• Title/Summary/Keyword: standard testing method

Search Result 578, Processing Time 0.024 seconds

A Comparison of Static and Dynamic Deformation Modulus by Dynamic Plate Test (동평판 재하시험을 이용한 정적 및 동적 변형계수 비교)

  • 박용부;정형식
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.5
    • /
    • pp.335-342
    • /
    • 2003
  • The method of measuring ground deformation modulus, in situ-testing has the disadvantage where the exam number is limited because it needs counter weight and a lot of measurement times. Recently, it has supplemented this problem and the equipments by which measurement can be made quickly are developed and applied in field., That is Falling Weight Deflectometer(FWD), Light Drop Weight Tester(LDWT), Geogauge. Light Drop Weight Teste.(LDWT) is introduced firstly in the name of ‘a lightweight fall circuit tester for a railroad public corporation’ by KTX. Since KTX introduced LDWT, a number of research organizations have used LDWT to find out domestic standard for quality management of base ground. In this study we used ZFG 02 which was manufactured by Stendal in Germany and measured the dynamic deformation modulus in soil box and in-situ. And we analyzed the correlation of the dynamic deformation modulus with static deformation modulus based on plate test in the same ground.

Estimation of User Activity States for Context-Aware Computing in Mobile Devices (모바일 디바이스에서 상황인식 컴퓨팅을 위한 사용자 활동 상태 추정)

  • Baek Jonghun;Yun Byoung-Ju
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.43 no.1 s.307
    • /
    • pp.67-74
    • /
    • 2006
  • Contort-aware computing technology is one of the key technology of ubiquitous computing in the mobile device environment. Context recognition computing enables computer applications that automatically respond to user's everyday activity to be realized. In this paper, We use accelerometer could sense activity states of the object and apply to mobile devices. This method for estimating human motion states utilizes various statistics of accelerometer data, such as mean, standard variation, and skewness, as features for classification, and is expected to be more effective than other existing methods that rely on only a few simple statistics. Classification algorithm uses simple decision tree instead of existing neural network by considering mobile devices with limited resources. A series of experiments for testing the effectiveness of the our context detection system for mobile applications and ubiquitous computing has been performed, and its result is presented.

Chromogenic In Situ Hybridisation Test for Breast Cancer Patients with Equivocal IHC Results - a Study from Iran

  • Mehrazma, Mitra;Kalantari, Elham;Rezvani, Hamid;Bahar, Babak;Basi, Ali;Razavi, Seyed Mohsen;Rakhshani, Nasser
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.17
    • /
    • pp.7695-7700
    • /
    • 2015
  • Background: HER2/neu overexpression on cell membranes of breast cancer cells is due to HER2/neu gene amplification and it is important to identify potential candidates for anti HER2 therapy with trastuzumab. IHC, FISH and CISH are standard FDA approved assays currently used to determine HER2 status in routine practice. The aim of this study was to determine HER2 gene amplification, using the CISH method in breast carcinoma samples which had IHC +2 reactions. Materials and Methods: This study was conducted from 2008-2010 using 334 consecutive breast carcinoma samples referred from local laboratories to Mehr Hospital. CISH assays were performed for all cases, and IHC tests were also done for determining efficacy and accuracy of local labs. HER2 status in local IHC tests was compared with central IHC and CISH results. Results: Of 334 breast cancer patients, 16 were negative for HER2 IHC (0, +1), 201 cases were equivocal (+2), and 31 positive (+3). Of 334 referral cases, 88 were CISH positive (26.3%) and 246 were CISH negative (73.7%). Of 201 IHC +2 cases, HER2 gene amplification was observed in 42 cases (kappa: 0.42). A 29.9% concordance was found between local IHC and central IHC. Sensitivity and specificity of local IHC were 90% and 53.8%, respectively. Conclusions: Low accuracy of IHC results in local labs was associated with the following factors: using former FDA-approved criteria for HER2 interpretation, utilizing non-validated kits, and lack of any quality assurance program. Therefore, following the new 2014 ASCO/CAP guideline and comprehensive quality assurance should be implemented to ensure accuracy of HER2 testing.

