• Title/Summary/Keyword: standard regulations

검색결과 708건 처리시간 0.03초

Fuzzy optimization for the removal of uranium from mine water using batch electrocoagulation: A case study

  • Choi, Angelo Earvin Sy;Futalan, Cybelle Concepcion Morales;Yee, Jurng-Jae
    • Nuclear Engineering and Technology
    • /
    • 제52권7호
    • /
    • pp.1471-1480
    • /
    • 2020
  • This research presents a case study on the remediation of a radioactive waste (uranium: U) utilizing a multi-objective fuzzy optimization in an electrocoagulation process for the iron-stainless steel and aluminum-stainless steel anode/cathode systems. The incorporation of the cumulative uncertainty of result, operational cost and energy consumption are essential key elements in determining the feasibility of the developed model equations in satisfying specific maximum contaminant level (MCL) required by stringent environmental regulations worldwide. Pareto-optimal solutions showed that the iron system (0 ㎍/L U: 492 USD/g-U) outperformed the aluminum system (96 ㎍/L U: 747 USD/g-U) in terms of the retained uranium concentration and energy consumption. Thus, the iron system was further carried out in a multi-objective analysis due to its feasibility in satisfying various uranium standard regulatory limits. Based on the 30 ㎍/L MCL, the decision-making process via fuzzy logic showed an overall satisfaction of 6.1% at a treatment time and current density of 101.6 min and 59.9 mA/㎠, respectively. The fuzzy optimal solution reveals the following: uranium concentration - 5 ㎍/L, cumulative uncertainty - 25 ㎍/L, energy consumption - 461.7 kWh/g-U and operational cost based on electricity cost in the United States - 60.0 USD/g-U, South Korea - 55.4 USD/g-U and Finland - 78.5 USD/g-U.

반잠수식 해양 구조물 상부 모듈의 해상 결합 작업시 동하중 평가 (Evaluation of Mating Dynamic Forces of Semi-submersible Offshore Structure Topside Module)

  • 이진호;정현수;김병우
    • 한국해양공학회지
    • /
    • 제27권1호
    • /
    • pp.9-15
    • /
    • 2013
  • This paper calculates the mating dynamic forces of a semi-submersible offshore structure's topside module, where a hull moored in the sea is combined with a topside module carried by a heavy lift vessel, as a mating installation method. The environmental conditions include various wave directions and wave heights, with constant wind and current speeds. Appropriate ballast and de-ballast plans for the heavy lift vessel and hull of the semi-rig should be performed in order to safely obtain these forces, whereas a fixed platform or the GBS (Gravity based structure) type of offshore structure only needs a ballast plan for the heavy lift vessel. From this paper, the allowable wave height or wave direction for the mating procedure can be investigated based on the standard DAF (Dynamic amplitude factor) of the rules and regulations.

공동주택 발코니 개조 방안 (A Scheme for the Balcony Rebuilding in Apartment Building)

  • 이희복;김은태;박찬식
    • 한국건설관리학회:학술대회논문집
    • /
    • 한국건설관리학회 2004년도 제5회 정기학술발표대회 논문집
    • /
    • pp.468-471
    • /
    • 2004
  • 입주자의 선호도를 무시한 획일적 평면의 공급으로 인해 공동주택 발코니 개조가 심각한 수준에 이르고 있으며, 이로 인해 국가적 손실과 많은 문제점을 유발하고 있다. 지금까지의 많은 선행 연구들은 발코니의 사용실태, 발코니의 개조비율과 개조유형을 조사하여 평면계획상의 개선방안만을 거론하였을 뿐, 개조비용을 산출한 연구는 전무하다. 따라서 본 연구는 첫째, 설문을 통해 발코니의 개조비용을 추정하고, 둘째, 건설회사 분양방식, 거주자의 의식, 관련법령 측면에서 발코니 개조 원인을 분석함으로써, 각 측면에서 발코니 개조를 양성화할 수 있는 방안을 제안하였다.

