• Title/Summary/Keyword: static magnetic fields

Search Result 47, Processing Time 0.019 seconds

Effects of Static Magnetic Fields on Phagocytic Activity of Murine Peritoneal Macrophages

  • Eun, Jae-Soon;Ko, Dae-Woong;Jeon, Yong-Keun;Lee, Kyung-A;Park, Hoon;Ma, Tian-Ze;Kim, Min-Gul;Kwak, Yong-Geun
    • Biomolecules & Therapeutics
    • /
    • v.14 no.3
    • /
    • pp.152-159
    • /
    • 2006
  • Electro-magnetic fields and static magnetic fields generated from diverse home/environmental sources have been reported that these could make harmful effects on the human health such as suppression of immunity and tumorigenesis. However, the mechanisms for the biologic effects of electro-magnetic fields or static magnetic fields are still remained unclear. In this study, we examined the in vitro effects of static magnetic fields (SMF) on murine peritoneal macrophages. The cells were exposed in vitro to SMF of $150{\sim}250$ or $350{\sim}450$ G in 5% $CO_2$-incubator. The phagocytic activity of murine peritoneal macrophages was inhibited under exposure to SMF. In order to provide a more complete picture of molecular mechanism for the biological effect of SMF, we compared the levels of total proteins from macrophages with or without exposure to SMF using quantitative proteomic analysis. Proteins which were differentially expressed in macrophages exposed to SMF compared with non-exposed macrophages, were identified. Among them, the levels of trypsinogen 16, lactose-binding lectin Mac-2, galactoside-binding lectin, actin-like (Put. ${\beta}-actin$, vimentin) and electron transferring flavoprotein beta polypeptide were enhanced under exposure to SMF. These results suggest that SMF can affect the phagocytic activity of macrophages via diverse mechanisms.

THE EFFECT OF STATIC MAGNETIC FIELDS ON MOLECULAR AND CELLULAR ACTIVITIES (정자기장이 효소와 세포 활성에 미치는 영향)

  • Park, Jae-Gu;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.27 no.6 s.65
    • /
    • pp.929-941
    • /
    • 1997
  • Optimal force for orthodontic treatment is the force that produces a rapid rate of tooth movement without discomfort to the Patient or ensuing tissue damage. Recently considerable interest has been generated in the application of magnets as a way to obtain an optimal force. The purpose of the present study was to investigate the effect of static magnetic fields of Sm-Co magnets on molecular and cellular activities. The distance of erythrocyte sedimentation was measured directly, and the activities and the syntheses of $Fe^{2+}$-related enzymes (catalase and NO synthase) and non $Fe^{2+}$-related enzyme (lactic dehydrogenase) were assayed by the spectrophotometer. The growth and the proliferation of osteoblast-like cells $MC_3T_3-E_1$ were determined by the crystal violet staining and the ${^3}H$-thymidine incorporation. The erythrocytes were exposed to the pole face flux density of 1,400 G (gauss), and the enzymes and osteoblast-like cells $MC_{3}T_3-E_1$ were exposed to the flux density of 7,000 G. The results obtained were as follows: 1. The distance of sedimentation of erythrocyte was not affected by the static magnetic fields. 2. The activities of catalase and lactic dehydrogenase were not affected by the static magnetic fields. 3. The intracellular syntheses of NO synthase and lactic dehydrogenase were not affected by the static magnetic fields. 4. The growth and the proliferation of cultured osteoblast-like cells $MC_{3}T_3-E_1$ were not affected by the static magnetic fields. These results suggested that the molecular and cellular activities were not significantly influenced by the static magnetic fields.

  • PDF

A Study on the Oxygen Saturation Level Changes in the Blood Exposed to the Static Magnetic Field (자속에 노출된 인체의 혈중 산소 포화농도의 변화에 관한 연구)

  • Jung, Yong-Chul;Lee, Dong-Hoon
    • Journal of the Korean Society of Safety
    • /
    • v.22 no.6
    • /
    • pp.87-90
    • /
    • 2007
  • The effects of static magnetic field on the human biological system are becoming increasingly more important with the adaption of static magnet in the medical community. It is the goal of this paper to review the effects of static magnetic fields on oxygen saturation level in blood. The results of this paper show that the oxygen saturation level increased in the blood in index finger when the static magnetic dipole was fitted on index finger.