Design and Implementation of the Performance Driven UI-Mashup Architecture (성능 주도의 UI-Mashup 아키텍처의 설계 및 구현)

  • Cho, Dong-Il
    • Journal of Internet Computing and Services
    • /
    • v.15 no.1
    • /
    • pp.45-53
    • /
    • 2014
  • UI-Mashup is widely used as a service method to add value, which is composed of distributed various contents on the internet and has turned out to be one of the latest trends in web application program development. Previous UI-Mashup-related studies have focused primarily on the dynamic service composition and have not been able to adapt to a rapidly changing Web Standard, thusthe end users conclude that UI-Mashups are slow, incompatible and poor security services. In this study, We propose an architecture for the performance improvements of UI-Mashup.In order to provide fast services and security enhancements, the proposed architecture collects UI fragments on the server in parallel, and sends layouts and contents of Mashups UI to the client through a special delivery channel supporting fast reaction and response time. In this study, the implementation and performance tests were proceeded to verify the proposed architecture experimentally. As a result of the performance testing, the proposed architecture has two to three times faster response time and more than four times throughput compared to the previous UI-Mashup technology.

A Novel Test Structure for Process Control Monitor for Un-Cooled Bolometer Area Array Detector Technology

  • Saxena, R.S.;Bhan, R.K.;Jalwania, C.R.;Lomash, S.K.
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.6 no.4
    • /
    • pp.299-312
    • /
    • 2006
  • This paper presents the results of a novel test structure for process control monitor for uncooled IR detector technology of microbolometer arrays. The proposed test structure is based on resistive network configuration. The theoretical model for resistance of this network has been developed using 'Compensation' and 'Superposition' network theorems. The theoretical results of proposed resistive network have been verified by wired hardware testing as well as using an actual 16x16 networked bolometer array. The proposed structure uses simple two-level metal process and is easy to integrate with standard CMOS process line. The proposed structure can imitate the performance of actual fabricated version of area array closely and it uses only 32 pins instead of 512 using conventional method for a $16{\times}16$ array. Further, it has been demonstrated that the defective or faulty elements can be identified vividly using extraction matrix, whose values are quite similar(within the error of 0.1%), which verifies the algorithm in small variation case(${\sim}1%$ variation). For example, an element, intentionally damaged electrically, has been shown to have the difference magnitude much higher than rest of the elements(1.45 a.u. as compared to ${\sim}$ 0.25 a.u. of others), confirming that it is defective. Further, for the devices having non-uniformity ${\leq}$ 10%, both the actual non-uniformity and faults are predicted well. Finally, using our analysis, we have been able to grade(pass or fail) 60 actual devices based on quantitative estimation of non-uniformity ranging from < 5% to > 20%. Additionally, we have been able to identify the number of bad elements ranging from 0 to > 15 in above devices.

Collagenolytic Activity Of Gingival Crevicular Fluid In Progressive Periodontitis (진행성 치주염에서의 치은열구액내 교원질분해효소 활성)