  • PDF

FVF-Based Low-Dropout Voltage Regulator with Fast Charging/Discharging Paths for Fast Line and Load Regulation

  • Hinojo, Jose Maria;Lujan-Martinez, Clara;Torralba, Antonio;Ramirez-Angulo, Jaime
    • ETRI Journal
    • /
    • 제39권3호
    • /
    • pp.373-382
    • /
    • 2017
  • A new internally compensated low drop-out voltage regulator based on the cascoded flipped voltage follower is presented in this paper. Adaptive biasing current and fast charging/discharging paths have been added to rapidly charge and discharge the parasitic capacitance of the pass transistor gate, thus improving the transient response. The proposed regulator was designed with standard 65-nm CMOS technology. Measurements show load and line regulations of $433.80{\mu}V/mA$ and 5.61 mV/V, respectively. Furthermore, the output voltage spikes are kept under 76 mV for 0.1 mA to 100 mA load variations and 0.9 V to 1.2 V line variations with rise and fall times of $1{\mu}s$. The total current consumption is $17.88{\mu}V/mA$ (for a 0.9 V supply voltage).

항공기 설계변경의 범위 및 영향성에 따른 안전성 인증방법에 관한 고찰 (A Study on Certification Methods due to Scope and Influence of Design Changes for the Aircraft)

  • 이강이;고준수
    • 한국항공우주학회지
    • /
    • 제45권7호
    • /
    • pp.566-573
    • /
    • 2017
  • 항공기의 설계 안전성을 보장하기 위하여 형식증명을 받아야 한다. 형식증명을 받은 항공기의 설계가 중대하게 변경되는 경우, 형식증명을 새로 받거나 개정형식증명 또는 부가형식증명을 신청하여야 한다. 국제민간항공기구, 미국 및 유럽의 인증 규정에서 부가형식증명 대상이 되는 설계변경에 대하여 매우 추상적으로 정의하고 있으므로, 본 논문에서는 설계변경에 관한 세계 각국의 인증절차와 인증사례를 분석하여 부가형식증명 대상이 되는 "광범위하지 않은 중급 설계변경"을 판단하는 기준을 제시하였다.

GIS를 이용한 원등일대의 기반암품질과 골재개발적지 분석 (Survey of Bedrock Quality and Suitable Site for Crushed Stones using GIS in the Wondeung Area)

  • 이진영;양동윤;김주용;홍세선;윤현수
    • 대한공간정보학회지
    • /
    • 제13권4호
    • /
    • pp.47-58
    • /
    • 2005
  • 전라남도 곡성군 남부에 위치한 원등지역에서 기반암의 품질을 검토하고 지리정보시스템(GIS)을 이용하여 개발난이도를 분석하였다. 기반암의 품질을 알기 위하여 야외조사를 수행하였고, 실내에서 물성을 분석하였다. 또한 GIS를 이용한 개발난이도 분석에서 가시권분석과 거리분석을 통해 법적개발제한지역을 분석하였다. 원등일대 연구지역의 기반암 품질과 개발난이도를 분석한 결과, 모두 개발이 가능한 품질을 가지고 있으며, 개발제한사항에 해당되는 정도에 따라 개발난이도가 구분되었다. 또한 개발 난이도가 가장 낮은 조사지역의 약 30 % 지역이 개발 가능한 것으로 나타났다.

  • PDF

Performance evaluation of suspended ceiling systems using shake table test

  • Ozcelik, Ozgur;Misir, Ibrahim S.;Saridogan, Serhan
    • Structural Engineering and Mechanics
    • /
    • 제58권1호
    • /
    • pp.121-142
    • /
    • 2016
  • The national standard being used in Turkey for suspended ceiling systems (SCS) regulates material and dimensional properties but does not contain regulations regarding installation instructions which cause substandard applications of SCSs in practice. The lack of installation instructions would potentially affect the dynamic performance of these systems. Also, the vast majority of these systems are manufactured using substandard low-quality materials, and this will inevitably increase SCS related damages during earthquakes. The experimental work presented here focuses on the issue of dynamic performance of SCSs with different types of carrier systems (lay-on and clip-in systems), different weight conditions, and material-workmanship qualities. Moreover, the effects of auxiliary fastening elements, so called seismic perimeter clips, in improving the dynamic performance of SCSs were experimentally investigated. Results show that clip-in ceiling system performs better than lay-on system regardless of material and workmanship qualities. On the other hand, the quality aspect becomes the most important parameter in affecting the dynamic performance of lay-on type systems as opposed to tile weights and usage of perimeter clips. When high quality system is used, tile weight does not change the performance of lay-on system, however in poor quality system, tile weight becomes an important factor where heavier tiles considerably decrease the performance level. Perimeter clips marginally increase the dynamic performance of lay-on ceiling system, but it has no effect on the clip-in ceiling system under the shaking levels considered.

