDG PET image. (p=1.000) Conclusion This study indicates that CV values of RC in phantom were decreased after applying EQ PET for different PET/CT system and The EQ PET reduced reconstruction dependent variation in SUVs for 61 lung cancer patients, Therefore, EQ PET will be expected to provide accurate quantification when the patient is scanned on different PET/CT system.

Study on the Variation of Optical Properties of Asian Dust Plumes according to their Transport Routes and Source Regions using Multi-wavelength Raman LIDAR System (다파장 라만 라이다 시스템을 이용한 발원지 및 이동 경로에 따른 황사의 광학적 특성 변화 연구)

  • Shin, Sung-Kyun;Noh, Youngmin;Lee, Kwonho;Shin, Dongho;Kim, KwanChul;Kim, Young J.
    • Korean Journal of Remote Sensing
    • /
    • v.30 no.2
    • /
    • pp.241-249
    • /
    • 2014
  • The continuous observations for atmospheric aerosol were carried out during 3 years (2009-2011) by using a multi-wavelength Raman lidar at the Gwangju Institute of Science and Technology (GIST), Korea ($35.11^{\circ}N$, $126.54^{\circ}E$). The particle depolarization ratios were retrieved from the observations in order to distinguish the Asian dust layer. The vertical information of Asian dust layers were used as input parameter for the Hybrid Single Particle Lagrangian Integrated Trajectory (HYSPLIT) model for analysis of its backward trajectories. The source regions and transport pathways of the Asian dust layer were identified. The most frequent source region of Asian dust in Korea was Gobi desert during observation period in this study. The statistical analysis on the particle depolarization ratio of Asian dust was conducted according to their transport route in order to retrieve the variation of optical properties of Asian dust during long-range transport. The transport routes were classified into the Asian dust which was transported to observation site directly from the source regions, and the Asian dust which was passed over pollution regions of China. The particle depolarization ratios of Asian dust which were transported via industrial regions of China was ranged 0.07-0.1, whereas, the particle depolarization ratio of Asian dust which was transported directly from the source regions to observation site were comparably higher and ranged 0.11-0.15. It is considered that the pure Asian dust particle from source regions were mixed with pollution particles, which is likely to spherical particle, during transportation so that the values of particle depolarization of Asian dust mixed with pollution was decreased.

A Computed Tomography-Based Anatomic Comparison of Three Different Types of C7 Posterior Fixation Techniques : Pedicle, Intralaminar, and Lateral Mass Screws

  • Jang, Woo-Young;Kim, Il-Sup;Lee, Ho-Jin;Sung, Jae-Hoon;Lee, Sang-Won;Hong, Jae-Taek
    • Journal of Korean Neurosurgical Society
    • /
    • v.50 no.3
    • /
    • pp.166-172
    • /
    • 2011
  • Objective : The intralaminar screw (ILS) fixation technique offers an alternative to pedicle screw (PS) and lateral mass screw (LMS) fixation in the C7 spine. Although cadaveric studies have described the anatomy of the pedicles, laminae, and lateral masses at C7, 3-dimensional computed tomography (CT) imaging is the modality of choice for pre-surgical planning. In this study, the goal was to determine the anatomical parameter and optimal screw trajectory for ILS placement at C7, and to compare this information to PS and LMS placement in the C7 spine as determined by CT evaluation. Methods : A total of 120 patients (60 men and 60 women) with an average age of $51.7{\pm}13.6$ years were selected by retrospective review of a trauma registry database over a 2-year period. Patients were included in the study if they were older than 15 years of age, had standardized axial bone-window CT imaging at C7, and had no evidence of spinal trauma. For each lamina and pedicle, width (outer cortical and inner cancellous), maximal screw length, and optimal screw trajectory were measured, and the maximal screw length of the lateral mass were measured using m-view 5.4 software. Statistical analysis was performed using Student's t-test. Results : At C7, the maximal PS length was significantly greater than the ILS and LMS length (PS, $33.9{\pm}3.1$ mm; ILS, $30.8{\pm}3.1$ mm; LMS, $10.6{\pm}1.3$; p<0.01). When the outer cortical and inner cancellous width was compared between the pedicle and lamina, the mean pedicle outer cortical width at C7 was wider than the lamina by an average of 0.6 mm (pedicle, $6.8{\pm}1.2$ mm; lamina, $6.2{\pm}1.2$ mm; p<0.01). At C7, 95.8% of the laminae measured accepted a 4.0-mm screw with a 1.0 mm of clearance, compared with 99.2% of pedicle. Of the laminae measured, 99.2% accepted a 3.5-mm screw with a 1.0 mm clearance, compared with 100% of the pedicle. When the outer cortical and inner cancellous height was compared between pedicle and lamina, the mean lamina outer cortical height at C7 was wider than the pedicle by an average of 9.9 mm (lamina, $18.6{\pm}2.0$ mm; pedicle, $8.7{\pm}1.3$ mm; p<0.01). The ideal screw trajectory at C7 was also measured ($47.8{\pm}4.8^{\circ}$ for ILS and $35.1{\pm}8.1^{\circ}$ for PS). Conclusion : Although pedicle screw fixation is the most ideal instrumentation method for C7 fixation with respect to length and cortical diameter, anatomical aspect of C7 lamina is affordable to place screw. Therefore, the C7 intralaminar screw could be an alternative fixation technique with few anatomic limitations in the cases when C7 pedicle screw fixation is not favorable. However, anatomical variations in the length and width must be considered when placing an intralaminar or pedicle screw at C7.

