• Title/Summary/Keyword: standing point

Search Result 168, Processing Time 0.023 seconds

Intra- and Inter-rater Reliabilities of Infrasternal Angle Measurement

  • Kim, Moon-Hwan;Weon, Jong-Hyuck
    • The Journal of Korean Physical Therapy
    • /
    • v.27 no.3
    • /
    • pp.154-158
    • /
    • 2015
  • Purpose: The purpose of this study was to propose a new reference point for measurement of the infrasternal angle and to investigate the intra- and inter-rater reliabilities of infrasternal angle measurement using photographs. Methods: Twenty-four healthy male college students participated as subjects in this study. Photographs were taken of subjects in two postures, one standing with the shoulders relaxed and one standing with the shoulders at $150^{\circ}$ abduction. All photographs were analyzed using Image J software. Raters used the photographs to measure the infrasternal angle between the xiphoid process, the medial margin of rib and navel on the right and left sides. The reliability of the infrasternal angle measurement was assessed by means of intraclass correlation coefficients [ICC (3,1)]. The level of statistical significance was set at p<0.05. Results: The intra- and inter-rater reliabilities of the infrasternal angle measurement for the right side at rest were excellent (ICC=0.866 and 0.813, respectively), as were those for the left side at rest (ICC=0.919 and 0.846, respectively). At $150^{\circ}$ shoulder abduction, the intra- and inter-rater reliabilities for measurement of the infrasternal angle on the right side were excellent (ICC=0.972 and 0.778, respectively), as were those for the left side (ICC=0.914 and 0.826, respectively). Conclusion: These findings suggest that this technique can be successfully used to measure the infrasternal angle, thus suggesting a new reference point for determining the length of the internal oblique and external oblique muscles in clinical situations.

Countermovement Jump Strategy Changes with Arm Swing to Modulate Vertical Force Advantage

  • Kim, Seyoung
    • Korean Journal of Applied Biomechanics
    • /
    • v.27 no.2
    • /
    • pp.141-147
    • /
    • 2017
  • Objective: We obtained force-displacement curves for countermovement jumps of multiple heights and examined the effect of an arm swing on changes in vertical jumping strategy. Countermovement jumps with hands on hips (Condition 1) and with an arm swing (Condition 2) were evaluated to investigate the mechanical effect of the arm movement on standing vertical jumps. We hypothesized that the ground reaction force (GRF) and/or center of mass (CoM) motion resulting from the countermovement action would significantly change depending on the use of an arm swing. Method: Eight healthy young subjects jumped straight up to five different levels ranging from approximately 10% (~25 cm) to 35% (~55 cm) of their body heights. Each subject performed five sets of jumps to five randomly ordered vertical elevations in each condition. For comparison of the two jumping strategies, the characteristics of the boundary point on the force-displacement curve, corresponding to the vertical GRF and the CoM displacement at the end of the countermovement action, were investigated to understand the role of arm movement. Results: Based on the comparison between the two conditions (with and without an arm swing), the subjects were grouped into type A and type B depending on the change observed in the boundary point across the five different jump heights. For both types (type A and type B) of vertical jumps, the initial vertical force at the start of push-off significantly changed when the subjects employed arm movement. Conclusion: The findings may imply that the jumping strategy does change with the inclusion of an arm swing, predominantly to modulate the vertical force advantage (i.e., the difference between the vertical force at the start of push-off and the body weight).

An Experimental Study on the Characteristics for Open-Tube and Closed-Tube Thermoacoustic Effects (2)- The 2nd, 3rd Harmonic (개방관과 밀폐관의 열음향 효과에 관한 하모닉 특성 연구(2) - 2차, 3차 하모닉)

  • 송규조;박종호;이성노
    • Progress in Superconductivity and Cryogenics
    • /
    • v.4 no.1
    • /
    • pp.135-139
    • /
    • 2002
  • In this study, the experimental open-tube and close-tube thermoacoustic apparatuses were built. In order to determine the optimum length of resonant tube and the optimum length of stack, the resonant characteristics of thermoacoustic apparatuses were investigated, The length of resonant tube varies from 400mm to 850mm. The experimental frequency varies from 100Hz to 1000Hz. In case of the second and third harmonics, the maximum temperature difference of open-tube thermoacoustic apparatus is 53$^{\circ}C$ (resonator length: 400mm) and the maximum temperature difference of closed-tube thermoacoustic apparatus is 51$^{\circ}C$ (resonator length: 500mm). In the open-tube thermoacoustic apparatus, the peak efficiency point is about 2%, 55%, 69% in the resonant tube and in the closed-tube thermoacoustic apparatus, the peak efficiency point is about 2%, 41%, 50% in the resonant tube.