  • Chung, Hyun-Ju
    • Journal of Periodontal and Implant Science
    • /
    • v.26 no.1
    • /
    • pp.161-175
    • /
    • 1996
  • There were many reports that elevations in the levels of active and latent collagenase in gingival crevicular fluid(GCF) have been correlated positively with periodontal disease activity. To provide a simple diagnostic approach for testing GCF collagenolytic activity, the detection limit of enzyme activity was compared using radiofibril assay(Sodek et.al.1981) and spectrophotometric collagenolytic assay(Nethery et al. 1986). The detection limits of both assay for standard bacterial enzyme were similar and the radiofibril assay showed a little (1/2) lower detection limit for tad pole collagenase. To evaluate the relationship between periodontal tissue destruction and the collagenolytic activity, GCF was collected, and latent and active enzyme activities were measured by a spectrophotometric collagenolytic assay. Twelve subjects showing progressive lesions were selected according to the presence of immediate tissue destruction, frequent abscess formation, and increasing need for tooth extraction, and the absence of underlying systemic disease and previous antibiotic medication history within 6 months. Comparisons were made between sites with either: 1) inflammation with a previous history of progressive loss of periodontal tissue and bone support(2l progressive sites): 2) previous history of bone loss and periodontal destruction but now clinically stable(12 comparably stable sites); or 3) no loss of periodontal tissue and bone support(11 control sites including 5 gingivitis sites and 6 healthy sites). Active collagenase activity was the highest in the progressive sites and decreased in the order of the gingivitis sites, the stable sites, and the healthy sites. The total enzyme activity was $2{\sim}3$ fold higher in the progressive sites and the gingivitis sites, compared to the stable and the healthy sites. The ratio of active to total collagenolytic activity was twice in the progressive sites. Analysis of active collagenase level(5mU) and the ratio of active to total collagenolytic activity(0.8) as a diagnositic test indicates that these measurements have the sensitivity of 0.81 and 0.86, the specificity of 0.70 and 0.65, and the overall agreement of 0.75 and 0.73, respectively. Thus, this method has significant merits as a diagnostic tool to determine wherher the site is in a state of remission or progression.

  • PDF

Detection of Imprinted Quantitative Trait Loci (QTL) for Growth Traits in Pigs

  • Lee, H.K.;Lee, S.S.;Kim, T.H.;Jeon, G.J.;Jung, H.W.;Shin, Y.S.;Han, J.Y.;Choi, B.H.;Cheong, I.C.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.16 no.8
    • /
    • pp.1087-1092
    • /
    • 2003
  • As an experimental reference population, crosses between Korean native pig and Landraces were established and information on growth traits was recorded. Animals were genotyped for 24 microsatellite markers covering chromosomes 2, 6, and 7 for partial-genome scan to identify chromosomal regions that have effects on growth traits. quantitative trait loci (QTL) effects were estimated using interval mapping by the regression method under the line cross models with a test for imprinting effects. For test of presence of QTL, chromosome-wide and single position significance thresholds were estimated by permutation test and normal significance threshold for the imprinting test were derived. For tests against the Mendelian model, additive and dominance coefficients were permuted within individuals. Thresholds (5% chromosome-wide) against the no-QTL model for the analyzed traits ranged from 4.57 to 4.99 for the Mendelian model and from 4.14 to 4.67 for the imprinting model, respectively. Partial-genome scan revealed significant evidence for 4 QTL affecting growth traits, and 2 out of the 4 QTLs were imprinted. This study demonstrated that testing for imprinting should become a standard procedure to unravel the genetic control of multi-factorial traits. The models and tests developed in this study allowed the detection and evaluation of imprinted QTL.

A STUDY ON THE FRACTURE TOUGHNESS OF DENTAL COMPOSITE RESINS (치과용 복합레진의 파괴인성에 관한 실험적 연구)

  • Park, Jin-Hoon;Min, Byung-Soon;Choi, Ho-Young;Park, Sang-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.15 no.2
    • /
    • pp.17-33
    • /
    • 1990
  • The purpose of this study was to evaluate the fracture toughness of dental composite resins and to investigate the filler factor affecting the fracture behaviour on which the degree of fracture toughness depends. Six kinds of commercially available composite resin;, including two of each macrofilled, microfilled, and hybrid type were used for this study, The plane strain fracture toughness ($K_{10}$) was determined by three-point bending test using the single edge notch specimen according to the ASTM-E399. The specimens were fabricated with visible light curing or self curing of each composite resin previously inserted into a metal mold, and three-point bending test was conducted with cross-head speed of 0.1mm/min following a day's storage of the specimens in $37^{\circ}C$ distilled water. The filler volume fractions were determined by the standard ashing test according to the ISO-4049. Acoustic Emission(AE), a nondestructive testing method detecting the elastic wave released from the localized sources In material under a certain stress, was detected during three-point bending test and its analyzed data was compared with, canning electron fractographs of each specimen. The results were as follows : 1. The filler content of composite resin material was found to be highest in the hybrid type followed by the macrofilled type, and the microfilled type. 2. It was found that the value of plane strain fracture toughness of composite resin material was in the range from 0.69 MPa$\sqrt{m}$ to 1 46 MPa$\sqrt{m}$ and highest In the macrofilled type followed by the hybrid type, and the microfilled type. 3. The consequence of Acoustic Emission analysis revealed that the plane strain fracture toughness increased according as the count of Acoustic Emission events increased. 4. The higher the plane strain fracture toughness became, the higher degree of surface roughness and irregularity the fractographs demonstrated.

