• Title/Summary/Keyword: standard size

Search Result 3,299, Processing Time 0.03 seconds

A Study of Development of land use design system using GA for Agricultural area (유전자 알고리즘을 이용한 경지 구획 결정 지원 시스템 개발에 관한 연구)

  • Jung, Yun-Chul;Yun, Sung-Soo;Lee, Jung-Jae
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2001.10a
    • /
    • pp.228-235
    • /
    • 2001
  • For standard size of farmland in Korea is small, we have to consume huge labor for cultivation and efficiency of machine is low. We practice the project, which make size of farmland enlarge. For many factors have to consider in design process in case of large-scale farmland, there are difficulties for comparing alternatives if we design it manually. So we need to techniques for establishing various alternatives and choosing the optimum design by the computer. In this study, fixing the boundary of project using the RGIS (Rural Geographical Information System) which standard electronic map in Korea. In the boundary, we analysis the many characteristics of farm land, optimize the adjustment process of field unit of farmland. In this process, we develop automatic farmland division techniques. The results of adapting the developed system show the usefulness to enlarge the size of farmland about 200%.

  • PDF

Implementation of Radix-2 structure to reduce chip size (Chip면적 감소를 위한 Radix-2구조 구현)

  • 최영식;한대현
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 1999.05a
    • /
    • pp.407-410
    • /
    • 1999
  • Viterbi decoder is implemented with a Radix-4 architecture at 0.5$\mu\textrm{m}$ process even though the delay time of standard tell is big and it causes a bigger chip size. As process develops, the delay time of standard cells is getting smaller. Therefore, the requirement of speed and chip size is satisfied by using Radix-2 algorithm to implement Viterbi decoder.

  • PDF

Weight Decision Scheme based on Slot-Count in Gen-2 Q-Algorithm

  • Lim, In-Taek
    • Journal of information and communication convergence engineering
    • /
    • v.9 no.2
    • /
    • pp.172-176
    • /
    • 2011
  • In the Gen-2 Q-algorithm, the values of weight C, which is the parameter for incrementing or decrementing the slot-count size, are not optimized in the standard. However, the standard suggests that the reader uses small values of C when the slot-count is large and larger values of C when the slot-count is small. In this case, if the reader selects an inappropriate weight, there are a lot of empty or collided slots. As a result, the performance will be declined because the frame size does not converge to the optimal point quickly during the query round. In this paper, we propose a scheme to select the weight based on the slot-count size of current query round. Through various computer simulations, it is demonstrated that the proposed scheme achieves more stable performances than Gen-2 Q-algorithm.

The Experimental Evaluation and Verification of a 300kW Small Engine Cogeneration System (300kW급 가스엔진 열병합발전시스템 성능평가 및 실증)

  • Choi, Jae-Joon;Park, Hwa-Choon
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.332-337
    • /
    • 2009
  • The importance of the evaluation and verification of small-size cogeneration system has been emphasized because there is no KS-code related to the small-size cogeneration system. The evaluation method of small-size engine cogeneration system, regarding Japanese standard JIS B-8122 and international standard organization, ISO-8528, was applied to the system. The evaluation methods, start-test, rapid-load-up and rapid-load-down, etc. were executed at the system, and reasonable results were acquired. The electrical and thermal efficiencies were executed and analyzed at various load conditions. The NOx emission at various load condition was also measured. Finally, the gas engine cogeneration system was installed to a site for actual usage and it was continually operated during more than 6 months as the site condition.

  • PDF

Determination of Sampling Unit Size for Cultivation Area Survey using Remote Sensing Technology

  • Park, Jin-Woo;Shin, Gi-Eun;Lee, Suk-Hoon;Byun, Jong-Seok
    • The Korean Journal of Applied Statistics
    • /
    • v.25 no.5
    • /
    • pp.733-741
    • /
    • 2012
  • The successful launch of Arirang satellites allow the acquisition of high resolution satellite imagery of Korean territory and enables the transition from the conventional cultivation area survey method to new image based methods adopted in advanced nations. In this study, we suggested reasonable sizes of the primary sampling unit and the secondary sampling unit for the satellite imagery based sampling design in 8 provinces preselected for this research. The PSU size was determined mainly in consideration of intracorrelation that shows the degree of homogeneity within each cluster and the efficiency of the image process. For the SSU size, we considered the relative standard error and the differences between the land cover maps produced by the Ministry of Environment and the satellite imagery processed by the National Statistical Office.