Relationship Between Vascularity and Other Remodeling Parameters in Asthmatic Airway (기관지천식환자에서 기도내 혈관분포정도(vascularity) 및 다른 기도 재구성 소견과의 연관성)

  • Kim, Seung Joon;Lee, Sook Young;Kim, Myoung Sook;Lo, Dae Keun;Kwon, Soon Seog;Kim, Young Kyoon;Kim, Kwan Hyoung;Moon, Hwa Sik;Song, Jeong Sup;Park, Sung Hak
    • Tuberculosis and Respiratory Diseases
    • /
    • v.54 no.2
    • /
    • pp.191-198
    • /
    • 2003
  • Background : The pathological features in asthmatic airway remodeling are diverse. The aim of this study was to examine the degree of airway vascularity in relation to the other remodeling parameters in asthmatics. Methods : Bronchial biopsies were done in 34 asthmatic patients, and 6 control subjects. The basement membrane thickness and the subepithelial thickness were measured in the hematoxylin-eosin stained tissue, and the degree of vascularity was measured using type IV collagen immunostaining. Results : 1) Compared to the control subjects, the asthmatics showed a significant increase in the basement membrane thickness ($6.92{\pm}2.01{\mu}m$ vs $9.67{\pm}2.84{\mu}m$, p<0.05) and the subepithelial thickness ($44.49{\pm}31.92{\mu}m$ vs $121.22{\pm}72.79{\mu}m$, p<0.05). 2) Compared to the control subjects, the asthmatics showed a significant increase in the vascular area per unit submucosal area ($4.51{\pm}2.13%$ vs $10.32{\pm}6.08%$, p<0.05). In addition, the number of vessels per unit submucosal area showed an increased tendency without statistical significance. 3) In the asthmatics, the number of vessels and the vascular area per unit submucosal area showed no correlation with the basement membrane thickness, the subepithelial thickness, the severity, the forced expiratory volume in 1 second($FEV_1$), and the methacholine provocative concentration 20($PC_{20}$). Conclusion : This study showed that vascularity was an important parameter in asthmatic airway remodeling but it was not related to the other remodeling parameters such as the basement membrane thickness and the subepithelial thickness. Each of these asthmatic remodeling parameters may have a different clinical significance. Therefore, further studies will be needed.

Changes of the Preoperative and Postoperative Nutritional Statuses in Patients with Gastric Cancer and Assessment of the Nutritional Factors That Are Correlated with Short-Term Postoperative Complications (위암 환자에서 수술 전후의 영양지표의 변화와 수술 후 단기간 합병증과의 연관성)

  • Oh, Cheong-Ah;Kim, Dae-Hoon;Oh, Seung-Jong;Choi, Min-Gew;Noh, Jae-Hyung;Sohn, Tae-Sung;Kim, Sung;Bae, Jae-Moon
    • Journal of Gastric Cancer
    • /
    • v.10 no.1
    • /
    • pp.5-12
    • /
    • 2010
  • Purpose: The aim of this study was to evaluate the preoperative and postoperative nutritional statuses of patients with gastric cancer and to investigate the nutritional factors that are correlated with perioperative complications. Materials and Methods: From January 2008 to Jun 2008, 669 patients who underwent curative gastrectomy were enrolled in a retrospective study. To evaluate the changes of their nutritional status preoperatively and postoperatively, we measured the total lymphocyte count, the serum albumin, the body weight change and the BMI. The nutritional factors correlated with short-term postoperative complications were analyzed. Results: The total lymphocyte count and serum albumin decreased from the first preoperative day to the $5^{th}$ day after operation, but they tended to increase and approach the normal range 6 months after operation. The only factor correlated with the short-term postoperative complications (defined as the ones that occurred for 30 days) was the serum albumin checked on the $5^{th}$ day after operation. Conclusion: Low serum albumin on the $5^{th}$ day after operation was correlated with postoperative short-term complications. Serum albumin can be the preoperative statistical parameter that can predict the occurrence of postoperative complications.

