• 제목/요약/키워드: statistical limits

검색결과 271건 처리시간 0.023초

시뮬레이션 출력비 추정량의 통계적 분석 (Statistical Analysis of Simulation Output Ratios)

  • 홍윤기
    • 한국시뮬레이션학회논문지
    • /
    • 제3권1호
    • /
    • pp.17-28
    • /
    • 1994
  • A statistical procedure is developed to estimate the relative difference between two parameters each obtained from either true model or approximate model. Double sample procedure is applied to find the additional number of simulation runs satisfying the preassigned absolute precision of the confidence interval. Two types of parameters, mean and standard deviation, are considered as the performance measures and tried to show the validity of the model by examining both queues and inventory systems. In each system it is assumed that there are three distinct means and their own standard deviations and they form the simultaneous confidence intervals but with control in the sense that the absolute precision for each confidence interval is bounded on the limits with preassigned confidence level. The results of this study may contribute to some situations, for instance, first, we need a statistical method to compare the effectiveness between two alternatives, second, we find the adquate number of replications with any level of absolute precision to avoid the unrealistic cost of running simulation models, third, we are interested in analyzing the standard deviation of the output measure, ..., etc.

  • PDF

On triple sequence space of Bernstein-Stancu operator of rough Iλ-statistical convergence of weighted g (A)

  • Esi, A.;Subramanian, N.;Esi, Ayten
    • Annals of Fuzzy Mathematics and Informatics
    • /
    • 제16권3호
    • /
    • pp.337-361
    • /
    • 2018
  • We introduce and study some basic properties of rough $I_{\lambda}$-statistical convergent of weight g (A), where $g:{\mathbb{N}}^3{\rightarrow}[0,\;{\infty})$ is a function statisying $g(m,\;n,\;k){\rightarrow}{\infty}$ and $g(m,\;n,\;k){\not{\rightarrow}}0$ as $m,\;n,\;k{\rightarrow}{\infty}$ and A represent the RH-regular matrix and also prove the Korovkin approximation theorem by using the notion of weighted A-statistical convergence of weight g (A) limits of a triple sequence of Bernstein-Stancu polynomials.

Statistical process control of dye solution stream using spectrophotometer

  • Lee, Won-Jae;Cho, Gyo-Young
    • Journal of the Korean Data and Information Science Society
    • /
    • 제21권6호
    • /
    • pp.1289-1303
    • /
    • 2010
  • The need for statistical process control to check the performance of a process is becoming more important in chemical and pharmaceutical industries. This study illustrates the method to determine whether a process is in control and how to produce and interpret control charts. In the experiment, a stream of green dyed water and a stream of pure water were continuously mixed in the process. The concentration of the dye solution was measured before and after the mixer via a spectrophotometer. The in-line mixer provided benefits to the dye and water mixture but not for the stock dye solution. The control charts were analyzed, and the pre-mixer process was in control for both the stock and mixed solutions. The R and X-bar charts showed virtually all of the points within control limits, and there were no patterns in the X-bar charts to suggest nonrandom data. However, the post-mixer process was shown to be out of control. While the R charts showed variability within the control limits, the X-bar charts were out of control and showed a steady increase in values, suggesting that the data was nonrandom. This steady increase in dye concentration was due to discontinuous, non-steady state flow. To improve the experiment in the future, a mixer could be inserted into the stock dye tank. The mixer would ensure that the dye concentration of the stock solution is more uniform prior to entering the pre-mixer ow cell. Overall, this would create a better standard to judge the water and dye mixture data against as well.

토모테라피에서 선량품질보증 분석을 위한 통계적공정관리의 타당성 (Feasibility on Statistical Process Control Analysis of Delivery Quality Assurance in Helical Tomotherapy)

  • 장경환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권6호
    • /
    • pp.491-502
    • /
    • 2022
  • The purpose of this study was to retrospectively investigate the upper and lower control limits of treatment planning parameters using EBT film based delivery quality assurance (DQA) results and to analyze the results of statistical process control (SPC) in helical tomotherapy (HT). A total of 152 patients who passed or failed DQA results were retrospectively included in this study. Prostate (n = 66), rectal (n = 51), and large-field cancer patients, including lymph nodes (n = 35), were randomly selected. The absolute point dose difference (DD) and global gamma passing rate (GPR) were analyzed for all patients. Control charts were used to evaluate the upper and lower control limits (UCL and LCL) for all the assessed treatment planning parameters. Treatment planning parameters such as gantry period, leaf open time (LOT), pitch, field width, actual and planning modulation factor, treatment time, couch speed, and couch travel were analyzed to provide the optimal range using the DQA results. The classification and regression tree (CART) was used to predict the relative importance of variables in the DQA results from various treatment planning parameters. We confirmed that the proportion of patients with an LOT below 100 ms in the failure group was relatively higher than that in the passing group. SPC can detect QA failure prior to over dosimetric QA tolerance levels. The acceptable tolerance range of each planning parameter may assist in the prediction of DQA failures using the SPC tool in the future.

지니(Gini)의 평균차이에 기초한 $\overline{X}$-관리도 (An $\overline{X}$-Control Chart Based on the Gini′s Mean Difference)

  • 남호수;강중철
    • 품질경영학회지
    • /
    • 제29권3호
    • /
    • pp.79-85
    • /
    • 2001
  • Estimation of the process deviation is an important problem in statistical process control, especially in the control chart, process capability analysis or measurement system analysis. In this paper we suggest the use of the Gini's mean difference for the estimation of the process deviation when we design the control limits in construction of the control charts. The efficiency of the Gini's mean difference was well explained in Nam, Lee and Jung(2000). In this paper we propose an $\overline{X}$ control chart which use the control limits based on the Gini's mean difference. In various classes of distributions, the proposed control chart shows food performance.