Biological Effects of Static Magnetic Fields and ELF-Electromagnetic Field on Microcirculation in Animals

  • Ohkubo, Chiyoji;Okano, Hidyuki;Xu, Shenzhi;Gmitrov, Jraj
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 1999.07a
    • /
    • pp.117-129
    • /
    • 1999
  • Acute effects of locally applied of static magnetic field (SMF) and extremely low frequency electromagnetic field(ELF-EMF) to the cutaneous tissue within a rabbit ear chamber (REC)were evaluated under conscious conditions. Rabbits with the REC were subjected to intravital microscopical investigation by use of microphotoelectric plethysmography(MPPG). There was no dose-response relationship between the extent of vasomotion changes and frequencies(0,20,50, 100Hz)or power levels (1, 5, 10, 25, 50, 100, 200 mT). Under low vascular tone the both fields induce vasodilatation. The effects of SMF (1 mT) on the cutaneous microcirculatory system induced the vasodilatation with enhanced vasomotion under nor-adrenaline-induced high vascular tone as well as the vasoconstriction with reduced vasomotion under acetylcholine-induced low vascular tone. This suggests that the SMF can modulate vascular tone due to the modification of vasomotion biphasically in the cutaneous tissue.

  • PDF

Guidelines of IRPA/ICNIRP for Non-ionizing Radiation (비이온화방사선에 대한 IRPA/ICNIRP의 제반지침)

  • Lee, Soo-Yong
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.3
    • /
    • pp.143-154
    • /
    • 1995
  • In recent years, the development of new technologies using static magnetic fields has increased the possibility of human exposure to these fields and raised some concern as to their possible health effects. In several countries, governmental or other competent authorities have issued exposure limits that are mainly intended for specific uses, i.e., magnetic resonance imaging (MRI) and particle accelerators for high-energy Physics. Since applications of magnetic fields in industry and medicine are likely to grow in the future, thus increasing the possibility of occupational and general public exposure, and since the number of people with ferromagnetic implants and implanted electronic devices that can be affected by the fields is growing, there is a need for international guidelines. In the present papers, guidelines on limits of exposure to static magnetic fields are selected and discussed in order to review the guidelines of the International Non-ionizing Radiation Committee of the International Radiation Protection Association (IRPA/INIRC) for non-ionizing radiation(NIR)

  • PDF

gnetic Fields With Hysteresis Characteristics (히스테리시스 특성을 고려한 자계의 유한 요소 해석)

  • Jung, Hoon;Hong, Sun-Ki;Won, Jong-Soo
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.38 no.12
    • /
    • pp.1033-1047
    • /
    • 1989
  • A finite element method for the analysis of magnetic fields with hysteresis characteristics is proposed. The method employs Preisach model to describe hysteresis of magnetic material, so that even multi-branch or minor-loop characteristics can be taken into account. The problem can be considered as the analysis of a nonlinear equation where magnetization depends not only on the present value of the magnetic field but also on the past values, and the problem can be solved by the iteration method. Measurements were carried out on soft ferrite EI core for the comparison with computer solution, and good agreements were obtained. is investigated. A theoretical approach to gait study is proposed in which the static stability margins for periodic gaits are expressed in terms of the kinematic gait formula. The effects fo the stride length on static stability are analyzed and the relations between static stability and initial body configurations are examined. It is shown that the moving velocity can be increased to some extent without affecting stability margins for a given initial body configuration. Computer simulations are performed to verify the analysis.

  • PDF

Proteomic analysis of murine peritoneal macrophages after in vitro exposure to static magnetic field

  • Soon, Eun-Jae;Woong, Ko-Dae;Geun, Kwak-Young
    • Proceedings of the Korean Society of Applied Pharmacology
    • /
    • 2003.11a
    • /
    • pp.113-113
    • /
    • 2003
  • A number of studies have demonstrated recently nonthermal interactions of extremely low frequency electromagnetic fields with cellular systems, such as the cells of the immune system. Particular concern came from epidemiological findings, which correlated environmental exposure of human body to weak electromagnetic fields with an elevated risk for developing certain type of leukemias and cancers. Several home/environmental sources generating extremely low frequency electromagnetic fields, such as 50 - 60 Hz high-voltage transmission lines, video display terminals, electric blankets, clinical nuclear magnetic resonance imaging procedures, etc., may interact with the human body. In this study we examined the effects of static magnetic fields (SMF) on the phagocytosis of the murine peritoneal macrophages (C57BL/6). The cells were exposed in vitro for 24 h at 37$^{\circ}C$ to 400 G SMF. The phagocytic activity of peritoneal macrophages was determined with a luminometer. Exposure to the SMF decreased phagocytic activity of murine peritoneal macrophages. In order to provide a more exact mechanism of the phenomenon, we analyzed peritoneal macrophages for alteration in their proteomes. The expression levels of these 5 proteins were increased in the SMF. In total 5 proteins which were differentially expressed in the SMF compared with control group were identified. The expression levels of these 5 proteins were increased in the SMF.

