• Title/Summary/Keyword: standby current failure

Search Result 6, Processing Time 0.022 seconds

A Technique for Analyzing LSI Failures Using Wafer-level Emission Analysis System

  • Higuchi, Yasuhisa;Kawaguchi, Yasumasa;Sakazume, Tatsumi
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.1 no.1
    • /
    • pp.15-19
    • /
    • 2001
  • Current leakage is the major failure mode of semiconductor device characteristic failures. Conventionally, failures such as short circuit breaks and gate breakdowns have been analyzed and the detected causes have been reflected in the fabrication process. By using a wafer-level emission-leakage failure analysis method (in-line QC), we analyzed leakage mode failure, which is the major failure detected during the probe inspection process for LSIs, typically DRAMs and CMOS logic LSIs. We have thus developed a new technique that copes with the critical structural failures and random failures that directly affect probe yields.

  • PDF

A Fault Tolerance Mechanism with Dynamic Detection Period in Multiple Gigabit Server NICs (다중 Gigabit Server NICs에서 동적 검출 주기를 적용한 결함 허용 메커니즘)

  • 이진영;이시진
    • Journal of Internet Computing and Services
    • /
    • v.3 no.5
    • /
    • pp.31-39
    • /
    • 2002
  • A rapid growth of internet and sudden increase of multimedia data demands for high-speed transfer media and if optimizec usage from the interface system. To achieve this level of network bandwidth, multiple NICs for support of high-speed network bandwidth have been developed and studied. Furthermore, the use of multiple NICs can provide high-speed LAN environment without large network environment modification, supports backward compatibility of current system and reduce overhead. However. if system failure is caused by SPOF(Single Point of Failure) fault of large-capacity multiple NICs, incredible loss will be met because it services large capacity of multimedia data, Therefore, to prevent loss coming from faults, we describe 'Fault tolerance of multiple NICs', which use the fault prevention mechanism. Considering inefficiency of availability and serviceability that is occurred with existing TMR, Primary-Standby approach and Watchdog time mechanism, we propose and design the efficient fault tolerance mechanism, which minimize down time as changing of detection period dynamically. Consequently, the fault tolerance mechanism proposed for reducing overhead time when the fault is occurred, should minimize system downtime overall.

  • PDF

Research About Design and Implementation of On-Line Game Server for High Availability guarantee using Heartbeat (HeartBeat을 이용한 고가용성(High Availability) 보장 온라인 게임 서버 구축 제안)

  • Kim, Tae-Yul;Kyung, Byung-Pyo;Ryu, Seuc-Ho;Lee, Wan-Bok
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2006.05a
    • /
    • pp.193-198
    • /
    • 2006
  • Providing stable services has been a crucial factor to determine success or failure in current situations, in which online game industry has become one of the important industries. The study proposed a method of establishing a stable game servers using 'Hearbeat', one of the existing (load) balance server techniques for the enhancement of availability of online game servers. In the proposed method, one could provide users with stable game services, by inspecting master server frequently using stand-by servers corresponding to each game server.

  • PDF

Grid Peak Power Limiting / Compensation Power Circuit for Power Unit under Dynamic Load Profile Conditions (Dynamic Load Profile 조건의 전원 장치에 있어서 계통 Peak Power 제한/보상 전력 회로)

  • Jeong, Hee-Seong;Park, Do-Il;Lee, Yong-Hwi;Lee, Chang-Hyeon;Rho, Chung-Wook
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.5
    • /
    • pp.376-383
    • /
    • 2022
  • The improved performance of computer parts, such as graphic card, CPU, and main board, has led to the need for power supplies with a high power output. The dynamic load profile rapidly changes the usage of power consumption depending on load operations, such as PC power and air conditioner. Under dynamic load profile conditions, power consumption can be classified into maximum, normal, and standby power. Several problems arise in the case of maximum power. Peak power is generated at the system power source in the maximum-power situation. Frequent generation of peak power can cause high-frequency problems and reduce the life of high-pressure parts (especially high-pressure capacitors). For example, when a plurality of PCs are used, system overload occurs due to peak power generation and causes problems, such as power failure and increase in electricity bills due to exceeded contract power. To solve this problem, a system peak power limit/compensation power circuit is proposed for a power supply under dynamic load profile conditions. The proposed circuit detects the system current to determine the power situation of the load. When the system current is higher than the set level, the circuit recognizes that the system current generates peak power and compensates for the load power through a converter using a super capacitor as the power source. Thus, the peak power of loads with a dynamic load profile is limited and compensated for, and problems, such as high-frequency issues, are solved. In addition, the life of high-pressure parts is increased.

