• Title/Summary/Keyword: static scan

Search Result 70, Processing Time 0.022 seconds

A Study of Shirts' Patternmaking Based on 3D Body Surface Changes in Golf Swing Postures (골프 스윙 자세의 체표면 변화 특성을 반영한 셔츠 패턴 설계 연구)

  • Oh, Seol-Young;Chun, Jong-Suk
    • The Research Journal of the Costume Culture
    • /
    • v.19 no.5
    • /
    • pp.1049-1060
    • /
    • 2011
  • The purpose of this study was to develop a shirt pattern that enhances the functionality of golf swing motions. The pattern was made with 3D body surface shape data that changed according to dynamic golf postures. The data were collected from the golf swing motions. The 3D body surface data in golf swing postures piled up on the 3D surface data in a static posture. The results showed that the surface shape data changed more in the address, back swing, and finish postures than the other swing postures. The experimental pattern was developed with 3D surface scan data in those three golf swing motions. The pattern had raglan sleeves and the front-bodied piece was divided into two pieces with a princess line, which comes from armscye line of the address posture. The back bodice piece was divided into three pieces with a yoke line and a back princess line. The yoke line was made by back shoulder shape in the back swing posture. The level of comfort of the experimental garment and commercial golf shirts was evaluated by 38 women golfers. The experimental garment pattern was evaluated to be more comfortable in golf swing postures than commercial golf shirts.

Initial experience with intra-articular 188Re-tin colloid as a "radiation synovectomy" agent in various joints

  • Shinto, Ajit S;Indira, VU;Kamaleshwaran, KK;Banka, Vinay Kumar;Aswathy, KK;Thirumalaisamy, SG;Rajamani, V;Mallia, Madhav;Banerjee, Sharmila
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.1 no.2
    • /
    • pp.109-117
    • /
    • 2015
  • Radiation synovectomy has been proposed as a promising palliative therapy for recurrent joint effusions for the last two or three decades. Ionizing radiations emitted by intrarticularly administered radiolabelled colloids. The aim of this study was to assess the effectiveness of radiation synovectomy (RSV) using $^{188}Re$-tin colloid in the treatment of recurrent joint effusions and chronic synovitis of knee joints. Three phase bone scan was acquired for the concerned joint prior to radiosynovectomy. $^{188}Re$-tin colloid was prepared as per the reported protocol. 9 patients, diagnosed with rheumatoid arthritis and suffering from chronic resistant synovitis of the knee, ankle or elbow joints were administered the radiopharmaceuticals, checked for radiochemical purity >95% by intraarticular route. A whole body scan was acquired 2 h post-radiosynovectomy. In all the 9 treatments, no leakage to non-target organs was visible in the whole body scan. Static scans of the joint revealed complete retention of $^{188}Re$-tin colloid in the joints post administration of the agent. Clinically all patients exhibited a complete or partial response. RSV with $^{188}Re$-tin colloid was safe and effective in patients with chronic synovitis of rheumatoid origin.

Influence of Unilateral Muscle Fatigue in Knee and Ankle Joint on Balance and Gait in Healthy Adults

  • Lee, Na-Kyung;Kim, Young-Mi;Kim, Kyoung
    • The Journal of Korean Physical Therapy
    • /
    • v.29 no.1
    • /
    • pp.39-43
    • /
    • 2017
  • Purpose: This study was to investigate the effects of unilateral muscle fatigue in knee and ankle joints on balance and gait in healthy adults. Methods: Exercise inducing muscle fatigue in the knee joint consisted of concentric and eccentric contraction of dominant knee extensors in healthy adults by using the Leg Extension Rehap exercise machine (HUR, Finland). Exercise inducing muscle fatigue in the ankle joint was composed of voluntary contractions and forced contractions of the dominant plantar flexors in healthy adults. Exercises to induce muscle fatigue in the knee and ankle joints were performed until the subject complained of fatigue or pain, the occurrence of muscle fatigue was confirmed by electromyography. We measured static and dynamic balance using the Good Balance system and gait performance by RS-scan. Results: Static and dynamic balance ability and spatial-temporal gait decreased significantly after muscle fatigue in knee and ankle joint. Conclusion: These results show that unilateral muscle fatigue of the lower extremities affected postural control and gait. Therefore, therapists and sport trainers should minimize the risks of fall and injuries related to unilateral muscle fatigue.