  • PDF

Low-ε Static Probe Development for 15N-1H Solid-state NMR Study of Membrane Proteins for an 800 MHz NB Magnet

  • Park, Tae-Joon;Choi, Sung-Sub;Jung, Ji-Ho;Park, Yu-Geun;Kim, Yongae
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.3
    • /
    • pp.823-826
    • /
    • 2013
  • A low-${\varepsilon}$ solid-state NMR(Nuclear Magnetic Resonance) probe was developed for the spectroscopic analysis of two-dimensional $^{15}N-^1H$ heteronuclear dipolar coupling in dilute membrane proteins oriented in hydrated and dielectrically lossy lipid environments. The system employed a 800 MHz narrow-bore magnet. A solenoid coil strip shield was used to reduce deleterious RF sample heating by minimizing the conservative electric fields generated by the double-tuned resonator at high magnetic fields. The probe's design, construction, and performance in solid-state NMR experiments at high magnetic fields are described here. Such high-resolution solid-state NMR spectroscopic analysis of static oriented samples in hydrated phospholipid bilayers or bicelles could aid the structural analysis of dilute biological membrane proteins.

Extraction of Geomagnetic Field from KOMSAT-1 Three-Axis Magnetometer Data

  • Hwang, Jong-Sun;Lee, Sun-Ho;Min, Kyung-Duck;Kim, Jeong-Woo
    • Proceedings of the KSRS Conference
    • /
    • 2002.10a
    • /
    • pp.242-242
    • /
    • 2002
  • The Earth's magnetic field acquired from KOMPSAT-1's TAM (Three-Axis Magnetometer) between June 19th and 21st 2000 was analyzed. The TAM, one of the KOMPSAT-1's Attitude and Orbit Control Subsystems, plays an important role in determining and controlling the satellite's attitude. This also can provide new insight on the Earth's magnetic field. By transforming the satellite coordinate from ECI to ECEF, spherical coordinate of total magnetic field was achieved. These data were grouped into dusk (ascending) and dawn (descending) data sets, based on their local magnetic times. This partitioning is essential for performing 1-D WCA (Wavenumber Correlation Analysis). Also, this enhances the perception of external fields in the Kompsat-1's TAM magnetic maps that were compiled according to different local. The dusk and dawn data are processed independently and then merged to produce a total field magnetic anomaly map. To extract static and dynamic components, the 1-D and 2-D WCAs were applied to the sub-parallel neighboring tracks and dawn-dusk data sets. The static components were compared with the IGRF, the global spherical harmonic magnetic field model. The static and dynamic components were analyzed in terms of corefield, external, and crustal signals based on their origins.

  • PDF

Surface and size dependent effects on static, buckling, and vibration of micro composite beam under thermo-magnetic fields based on strain gradient theory

  • Mohammadimehr, Mehdi;Mehrabi, Mojtaba;Hadizadeh, Hasan;Hadizadeh, Hossein
    • Steel and Composite Structures
    • /
    • v.26 no.4
    • /
    • pp.513-531
    • /
    • 2018
  • In this article, static, buckling and free vibration analyses of a sinusoidal micro composite beam reinforced by single-walled carbon nanotubes (SWCNTs) with considering temperature-dependent material properties embedded in an elastic medium in the presence of magnetic field under transverse uniform load are presented. This system is used at micro or sub micro scales to enhance the stiffness of micro composite structures such as bar, beam, plate and shell. In the present work, the size dependent effects based on surface stress effect and modified strain gradient theory (MSGT) are considered. The generalized rule of mixture is employed to predict temperature-dependent mechanical and thermal properties of micro composite beam. Then, the governing equations of motions are derived using Hamilton's principle and energy method. Numerical results are presented to investigate the influences of material length scale parameters, elastic foundation, composite fiber angle, magnetic intensity, temperature changes and carbon nanotubes volume fraction on the bending, buckling and free vibration behaviors of micro composite beam. There is a good agreement between the obtained results by this research and the literature results. The obtained results of this study demonstrate that the magnetic intensity, temperature changes, and two parameters elastic foundations have important effects on micro composite stiffness, while the magnetic field has greater effects on the bending, buckling and free vibration responses of micro composite beams. Moreover, it is shown that the effects of surface layers are important, and observed that the changes of carbon nanotubes volume fraction, beam length-to-thickness ratio and material length scale parameter have noticeable effects on the maximum deflection, critical buckling load and natural frequencies of micro composite beams.