Development and Safety Evaluation of Earth Leakage Alarm Breaker Equipped with Fire Current (IGR) Alarming Function (화재전류(IGR) 경보 기능이 내장된 누전경보차단기의 개발 및 안전성 평가에 관한 연구)

  • Ko, Wan-Su;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.34 no.3
    • /
    • pp.43-48
    • /
    • 2020
  • The purpose of this study is to develop an earth leakage alarm circuit breaker, equipped with a leakage alarming function (JER-E2S, ETECKOREA Co., Korea), and to analyze its characteristics. The developed mechanism is exclusively used for single-phase and 220 V circuits, with a rated current of 32 A, 20 A, 20 A (for restrooms), 16 A, etc. It satisfies all characteristics of existing earth leakage circuit breakers (ELB). If a fire current, which is a resistive leakage current (Igr), flows through an electric line, the device detects the leakage current in real time and warns against the leakage through a blinking LED lamp. Since the developed device displays a tolerance to a capacitative leakage current (Igc) that inevitably occurs in LED lamps, communication devices, etc., it ensures a stable power supply. In addition, the earth leakage alarm circuit breaker protects against power failure due to a momentary ground fault. Therefore, it can supply power without the risk of the circuit breaker malfunctioning due to a momentary ground fault caused by water droplets, leaves, etc. Moreover, with a standby power of less than 0.1 W, the developed earth leakage alarm circuit breaker exhibits a power saving performance that is 3~8 times greater than that of other ELBs. Installation of approximately 10 earth leakage alarm circuit breakers in one apartment household, with an area of 120 ㎡, can save 2~5 kWh per month. Therefore, the developed earth leakage alarm breaker not only satisfies the characteristics of existing earth leakage breakers, but also exhibits outstanding power supply quality since it has the functions of electric fire prevention and malfunction prevention. Therefore, this device can innovatively contribute to electric fire prevention.

EXPERIMENTAL INVESTIGATIONS RELEVANT FOR HYDROGEN AND FISSION PRODUCT ISSUES RAISED BY THE FUKUSHIMA ACCIDENT

  • GUPTA, SANJEEV
    • Nuclear Engineering and Technology
    • /
    • v.47 no.1
    • /
    • pp.11-25
    • /
    • 2015
  • The accident at Japan's Fukushima Daiichi nuclear power plant in March 2011, caused by an earthquake and a subsequent tsunami, resulted in a failure of the power systems that are needed to cool the reactors at the plant. The accident progression in the absence of heat removal systems caused Units 1-3 to undergo fuel melting. Containment pressurization and hydrogen explosions ultimately resulted in the escape of radioactivity from reactor containments into the atmosphere and ocean. Problems in containment venting operation, leakage from primary containment boundary to the reactor building, improper functioning of standby gas treatment system (SGTS), unmitigated hydrogen accumulation in the reactor building were identified as some of the reasons those added-up in the severity of the accident. The Fukushima accident not only initiated worldwide demand for installation of adequate control and mitigation measures to minimize the potential source term to the environment but also advocated assessment of the existing mitigation systems performance behavior under a wide range of postulated accident scenarios. The uncertainty in estimating the released fraction of the radionuclides due to the Fukushima accident also underlined the need for comprehensive understanding of fission product behavior as a function of the thermal hydraulic conditions and the type of gaseous, aqueous, and solid materials available for interaction, e.g., gas components, decontamination paint, aerosols, and water pools. In the light of the Fukushima accident, additional experimental needs identified for hydrogen and fission product issues need to be investigated in an integrated and optimized way. Additionally, as more and more passive safety systems, such as passive autocatalytic recombiners and filtered containment venting systems are being retrofitted in current reactors and also planned for future reactors, identified hydrogen and fission product issues will need to be coupled with the operation of passive safety systems in phenomena oriented and coupled effects experiments. In the present paper, potential hydrogen and fission product issues raised by the Fukushima accident are discussed. The discussion focuses on hydrogen and fission product behavior inside nuclear power plant containments under severe accident conditions. The relevant experimental investigations conducted in the technical scale containment THAI (thermal hydraulics, hydrogen, aerosols, and iodine) test facility (9.2 m high, 3.2 m in diameter, and $60m^3$ volume) are discussed in the light of the Fukushima accident.