• 제목/요약/키워드: state constrained system

검색결과 84건 처리시간 0.022초

Integrating Fuzzy based Fault diagnosis with Constrained Model Predictive Control for Industrial Applications

  • Mani, Geetha;Sivaraman, Natarajan
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권2호
    • /
    • pp.886-889
    • /
    • 2017
  • An active Fault Tolerant Model Predictive Control (FTMPC) using Fuzzy scheduler is developed. Fault tolerant Control (FTC) system stages are broadly classified into two namely Fault Detection and Isolation (FDI) and fault accommodation. Basically, the faults are identified by means of state estimation techniques. Then using the decision based approach it is isolated. This is usually performed using soft computing techniques. Fuzzy Decision Making (FDM) system classifies the faults. After identification and classification of the faults, the model is selected by using the information obtained from FDI. Then this model is fed into FTC in the form of MPC scheme by Takagi-Sugeno Fuzzy scheduler. The Fault tolerance is performed by switching the appropriate model for each identified faults. Thus by incorporating the fuzzy scheduled based FTC it becomes more efficient. The system will be thereafter able to detect the faults, isolate it and also able to accommodate the faults in the sensors and actuators of the Continuous Stirred Tank Reactor (CSTR) process while the conventional MPC does not have the ability to perform it.

Stable Input-Constrained Neural-Net Controller for Uncertain Nonlinear Systems

  • Jang-Hyun Park;Gwi-Tae Park
    • KIEE International Transaction on Systems and Control
    • /
    • 제2D권2호
    • /
    • pp.108-114
    • /
    • 2002
  • This paper describes the design of a robust adaptive controller for a nonlinear dynamical system with unknown nonlinearities. These unknown nonlinearities are approximated by multilayered neural networks (MNNs) whose parameters are adjusted on-line, according to some adaptive laws far controlling the output of the nonlinear system, to track a given trajectory. The main contribution of this paper is a method for considering input constraint with a rigorous stability proof. The Lyapunov synthesis approach is used to develop a state-feedback adaptive control algorithm based on the adaptive MNN model. An overall control system guarantees that the tracking error converges at about zero and that all signals involved are uniformly bounded even in the presence of input saturation. Theoretical results are illustrated through a simulation example.

  • PDF

슬라이딩 섹터를 갖은 가변구조제어를 이용한 비선형제어 (Nonlinear Control using the Variable Structure Control with Sliding Sector)

  • 한종길;손영수;배상현
    • 한국정보통신학회논문지
    • /
    • 제8권4호
    • /
    • pp.807-814
    • /
    • 2004
  • 채터링 현상은 VSS의 주요한 약점이며 이 문제를 극복하기위하여 많은 연구들이 발표되었다. 슬라이딩 섹터 이론이 최근에 발표되었으며, 섹터 안에서 제어입력 없이 상태의 놈이 감소하고 상태가 섹터 안에 있는 동안에 상태의 놈은 영으로 수렴한다. 슬라이딩 섹터 이론은 기본적인 연구단계에 있으며 선형시스템에 대하여 연구되어있다. 본 논문에서는 슬라이딩 섹터를 이용하여 불안정한 비선형시스템의 안정화하는 새로운 방식을 제안하며 슬라이딩 섹터에 리아프노프 함수를 이용하여 안정도를 분석한다. 역진자 시스템에 컴퓨터 시뮬레이션을 통하여 제안한 슬라이딩 섹터 제어가 채터링을 줄일 수 있는 것을 확인한다.

Reliability Evaluation of a Microgrid Considering Its Operating Condition

  • Xu, Xufeng;Mitra, Joydeep;Wang, Tingting;Mu, Longhua
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권1호
    • /
    • pp.47-54
    • /
    • 2016
  • Microgrids offer several reliability benefits, such as the improvement of load-point reliability and the opportunity for reliability-differentiated services. The primary goal of this work is to investigate the impacts of operating condition on the reliability index for microgrid system. It relies on a component failure rate model which quantifies the relationship between component failure rate and state variables. Some parameters involved are characterized by subjective uncertainty. Thus, fuzzy numbers are introduced to represent such parameters, and an optimization model based on Fuzzy Chance Constrained Programming (FCCP) is established for reliability index calculation. In addition, we present a hybrid algorithm which combines scenario enumeration and fuzzy simulation as a solution tool. The simulations in a microgrid test system show that reliability indices without considering operating condition can often prove to be optimistic. We also investigate two groups of situations, which include the different penetration levels of microsource and different confidence levels. The results support the necessity of considering operating condition for achieving accurate reliability evaluation.

Performance analysis of SWIPT-assisted adaptive NOMA/OMA system with hardware impairments and imperfect CSI

  • Jing Guo;Jin Lu;Xianghui Wang;Lili Zhou
    • ETRI Journal
    • /
    • 제45권2호
    • /
    • pp.254-266
    • /
    • 2023
  • This paper investigates the effect of hardware impairments (HIs) and imperfect channel state information (ICSI) on a SWIPT-assisted adaptive nonorthogonal multiple access (NOMA)/orthogonal multiple access (OMA) system over independent and nonidentical Rayleigh fading channels. In the NOMA mode, the energy-constrained near users act as a relay to improve the performance for the far users. The OMA transmission mode is adopted to avoid a complete outage when NOMA is infeasible. The best user selection scheme is considered to maximize the energy harvested and avoid error propagation. To characterize the performance of the proposed systems, closed-form and asymptotic expressions of the outage probability for both near and far users are studied. Moreover, exact and approximate expressions of the ergodic rate for near and far users are investigated. Simulation results are provided to verify our theoretical analysis and confirm the superiority of the proposed NOMA/OMA scheme in comparison with the conventional NOMA and OMA protocol with/without HIs and ICSI.

