• Title/Summary/Keyword: standardized test

Search Result 1,001, Processing Time 0.032 seconds

Vibration-Analysis of rubber-tired AGT light rail vehicle (고무차륜 AGT 경량전철 차량의 진동해석)

  • Kim Y.S.;Jeon R.G.;Lim T.K.;Lee J.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.39-42
    • /
    • 2005
  • Dynamic model of the Korea standardized rubber-tired AGT light rail vehicle, and boundary conditions between vehicle and infrastructures (running track, guidance rail) were defined to analyze vehicular vibration behaviors occurred at the worst condition. Using the commercialized software RecurDyn, vibration accelerations of car body and bogies were analyzed. and, based on the ISO standard 2631-1, the vibration characteristic test is performed in the test track. As the results, the Korea standardized rubber-tired AGT light rail vehicle satisfied the ISO standard criteria and design requirement.

  • PDF

Random response analysis of Missile Guidance Structure by using Finite Element Method (유한요소 해석을 이용한 Missile Guidance Structure의 Random response analysis)

  • Kim, Jaeki;Nam, Kwangsik;choi, Jinkyu;Choi, Homin;Zhao, Shang;Yeom, Sang Hun;Lee, Seoksoon
    • Journal of Aerospace System Engineering
    • /
    • v.9 no.2
    • /
    • pp.51-56
    • /
    • 2015
  • In the vibration test, Most of the test specifications is standardized methods of sinusoidal excitation. However, in accordance with the ability of the test equipment progress and developments of electronic technology, methods of random vibration test is standardized in the MIL standard. Therefore, in this study, we tried to analyze Missile Guidance Structure using a finite element analysis with ABAQUS 6.13 that is commercial program. First, Random response analysis is analyzed. Following analyzing the results, we wanted to find the model that is lightweight and resonance does not occur.

Unit Testing for the AUTOSAR Software Component (AUTOSAR 소프트웨어 컴포넌트의 유닛 테스트 방법)

  • Kum, Dae-Hyun;Lee, Seong-Hun;Park, Gwang-Min;Son, Byeong-Jeom
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.16 no.11
    • /
    • pp.1061-1065
    • /
    • 2010
  • AUTOSAR, a standard software platform for automotive, has been developed to manage software complexity and improve software reuseability. However Automated and standardized testing is needed to improve reliability and reduce time and effort on testing. Fundamental functionality of AUTOSAR RTE and basic software modules is guaranteed by using an AUTOSAR tool, but application software components have to be tested thoroughly. In this paper, we suggest a test system for the AUTOSAR software component using TTCN-3, a standardized testing language. Test execution system and test cases for the software component are generated automatically from AUTOSAR XML containing software design information. With the proposed testing techniques we can reduce time and effort to build the testing system.

NEW PHARMACOLOGICAL, CLINICAL, MICROBIOLOGICAL AND ANALYTICAL TESTS MADE WITH VARIOUS GINSENG PREFARATIONS OF THE WORLD MARKET

  • Rueckert Karl Heinz
    • Proceedings of the Ginseng society Conference
    • /
    • 1978.09a
    • /
    • pp.85-92
    • /
    • 1978
  • The aim of the double blind test was to assess the prophylactic and therapeutic efficacy of the preparation GINSANA, containing the standardized ginseng extract PHARMATON G115,. The determination was carried out with special emphasis on the following features : general physical condition, physical performance, mental performance, enjoyment of life/mood, concentration and memory, as well as sleeping habits. Sixty test persons took part in the study, men and women between the ages of 22 and 80. The 90-day test was carried out in the form of a double blind experiment. Experimental measurements were made and the persons were also questioned. The reaction time, the optical merging threshold, the coordination of both hands and the recovery quotients, as well as the recovery rates were analyzed. The results for the serum group were clearly better than those for the placebo group, particularly for the characteristics: general physical condition, physical performance and sleeping habits. The results of the test methods used, especially with regard to the reaction time, the coordination of both hands, the recovery quotient and the recovery period, permit the following conclusion to be drawn: when administered for several weeks, GINSANA has a positive action, in the sense of an activation of the entire personality by the ginseng glycosides contained in the standardized Extracts G115.