The diagnostic significance of serum bile acid on total parenteral nutrition induced cholestasis in premature infants (총정맥영양에 의한 미숙아 담즙정체증에서 혈청 담즙산의 진단적 의의)

  • Park, Kyoung Soo;Shin, Myung Seok;Chang, Mea Young
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.8
    • /
    • pp.851-856
    • /
    • 2006
  • Purpose : The purpose of this study is to find out the diagnostic significance of serum bile acid on total parenteral nutrition induced cholestasis in premature infants. Methods : Infants without cholestasis were classified into postnatal days and each change of serum bile acid was measured and analyzed. Also, the serum direct bilirubin, serum bile acid, ${\gamma}$-glutamic acid transferase, and alkaline phosphatase of premature infants with total parenteral nutrition induced cholestasis were measured for comparison and analysis of their correlation. Results : Changes of serum bile acid analysis after birth showed no significant difference between boys and girls, between premature infants and term infants without cholestasis. Serum bile acid levels are constant after two weeks after birth in neonates without cholestasis. In premature infants with total parenteral nutrition induced cholestasis, the increase of serum direct bilirubin over 2 mg/dL was $34.9{\pm}18.3$ days after birth, and the increase of serum bile acid was $28.1{\pm}18.3$ days. Its increase was about 1 week faster than serum direct bilirubin, however, there was no statistical significance(P=0.114). Comparing analysis of serum bile acid, ${\gamma}$-glutamic acid transferase, and alkaline phosphatase, serum bile acid showed the highest correlation to serum direct bilirubin(r=0.487, P=0.000). Conclusion : Serum bile acid is an important parameter of total parenteral nutrition induced cholestasis in premature infants and will be useful for early diagnosis and treatment.

The Relationship Between Son Preference and Fertility (남아 선호와 출산력간의 관계)

  • 이성용
    • Korea journal of population studies
    • /
    • v.26 no.1
    • /
    • pp.31-57
    • /
    • 2003
  • This study is intended to examine (l)whether the value of son-for example, old age security and succession of family lineage- causing son preference in the traditional society can be explained at the individual level, (2)whether women without son in the son preference country continue her childbearing until having at least one son or give up the desire of having a son at a certain level. To accomplish these purposes, the 1974 Korean National Fertility Survey data are analyzed by the quadratic hazard models controlling unobserved heterogeneity. Unlike ordinary regression model, even omitted variables that affect hazard rates and are uncorrelated with the included independent variables can distort the parameter estimates in the hazard model. Therefore the nonparametric maximum likelihood estimator(NPMLE) of a mixing distribution developed by Heckman and Singer is used to control unobserved heterogeneity. Based on the statistical result in this study, the value of son causing son preference is determined at the societal level, not at the individual level. And Korean women without a son did not continue endlessly childbearing during child bearing ages until having a son. In general, they gave up the desire having a son when she had born six daughters continuously. Thus, 30-40 years ago, the number of daughters that women without a son giving up the desire of son was six, which is about the level of total fertility rate during 1960s. In these days, we can often see many women who have only two or three daughters and do not any son. This means that the level of giving up the desire of son, which is one factor representing the strength of son preference, becomes lower. If the strength of son preference did not become much weaker, then the fertility rates in Korea could not reach the below replacement level.

Comparison of Effectiveness about Image Quality and Scan Time According to Reconstruction Method in Bone SPECT (영상 재구성 방법에 따른 Bone SPECT 영상의 질과 검사시간에 대한 실효성 비교)