A Study on the Development of R-R Interval Analyzer using Microcomputer (1) (Microcomputer를 이용한 R-R Interval Analyzer 개발에 관한 연구 (1))

  • Lee, Joon-Ha;Choi, Soo-Bong
    • Journal of Yeungnam Medical Science
    • /
    • v.2 no.1
    • /
    • pp.77-80
    • /
    • 1985
  • The R-R interval analyzer was developed to measure the autonomic nervous system function using microcomputer. The system based on 8 bit microcomputer including bandpass filter, R-wave detector and clock generator in order to obtain the mean value, standard deviation, total time, CV value, maximum value and minimum value in the specific view point of R-R interval variation. The pattern of R-R interval change after resting, voluntary standing and deep breathing can be analysed in normal subjects and diabetics with autonomic nervous dysfunction. The amplitude of the R-R interval variation showed sensitive pattern for normal subjects at resting, standing and deep breathing. On the contrary, the periodicities of amplitude for abnormal subjects with autonomic nervous dysfunction showed dull pattern. It was suggested that R-R interval analyzer is a good detection method for dysfunction of autonomic nervous system.

  • PDF

Comfort Evaluation by Wearing a Gait-Assistive Rehabilitation Robot (보행보조 재활 로봇 착용에 따른 쾌적성 평가)

  • Eom, Ran-i;Lee, Yejin
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.44 no.6
    • /
    • pp.1107-1119
    • /
    • 2020
  • This study analyzed a subject's body reaction and subjective sensation when wearing a gait-assistive rehabilitation robot. The research method measured skin and clothing surface temperatures for 'seating-standing' and 'walking in place' exercises after wearing a gait-assistive rehabilitation robot. In addition, subjective sensation and satisfaction were evaluated on a 7-point Likert scale. The study results showed that the average skin temperature during exercise while wearing the gait-assistive rehabilitation robot was within a comfortable range. However, during the 'seating-standing' exercise, the skin temperature was slightly lowered. Additionally, the clothing surface temperature tended to be lower than the pre-exercise temperature after all exercises. The subjective sensation evaluation results showed that the wear comfort of the waist part was low during mobility/activity. In addition, an overall improvement in the wear comfort of the robot is necessary. The short-time movement of wearing and walking in the gait-assistive rehabilitation robot did not interfere with the thermal comfort of the body. However, the robot needs to be ergonomically improved in consideration of the long wearing time along with improved material that to satisfy overall wearing comfort.

Effects of Shoe Heel-Heights on the Foot Comfort (구두의 굽높이가 발의 쾌적감에 미치는 영향)

  • Kim Hyo Eun
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.10 no.2
    • /
    • pp.21-28
    • /
    • 1986
  • This paper is concerned with the mutual relationship among interpressure, last. foot within a new shoe and foot within a fifty-hour-used shoe at the standing posture at three different heel-heights 1. The interrelationship between the heel-heights and interpressure is very significant at the level of $0.1\%$. The heel-heights cause high interpressure at different parts of foot; heel point and big toe point in a 3 cm-heel shoe, big toe point and heel outside joint point in a 5 cm-heel shoe, and little toe point, heel-outside joint point, and arch point in a 7 cm-heel shoe. 2. Foot girth and foot width measurements either within a new shoe or within a fifty-hour-used shoe significant at the level of $5\%,\;1\%,\;0.1\%$ and show discrepancies at three different heel heights; the part between instep and ball joint in a 3 cm-heel shoe, toe part in a 5 cm-heel shoe, heel-inside joint. heel-outside joint and toe part in a 7 cm-heel shoe are highly influenced by heel heights. The higher the shoe-hee15 are, the more heavily the fore part of foot is pressured in lateral direction because shoe is made to have high instep from a fashion viewpoint. Higher shoe heels prevent weight pressure from being concentrated on heel. If shoe heels are toe high, people in such shoes feel easily tired. It is very worthy of note in selecting shoes to consider not only the shoe fashion but also fore shoe type, heel height, and shoe material with proper elasticity.