Size Effect of Compressive Strength of Concrete for the Cylindrical Specimens Considering Strength Level (강도수준을 고려한 원주형 공시체에 대한 콘크리트 압축강도의 크기효과)

  • Kim, Hee-Sung;Jin, Chi-Sub;Eo, Seok-Hong
    • Magazine of the Korea Concrete Institute
    • /
    • v.11 no.2
    • /
    • pp.95-103
    • /
    • 1999
  • The reduction phenomena of concrete compressive strength with the size of specimens have been extensively investigated, but till now the adequate analysis technique is not fixed. The existing research results show that the bigger the member size, the smaller the strength. This means the nonlinear fracture mechanics theory is needed in order to analyze the fracture behaviors of concrete and the size effect. There is a few model equations that is to predict the size effect of compressive strength of standard and non-standard cylindrical specimen. However, theses equations did not considered the difference of fracturing mechanism which depends on the strength level. In this paper, model equations to predict compressive strength of concrete considering the size effect and strength level are suggested. The size effect model suggested in this paper shows good prediction compared with the existing test data of various concrete size and strength level.

Particle Size of Aerosol from 0.25% Cadmium Chloride Nebulizing Solution for Inhalation Toxicology Study (흡입독성 연구에 이용될 0.25% 염화카드뮴 네뷸라이징 용액 에어로졸의 입경)

  • Jeung Jae Yeal;Lee Ki Nam
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.17 no.5
    • /
    • pp.1257-1263
    • /
    • 2003
  • The modified engineering methodology and the modified electronic circuit in classical ultrasonic principles were applied to ultrasonic aerosol nebulizer for inhalation toxicology study of cadmium aerosol. 1532.96ppm Cd nebulizing solution was used to generate cadmium aerosol for particle size analysis with the modifying source and inlet temperatures. The results of particle size analysis for cadmium aerosol were as following. The highest particle counting for source temperature 20℃ was 399.75 × 10² in inlet temperature 100℃ and particle diameter 0.75㎛. The highest particle counting for source temperature 50℃ was 399.70 × 10² in inlet temperature 50℃ and particle diameter 0.75㎛. The highest particle counting for source temperature 70℃ was 411.14 × 10² in inlet temperature 100℃ and particle diameter 0.75㎛. The ranges of geometric mean diameter were 0.74-0.79㎛ in source temperature 20℃, 0.65-0.72㎛ in source temperature 50℃, and 0.65-0.80㎛ in source temperature 70℃. The smallest geometric mean diameter was 0.65㎛ in source temperature 50, 70℃ and inlet temperature 20, 50℃, and the largest geometric mean diameter was 0.80㎛ in source temperature 70℃ and inlet temperature 100℃. The ranges of geometric standard deviation were 1.71-1.80 in source temperature 20℃, 1.27-1.61 in source temperature 50℃, and 1.27-2.29 in source temperature 70℃. The lowest geometric standard deviation was 1.27 in source temperature 50, 70℃ and inlet temperature 20, 50℃, and the highest geometric standard deviation was 2.29 in source temperature 70℃ and inlet temperature 100℃. Generated aerosol for cadmium inhalation toxicology study was polydisperse aerosol with the above geometric standard deviation 1.2. The ranges of mass median diameter(MMD) were 1.75-2.25㎛ in source temperature 20℃, 1.27-1.61㎛ in source temperature 50℃, and 1.27-2.29㎛ in source temperature 70℃. The smallest MMD was 1.27㎛ in source temperature 50, 70℃ and inlet temperature 20, 50℃, and the largest MMD was 2.29㎛ in source temperature 70℃ and inlet temperature 100℃. Cadmium chloride concentration in nebulizing solution affected the particle size and distribution of cadium aerosol in air. MMO for inhalation toxicology testing in OECD and EU is less than 3㎛ and EPA guidance is less than 4㎛. In our results, in source temperatures of 20, 50, 70℃, and inlet temperatures of 20, 50, 100, 150, 200, 250℃ were conformed to the those guidance.