  • Kim, Woo-Hyun;Jung, Woo-Young;Lee, Ju-Young;Ryu, Jae-Kwang
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.9-14
    • /
    • 2009
  • Purpose: Nowadays in the nuclear medicine, many studies and efforts are being made to reduce the scan time, as well as the waiting time to be needed to execute exams after injection of radionuclide medicines. Several methods are being used in clinic, such as developing new radionuclide compounds that enable to be absorbed into target organs more quickly and reducing acquisition scan time by increase the number of Gamma Camera detectors to examine. Each medical equipment manufacturer has improved the imaging process techniques to reduce scan time. In this paper, we tried to analyze the difference of image quality between FBP, 3D OSEM reconstruction methods that commercialized and being clinically applied, and Astonish reconstruction method (A kind of Iterative fast reconstruction method of Philips), also difference of image quality on scan time. Material and Methods: We investigated in 32 patients that examined the Bone SPECT from June to July 2008 at department of nuclear medicine, ASAN Medical Center in Seoul. 40sec/frame and 20sec/frame images were acquired that using Philips‘ PRECEDENCE 16 Gamma Camera and then reconstructed those images by using the Astonish (Philips’ Reconstruction Method), 3D OSEM and FBP methods. The blinded test was performed to the clinical interpreting physicians with all images analyzed by each reconstruction method for qualitative analysis. And we analyzed target to non target ratio by draws lesions as the center of disease for quantitative analysis. At this time, each image was analyzed with same location and size of ROI. Results: In a qualitative analysis, there was no significant difference by acquisition time changes in image quality. In a quantitative analysis, the images reconstructed Astonish method showed good quality due to better sharpness and distinguish sharply between lesions and peripheral lesions. After measuring each mean value and standard deviation value of target to non target ratio with 40 sec/frame and 20sec/frame images, those values are Astonish (40 sec-$13.91{\pm}5.62$ : 20 sec-$13.88{\pm}5.92$), 3D OSEM (40 sec-$10.60{\pm}3.55$ : 20 sec-$10.55{\pm}3.64$), FBP (40 sec-$8.30{\pm}4.44$ : 20 sec-$8.19{\pm}4.20$). We analyzed target to non target ratio from 20 sec and 40 sec images. And we analyzed the result, In Astonish (t=0.16, p=0.872), 3D OSEM (t=0.51, p=0.610), FBP (t=0.73, p=0.469) methods, there was no significant difference statistically by acquisition time change in image quality. But FBP indicates no statistical differences while some images indicate difference between 40 sec/frame and 20 sec/frame images by various factors. Conclusions: In the circumstance, try to find a solution to reduce nuclear medicine scan time, the development of nuclear medicine equipment hardware has decreased while software has marched forward at a relentless. Due to development of computer hardware, the image reconstruction time was reduced and the expanded capacity to restore enables iterative methods that couldn't be performed before due to technical limits. As imaging process technique developed, it reduced scan time and we could observe that image quality keep similar level. While keeping exam quality and reducing scan time can induce the reduction of patient's pain and sensory waiting time, also accessibility of nuclear medicine exam will be improved and it provide better service to patients and clinical physician who order exams. Consequently, those things make the image of department of nuclear medicine be improved. Concurrent Imaging - A new function that setting up each image acquisition parameter and enables to acquire images simultaneously with various parameters to once examine.

  • PDF

A Knowledge-based Approach for the Estimation of Effective Sampling Station Frequencies in Benthic Ecological Assessments (지식기반적 방법을 활용한 저서생태계 평가의 유효 조사정점 개수 산정)

  • Yoo, Jae-Won;Kim, Chang-Soo;Jung, Hoe-In;Lee, Yong-Woo;Lee, Man-Woo;Lee, Chang-Gun;Jin, Sung-Ju;Maeng, Jun-Ho;Hong, Jae-Sang
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.16 no.3
    • /
    • pp.147-154
    • /
    • 2011
  • Decision making in Environmental Impact Assessment (EIA) and Consultation on the Coastal Area Utilization (CCAU) is footing on the survey reports, thus requires concrete and accurate information on the natural habitats. In spite of the importance of reporting the ecological quality and status of habitats, the accumulated knowledge and recent techniques in ecology such as the use of investigated cases and indicators/indices have not been utilized in evaluation processes. Even the EIA report does not contain sufficient information required in a decision making process for conservation and development. In addition, for CCAU, sampling efforts were so limited that only two or a few stations were set in most study cases. This hampers transferring key ecological information to both specialist review and decision making processes. Hence, setting the effective number of sampling stations can be said as a prior step for better assessment. We introduced a few statistical techniques to determine the number of sampling stations in macrobenthos surveys. However, the application of the techniques requires a preliminary study that cannot be performed under the current assessment frame. An analysis of the spatial configuration of sampling stations from 19 previous studies was carried out as an alternative approach, based on the assumption that those configurations reported in scientific journal contribute to successful understanding of the ecological phenomena. The distance between stations and number of sampling stations in a $4{\times}4$ km unit area were calculated, and the medians of each parameter were 2.3 km, and 3, respectively. For each study, approximated survey area (ASA, $km^2$) was obtained by using the number of sampling stations in a unit area (NSSU) and total number of sampling stations (TNSS). To predict either appropriate ASA or NSSU/TNSS, we found and suggested statistically significant functional relationship among ASA, survey purpose and NSSU. This empirical approach will contribute to increasing sampling effort in a field survey and communicating with reasonable data and information in EIA and CCAU.