A Flexure Guided Planar Scanner for Scanning Probe Microscope ; Part 2. Evaluation of Static and Dynamic Properties (주사 현미경용 평면 스캐너 Part 2 : 정 · 동 특성 평가)

  • Lee, Moo-Yeon;Gweon, Dae-Gab;Lee, Dong-Yeon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.11 s.104
    • /
    • pp.1295-1302
    • /
    • 2005
  • This paper shows experimental evaluation results of the nano-positioning planar scanner used in the scanning probe microscope. The planar scanner is composed of flexure guides, piezoelectric actuators and feedback sensors as like explained in detail in Ref. (5). First, the fabrication methods were explained. Second, as the static Properties of the Planar scanner. we evaluated the maximum travel range & crosstalk. Also, we presented the correcting method for crosstalk using electric circuits finally. as the dynamic properties of the planar scanner, we evaluated the first resonant frequency. Also, we presented the actual AFM(atomic force microscope) imaging results with up to 2Hz imaging scan rate. Experimental results show that properties of the proposed planar scanner are well enough to be used in SPM applications like AFM.

Usefulness of $^{99m}Tc$-labeled RBC Scan and SPECT in the Diagnosis of Head and Neck Hemangiomas (두경부 혈관종 진단시 $^{99m}Tc$-RBC Scan and SPECT 검사의 유용성)

  • Oh, Shin-Hyun;Roh, Dong-Wook;Ahn, Sha-Ron;Park, Hoon-Hee;Lee, Seung-Jae;Kang, Chun-Goo;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.1
    • /
    • pp.39-43
    • /
    • 2008
  • Purpose: There are various methods to diagnose hemangioma, such as ultrasonography (US), computed tomography (CT), magnetic resonance imaging (MRI) and nuclear medicine. However, by development of SPECT imaging, the blood-pool scan using $^{99m}Tc$-labeled red blood cell has been used, because it was non-invasive and the most economical method. Therefore, in this study, we proposed that the usefulness of $^{99m}Tc$-RBC scan and SPECT of the head and neck to diagnose unlocated hemangiomas. Materials and Methods: $^{99m}Tc$-RBC scan and SPECT was performed on 6 patients with doubtful hemangioma (4 person, head; 1 person, neck; 1 person, another). We labeled radiopharmaceutical using modified in vivo method and then, centrifuged it to remove plasma. After a bolus injection of tracer, dynamic perfusion flow images were acquired. Then, anterior, posterior, both lateral static blood-pool images were obtained as early and 4 hours delayed. SPECT was progressed 64 projections per 30 seconds. Each image was interpreted by physicians, Nuclear medicine specialist, and technologist blinded to patient's data. Results: In 5 patients of all the radioactivity of doubtful site didn't change in flow images, but, in blood-pool, delayed and SPECT images, it was increased. So, it was a typical hemangioma finding. The size of lesion was over 2 cm, and it could discriminate as comparing to the delayed and SPECT imaging. On the other hand, in 1 patient, the radioactivity was increased in blood-pool images, but, not in delayed and SPECT images, so, it was proved no hemangioma. Conclusion: Using $^{99m}Tc$-RBC Scan and SPECT, we could diagnose the hemangiomas in head and neck, as well as, liver, more non-invasive, economical, and easy. Therefore, it considered that $^{99m}Tc$-RBC scan and SPECT would offer more useful information for diagnosis of hemangioma, rather than otherimaging such as US, CT, MRI.

  • PDF

A Study on the Table Deflection by Stop State and Move Speed at Loaded Load (하중 게재시 정지상태 및 이송속도에 따른 테이블 처짐에 관한 연구)

  • 이지용;김태호;정영덕;박정보;김순경;전언찬
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1117-1122
    • /
    • 2003
  • The paper on table deflection by stop state and move speed at loaded load, and the table deflection measured of static load. It is developed program for Date correction of LSM(Least Square Method). We experimented the method as following. The first a Laser setting and scan Experimental device measured curvature radius, The second A center of measurement object and curvature radius taking of LSC.

  • PDF

Load Distribution Strategies for High Speed Ray-Tracing on Multiprocessors (고속 광선 추적법을 위한 멀티프로세서에서의 부하분산방식)

  • Gwon, O-Bong
    • The Transactions of the Korea Information Processing Society
    • /
    • v.6 no.5
    • /
    • pp.1362-1372
    • /
    • 1999
  • Ray-tracing algorithm can synthesize photo-realistic image, but its computational cost is high. Fast image synthesis based on ray-tracing is one of the most important topics in computer graphics. There are two methods for high speed ray-tracing. First this paper discusses various load distribution and scheduling of multiprocessor for high sped ray-tracing. Then this paper proposes load distribution strategies based on them, implements and evaluates it on multiprocessor. The experiment results show that the proposed method can solve the unbalanced load problem of dynamic load distribution, and scan line method and dot method among a kind of static load distribution strategies disperse the load efficiently.