  • PDF

A Study on the Setting of Breast Measurement Points on 3D Scan Data

  • Sohn, Boo-Hyun;Han, Hyun-Suk
    • Journal of the Korea Society of Computer and Information
    • /
    • v.25 no.5
    • /
    • pp.81-90
    • /
    • 2020
  • In this paper, we propose setting measurement point in the 3D scan data based on the manual measurement data. The optimal 3D body scan postures and measurement points for automatic measurement of breast were set up. The outer breast point may be different depending on the body shape or standing posture as it is on the line connected from the bisecting point of the lateral waist thickness to front armpit point. Therefore, it is necessary to consider the breast-related outer point proposed in this study. And many researches need to reduce the differences between MAM and 3D dimension items associated with the upper breast point. When measuring depth, the difference by pressing in MAM should be taken into account. And the differences in flexion depending on breast type can make a difference in the 3D measurement. So the measurement method in 3D scan should be further studied depending on the types of breast and verified by multiple subjects.

Design and Implementation of Dual Band Modified Biconical Antenna for Wireless LAN

  • Oh Jong Dae;Son Ji Myoung;Yang Woon Geun
    • Proceedings of the IEEK Conference
    • /
    • summer
    • /
    • pp.181-184
    • /
    • 2004
  • In this paper, we propose the dual band(2.4GHz and 5GHz) antenna for access point of WLAN(Wireless Local Area Network) which has similar radiation patterns for each band. Simulation results by using HFSS(High Frequency Structure Simulator) for the proposed antenna are presented. The electrical characteristics of the proposed antenna are measured with HP 8510C network analyzer and included. And radiation patterns are measured with rectangular anechoic far field antenna chamber. Measured results show that $S_{11}$ is less than - 14dB and VSWR(Voltage Standing Wave Ratio) is less than 1.5 for all frequency bands of interest. The measured maximum gain for elevation pattern at 2.40GHz is about 2.46dBi at $theta=-78^{\circ}$ and maximum gain for 5.825GHz is about 2.70dBi at $theta=-80^{\circ}.$ And the implemented antenna has good radiation pattern characteristic, therefore, we expect that the implemented dual band antenna is applicable for access point of WLAN.

  • PDF

Characteristics of Forces upon Two-dimensional Circular Cylinder by External Singularities (외부 특이점이 2차원 원주에 작용하는 힘의 특성)

  • Lee, Seung-Joon
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.47 no.6
    • /
    • pp.782-786
    • /
    • 2010
  • Thrust deduction related to the prediction of power performance of a ship is rather resistance increase, and as a preliminary study for it forces upon a circular cylinder in a uniform flow of ideal fluid due to singularities located behind it are investigated. The circle theorem is used to get the complex velocity potential for the flow field under consideration, and the Blasius theorem is applied to obtain forces upon the circular cylinder. As singularities sinks, point vortices and dipoles and their combinations are treated. $\varepsilon$, standing for the strength of a singularity, and $\delta$, representing the distance between the cylinder and the singularity, are important small parameters for the resistance and lateral forces. For sinks or point vortices it is shown that the dimensionless forces upon the cylinder is O($\epsilon$) if $\epsilon$= O($\delta$) is assumed, and the same holds for dipoles if $\epsilon$= O(${\delta}^3$) is supposed. Forces upon the cylinder by a symmetric pair of sinks are greater than a single sink located at the central plane since there is an additional term due to cross effects, and the same is also valid for the case of dipole. Combination of dipole and a point vortex is also considered and a few new aspects are clarified.

A Study on the Variables of Success in the National Dental Hygienist Licence Examination at D College (D대학교 치과위생사 국가시험 합격의 변인에 관한 연구)

  • Lee, Sun-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.8
    • /
    • pp.3486-3491
    • /
    • 2012
  • The purpose of this study was to examine the variables of success in the national dental hygienist licence examination at D college. The subjects in this study were 120 dental hygiene juniors at D college located in Gangwon Province. The collected data were analyzed by the statistical package SPSS WIN 13.0 and a R2.13.2 program, and $x^2$(Chi-square) test, regression analysis, multiple linear regression analysis and logistic regression analysis were utilized. The findings of the study were as follows: 1. There was a tendency that the pass rate was higher among the students who were more satisfied with their major, whose academic standing was higher and who scored higher in trial examinations. 2. There was a positive correlation between academic standing and trial exam scores. 3. When their academic standing and satisfaction level with major were the same, an increase of one point in trial exams led to a 1.141-fold rise in the probability of passing the national exam. In this study, trial exam scores were identified as the variable to exert the largest influence on success in the national dental hygienist qualification exam. Therefore more intensive guidance should be provided for students who make a preparation for the national exam yet score low in trial exams.