A Conceptual Algorithm for Determining the Spacing of Standard Penetration Test Spots. (표준관입시험 간격 결정을 위한 개념적 알고리즘)

  • Habimana, Gilbert;Lee, Donghoon;Han, Kyung-Bo;Kim, Sunkuk
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.11a
    • /
    • pp.185-186
    • /
    • 2015
  • The Standard penetration test determines the type of soil according to soil bearing capacity, and this classifies the subsoil into many layers. Construction project managers are willing to know the depth of the present types of subsoil on site in order to make plans on earthwork stage during excavation. However the standard penetration test may not provide accurate information on subsoil type due to incorrect spacing. To solve this problem, this study propose a conceptual algorithm for determining the spacing of standard penetration test spots to essentially tests relevant locations on which to be applied the standard penetration test. This provides the acquirement of the accurate layered model volume of earthwork revised into geological columnar section. This algorithm will determine the appropriate standard penetration test spots spacing on a given size of site to optimize the accuracy of the earthwork volume, time and cost.

  • PDF

Standard sand for geotechnical engineering and geoenvironmental research in Nigeria: Igbokoda sand

  • Ojuri, Oluwapelumi O.;Fijabia, David O.
    • Advances in environmental research
    • /
    • v.1 no.4
    • /
    • pp.305-321
    • /
    • 2012
  • This study entails establishing reference standard sand in Nigeria for engineering and geoenvironmental research work. Sands from four geographical locations in southwestern Nigeria were examined for baseline geotechnical and mineralogical properties. A total of sixteen sand samples were collected. The samples were air dried and subjected to tests in accordance with standard specifications. The tests carried out were: specific gravity, grain size analysis, moisture content, bulk density, porosity, void ratio, chemical analysis, X-ray diffraction and Differential Thermal Analysis. The properties of the samples were compared with a standard (Ottawa sand in Illinois of the United States) in order to find out which of the four samples selected from southwestern Nigeria could serve as standard baseline sand. The results show that Igbokoda sand has geotechnical and mineralogical characteristics closest to Ottawa sand. It was therefore concluded that Igbokoda sand could be used as a standard baseline sand for research work in southwestern Nigeria and other parts of Nigeria since it needs little processing to bring it to the same level as standard baseline sand, like the Ottawa sand.

Survey on Labeling of Health Functional Foods in Internet Shopping Malls

  • PARK, Sang-Kyu;UHM, Tai-Hwan
    • Journal of Distribution Science
    • /
    • v.17 no.6
    • /
    • pp.57-63
    • /
    • 2019
  • Purpose - This research is to review the state of standard labeling compliance and identify the factors that are conducive to compliance with the Labeling Standards of the Health Functional Foods Act in internet distribution. Research design, data, and methodology - We checked 9 labels including product name, expiration date, manufacturing date, raw material, ingredient, operative dose, nutritional information, daily intake, and functional effect which are based on Labeling Standards of the Act from 100 health functional foods in the internet shopping malls. These 9 structure & function claims were compared using a Chi-square test. Results - There was a statistically significant difference in the use of standard labeling between domestic product and imported products (p<.001). The related strength between these two variables showed a moderate effect size. Also, there was a statistically significant difference between accredited advertising/unaccredited advertising distinction and use of standard labeling (p<.001). The related strength between these two variables showed a moderate effect size. Conclusions - The Labeling Standards of the Act were not followed and found to be related to imports or unauthorized advertising in internet distribution. The information displayed according to the Labeling Standards was only about 2 on the average, so many labels have been posted unreadably without arrangement.