  • PDF

"Cohesiveness of Hyaluronic Acid Fillers": Evaluation Using Multiple Cohesion Tests

  • Kyun Tae Kim;Won Lee;Eun-Jung Yang
    • Archives of Plastic Surgery
    • /
    • v.51 no.1
    • /
    • pp.14-19
    • /
    • 2024
  • Background Hyaluronic acid fillers can be manufactured using various processes. They have multiple properties, including their concentration, degree of modification, and rheological data. Cohesion is one such property to evaluate gel integrity; however, there is no standardized method for calculating this parameter. This study aimed to evaluate different tests for calculating hyaluronic acid cohesion and discuss the importance of hyaluronic acid cohesion as a consideration when selecting fillers. Methods The cohesion levels of five different hyaluronic acid fillers with different rheological properties were evaluated and compared using the drop weight, compression, tack, and dispersion time tests. Results The cohesion tests yielded different results in the samples. Samples 2 and 4 showed approximately two times the number of droplets when compared with Sample 5 in drop weight test. Samples 1, 2, 3, and 4 were superior to Sample 5 in tack test. Samples 1, 2, and 3 showed cohesive appearances at 95 seconds in most cases in dispersion test. Rheological test results did not reflect the measures of cohesion. Conclusion Although there are no definite standardized tests to evaluate the cohesion of hyaluronic acid fillers, our proposed tests showed similar results for different hyaluronic acid filler products. Further studies are needed to evaluate the cohesion of hyaluronic acid fillers and determine the clinical use of this distinguishing characteristic for clinicians selecting the product of choice. Level of evidence statement: These data are Level IV evidence.

The effect of Simulation-based learning scenario using standardized repiratory patients on learning satisfaction, clinical skill competency and self-efficacy in Health-related department students (호흡기계 표준화환자를 활용한 시뮬레이션 기반 시나리오 학습이 보건계열 대학생의 학습만족도, 임상수행능력과 자기효능감에 미치는 효과)

  • Cho, Hye-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.3
    • /
    • pp.2100-2108
    • /
    • 2015
  • This study was conducted to examine the effects of a simulation-based learning scenario using standardized respiratory patients regarding emergency care on learning satisfaction, and self efficacy, clinical skill competency of health related department students. A quasi-experimental non-equivalent control group pre-post test design was used. A total of 50 students, 25 students for the experimental group and 25 students for the control group, The experimental group received the 2 educations sessions and 1 evaluation session with 180 minutes for each session. It was implemented in November, 2013. Data were analysed using frequency, ratio and t-test by the SPSS/Win 18.0. The experimental group who had the simulation-based learning scenario using standardized respiratory patients showed significantly higher learning satisfaction and self efficacy, clinical skill competency compared with the control group who had a traditional simulation education. Through this study, simulation-based learning scenario using standardized patients was verified to be an effective teaching method to be grow up on professional competency of health related department students. Also the simulation-based learning scenario using standardized patients should be developed in the various fields.

Association between Sleep and Loneliness in the Elderly Living Alone (독거노인의 외로움과 수면의 관계)