  • PDF

High-speed Two-photon Laser Scanning Microscopy Imaging of in vivo Blood Cells in Rapid Circulation at Velocities of Up to 1.2 Millimeters per Second

  • Boutilier, Richard M.;Park, Jae Sung;Lee, Ho
    • Current Optics and Photonics
    • /
    • v.2 no.6
    • /
    • pp.595-605
    • /
    • 2018
  • The two-photon process of microscopy provides good spatial resolution and optical sectioning ability when observing quasi-static endogenous fluorescent tissue within an in vivo animal model skin. In order to extend the use of such systems, we developed a two-photon laser scanning microscopy system capable of also capturing $512{\times}512$ pixel images at 90 frames per second. This was made possible by incorporating a 72 facet polygon mirror which was mounted on a 55 kRPM motor to enhance the fast-scan axis speed in the horizontal direction. Using the enhanced temporal resolution of our high-speed two-photon laser scanning microscope, we show that rapid processes, such as fluorescently labeled erythrocytes moving in mouse blood flow at up to 1.2 mm/s, can be achieved.

Static and Fatigue Characteristics of Urethane Foam Cored Sandwich Structures (우레탄 폼 코아 샌드위치 구조물의 정적 및 피로 특성)

  • 김재훈;이영신;박병준;김덕회;김영기
    • Composites Research
    • /
    • v.12 no.6
    • /
    • pp.74-82
    • /
    • 1999
  • The static and fatigue characteristics of polyurethane foam cored sandwich structures are investigated. Three types of the specimens with the glass fabric faces and the polyurethane foam core are used; non-stitched. stitched, and stiffened sandwich specimen. Especially additional structural reinforcements with the twisted polyester and glass fiber for thickness direction are made to stitched sandwich structure panel to minimize the delamination of structure which is stitched the upper and lower faces through the core and the resin is impregnated Into stitched fiber with the characteristics of low viscosity of resin at resin flow temperature and cured together with during the curing process. Bending strength of stitched specimen which is 50 mm $50{\times}50{\;}mm$ pitched is improved by 50 % as com-pared with non-stitched specimen and stiffened specimen is improved 10 times more than non-stitched structure. After fatigue testing of $10^6$cycles by 20% of ultimate load under monotonic load, the bending fatigue strength of non-stitched specimen is decreased by 27% of monotonic bending strength, 39% for stitched structure and 20% for stiffened specimen. To verify the aging effect of polyurethane form core, Ultrasonic C-scanning equipment is used to detect the damage of skin laminate alone after fatigue test. From results of UT C-scan images, there is no defect that can be damaged occurred during fatigue test. It is concluded that the decrease of bending strength for foam cored sandwich specimen is caused by the decrease of stiffness due to the aging of polyurethane foam core during fatigue cycles.

  • PDF

Delay Fault Test Pattern Generator Using Indirect Implication Algorithms in Scan Environment (스캔 환경에서 간접 유추 알고리즘을 이용한 경로 지연 고장 검사 입력 생성기)

  • Kim, Won-Gi;Kim, Myeong-Gyun;Gang, Seong-Ho
    • The Transactions of the Korea Information Processing Society
    • /
    • v.6 no.6
    • /
    • pp.1656-1666
    • /
    • 1999
  • The more complex and large digital circuits become, the more important delay test becomes which guarantees that circuits operate in time. In this paper, the proposed algorithm is developed, which enable the fast indirect implication for efficient test pattern generation in sequential circuits of standard scan environment. Static learning algorithm enables application of a new implication value using contrapositive proposition. The static learning procedure found structurally, analyzes the gate structure in the preprocessing phase and store the information of learning occurrence so that it can be used in the test pattern generation procedure if it satisfies the implication condition. If there exists a signal line which include all paths from some particular primary inputs, it is a partitioning point. If paths passing that point have the same partial path from primary input to the signal or from the signal to primary output, they will need the same primary input values which separated by the partitioning point. In this paper test pattern generation can be more effective by using this partitioning technique. Finally, an efficient delay fault test pattern generator using indirect implication is developed and the effectiveness of these algorithms is demonstrated by experiments.

  • PDF