  • PDF

An Attempt to Model Distributions of Machined Component Dimensions in Production

  • Cogun, Can;Kilinc, Biinyamin
    • Journal of Mechanical Science and Technology
    • /
    • 제16권1호
    • /
    • pp.60-74
    • /
    • 2002
  • In this study, normal, log-normal, triangular, uniform. Weibull, Erlang and unit beta probability density functions are tried to represent the behaviour of frequency distributions of workpiece dimensions collected from various manufacturing firms. Among the distribution functions, the unit beta distribution function is found to be the best fit using the chi-square test of fit. An attempt is made for the adoption of the unit beta model to x-bar charts of quality control in manufacturing. In this direction, upper and lower control limits (UCL and LCL) of x-bar control charts of dimension measurements are estimated for the beta model, and the observed differences between the beta and normal model control limits are discussed for the measurement sets.

자세조절에 영향을 주는 연령대별 균형 안정성 한계에 관한 비교 (A Comparision of the Limits of Stability Associated with Aging)

  • 정동훈;권혁철
    • The Journal of Korean Physical Therapy
    • /
    • 제11권2호
    • /
    • pp.139-147
    • /
    • 1999
  • The purpose of this study was to evaluate and compare the limits of stability(LOS) data obtained from aged 20 to 69 years. In addition, this study was carried out to know correlation between age and LOS. 150 adults without neurosurgical and orthopedic disability from 20 to 69 years of age participared in this study. The LOS was measured at Two Feet Forceplate with BPM(Balance Performance Monitor) Dataprint Software Version 5.3. In this study applied the independent t-test, one-way ANOVA, and correlation analysis to determine the statistical significance of results at 0.05 level of significance. The results of this study were as follows: 1. The anteroposterior LOS significantly differented from 40 age group to 60 age group. 2. The mediolateral LOS significantly differencted from 50 age group to 60 age group. 3. There were statistically significant differences in anteroposterior LOS according to age increasing.

  • PDF

VSI EWIMA 관리도의 경제적 설계 (An Economic Design of the EWMA Control Charts with Variable Sampling Interval)

  • 송서일;정혜진
    • 품질경영학회지
    • /
    • 제30권4호
    • /
    • pp.1-14
    • /
    • 2002
  • Traditional SPC techniques are looking out variation of process by fixed sampling interval and fixed sample size about every hour, the process of in-control or out-of-control couldn't be detected actually when the sample points are plotted near control limits, and it takes no notice of expense concerned with such sample points. In this paper, to overcome that, consider VSI(variable sampling interval) EWMA control charts which VSI method is applied. The VSI control charts use a short sampling internal if previous sample points are plotted near control limits, then the process has high probability of out-of-control. But it uses a long sampling interval if they are plotted near centerline of the control chart, since process has high possibility of in-control. And then a comparison and analysis between FSI(fixed sampling interval) and VSI EWMA in the statistical aspect and economic aspect is studied. Finally, we show that VSI EWMA control chart is more efficient than FSI EWMA control chart in the both aspects.

4,500 TEU 컨테이너 운반선의 소음 제어 (Noise Control for 4,500 TED Container Carrier)

  • 김동해;임도형
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 II
    • /
    • pp.1313-1316
    • /
    • 2001
  • Generally, container carrier has larger engine than other commercial vessels and the engine casing is located in accommodation space. Therefore, the noise levels of cabins and engine room could be exceeded the specified noise limits and might be an annoyance to crews, and which can result in poor ship quality. Main subject of this study is to predict noise levels of the 4,500 TED container carrier by statistical energy analysis method in order to comply with contracted noise limits and to compare with the measured values. Additionally, through the contribution analysis of noise sources to each cabins, and appropriate countermeasures are proposed and the reduction effect of each noise control measure is studied by the analysis method. This study will contribute to reduce the noise levels of similar vessel.

  • PDF

작업자 무영향도출수준(worker-DNEL)의 사업장 적용을 위한 평가 연구 (Evaluation of the Application of worker-DNELs under REACH Guidance as Provisional Occupational Exposure Limits in the Workplace)

  • 윤영희;이석원;정현희;김관식
    • 한국산업보건학회지
    • /
    • 제23권1호
    • /
    • pp.27-34
    • /
    • 2013
  • Objectives: The purpose of this study is to calculate the worker-DNEL (Derived No Effect Level) values using the REACH guidance and compare the calculated DNELs with existing Korea occupational exposure limits (KOELs) for evaluation of the applicability of the worker-DNELs as provisional occupational exposure limits for chemicals that are not established KOELs in the workplace. Methods: The worker-DNELs for 46 chemicals among 113 hazardous substance requiring management were calculated using the REACH guidance, and a paired t-test was performed to see if there is any statistical difference between two lists (worker-DNELs vs KOELs). The ratios of KOELs over worker-DNELs were also calculated to compare the overall levels of two lists using the geometric means method. Results: The calculated worker-DNELs for 46 chemicals ranged from 0.001 to $329mg/m^3$ (GM= 6.9, GSD = 10.8), and appeared to be a significant difference between the worker-DNELs and the KOELs (p < 0.01). In addition, the ratios of KOELs over worker-DNELs ranged from 0.3 to 394 times (GM = 10.2, GSD = 3.9), indicating that the worker-DNELs were, on average, 27 times lower than the KOELs. Conclusions: Therefore, the study results show that the calculated worker-DNELs can be applied and used as provisional occupational exposure limits in the workplace in order to reduce worker exposures to chemicals and health risks, and manage potential worker exposures based on the precautionary principle through comprehensive chemical risk assessment.