터널 물분무소화설비의 살수밀도분포에 대한 실험연구 (Experimental study on the spray density distribution of water spray system in road tunnel)

  • 소수현;박경환
    • 한국터널지하공간학회 논문집
    • /
    • 제13권1호
    • /
    • pp.1-8
    • /
    • 2011
  • 장대 도로터널 및 위험도가 높은 도로터널에 설치되고 있는 물분무소화설비는 성능과 관계된 단위면적당 방수밀도에 대한 검증과정이 없이 사용되어 왔다. 본 연구는 도로터널에 물분무소화설비에 노즐을 설치하여 기준압력에서 방수시험을 실시하여 기준을 만족하는지 여부를 확인하였다. 결론적으로 모든 노즐이 기준을 만족하지 못하였다. 이런 결과는 도로터널용 물분무노즐을 검증하는 시험기준이 없고, 실제 시험을 통한 검증 과정이 존재하지 않았기 때문이라고 판단된다. 따라서 물분무노즐의 성능을 시험할 수 있는 기준의 마련과 설치된 시설을 검증하는 제도적인 보완이 필요하다.

고진등수 영역이 보강된 APR1400 설계지반응답스펙트럼의 개발 (Development of the DGRS enriched in the high frequency range for APR1400)

  • 장영선;김태영;주광호;김종학
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2001년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Fall 2001
    • /
    • pp.67-74
    • /
    • 2001
  • This paper presents the Safe Shutdown Earthquake(SSE) input motion for the seismic design of the Advanced Power Reactor 1400(APR1400). The Design Ground Response Spectra(DGRS) far the SSE is based on the design spectrum specified in regulatory Guide(RG) 1.60 of U.S. Nuclear Regulatory Commission(US NRC), anchored to a Peak Ground Acceleration(PGA) of 0.3g and enriched in the high frequency range. This SSE seismic input motion is to be applied to the seismic analysis as the free-field seismic motion at the ground surface of both the rock and generic soil sites fur APRI1400. The enrichment for APR1400 seismic input motion is performed considering the current US NRC regulations, the seismic hazard studies performed by the Lawrence Livermore National Laboratory (LINL) and Electric Power Research Institute(EPRI) for the Central and Eastern United States nuclear power plant sites, and the seismic input motions used in the design certifications of the three existing U.S. advanced standard plants. It is represented by a set of DGRS and the accompanying Target Power Spectral Density(PSD) Function in both the horizontal and vertical directions.

  • PDF

인버터 기반 신재생 에너지 발전 시스템의 계통 지원 운전을 위한 계통 전압 검출 방법 (A Detection Method of Grid Voltage for Grid Support Operation of an Inverter-based Renewable Energy Generation System)

  • 안현철;송승호
    • 신재생에너지
    • /
    • 제9권2호
    • /
    • pp.51-57
    • /
    • 2013
  • The Grid code is being strengthen as increase of renewable energy ratio. Especially, the grid connection regulations are continuously being updated for stable operation of power grids. Static grid support and Dynamic grid support must make an accurate measure at Grid connected point because they needs control algorithm individually. It has to exactly measure voltage including switching ripple at the output of the inverter generating system. In addition, it is necessary to have an accurate voltage measurement when the situation rapidly changing the grid impedance is caused by the input of serial impedance of transformer and line impedance as well as Grid Fault Device. In this paper, We propose a new detection method of grid voltage to calculate accurately the r.m.s voltage of the grid connection point along the standard required by the low voltage regulation. We verified performance through simulation grid fault device.