  • PDF

Performance Evaluation of Motorcycle's Anti-theft Device using NFC Authentication and Solenoid Valve (NFC 보안인증과 솔레노이드 밸브를 이용한 이륜차 이동제한장치 성능평가)

  • Moon, Boram;Jin, Taeseok
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.26 no.1
    • /
    • pp.82-86
    • /
    • 2016
  • This paper proposes a method for the immobilization of motorbike brakes in conjunction with near-field communication (NFC) technology in order to meet the increasing demand for security and convenience of motorbike drivers. We thought about the concept of wireless key, NFC security devices and automatic solenoid valve for setting the lock and unlock module. This paper propose the design and development of an innovative anti-theft alarm system for motorcycles using NFC smart devices based on RFID system, the basis of IoT and AES(advanced encryption standard) encryption Algorithm. The design concept is based on NFC communication strategy between the vehicle and owner. To do this concept, we designed motorcycle smart key system with general-purpose NFC system and the automatic solenoid valve for setting the lock and unlock module. First, we designed control unit and NFC card reader for motorcycle smart key system. Then we propose an AES encryption algorithm and prove that the motorcycle key system is controllable by showing the result of implementing and testing, after installing.

Visibility Evaluation for Agricultural Tractor Operators According to ISO 5006 and 5721-1 Standards

  • Kabir, Md. Shaha Nur;Song, Mingzhang;Chung, Sun-Ok;Kim, Yong-Joo;Kim, Su-Chul;Ha, Jong-Kyou
    • Journal of Biosystems Engineering
    • /
    • v.40 no.1
    • /
    • pp.19-27
    • /
    • 2015
  • Purpose: A system to measure the visibility of agricultural tractor operators was designed and evaluated according to ISO standards, and a blind area diagram around the tested tractor was created based on the manual method recommended by the National Institute for Occupational Safety and Health (NIOSH). Methods: A visibility measurement system was designed and evaluated based on the ISO 5006 and ISO 5721-1 standards. Two bulbs used to simulate the operator's eyes were mounted on a bar with a supporting frame. A wooden frame was used to determine the seat index point position. The 12-m visibility test circle was divided into six sectors of vision, and the test tractor was placed at the center of the circle. Artificial light was supplied in the darkened environment, and shadow or masking effects were measured manually around the 12-m circle. Results: When the bulbs were placed at the operator's eye level, front visibility was good; no masking was found in the "A" vision sector, but larger masking widths were found in the "B" and "C" vision sectors. Since the masking width exceeded 700 mm, additional tests, such as movement of the light sources to both sides of the operator's eye level, were performed. Less than six masking effects were found in the semi-circle of vision to the front, and more than one masking was found in the "B" and "C" visual fields. The minimum distance between the centers of two masking effects exceeded 2500 mm when measured as a chord on the semi-circle of vision. A blind area diagram was created to define the exact nature of the blind spots and mirror visibility. Conclusions: Visibility evaluation is an effective way to enable proper and safe operation for agricultural tractor operators. Inclusion of this visibility evaluation test in the general testing process might aid tractor manufacturers.