헬리콥터 회전날개깃의 안정성 해석과 제어 (Aeromechanical stability analysis and control of helicopter rotor blades)

  • 김종선
    • 한국항공운항학회지
    • /
    • 제9권1호
    • /
    • pp.59-69
    • /
    • 2001
  • 복합재로 된 회전날개깃을 상자보로 모델링하고 수동/능동 감쇠를 주기 위해 ACL(Active Constrained Damping Layer)을 상하양면에 부착하고 복합변위이론에 기초한 유한요소방법을 이용하여 구조해석을 수행하였다. 이 이론은 ACL내의 복합재와 점탄성층 그리고 압전층의 전단변형효과를 정확하게 모델링하는데 효과적이다. Hankel 의 특이값을 이용해 축차모델을 유도하였으며 축차모델과 측정된 출력에 기초한 LQG 제어기를 설계하였다. 그러나 LQG 제어기는 공칭 운전속도에서는 좋은 성능을 보여주었으나 운전속도가 변하는 상황에 대해서는 강인안정성을 보여주지 못했다. 이 LQG제어기의 강인안정성을 개선하기 위하여 루프전달회복을 통한 강인한 제어기를 설계하였다. 수치 예를 통해 제시된 제어기가 회전날개깃의 공기역학적인 안정성을 개선하는데 효과적이며 동체모드와 연계된 리드-래그 모드감쇠를 증가시켜 회전날개깃의 진동을 효과적으로 억제하는 것을 보였다.

  • PDF

최적화 기법을 이용한 대형 증기터빈 유로설계 (Flow Path Design of Large Steam Turbines Using An Automatic Optimization Strategy)

  • 임홍식;김영상;조상현;권기범
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.771-776
    • /
    • 2001
  • By matching a well established fast throughflow code, with standard loss correlations, and an efficient optimization algorithm, a new design system has been developed, which optimizes inlet and exit flow-field parameters for each blade row of a multistage axial flow turbine. The compressible steady state inviscid throughflow code based on streamline curvature method is suitable for fast and accurate flow calculation and performance prediction of a multistage axial flow turbine. A general purpose hybrid constrained optimization package, iSIGHT has been used, which includes the following modules: genetic algorithm, simulated annealing, modified method of feasible directions. The design system has been demonstrated using an example of a 5-stage low pressure steam turbine for 800MW thermal power plant previously designed by HANJUNG. The comparison of computed performance of initial and optimized design shows significant improvement in the turbine efficiency.

  • PDF

동일한 전달 행렬을 가지는 안정화 가능한 이종 시스템들의 출력 일치 (Output Consensus of Non-identical and Stabilizable Linear Systems Having the Same Transfer Matrix)

  • 김지수;김홍근;심형보;백주훈
    • 제어로봇시스템학회논문지
    • /
    • 제17권9호
    • /
    • pp.857-862
    • /
    • 2011
  • This paper studies the output consensus problem for a class of heterogeneous linear multi-agent systems under a fixed directed communication network. The dynamics, as well as its dimension, of each agent can widely differ from the others, but all the agents are assumed to have the same transfer matrix. In addition, only the system outputs are constrained to be delivered through the network. Under these conditions, we show that the output consensus is reached by a group of identical controllers, which is designed to achieve the state consensus for the homogeneous multi-agent system obtained from the minimal realization of the transfer matrix. Finally, an example is given to demonstrate the proposed result.

SSSC 투입에 따른 연계선로조류의 윤용한계 증대 (A Study on Effects of SSSC Controllers on Interface Flow Limit)

  • 송화창;이병준;권세혁;김슬기
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제50권2호
    • /
    • pp.83-89
    • /
    • 2001
  • This paper introduces a power flow model of SSSC for voltage stability analysis of power system installed with Static Synchronous Compensators. The SSSC model is obtained from the injection model of voltage source inverter by adding the condition that SSSC injection voltage is in quadrature with current of SSSC-installed branch. This model is incorporated into modified CPF algorithm to study effects of SSSC on the security-constrained interface flow limit. Determination of interface flow limit is simply briefed. In case study a 771-bus real system is used to show that interface flow limit can be improved by appropriate control of SSSC in terms of voltage stability.

  • PDF

윈도우환경을 기반으로 한 최적전력조류 프로그램 팩키지 개발 (Windows Based Programming for Optimal Power Flow Analysis)

  • 김규호;이상봉;이재규;유석구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.239-242
    • /
    • 2001
  • This paper presents a windows program package for solving security constrained OPF in interconnected power systems, which is based on the combined application of evolutionary programming(EP) and sequential quadratic programming(SQP). The objective functions are the minimization of generation fuel costs and system power losses. The control variables are the active power of the generating units, the voltage magnitude of the generator, transformer tap settings and SVC setting. The state variables are the bus voltage magnitude, the reactive power of the generating unit, line flows and the tie line flow. In OPF considering security, the outages are selected by contingency ranking method. The resulting optimal operating point has to be feasible after outages such as any single line outage(respect of voltage magnitude, reactive power generation and power flow limits). The OPF package proposed is applied to 10 machines 39 buses model system.

  • PDF