  • Choi, Yu Jung;Lee, Kyung Kyu;Lee, Seok Bum;Kim, Kyung Min;Kim, Dohyun;Lee, Jung Jae
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.28 no.2
    • /
    • pp.168-176
    • /
    • 2020
  • Objectives : Loneliness and poor sleep quality are common phenomena in old age and are associated with negative physical and mental health. However, little is known regarding the relation between loneliness and sleep quality. The aim of this study was to examine the association of loneliness and sleep quality among the elderly living alone. Methods : This is a cross-sectional study that enrolled 1,090 subjects who are the community-residing elderly living alone. Sociodemographic status, medical condition, cognition, mood disorder, sleep quality and levels of loneliness were collected using a self-administered questionnaire and a specific semi-structured interview conducted by trained nurses. Descriptive statistics were used to analyze data regarding sociodemographic variable and loneliness. Univariate and Multivariate regression analyses were applied to examine the association between loneliness and sleep quality after adjustment for multiple confounding variables. Results : The Pittsburgh Sleep Quality Index (PSQI) mean score of "lonely group" (9.2±4.2) was significantly higher than that of "not lonely group" (7.3±3.7) (student-t test, p<0.001). Loneliness was significantly associated with PSQI (standardized β=0.065, p=0.025), sleep disturbance (standardized β=0.086, p=0.005), use of sleep medication (standardized β=0.065, p=0.034) after adjustment for possible confounding variables including sex and mood disorder. Conclusions : Loneliness was associated with sleep disturbance and this finding implied negative impact of loneliness on sleep quality of older adults. Public health promotion efforts to reduce loneliness may improve sleep quality and mental health in the elderly living alone.

A Study on the Standardized Finite Element Models for Carbody Structures of Railway Vehicle Made of Sandwich Composites (샌드위치 복합재 적용 철도차량 차체 구조물의 표준유한요소모델 제시 연구)

  • Jang, Hyung-Jin;Shin, Kwang-Bok;Ko, Hee-Young;Ko, Tae-Hwan
    • Journal of the Korean Society for Railway
    • /
    • v.13 no.4
    • /
    • pp.382-388
    • /
    • 2010
  • This paper describes the standardized finite element model for carbody structures of railway vehicle made of sandwich composites. Recently, sandwich composites were widely used to railway vehicle due to the improvement of energy efficiency, high specific stiffness and strength, weight reduction and space saving in korea. Therefore, structural integrity should be verified using finite element analysis prior to the manufacture of composite railway vehicle. The standardized finite element model for composite carbody structures was introduced through comparing the results of real structural test under vertical, compressive, twisting load and natural frequency test of various railway vehicles in this study. The results show that the quadratic shell element is suitable to model the reinforced metal frame used to improve the flexural stiffness of sandwich panel compared to beam element, and layered shell and solid element are recommended to model the skin and honeycomb core of sandwich panel compared to sandwich shell element. Also, the proposed standard finite element model has the merit of being applied to crashworthiness problem without modifications of finite element model.

A Study on the Development and Verification of a Logical Thinking Ability Measuring Tool in Computer Programming Learning (컴퓨터 프로그래밍 학습에서 논리적 사고력 측정도구의 개발과 타당화 연구)

  • Lee, Joataek;Yi, Sangbong
    • The Journal of Korean Association of Computer Education
    • /
    • v.7 no.4
    • /
    • pp.15-25
    • /
    • 2004
  • Previous researches on the effect of programming learning upon logical thinking ability have used a standardized test to measure logical thinking ability in the general and comprehensive aspect after programming learning. Considering that the areas of intelligence are separated from one another and work independently, the existing standardized tool to measure general and comprehensive logical thinking ability has a limitation in measuring a logical thinking ability required at specific areas. Thus this study extracted logical thinking and its sub-factors related to computer programming and suitable for the level of cognitive development through analyzing standardized test sheets at home and abroad, and developed logical thinking test I and II of the same form according to a development procedure model. The result of verifying the developed logical thinking tests proved that the two tests are logical thinking tests of the same form. The developed tests can be utilized in identifying the effect of programming learning upon logical thinking and its sub-factors.

  • PDF

APICAL FITNESS OF NON-STANDARDIZED GUTTA-PERCHA CONES IN SIMULATED ROOT CANALS PREPARED WITH ROTARY ROOT CANAL INSTRUMENTS (전동화일로 형성된 근관에서 비표준화 Gutta-percha Cone의 적합성)

  • Kwon, O-Sang;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.3
    • /
    • pp.390-398
    • /
    • 2000
  • The purpose of this study was to evaluate the apical fitness of non-standardized gutta-percha cones in root canals prepared with rotary Ni-Ti root canal instruments of various tapers and apical tip sizes. Simulated sixty curved root canals of plastic blocks were prepared with crown-down technique using rotary root canal instruments of Maillefer ProFile$^{(R)}$ .04 and .06 taper (Maillefer Instrument SA, Switzerland). Specimens were divided into six groups and prepared as follows: Group 1, prepared up to size 25 of .04 taper ; Group 2, prepared up to size 30 of .04 taper ; Group 3, prepared up to size 35 of .04 taper ; Group 4, prepared up to size 25 of .06 taper ; Group 5, prepared up to size 30 of .06 taper ; Group 6 ; prepared up to size 35 of .06 taper. After cutting off the coronal portion of plastic, blocks perpendicular to the long axis of the canal with the use of a diamond saw, apical 5mm of canal space was analyzed. Prepared apical canal spaces were duplicated using rubber base impression material to evaluate two dimensional total area of apical canal space. Various sized gutta-percha cones were applied in the 5mm-apical canal space, which were size 25, size 30 and size 35 standardized gutta-percha cone, Diadent Dia-Pro ISO-.04$^{TM}$ and .06$^{TM}$(Diadent, Korea), and medium-fine (MF), fine (F), fine-medium (FM) and medium (M) sized non-standardized gutta-percha cones (Diadent, Korea). Coronal excess gutta-percha were cut off with a sharp blade. Photographs of impressed apical canal spaces and gutta-percha cones were taken with a CCD camera under a stereomicroscope and stored in a computer. Areas of the total canal space and gutta-percha cones were calculated using a digitalized image analysing program, CompuScope (Sungjin Multimedia Co., Korea). Ratio of apical fitness was obtained by calculating the area of gutta-percha cone to the total area of the canal space. The data were analysed statistically using One-way Analysis of Variance and Duncan's Multiple Range Test. The results were as follows: 1. In canals prepared up to size 25 ProFile$^{(R)}$ of .04 taper, non-standardized MF and F cones occupied significantly more canal space than Dia-Pro ISO-.04$^{TM}$ or size 25 standardized ones (p<0.05). 2. In canals prepared up to size 30 ProFile$^{(R)}$ of .04 taper, non-standardized F cones occupied significantly more canal space than Dia-Pro ISO-.04$^{TM}$ or size 30 standardized ones (p<0.05), and non-standardized MF cones occupied more canal space than size 30 standardized ones (p<0.05). 3. In canals prepared up to size 35 ProFile$^{(R)}$ of .04 taper, there was no significant difference in canal space occupation among non-standardized MF and F, size 35 standardized, and Dia-Pro ISO-.04$^{TM}$ cones (p>0.05). 4. In canals prepared up to size 25 ProFile$^{(R)}$ of .06 taper, non-standardized MF and F cones occupied significantly more canal space than Dia-Pro ISO-.06$^{TM}$, or size 25 standardized ones (p<0.05), and Dia-Pro ISO-.06$^{TM}$, cones occupied significantly more space than size 25 standardized ones (p<0.05). 5. In canals prepared up to size 30 ProFile$^{(R)}$ of .06 taper, non-standardized FM cones occupied significantly more canal space than Dia-Pro ISO-.06$^{TM}$ or size 30 standardized ones (p<0.05), and non-standardized F cones occupied significantly more canal space than size 30 standardized ones (p<0.05). 6. In canals prepared up to size 35 ProFile$^{(R)}$ of .06 taper, non-standardized M and FM, Dia-Pro ISO-.06$^{TM}$ occupied significantly more canal space than size 35 standardized ones (p<0.05). In summary, in both canals prepared with .04 or .06 taper ProFile$^{(R)}$, non-standardized cones showed better fitness than Dia-Pro ISO$^{TM}$ or standardized ones, which was more characteristic in smaller canals.

  • PDF